期刊文献+
共找到63,055篇文章
< 1 2 250 >
每页显示 20 50 100
Effects of plasma β-endorphin on hemorrhagic shock in acute hypoxic rats
1
作者 高京生 田景亮 刘燕 《Journal of Medical Colleges of PLA(China)》 CAS 1992年第2期169-172,共4页
Forty rots were randomized into 2 groups and naloxone or saline were injected to therats after they were inflicted with hemorrhagic shock at sea level and at a simulated altitude of4000m respectively to observe the ef... Forty rots were randomized into 2 groups and naloxone or saline were injected to therats after they were inflicted with hemorrhagic shock at sea level and at a simulated altitude of4000m respectively to observe the effects of naloxone on left ventricular systolic pressure(LVSP),left ventricular diastolic pressure(LVDP),the maximal changing rate of LVSP(dp/dt max),heartrate(HR),and survival time of the animals.Plasma β-endorphin(β-EP)was determined beforeand after hemorrhage to observe the relationship between β-EP and hemorrhagic shock.It wasfound that the circulatory parameters of hemorrhagic shock changed more markedly at high alti-tude than at sea level,naloxone could restore these parameters and prolong the survival time inboth the animals of the sea level and high altitude groups,and plasma β-EP level was elevatedafter hemorrhage especially in those animals at high altitude.These findings indicate:(1)Hemorrhagic shock at high altitude is usually accompanied with severe clinical manifestations,rapid progression,and high mortality.(2)β-EP seems to participate in the pathologicalmanifestafions of hemorrhagic shock at high altitude,and its depressive action on myocardialcontraction may be one of the factors inducing hemorrhagic shock.(3)Naloxone possesses defi-nite property to comet hemorrhagic shock at high altitude. 展开更多
关键词 HEMORRHAGIC shock ALTITUDE survival NALOXONE Β-endorphin animal RATS
下载PDF
Plasma β-Endorphin Levels in Women with Early Threatened Abortion before and after the Treatment of Integrated Chinese and Western Medicine
2
作者 SUN Fei(孙斐) YU Jin (俞瑾) 《Journal of Reproduction and Contraception》 CAS 1999年第1期12-17,共6页
To observe plasm a β-endorphin (β-EP) and gonadotrophin releasing horm one (GnRH), hum an chorionic gonadotrophin (hCG), progesterone (P4) levelsin w om en w ith early threatened abortion and w ith a history of re... To observe plasm a β-endorphin (β-EP) and gonadotrophin releasing horm one (GnRH), hum an chorionic gonadotrophin (hCG), progesterone (P4) levelsin w om en w ith early threatened abortion and w ith a history of recurrent spontaneous abortions (RSA). Tw enty patientsw ith threatened abortion at7~8 w eeksof gestation w ere re- cruited, allof them had a history of 3 or m ore recurrentunexplained abortions. They w ere treated w ith psychologicalconsultation accompanied by traditionalChinese herbs. Blood samples w ere taken to m easure β-EP, GnRH, hCG and P4 levels by radioim - m unoassay (RIA). The treatm ents w ere continued till10~12 w eeks, blood w astaken during this period to compare changes in these peptides / horm ones. Tw enty norm al pregnantw om en at7~8 and 10~12 w eeksand 20 patientsw ith incompleteabortion at 10~12 w eeksw ererecruited for comparativestudies. Results: (1) In norm alpregnant w om en, plasm a β-EP, GnRH, hCGand P4 levelsat10~12 w eeksw ere significantly higher than thatat7~8 w eeks (P< 0.01). (2) In patients w ith threatened abortion and a history of RSA, plasm a β-EP levels at7~8 w eeks w ere significantly higher than those of norm al pregnantw om en (P< 0.01); on the contrary, plasm a GnRH, hCGand P4 levelsin these patientsw ere significantly low er than thosein norm alcases (P< 0.01). After treatm ent, 16 of the 20 patients succeeded in m aintaining their pregnancies, the levels of the four plasm a contents at10~12 w eeks w ere sim ilar to thosein norm alpregnantw om en (P> 0.05). (3) Plasm a β-EPlevelsin patientsw ith incomplete abortionsat10~12 w eeksw ere dram atically higher and GnRH, hCGand P4 levelsw ere low er than in norm alpregnantw om en (P< 0.01). β-EP m ightplay a role in the pathophysiology of spontaneousabortion. 展开更多
关键词 Threatened abortion Β-endorphin Gonadotrophin releasing horm one (GnRH) Hum an chorionic gonadotrophin(hCG) Progesterone(P4)
下载PDF
The effect of low frequency electromagnetic field on plasma β-endorphin in human brain
3
