期刊文献+
共找到355篇文章
< 1 2 18 >
每页显示 20 50 100
Cyclic Voltammetry Determination of Epinephrine with a Nano-gold Modified Glassy Carbon Electrode in the Presence of High Concentration Ascorbic Acid 被引量:1
1
作者 HongZHANG XueQinGUI 《Chinese Chemical Letters》 SCIE CAS CSCD 2002年第2期153-156,共4页
Nano-gold (NG) modified glassy carbon electrodes (GCEs) were used for determination of epinephrine (EP) in the presence of high concentration ascorbic acid (AA) by cyclic voltammetry (CV). This modified electrode can... Nano-gold (NG) modified glassy carbon electrodes (GCEs) were used for determination of epinephrine (EP) in the presence of high concentration ascorbic acid (AA) by cyclic voltammetry (CV). This modified electrode can not only catalytically oxidize EP and AA, but also separate the catalytic peak potentials of EP and AA by about 183.5 mV. In pH = 7.0 ogisogate byffer solution, the linear range of epinephrine was 5 106 ~ 1 ?10-4 mol/L. 展开更多
关键词 NANO-GOLD glassy carbon electrode EPINEPHRINE ascorbic acid cyclic voltammetry.
下载PDF
Voltammetric behavior of sedative drug midazolam at glassy carbon electrode in solubilized systems 被引量:5
2
作者 Rajeev Jain Rajeev Kumar Yadav 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第2期123-129,共7页
Redox behavior of midazolam was studied at a glassy carbon electrode in various buffer systems,supporting electrolytes and pH using differential paise,square-wave and cyclic voltammetry.Based on its reduction behavior... Redox behavior of midazolam was studied at a glassy carbon electrode in various buffer systems,supporting electrolytes and pH using differential paise,square-wave and cyclic voltammetry.Based on its reduction behavior,a direct differential pulse voltammetric method has been developed and validated for the determination of midazolam in parenteral dosage.Three welldefined peaks were observed in 0.1% SLS,Britton-Robinson (BR) buffer of pH 2.5.The effect of surfaetants like sodium lauryl sulfate (SLS),cetyl trimethyl ammonium bromide (CTAB) and Tween 20 was studied.Among these surfactants SLS showed significant enhancement in reduction peak.The cathodic peak currents were directly proportional to the concentration of midazolam with correlation coetfficient of 0.99. 展开更多
关键词 MIDAZOLAM voltammetry SURFACTANT glassy carbon electrode Parenteral dosage form
下载PDF
Electrooxidation of sulfanilamide and its voltammetric determination in pharmaceutical formulation,human urine and serum on glassy carbon electrode 被引量:2
3
作者 Bruno R.L.Ferraz Tiago Guimaraes +1 位作者 Demetrius Profeti Luciene P.R.Profeti 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2018年第1期55-59,共5页
For the first time, sulfanilamide(SFD) was determined in otologic solution, human urine and serum by electroanalytical techniques on glassy carbon electrode(GCE). The cyclic voltammetry(CV) experiments showed an irrev... For the first time, sulfanilamide(SFD) was determined in otologic solution, human urine and serum by electroanalytical techniques on glassy carbon electrode(GCE). The cyclic voltammetry(CV) experiments showed an irreversible oxidation peak at t 1.06 V in 0.1 mol/L BRBS(p H ? 2.0) at 50 m V/s. Different voltammetric scan rates(from 10 to 250 m V/s) suggested that the oxidation of SFD on the GCE was a diffusioncontrolled process. Square-wave voltammetry(SWV) method under optimized conditions showed a linear response to SFD from 5.0 to 74.7 μmol/L(R ? 0.999) with detection and quantification limits of 0.92 and3.10 μmol/L, respectively. The developed SWV method showed better results for detection limit and linear range than the chronoamperometry method. It has been successfully applied to determine SFD concentration in pharmaceutical formulation, human urine and serum samples with recovery close to 100%. 展开更多