作者 ZHOU Wei dong,YIN Jing hai Electronic Engineering Department, Shandong University, Jinan 250100, China, E mail: wdzhou@usa.net 《Chinese Journal of Biomedical Engineering(English Edition)》 2000年第2期92-94,共3页
The effect of electromagnetic field on plasma β endorphin in 30 patients with migraine were studied in the experiment. All subjects received a 20 minute repetitive transcranial magnetic stimulation (Frequency 10Hz, A... The effect of electromagnetic field on plasma β endorphin in 30 patients with migraine were studied in the experiment. All subjects received a 20 minute repetitive transcranial magnetic stimulation (Frequency 10Hz, Average intensity 8mT) per time, and the total experiment lasted 20 times. Before and after the experiment, the EEG and plasma β endorphin were tested. The results show that the level of plasma β endorphin in patients blood increased significantly from (73.486±26.002)mg/ml to (116.934±67.592)mg/ml (p<0.01), and the EEG average magnitude of the migraine patients were improved obviously from 41.77μV to 47.42μV. 展开更多
关键词 ELECTROMAGNETIC FIELD TRANSCRANIAL magnetic stimulation(TMS) athermal biological EFFECT MIGRAINE Β-endorphin
下载PDF
Study of plasma parameters of coaxial plasma source using triple Langmuir probe and Faraday cup diagnostics
4
作者 Sunil KANCHI Rohit SHUKLA Archana SHARMA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期94-100,共7页
Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In... Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In this work, a 120° opening angle of CPG nozzle is used as a plasma gun configuration that operates at the energy of 150 J. The ionization of polyethylene insulator between the electrodes of the gun produces a cloud of hydrogen and carbon plasma.The triple Langmuir probe and Faraday cup are used to measure plasma density and plasma temperature. These methods are used to measure the on-axis and off-axis plasma divergence of the coaxial plasma gun. The peak values of ion densities measured at a distance of 25 mm on-axis from the plasma gun are(1.6±0.5)×10^(19)m^(-3)and(2.8±0.6)×10^(19)m^(-3)for hydrogen and carbon plasma respectively and the peak temperature is 3.02±0.5 eV. The mean propagation velocity of plasma is calculated using the transit times of plasma at different distances from the plasma gun and is found to be 4.54±0.25 cm/μs and 1.81±0.18 cm/μs for hydrogen and carbon plasma respectively. The Debye radius is obtained from the measured experimental data that satisfies the thin sheath approximation. The shot-to-shot stability of plasma parameters facilitates the use of plasma guns in laboratory experiments. These types of plasma sources can be used in many applications like plasma opening switches, plasma devices, and as plasma sources. 展开更多
关键词 coaxial plasma source triple Langmuir probe Faraday cup plasma density plasma temperature
下载PDF
Final results of the first phase of the PROTO-SPHERA experiment: obtainment of the full current stable screw pinch and first evidences of the jet + torus combined plasma configuration
5
作者 Paolo MICOZZI Franco ALLADIO +21 位作者 Alessandro MANCUSO Vincenzo ZANZA Gerarda APRUZZESE Francesca BOMBARDA Luca BONCAGNI Paolo BURATTI Francesco FILIPPI Giuseppe GALATOLA TEKA Francesco GIAMMANCO Edmondo GIOVANNOZZI Andrea GROSSO Matteo IAFRATI Alessandro LAMPASI Violeta LAZIC Simone MAGAGNINO Simone MANNORI Paolo MARSILI Valerio PIERGOTTI Giuliano ROCCHI Alessandro SIBIO Benedetto TILIA Onofrio TUDISCO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期31-43,共13页
In astrophysics, the boundary conditions for plasma phenomena are provided by nature and the astronomer faces the problem of understanding them from a variety of observations [Hester J J et al 1996 Astrophys. J. 456 2... In astrophysics, the boundary conditions for plasma phenomena are provided by nature and the astronomer faces the problem of understanding them from a variety of observations [Hester J J et al 1996 Astrophys. J. 456 225], on the other hand, in laboratory plasma experiments the electromagnetic boundary conditions become a major problem in the set-up of the machine that produces the plasma, an issue that has to be investigated step by step and to be modified and adapted with great patience, in particular in the case of an innovative plasma confinement experiment. The PROTO-SPHERA machine [Alladio F et al 2006 Nucl. Fusion 46 S613] is a magnetic confinement experiment, that emulates in the laboratory the jet + torus plasma configurations often observed in astrophysics: an inner magnetized jet of plasma centered on the(approximate) axis of symmetry and surrounded by a magnetized plasma torus orthogonal to this jet. The PROTO-SPHERA plasma is simply connected, i.e., no metal current conducting rod is linked to the plasma torus, while instead it is the inner magnetized plasma jet(in the following always called the plasma centerpost) that is linked to the torus. It is mandatory that no spurious plasma current path modifies the optimal shape of the plasma centerpost. Moreover, as the plasma torus is produced and sustained, in absence of any applied inductive electric field, by the inner plasma centerpost through magnetic reconnections [Taylor J B and Turner M F 1989 Nucl.Fusion 29 219], it is required as well that spurious current paths do not surround the torus on its outboard, in order not to lower the efficiency of the magnetic reconnections that maintain the plasma torus at the expense of the plasma centerpost. Boundary conditions have been corrected,up to the point that the first sustainment in steady state has been achieved for the combined plasma. 展开更多
关键词 laboratory plasmas magnetic confinement astrophysical plasmas
下载PDF
The multi-peak point phenomenon of broadband microwave reflection caused by inhomogeneous plasma
6
作者 杨敏 齐凯旋 +5 位作者 杨玖文 贾飒 刘浩岩 陈燕扬 李瑾 李小平 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期1-11,共11页
During spacecraft re-entry,the challenge of measuring plasma sheath parameters directly contributes to difficulties in addressing communication blackout.In this work,we have discovered a phenomenon of multiple peaks i... During spacecraft re-entry,the challenge of measuring plasma sheath parameters directly contributes to difficulties in addressing communication blackout.In this work,we have discovered a phenomenon of multiple peaks in reflection data caused by the inhomogeneous plasma.Simulation results show that the multi-peak points fade away as the characteristic frequency is approached,resembling a series of gradually decreasing peaks.The positions and quantities of these points are positively correlated with electron density,yet they show no relation to collision frequency.This phenomenon is of significant reference value for future studies on the spatial distribution of plasmas,particularly for using microwave reflection signals in diagnosing the plasma sheath. 展开更多
关键词 plasma sheath microwave reflection inhomogeneous plasma
下载PDF
Experimental confirmation of the linear relation between plasma current and external vertical magnetic field in EXL-50 spherical torus energetic electron plasmas
7
作者 董力立 王明远 +9 位作者 刘文军 石跃江 董家齐 郭栋 孙恬恬 顾翔 宋显明 袁保山 彭元凯 the ENN Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期32-36,共5页
A three-fluid equilibrium plasma with bulk plasma and energetic electrons has been observed on the Xuanlong-50(EXL-50) spherical torus, where the energetic electrons play a crucial role in sustaining the plasma curren... A three-fluid equilibrium plasma with bulk plasma and energetic electrons has been observed on the Xuanlong-50(EXL-50) spherical torus, where the energetic electrons play a crucial role in sustaining the plasma current and pressure. In this study, the equilibrium of a multi-fluid plasma was investigated by analyzing the relationship between the external vertical magnetic field(B_(V)),plasma current(I_(p)), the poloidal ratio(β_(p)) and the Shafranov formula. Remarkably, our research demonstrates some validity of the Shafranov formula in the presence of multi-fluid plasma in EXL-50 spherical torus. This finding holds significant importance for future reactors as it allows for differentiation between alpha particles and background plasma. The study of multi-fluid plasma provides a significant reference value for the equilibrium reconstruction of burning plasma involving alpha particles. 展开更多
关键词 plasma equilibrium Shafranov formula multi-fluid plasma
下载PDF
Effect of matrix thermal properties on laser-induced plasma
8
作者 Yuheng Shan An Li +4 位作者 Xinyu Zhang Wen Yi Ying Zhang Xiaodong Liu Ruibin Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第10期331-336,共6页