关键词 SQUARE-WAVE voltammetry SULFANILAMIDE glassy carbon electrode Biological FLUIDS
下载PDF
Voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine 被引量:1
4
作者 Eliziana S. Gomes Fernando R.F. Leite +2 位作者 Bruno R.L. Ferraz Henrique A.J.L. Mourao Andrea R. Malagutti 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2019年第5期347-357,共11页
A voltammetric sensor based on the electropolymerization of cobalt-poly(methionine)(Co-poly(Met)) on a glassy carbon electrode (GCE) was developed and applied for the determination of estriol by differential pulse vol... A voltammetric sensor based on the electropolymerization of cobalt-poly(methionine)(Co-poly(Met)) on a glassy carbon electrode (GCE) was developed and applied for the determination of estriol by differential pulse voltammetry (DPV) for the first time. The electrochemical properties of the Co-poly(Met)/GCE were analysed by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to characterize the polymers on the GCE surface. The deposition of the Co-poly(Met) film on the GCE surface enhanced the sensor electronic transfer. CV studies revealed that estriol exhibits an irreversible oxidation peak at t0.58 V for the Co-poly(Met)/GCE (vs. Ag/AgCl reference electrode) in 0.10 mol/L Britton-Robinson buffer solution (pH=7.0). Different voltammetric scan rates (10-200 mV/s) suggested that the estriol oxidation on the Co-poly(Met)/GCE surface is controlled by adsorption and diffusion processes. Based on the optimized DPV conditions, the linear responses for estriol quantification were from 0.596 μmol/L to 4.76 μmol/L (R2 =0.996) and from 5.66 μmol/L to 9.90 μmol/L (R2 =0.994) with a limit of detection (LOD) of 0.0340 μmol/L and a limit of quantification (LOQ) of 0.113 μmol/L. The DPV-Co-poly(Met)/GCE method provided good intra-day and inter-day repeatability with RSD values lower than 5%. Also, no interference of real sample matrices was observed on the estriol voltammetric response, making the DPV-Copoly( Met)/GCE highly selective for estriol. The accuracy test showed that the estriol recovery was in the ranges 96.7%-103% and 98.7%-102% for pharmaceutical tablets and human urine, respectively. The estriol quantification in pharmaceutical tablets performed by the Co-poly(Met)/GCE-assisted DPV method was comparable to the official analytical protocols. 展开更多
关键词 ESTRIOL ELECTROANALYSIS Differential pulse voltammetry Cobalt-poly(methionine) film-modified glassy carbon electrode
下载PDF
Voltammetric quantitation of nitazoxanide by glassy carbon electrode
5
作者 Rajeev Jain Rajeev Kumar Yadav Jahangir Ahmad Rather 《Journal of Pharmaceutical Analysis》 SCIE CAS 2013年第6期452-455,共4页
The present study reports voltammetric reduction of nitazoxanide in Britton-Robinson (B-R) buffer by cyclic and square-wave voltammetry at glassy carbon electrode. A versatile fully validated voltammetric method for... The present study reports voltammetric reduction of nitazoxanide in Britton-Robinson (B-R) buffer by cyclic and square-wave voltammetry at glassy carbon electrode. A versatile fully validated voltammetric method for quantitative determination of nitazoxanide in pharmaceutical formulation has been proposed. A squrewave peak current was linear over the nitazoxanide concentration in the range of 20-140 ~tg/mL. The limit of detection (LOD) and limit of quantification (LOQ) was calculated to be 5.23 la~/mL and 17.45 la~/mL, respectively. 展开更多
关键词 NITAZOXANIDE Squarewave voltammetry glassy carbon electrode Pharmaceuticalformulation
下载PDF
The Electrochemical Behavior and the Determination of Bavistin on Glassy Carbon Electrode
6
作者 Yuan Zhe PIAO Gui Fen WANG(Department of Chemistry, Yanbian University, Yani 133002) 《Chinese Chemical Letters》 SCIE CAS CSCD 1998年第8期747-748,共2页
In this paper, the electrochendcal behavior of bavistin (MBC) on glassy carbon electrode is reported. In a base solution of pH=9.0 NH3-NH4Cl, a sensitive anodic peak was found by cyclic voltammetry. Differential pulse... In this paper, the electrochendcal behavior of bavistin (MBC) on glassy carbon electrode is reported. In a base solution of pH=9.0 NH3-NH4Cl, a sensitive anodic peak was found by cyclic voltammetry. Differential pulse stripping voltanunetry was applied for determing MBC in grains. The detection limit is 4×10-8mo/L.The recovery is from 91.3% to 95.7%. The method has advantages of simplicity and high sensitivity. 展开更多
关键词 bavistin glassy carbon electrode cyclic voltammetry differential pulse stripping voltammetry PESTICIDE
下载PDF
Electrochemical behavior of paclitaxel and its determination at glassy carbon electrode
7
作者 Jayant I.Gowda Sharanappa T.Nandibewoor 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2014年第1期42-49,共8页
The electrochemical behavior of paclitaxel drug was studied at a glassy carbon electrode in phosphate buffer solutions using cyclic and differential-pulse voltammetric techniques.The oxidation process was shown to be ... The electrochemical behavior of paclitaxel drug was studied at a glassy carbon electrode in phosphate buffer solutions using cyclic and differential-pulse voltammetric techniques.The oxidation process was shown to be irreversible over the pH range(3.0e10.4)and was diffusion controlled.Effects of anodic peak potential(E_(p)),anodic peak current(Ipa),scan rate,pH,heterogeneous rate constant(k^(0)),etc have been discussed.A possible electrooxidation mechanism was proposed.An analytical method was developed for the determination of paclitaxel in phosphate buffer solution at pH¼7.0 as a supporting electrolyte.The anodic peak current varied linearly with paclitaxel concentration in the range 1.0×10^-(6)M to 1.0×10^-(5)M with a limit of detection(LOD)of 1.23×10^(-8)M and limit of quantification(LOQ)of 4.10×10^(-8)M.The proposed method was successfully applied to the determination of paclitaxel in pure and real samples. 展开更多
关键词 PACLITAXEL glassy carbon electrode voltammetry Injection analysis URINE
下载PDF
Electrochemical Behavior of Chalcone at a Glassy Carbon Electrode and Its Analytical Applications
8
作者 Keerti M. Naik Sharanappa T. Nandibewoor 《American Journal of Analytical Chemistry》 2012年第9期656-663,共8页
A simple and rapid method was developed using cyclic, differential pulse and square wave voltammetric techniques for the determination of trace-level chalcone at a glassy carbon electrode. Chalcone could produce two a... A simple and rapid method was developed using cyclic, differential pulse and square wave voltammetric techniques for the determination of trace-level chalcone at a glassy carbon electrode. Chalcone could produce two anodic peaks at about 0.514 V and 1.478 V and a cathodic peak at about -0.689 V. The differential pulse voltammerty presents a good linear response as compared to square wave voltammetry in the range of 0.2 - 10 μM with a detection limit of 0.18 μM. The proposed method was used successfully for its quantitative determination in spiked human plasma and urine as real samples. 展开更多