The matrix thermal properties have an important impact on laser-induced plasma,as the thermal effect dominates the interaction between ns-pulsed laser and matter,especially in metals.We used a series of pure metals an... The matrix thermal properties have an important impact on laser-induced plasma,as the thermal effect dominates the interaction between ns-pulsed laser and matter,especially in metals.We used a series of pure metals and aluminum alloys to measure plasma temperature and electron density through laser-induced breakdown spectroscopy,in order to investigate the effect of matrix thermal properties on laser-induced plasma.In pure metals,a significant negative linear correlation was observed between the matrix thermal storage coefficient and plasma temperature,while a weak correlation was observed with electron density.The results indicate that metals with low thermal conductivity or specific heat capacity require less laser energy for thermal diffusion or melting and evaporation,resulting in higher ablation rates and higher plasma temperatures.However,considering ionization energy,thermal effects may be a secondary factor affecting electron density.The experiment of aluminum alloy further confirms the influence of thermal conductivity on plasma temperature and its mechanism explanation. 展开更多
关键词 laser-induced plasma thermal properties matrix effect thermal storage coefficient plasma temperature
下载PDF
Tunable energy spectrum betatron x-ray sources in a plasma wakefield
9
作者 奚传易 寿寅任 +4 位作者 韩立琦 阿卜杜伍普尔·阿布力米提 刘晓丹 赵研英 余金清 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期344-350,共7页
X-ray sources with tunable energy spectra have a wide range of applications in different scenarios due to their different penetration depths.However,existing x-ray sources face difficulties in terms of energy regulati... X-ray sources with tunable energy spectra have a wide range of applications in different scenarios due to their different penetration depths.However,existing x-ray sources face difficulties in terms of energy regulation.In this paper,we present a scheme for tuning the energy spectrum of a betatron x-ray generated from a relativistic electron bunch oscillating in a plasma wakefield.The center energy of the x-ray source can be tuned from several keV to several hundred keV by changing the plasma density,thereby extending the control range by an order of magnitude.At different central energies,the brightness of the betatron radiation is in the range of 3.7×10^(22)to 5.5×10^(22)photons/(0.1%BW·s·mm^(2)·mrad^(2))and the photon divergence angle is about 2 mrad.This high-brightness,energy-controlled betatron source could pave the way to a wide range of applications requiring photons of specific energy,such as phase-contrast imaging in medicine,non-destructive testing and material analysis in industry,and imaging in nuclear physics. 展开更多
关键词 betatron plasma physics X-RAY plasma wakefield acceleration(PWFA)
下载PDF
Customized modulation on plasma uniformity by non-uniform magnetic field in capacitively coupled plasma
10
作者 王森 张权治 +2 位作者 马方方 Maksudbek YUSUPOV 王友年 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第6期79-87,共9页
A two-dimensional fluid model based on COMSOL Multiphysics is developed to investigate the modulation of static magnetic field on plasma homogeneity in a capacitively coupled plasma(CCP)chamber. To generate a static m... A two-dimensional fluid model based on COMSOL Multiphysics is developed to investigate the modulation of static magnetic field on plasma homogeneity in a capacitively coupled plasma(CCP)chamber. To generate a static magnetic field, direct current is applied to a circular coil located at the top of the chamber. By adjusting the magnetic field's configuration, which is done by altering the coil current and position, both the plasma uniformity and density can be significantly modulated. In the absence of the magnetic field, the plasma density exhibits an inhomogeneous distribution characterized by higher values at the plasma edge and lower values at the center. The introduction of a magnetic field generated by coils results in a significant increase in electron density near the coils. Furthermore, an increase in the sets of coils improves the uniformity of the plasma. By flexibly adjusting the positions of the coils and the applied current,a substantial enhancement in overall uniformity can be achieved. These findings demonstrate the feasibility of using this method for achieving uniform plasma densities in industrial applications. 展开更多
关键词 COMSOL capacitively coupled plasma plasma uniformity magnetic field