关键词 CHALCONE voltammetry glassy carbon electrode ELECTROCHEMICAL Determination Oxidation
下载PDF
Determination of captopril in patient human urine using ferrocenemonocarboxylic acid modified carbon nanotubes paste electrode 被引量:2
9
作者 Mohammad A.Khalilzadeh Hassan Karimi-Maleh +2 位作者 Azra Amiri Fathali Gholami Robabeh Motaghed Mazhabi 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第12期1467-1470,共4页
In this work,we describe a new strategy for the electrochemical determination of captopril(CA) using ferrocenemonocarboxylic acid as a mediator and multiwall carbon nanotubes as sensors in aqueous solution at pH 7.0... In this work,we describe a new strategy for the electrochemical determination of captopril(CA) using ferrocenemonocarboxylic acid as a mediator and multiwall carbon nanotubes as sensors in aqueous solution at pH 7.0.The diffusion coefficient(D),and the kinetic parameters such as electron transfer coefficient(α).and heterogeneous rate constant(kh),for CA were also determined using electrochemical approaches.Under the optimized conditions,the electrocatalytic oxidation peak current of captopril showed two linear dynamic ranges with a detection limit of 0.3×10^-6 mol L^-1 captopril.The linear calibration range was 0.8×10^(-6) to 65×10^-6 mol L^-1 using cyclic voltammetry.Finally,this modified electrode was also examined as a selective,simple and precise new electrochemical sensor for the determination of captopril in real samples such as drug and patient human urine. 展开更多
关键词 Captopril determination carbon nanotubes paste electrode Ferrocenemonocarboxylic acid ELECTROCATALYTIC voltammetry
下载PDF
Electrocatalytic oxidation of hydrazine with alizarin red S as a homogenous mediator on the glassy carbon electrode
10
作者 Mohammad Mazloum-Ardakani Roya Mazidi +2 位作者 Mohammad Hossein Mashhadizadeh Parvanah Rahimi Mohammad Ali Karimi 《Science China Chemistry》 SCIE EI CAS 2010年第5期1194-1200,共7页
Electro-catalytic oxidation and detection of hydrazine on a glassy carbon electrode,at pH 6.0,was studied by using alizarin red S as a homogeneous mediator.The overall number of electrons involved in the catalytic oxi... Electro-catalytic oxidation and detection of hydrazine on a glassy carbon electrode,at pH 6.0,was studied by using alizarin red S as a homogeneous mediator.The overall number of electrons involved in the catalytic oxidation of hydrazine and that involved in the rate-determining step were four and one,respectively.The interfering effect of some cations,anions and organic compounds were examined.Peak current for this process varied linearly with the square root of the scan rate.The kinetic parameters,such as the electron transfer coefficient(α) and catalytic rate constant(k) ,were determined using cyclic voltammetry,linear sweep voltammetry and chronoamperometry.The electro-catalytic response was optimized with regards to the pH,scan rate,hydrazine concentration and other variables. 展开更多
关键词 ALIZARIN red S HYDRAZINE glassy carbon electrode electro-catalytic oxidation voltammetry
原文传递