下载PDF
Edge effect during microwave plasma chemical vapor deposition diamond-film:Multiphysics simulation and experimental verification
11
作者 Zhiliang Yang Kang An +7 位作者 Yuchen Liu Zhijian Guo Siwu Shao Jinlong Liu Junjun Wei Liangxian Chen Lishu Wu Chengming Li 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第10期2287-2299,共13页
This study focused on the investigation of the edge effect of diamond films deposited by microwave plasma chemical vapor de-position.Substrate bulge height△h is a factor that affects the edge effect,and it was used t... This study focused on the investigation of the edge effect of diamond films deposited by microwave plasma chemical vapor de-position.Substrate bulge height△h is a factor that affects the edge effect,and it was used to simulate plasma and guide the diamond-film deposition experiments.Finite-element software COMSOL Multiphysics was used to construct a multiphysics(electromagnetic,plasma,and fluid heat transfer fields)coupling model based on electron collision reaction.Raman spectroscopy and scanning electron microscopy were performed to characterize the experimental growth and validate the model.The simulation results reflected the experimental trends observed.Plasma discharge at the edge of the substrate accelerated due to the increase in△h(△h=0-3 mm),and the values of electron density(n_(c)),molar concentration of H(C_(H)),and molar concentration of CH_(3)(C_(CH_(3)))doubled at the edge(for the special concave sample with△h=−1 mm,the active chemical groups exhibited a decreased molar concentration at the edge of the substrate).At=0-3 mm,a high diamond growth rate and a large diamond grain size were observed at the edge of the substrate,and their values increased with.The uniformity of film thickness decreased with.The Raman spectra of all samples revealed the first-order characteristic peak of dia-mond near 1332 cm^(−1).When△h=−1 mm,tensile stress occurred in all regions of the film.When△h=1-3 mm,all areas in the film ex-hibited compressive stress. 展开更多
关键词 microwave plasma chemical vapor deposition edge discharge plasma diamond film
下载PDF
A research on the effect of plasma spectrum collection device on LIBS spectral intensity
12
作者 林晓梅 董艳杰 +5 位作者 林京君 黄玉涛 杨江飞 岳星宇 张倬嘉 段鑫杨 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期121-128,共8页
Only a small amount of spectral information is collected because the collection solid angle of the optical fiber probe and lens is very limited when collecting spectral information.To overcome this limitation,this stu... Only a small amount of spectral information is collected because the collection solid angle of the optical fiber probe and lens is very limited when collecting spectral information.To overcome this limitation,this study presents a novel method for acquiring plasma spectral information from various spatial directions.A parabolic-shaped plasma spectral collection device(PSCD)is employed to effectively collect more spectral information into the spectrometer,thereby enhancing the overall spectral intensity.The research objects in this study were soil samples containing different concentrations of heavy metals Pb,Cr,and Cd.The results indicate that the PSCD significantly enhances the spectral signal,with an enhancement rate of up to 45%.Moreover,the signal-to-noise ratio also increases by as much as 36%.Simultaneously,when compared to the absence of a device,it is found that there is no significant variation in plasma temperature when the PSCD is utilized.This observation eliminates the impact of the spatial effect caused by the PSCD on the spectral intensity.Consequently,a concentrationspectral intensity relationship curve is established under the PSCD.The results revealed that the linear fitting R^(2)for Pb,Cr,and Cd increased by 0.011,0.001,and 0.054,respectively.Additionally,the limit of detection(LOD)decreased by 0.361 ppm,0.901 ppm,and 0.602 ppm,respectively.These findings indicate that the spectral enhancement rate elevates with the increase in heavy metal concentration.Hence,the PSCD can effectively enhance the spectral intensity and reduce the detection limit of heavy metals in soil. 展开更多
关键词 LIBS plasma spectrum collection device spectral enhancement plasma temperature limit of detection
下载PDF
Spatiotemporal evolution laws of sector-shaped dielectric-barrier-discharge plasma actuator
13