Voltammetric Detection of Nanomolar Levels of Hypoxanthine in the Presence of Copper(Ⅱ) at Glassy Carbon Electrode
11
作者 Hu Shengshui Cui Dafu Marco Mascini 《Wuhan University Journal of Natural Sciences》 CAS 1999年第1期101-104,共4页
Nanomolar levels of the hypoxanthine in NaOH electrolyte cantaining copper(Ⅱ) can be determined by anodic stripping voltammetry at a glassy carbon electrode. In the present article hypoxanthine Cu + is shown to be ... Nanomolar levels of the hypoxanthine in NaOH electrolyte cantaining copper(Ⅱ) can be determined by anodic stripping voltammetry at a glassy carbon electrode. In the present article hypoxanthine Cu + is shown to be adsorbed on the electrode surface in the presence of an excess of copper(Ⅱ). After accumulation period, hypoxanthine Cu + was stripped from the electrode surface and the anodic current coming near to the oxidation of Cu(Ⅰ) to Cu(Ⅱ) was measured. A linear calibration curve in the range of 5 nmol/L 1.5 mmol/L hypoxanthine, with a detection limit of 0.5 nmol/L hypoxanthine were obtained. 展开更多
关键词 HYPOXANTHINE COPPER glassy carbon electrode stripping voltammetry
下载PDF
Stripping Voltammetric Determination of Uranium in Water Samples Using Hg-Thin Film Modified Multiwall Carbon Nanotube Incorporated Carbon Paste Electrode
12
作者 S. Sahoo A. K. Satpati A. V. R. Reddy 《American Journal of Analytical Chemistry》 2013年第3期141-147,共7页
The variables affecting determination of ultra trace levels of uranium (VI) in aqueous samples by differential pulse cathodic stripping voltammetry were examined in detail using Hg-thin film modified carbon paste and ... The variables affecting determination of ultra trace levels of uranium (VI) in aqueous samples by differential pulse cathodic stripping voltammetry were examined in detail using Hg-thin film modified carbon paste and multiwall carbon nanotube (MWCNT) incorporated carbon paste electrode. Carbon paste electrode prepared in the laboratory was modified with Hg thin film and used as the working electrode. MWCNT was incorporated into the carbon paste for enhancement in sensitivity of the measurements. Electrochemical response for the uranium (VI) reduction peak was found to be well resolved on the thin mercury film modified carbon paste surface and also with the MWCNT modification. Characteristics of the adsorption preconcentration process were investigated using electrochemical impedance measurements. Electrochemical signals were observed to be enhanced on MWCNT modification of the carbon paste. 展开更多
关键词 URANIUM carbon PASTE electrode Chloranilic acid (CAA) MWCNT voltammetry IMPEDANCE
下载PDF
Use of Graphene and Cucurbit[7]uril Electrodes for the Determination of Amantadine in Biological Fluids 被引量:2
13
作者 C. S. H. Domínguez P. Hernández 《American Journal of Analytical Chemistry》 2015年第7期623-630,共8页
A differential pulse voltammetry (DPV) method for amantadine (AT) determination is developed. To this end, all the chemical and instrumental variables affecting the determination of amantadine are optimized. These stu... A differential pulse voltammetry (DPV) method for amantadine (AT) determination is developed. To this end, all the chemical and instrumental variables affecting the determination of amantadine are optimized. These studies have used three types of glassy-carbon electrode, first electrode which has not undergone surface modification or coating, to then modify the working electrode surface with two kinds of suspensions: graphene and graphene-cucurbit[7]uril (CB[7]). From studies of the mechanisms governing the electrochemical response of amantadine, it was concluded that it is an electrochemically system with a diffusive reduction phenomenon. Under optimal conditions and with the appropriate electrode modification, we proceed to study the relation between the peak intensity with the analyte concentration. Thus, we find that when the electrode surface is covered with graphene-CB[7], two linear sections are obtained, the first one in the concentration range of between 0.05 μg·mL﹣1 and 0.75 μg·mL﹣1;and the second one between 1.00 μg·mL﹣1 and 6.00 μg·mL﹣1, with Er (%) = 87 and R.S.D. = 0.94% (n = 10 at 0.5 μg·mL﹣1 level). The minimum detectable amount was 15 ng·mL﹣1 while a concentration of 44 ng·mL﹣1 was calculated as determination limit. The optimized method was applied to the determination of amantadine in biological fluids. 展开更多
关键词 glassy-carbon electrode AMANTADINE Differential Pulse voltammetry Human URINE
下载PDF
基于氮掺杂介孔碳修饰玻碳微球糊电极的双酚A电化学传感器的构建及性能研究
14
作者 贺嘉夫茹孜 马伟平 李永红 《广州化工》 CAS 2024年第14期35-38,81,共5页
制备了一种由氮掺杂介孔碳修饰的玻碳微球糊电极,用于双酚A的灵敏、快速检测。利用循环伏安法对修饰电极进行了表征,采用方波伏安法研究了双酚A在修饰电极上的电化学行为;根据不同扫速下峰电流与扫速的关系讨论了双酚A在电极表面的反应... 制备了一种由氮掺杂介孔碳修饰的玻碳微球糊电极,用于双酚A的灵敏、快速检测。利用循环伏安法对修饰电极进行了表征,采用方波伏安法研究了双酚A在修饰电极上的电化学行为;根据不同扫速下峰电流与扫速的关系讨论了双酚A在电极表面的反应过程。在最优的实验条件下,双酚A的响应电流与浓度在0.3~2μM和2~30μM范围内时呈线性关系,检测限是0.01μM(S/N=3)。该方法具有良好的重现性和抗干扰性,可用于实际样品的检测,样品回收率为97.5%~101.5%。 展开更多
关键词 双酚A 氮掺杂介孔碳 玻碳微球糊电极 方波伏安法 循环伏安法 电化学传感器
下载PDF
Aptasensor Based on Screen-Printed Carbon Electrodes Modified with CS/AuNPs for Sensitive Detection of Okadaic Acid in Shellfish 被引量:2
15
作者 Ni Zeng Xinyi Wang +4 位作者 Yiyang Dong Yan Yang Yingai Yin Lianhui Zhao Xu Wang 《Journal of Analysis and Testing》 EI CSCD 2023年第2期128-135,共8页
Okadaic acid(OA),a small molecule substance derived from shellfish,is one of the most widely distributed marine toxins with acute symptoms of vomiting and diarrhea after accidental ingestion.For this,there is an urgen... Okadaic acid(OA),a small molecule substance derived from shellfish,is one of the most widely distributed marine toxins with acute symptoms of vomiting and diarrhea after accidental ingestion.For this,there is an urgently need for sensitive and reliable methods to detect OA in real shellfish samples.In this study,a simple aptasensor based on screen-printed carbon electrode(SPCE)with modification of chitosan(CS)and gold nanoparticles(Au NPs)was designed for electrochemical determination of OA,and the electrode surface was modified with Au NPs by potential-sweeping electrodeposition,which greatly improved the electrochemical response.The entire detection and characterization process were carried out by cyclic voltammetry(CV)with a linear correlation in the range of 0.01-100 ng/m L and a limit of detection(LOD)of 6.7 pg/m L.Furthermore,recovery rates of 92.3-116%were obtained demonstrating excellent accuracy through the recovery trial of mussel and scallop samples. 展开更多
关键词 Okadaic acid APTASENSOR Screen-printed carbon electrode CHITOSAN Gold nanoparticles Cyclic voltammetry
原文传递
Simultaneous determination of cysteamine and folic acid in pharmaceutical and biological samples using modified multiwall carbon nanotube paste electrode 被引量:6
16
作者 Ali Taherkhani Hassan Karimi-Maleh +4 位作者 Ali A.Ensafi Hadi Beitollahi Ahmad Hosseini Mohammad A.Khalilzadeh Hassan Bagheri 《Chinese Chemical Letters》 SCIE CAS CSCD 2012年第2期237-240,共4页