作者 Borui ZHENG Jianbo ZHANG +4 位作者 Shaojie QI Jianghua XU Yiche LI Yuanzhong JIN Dongliang BIAN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第10期108-115,共8页
Dielectric barrier discharge(DBD)plasma actuators are widely used in active flow control due to their simple design and rapid responsiveness.However,they need more effectiveness and discharge extension.To overcome the... Dielectric barrier discharge(DBD)plasma actuators are widely used in active flow control due to their simple design and rapid responsiveness.However,they need more effectiveness and discharge extension.To overcome these limitations,a sector-shaped dielectric barrier discharge(SS-DBD)plasma actuator with an adjustable jet angle was developed to enhance flow control effectiveness.The flow field dynamics induced by the SS-DBD plasma actuator were quantitatively analyzed using particle image velocimetry(PIV).Experimental investigations showed that precise adjustments to the actuation voltage can modulate the maximum velocity of the induced jet.Furthermore,a quasi-linear relationship between the sector-shaped angles of the SS-DBD and the deflected jet angles was established,indicating that changes in the sector-shaped angles directly influence the direction of the deflected jet.This correlation enables precise control over jet angles,significantly enhancing flow control by adjusting the SS-DBD-PA's sector-shaped angle. 展开更多
关键词 plasma flow control plasma actuator particle image velocimetry
下载PDF
Wave field structure and power coupling features of blue-core helicon plasma driven by various antenna geometries and frequencies
14
作者 王超 刘佳 +3 位作者 苌磊 卢凌峰 张世杰 周帆涛 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期480-487,共8页
This paper deals with wave propagation and power coupling in blue-core helicon plasma driven by various antennas and frequencies.It is found that compared to non-blue-core mode,for blue-core mode,the wave can propagat... This paper deals with wave propagation and power coupling in blue-core helicon plasma driven by various antennas and frequencies.It is found that compared to non-blue-core mode,for blue-core mode,the wave can propagate in the core region,and it decays sharply outside the core.The power absorption is lower and steeper in radius for blue-core mode.Regarding the effects of antenna geometry for blue-core mode,it shows that half helix antenna yields the strongest wave field and power absorption,while loop antenna yields the lowest.Moreover,near axis,for antennas with m=+1,the wave field increases with axial distance.In the core region,the wave number approaches to a saturation value at much lower frequency for non-blue-core mode compared to blue-core mode.The total loading resistance is much lower for blue-core mode.These findings are valuable to understanding the physics of blue-core helicon discharge and optimizing the experimental performance of blue-core helicon plasma sources for applications such as space propulsion and material treatment. 展开更多
关键词 helicon plasma helicon wave helicon discharge radio frequency plasma source
下载PDF
Effect of coil and chamber structure on plasma radial uniformity in radio frequency inductively coupled plasma
15
作者 赵洋 周晓华 +2 位作者 高升荣 宋莎莎 赵玉真 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期58-66,共9页
Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial m... Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial manufacturing.This study utilized a two-dimensional self-consistent fluid model to investigate how different coil configurations and chamber aspect ratios affect the radial uniformity of plasma in radio frequency ICP.The findings indicate that optimizing the radial spacing of the coil enhances plasma uniformity but with a reduction in electron density.Furthermore,optimizing the coil within the ICP reactor,using the interior point method in the Interior Point Optimizer significantly enhances plasma uniformity,elevating it from 56%to 96%within the range of the model sizes.Additionally,when the chamber aspect ratio k changes from 2.8 to 4.7,the plasma distribution changes from a center-high to a saddleshaped distribution.Moreover,the plasma uniformity becomes worse.Finally,adjusting process parameters,such as increasing source power and gas pressure,can enhance plasma uniformity.These findings contribute to optimizing the etching process by improving plasma radial uniformity. 展开更多