A carbon paste electrode(CPE) chemically modified with multiwall carbon nanotubes and ferrocene(FC) was used as a selective electrochemical sensor for the simultaneous determination of trace amounts of cysteamine... A carbon paste electrode(CPE) chemically modified with multiwall carbon nanotubes and ferrocene(FC) was used as a selective electrochemical sensor for the simultaneous determination of trace amounts of cysteamine(CA) and folic acid(FA).This modified electrode showed very efficient electrocatalytic activity for the anodic oxidation of CA.The peak current of differential pulse voltammograms of CA and FA increased linearly with their concentration in the ranges of 0.7-200μmol/L CA and 5.0- 700μmol/L FA.The detection limits for CA and FA were 0.3μmol/L and 2.0μmoI/L,respectively.The diffusion coefficient(D) and transfer coefficient(α) of CA were also determined.These conditions are sufficient to allow determination of CA and FA both individually and simultaneously. 展开更多
关键词 Cysteamine Folic acid carbon nanotube paste electrode voltammetry
原文传递
碳纳米管修饰电极对多巴胺和抗坏血酸的电催化氧化 被引量:34
17
作者 赫春香 赵常志 +2 位作者 唐祯安 邱介山 王立鼎 《分析化学》 SCIE EI CAS CSCD 北大核心 2003年第8期958-960,共3页
研究了碳纳米管修饰玻碳电极 (NTCME)的制备方法及对多巴胺 (DA)和抗坏血酸 (AA)的电催化氧化作用。在磷酸盐缓冲溶液 (PBSpH 7.4)中 ,以NTCME为工作电极时 ,DA与AA的氧化电位分别为 0 .2 6和 0 .0 1V(vs.SCE) ,比在裸玻碳电极 (GC)上... 研究了碳纳米管修饰玻碳电极 (NTCME)的制备方法及对多巴胺 (DA)和抗坏血酸 (AA)的电催化氧化作用。在磷酸盐缓冲溶液 (PBSpH 7.4)中 ,以NTCME为工作电极时 ,DA与AA的氧化电位分别为 0 .2 6和 0 .0 1V(vs.SCE) ,比在裸玻碳电极 (GC)上分别降低了 0 .0 7和 0 .6 2V。NTCME能消除DA与AA共存时测定的相互干扰。利用二阶导数卷积伏安法测定 ,DA与AA分别在 2 .0 0× 10 - 6~ 3.84× 10 - 4 和 7.99× 10 - 5~ 3.6 6× 10 - 3 mol L浓度范围内 ,峰高与浓度呈线性关系 ;检出限分别为 1.90× 10 - 7和 5 .96× 10 - 5mol L。 展开更多
关键词 碳纳米管 修饰电极 多巴胺 抗坏血酸 电催化氧化 二阶导数卷积伏安法 电化学分析
下载PDF
尼群地平在玻碳电极上的伏安行为及应用 被引量:13
18
作者 刘永明 李桂芝 荆济荣 《分析化学》 SCIE EI CAS CSCD 北大核心 2002年第11期1341-1343,共3页
在pH 7.0Britton Robinson缓冲溶液中 ,尼群地平在玻碳电极上有一灵敏的还原峰 ,峰电位为 -0 .71V(vs.Ag AgCl)。当尼群地平浓度在 1 .0× 1 0 - 6 ~ 1 .0× 1 0 - 5mol L范围内时与峰电流呈线性关系 ,据此测定了片剂及尿样中... 在pH 7.0Britton Robinson缓冲溶液中 ,尼群地平在玻碳电极上有一灵敏的还原峰 ,峰电位为 -0 .71V(vs.Ag AgCl)。当尼群地平浓度在 1 .0× 1 0 - 6 ~ 1 .0× 1 0 - 5mol L范围内时与峰电流呈线性关系 ,据此测定了片剂及尿样中尼群地平的含量 ,取得满意结果。用线性扫描与循环伏安法探讨了该体系的伏安行为 ,结果表明 。 展开更多
关键词 伏安行为 尼群地平 线性扫描伏安法 玻碳电极 抗高血压药物 分析 片剂 尿样
下载PDF
纳米金修饰玻碳电极在抗坏血酸共存下选择性测定去甲肾上腺素 被引量:28
19
作者 张宏 金葆康 《分析化学》 SCIE EI CAS CSCD 北大核心 2002年第11期1285-1288,共4页
利用电沉积的方法制得纳米金修饰玻碳电极 ,该修饰电极对去甲肾上腺素 (NE)氧化反应有催化作用。去甲肾上腺素在纳米金修饰玻碳电极上有很强的吸附作用。研究了磷酸缓冲溶液的pH值和浓度对NE的电化学行为的影响。从去甲肾上腺素和抗坏... 利用电沉积的方法制得纳米金修饰玻碳电极 ,该修饰电极对去甲肾上腺素 (NE)氧化反应有催化作用。去甲肾上腺素在纳米金修饰玻碳电极上有很强的吸附作用。研究了磷酸缓冲溶液的pH值和浓度对NE的电化学行为的影响。从去甲肾上腺素和抗坏血酸在纳米金修饰电极的循环伏安图上可观察到两个明显分开的氧化峰 ,峰电位差达到 1 3 1mV ,因此 ,可利用该修饰电极在抗坏血酸存在下选择性测定去甲肾上腺素 ,线性范围为 1× 1 0 - 4 ~5× 1 0 - 6 mol L。 展开更多
关键词 选择性测定 纳米金 玻碳电极 循环伏安 去甲肾上腺素 抗坏血酸 修饰电极 神经递质 活体检测
下载PDF
玻碳电极吸附循环伏安法测定维生素B_2 被引量:13
20
作者 杨培慧 周志军 +1 位作者 冯德雄 叶晓云 《暨南大学学报(自然科学与医学版)》 CAS CSCD 2001年第5期93-97,共5页
目的 :研究维生素B2 在玻碳电极表面吸附的电化学行为及定量分析方法 .方法 :玻碳电极在 8.0mol/LHNO3 介质中 ,于 + 0 .6~ + 2 .0V (vs.SCE)的电位范围内进行循环扫描电活化后 ,维生素B2 在电极表面具有很强的吸附性 ,在底液为 0 .0 5... 目的 :研究维生素B2 在玻碳电极表面吸附的电化学行为及定量分析方法 .方法 :玻碳电极在 8.0mol/LHNO3 介质中 ,于 + 0 .6~ + 2 .0V (vs.SCE)的电位范围内进行循环扫描电活化后 ,维生素B2 在电极表面具有很强的吸附性 ,在底液为 0 .0 5mol/L柠檬酸 + 0 .1mol/LNa2 HPO4 (pH =4 .9)的介质中 ,吸附电位 - 0 .3V ,在 0~ - 0 .7V的范围内 ,以 90mV/s的速度进行循环伏安扫描 .结果 :实验表明VB2 在电极表面具有可逆吸附波的特征 ,VB2 浓度与峰电流在 6.0× 10 - 8~ 7.0× 10 - 6 mol/L之间成线性关系 ,检测限为 1.0× 10 - 8mol/L .结论 :建立了维生素B2 在玻碳电极表面的电化学分析方法 ,将该法运用于实际样品药片中VB2 含量的测定 ,获得满意的结果 . 展开更多
关键词 维生素B2 玻碳电极 循环伏安法 含量测定 电化学分析 吸附性 药片测定
下载PDF
上一页 1 2 18 下一页 到第
使用帮助 返回顶部