关键词 inductively coupled plasma fluid simulation optimized coil chamber aspect ratio plasma uniformity
下载PDF
Plasma density enhancement in radio-frequency hollow electrode discharge
16
作者 贺柳良 何锋 欧阳吉庭 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期44-51,共8页
The plasma density enhancement outside hollow electrodes in capacitively coupled radio-frequency(RF) discharges is investigated by a two-dimensional(2D) particle-in-cell/Monte-Carlo collision(PIC/MCC) model. Results s... The plasma density enhancement outside hollow electrodes in capacitively coupled radio-frequency(RF) discharges is investigated by a two-dimensional(2D) particle-in-cell/Monte-Carlo collision(PIC/MCC) model. Results show that plasma exists inside the cavity when the sheath inside the hollow electrode hole is fully collapsed, which is an essential condition for the plasma density enhancement outside hollow electrodes. In addition, the existence of the electron density peak at the orifice is generated via the hollow cathode effect(HCE), which plays an important role in the density enhancement. It is also found that the radial width of bulk plasma at the orifice affects the magnitude of the density enhancement, and narrow radial plasma bulk width at the orifice is not beneficial to obtain high-density plasma outside hollow electrodes.Higher electron density at the orifice, combined with larger radial plasma bulk width at the orifice,causes higher electron density outside hollow electrodes. The results also imply that the HCE strength inside the cavity cannot be determined by the magnitude of the electron density outside hollow electrodes. 展开更多
关键词 RF capacitively coupled plasma sources plasma density enhancement hollow cathodeeffect hollow electrode
下载PDF
Non-thermal plasma enhanced catalytic conversion of methane into value added chemicals and fuels
17
作者 Shanza Baig Baharak Sajjadi 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第10期265-301,I0006,共38页
Plasma catalysis has recently gained increased attention for its application in gas conversion,notably in processes like the dry reforming of methane aimed at transforming them into valuable chemicals and fuels.As thi... Plasma catalysis has recently gained increased attention for its application in gas conversion,notably in processes like the dry reforming of methane aimed at transforming them into valuable chemicals and fuels.As this field is still in its early developmental stages,there is a crucial necessity to explore the synergistic mechanism between plasma and catalysts.The optimization of catalysts is imperative to improve their selectivity and conversion rates for desired products in a plasma environment.Additionally,delving into microscale investigations of plasma characteristics,such as electron temperature and the density of energetic species,is essential to enhance the stability and activity of catalysts.This review examines recent advancements in various methane conversion techniques,encompassing Dry Reforming of Methane,Steam Methane Reforming,Pa rtial Oxidation of Metha ne,and Methane Decomposition utilizing non-thermal dielectric barrier discharge(DBD)plasma.The aim is to gain a deeper understanding of plasma-catalyst interactions and to refine catalyst selection strategies for maximizing the production of desired products such as syngas,oxygenates,or higher hydrocarbons.The review delves into the catalytic mechanisms that delineate the synergistic effects between DBD plasma and catalyst in each technology,shedding light on the role of diverse catalytic properties in activating methane molecules-a pivotal step in hybrid plasma-catalytic reactions.Various approaches employed by researchers in exploring suitable catalysts and optimal reaction conditions to bolster CH_(4) conversion rates and selectivity using DBD plasma are discussed.Additionally,the review identifies gaps in the realm of plasma catalysis,underscoring the necessity for further research to fully understand the underlying principles of plasma and catalyst which are not trivial to uncover. 展开更多
关键词 Non-thermal plasma DBD CATALYST METHANE
下载PDF
Genetically Predicted Plasma Levels of Amino Acids and Endometriosis:A Mendelian Randomization Study
18
作者 Juanmei Li Yao Ni +4 位作者 Ning Wang Yu Liao Yiwei Yu Wenliang Lyu Ruihua Zhao 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2024年第6期672-675,共4页
Endometriosis(EMS)is one of the most common disorders among women of reproductive age and affects approximately 6%–10%of the world total population^([1]).Women with EMS often experience symptoms such as dysmenorrhea,... Endometriosis(EMS)is one of the most common disorders among women of reproductive age and affects approximately 6%–10%of the world total population^([1]).Women with EMS often experience symptoms such as dysmenorrhea,infertility,or difficulties in conceiving.Recent studies focusing on amino acids(AAs)metabolism have shed light on the mechanisms underlying the development and progression of EMS^([2]). 展开更多
关键词 METABOLISM INFERTILITY plasma
下载PDF
Plasma membrane-anchored fluorescent tracker based on boron-dipyrromethene
19
作者 Yucong Gong Xiangli Li +5 位作者 Daqing Ma Lai Wang Lin Zhou Caiwei Lu Yi Xiao Xinfu Zhang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第8期220-225,共6页
The construction of a stable-membrane tracker has significant implications for the visualization of the membrane in live cells.However,most current plasma trackers are not suitable for tracking plasma membranes for a ... The construction of a stable-membrane tracker has significant implications for the visualization of the membrane in live cells.However,most current plasma trackers are not suitable for tracking plasma membranes for a long time due to their limited retention time.Herein,Mem580-F-Sulfo is designed to target and anchor cell membranes and therefore track cell membranes for a longer time.This tracker is composed of a lipophilic boron-dipyrromethene(BODIPY)derivative and a hydrophilic zwitterion to form an amphiphilic structure,which enables its targeting ability toward cell membranes.Moreover,a reactive ester group is included to bind with proteins through covalent bonds in cell membranes nonspecifically,which extends retention time in cell membranes.Mem580-F-Sulfo shows intense brightness(94600),with a high molar absorption coefficient of up to about 100000 L·mol^(-1)·cm^(-1)and a fluorescence quantum yield of up to 0.97.It shows fast cell membrane targeting ability and long retention up to 90 min.In brief,this work has not only developed a tracker with good cell membrane targetability but also provided a new strategy for improving the targeting stability of cell membranes. 展开更多
关键词 plasma membrane PROTEIN TRACKER IMAGING MICROSTRUCTURE
下载PDF
Plasma Lysophosphatidylcholine and Phospholipase A2 Activity in Chagas Disease Patients: A Comparative Analysis
20
作者 Maria Fernanda Carvalho de Araujo Bruna Maria Ferreira Iaciura +1 位作者 Fillipe Araujo de Sá Georgia Correa Atella 《Advances in Bioscience and Biotechnology》 CAS 2024年第8期462-473,共12页
Chagas disease (CD) affects 21 countries in the Americas and is caused by the parasite Trypanosoma cruzi. A key molecule involved in CD is lysophosphatidylcholine (LPC), which has been studied in various contexts: in ... Chagas disease (CD) affects 21 countries in the Americas and is caused by the parasite Trypanosoma cruzi. A key molecule involved in CD is lysophosphatidylcholine (LPC), which has been studied in various contexts: in the saliva of insect vectors, during the establishment of infection in the vertebrate host, and for the parasite itself. This lipid can be produced by the action of phospholipases A2 (PLA2), enzymes that catalyze the hydrolysis of phospholipids releasing fatty acids and lysophospholipids, such as LPC. This study investigates LPC levels and PLA2 activities in the plasma of CD patients and compares these levels with those in healthy individuals and patients with idiopathic dilated cardiomyopathy (IDCM). Plasma from 64 CD patients, 54 healthy individuals, and 16 IDCM patients were analyzed. LPC levels and the activity of two types of phospholipase A2: secreted (sPLA2) and lipoprotein-associated (Lp-PLA2) were measured. LPC levels and sPLA2 activity were similar between CD patients and the control groups. However, there were notable differences in LPC levels and sPLA2 activity between subgroups of CD patients and IDCM patients. This study is the first to identify LPC in patients with CD across various stages of the disease. It also offers new insights into the biochemical changes observed in the plasma of patients with IDCM. 展开更多
关键词 LYSOPHOSPHATIDYLCHOLINE Phospholipase A2 plasma Chagas Disease Idiopathic Dilated Cardiomyopathy
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部