Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for ...Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for laser plasma diagnostics was achieved using a developed toroidal crystal x-ray imager.A high-index crystal orientation Ge(531)wafer with a Bragg angle of 75.37°and the toroidal substrate were selected to obtain sufficient diffraction efficiency and compensate for astigmatism under oblique incidence.A precise offline assembly method of the toroidal crystal imager based on energy substitution was proposed,and a spatial resolution of 3-7μm was obtained by toroidal crystal imaging of a 600 line-pairs/inch Au grid within an object field of view larger than 1.0 mm.The toroidal crystal x-ray imager has been successfully tested via side-on backlight imaging experiments of the sinusoidal modulation target and a 1000 line-pairs/inch Au grid with a linewidth of 5μm using an online alignment method based on dual positioning balls to indicate the target and backlighter.This paper describes the optical design,adjustment method,and experimental results of a toroidal crystal system in a laboratory and laser facility.展开更多
The measuring principle and experimental results of the enthalpy probe technique for thermal plasma diagnostics are presented. Its calibration and errors are discussed. Typical results are presented for the system ope...The measuring principle and experimental results of the enthalpy probe technique for thermal plasma diagnostics are presented. Its calibration and errors are discussed. Typical results are presented for the system operation in an Ar/H2(5 % H2) plasma arc jet under a reactor chamber pressure of 101.3 kPa. The plasma temperature and velocity profiles are measured. The center temperature and velocity are 6600 K and 850 m/s for plasma power 9 kW at axial location of 17 mm.展开更多
Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physi...Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physics information) while avoiding unnecessary generation of a large volume data. SST-1 Phase-1 tokamak operation has been envisaged with data acquisition of several essential diagnostics channels. These channels demand data acquisition at a sampling rate ranging from 1 kilo samples per second (KSPS) to 1 mega samples per second (MSPS). Considering the technical characteristics and requirements of the diagnostics, a data acquisition system based on PXI and CAMAC has been developed for SST-1 plasma diagnostics. Both these data acquisition systems are scalable. Present data acquisition needs involving slow plasma diagnostics are catered by the PXI based data acquisition system. On the other hand, CAMAC data acquisition hardware meets all requirements of the SST-1 Phase-1 fast plasma diagnostics channels. A graphical user interface for both data acquisition systems (PXI and CAMAC) has been developed using LabVIEW application development software. The collected data on the local hard disk are directly streaming to the central server through a dedicated network for post-shot data analysis. This paper describes the development and integration of the data acquisition system for SST-1 Phase-1 plasma diagnostics. The integrated testing of the developed data acquisition system has been performed using SST-1 central control and diagnostics signal conditioning units. In the absence of plasma shots, the integrated testing of the data acquisition system for the initial diagnostics of SST-1 Phase-1 operation has been performed with simulated physical signals. The primary engineering objective of this integrated testing is to validate the performance of the developed data acquisition system under simulated conditions close to that of actual tokamak operation. The data acquisition is synchronized with a clock and trigger provided by the central timing system.展开更多
In order to achieve a better understanding of plume characteristics of LIPS-300 ion thruster,the beam current density,ion energy and electron number density of LIPS-300 ion thruster plume are studied with an Advanced ...In order to achieve a better understanding of plume characteristics of LIPS-300 ion thruster,the beam current density,ion energy and electron number density of LIPS-300 ion thruster plume are studied with an Advanced Plasma Diagnostics System(APDS)which allows for simultaneous in situ measurements of various properties characterizing ion thruster,such as plasma density,plasma potential,plasma temperature and ion beam current densities,ion energy distribution and so on.The results show that the beam current density distribution has a double‘wing'shape.The high energy ions were found in small scan angle,while low energy ions were found in greater scan angle.Electron number density has a similar shape with the beam current density distribution.展开更多
The development of eight new diagnostic systems and the improvement of the laser Thomson scattering system contributed to the experimental campaign on HL-2A in 2006. Besides, the accuracy and flexibility of the molecu...The development of eight new diagnostic systems and the improvement of the laser Thomson scattering system contributed to the experimental campaign on HL-2A in 2006. Besides, the accuracy and flexibility of the molecular beam injection (MBI) system was improved greatly by using the special driver and controller, it is more convenient for studies such as particle transport. In the field of plasma physics experiment, the features of 3-D GAM zonal flows were further studied and some signs of low frequency zonal flows were observed. In the ECRH experiments, the effects of ECRH on sawtooth activities and m/n= 1/1 mode were studied under different plasma discharge conditions. The effect of MBI during ECRH on plasma behavior, such as non-local heat transport, was also studied.展开更多
In this study,we report a laser interferometry experiment for the online-diagnosing of a laserproduced plasma.The laser pulses generating the plasma are ultra-fast(30 femtoseconds),ultraintense(tens of Terawatt) a...In this study,we report a laser interferometry experiment for the online-diagnosing of a laserproduced plasma.The laser pulses generating the plasma are ultra-fast(30 femtoseconds),ultraintense(tens of Terawatt) and are focused on a helium gas jet to generate relativistic electron beams via the laser wakefield acceleration(LWFA) mechanism.A probe laser beam(λ=800 nm) which is split-off the main beam is used to cross the plasma at the time of arrival of the main pulse,allowing online plasma density diagnostics.The interferometer setup is based on the No Marski method in which we used a Fresnel bi-prism where the probe beam interferes with itself after crossing the plasma medium.A high-dynamic range CCD camera is used to record the interference patterns.Based upon the Abel inversion technique,we obtained a 3D density distribution of the plasma density.展开更多
Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based...Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based polymer that is,among other things,interesting as a substrate for laser-induced breakdown spectroscopy analysis of liquid samples.This study aimed to determine the optimal experimental conditions for obtaining neutral and ionized C spectral lines and C2 and CN molecular band emission suitable for spectrochemical purposes.Evaluation of plasma parameters was done using several spectroscopic techniques.Stark profiles of appropriate C ionic lines were used to determine electron number density.The ratio of the integral intensity of ionic-to-atomic C spectral lines was used to determine the ionization temperature.A spectral emission of C2 Swan and CN violet bands system was used to determine the temperature of the colder,peripheral parts of plasma.We critically analyzed the use of molecular emission bands as a tool for plasma diagnostics and suggested methods for possible improvements.展开更多
An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation devi...An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation device and gated MCP imager,and a spatial resolution of 100μm by using an electronic imaging system comprising combined magnetic lenses.The spatial resolution characteristics of the camera were studied both theoretically and experimentally.The results showed that the camera with combined magnetic lenses reduced the field curvature and acquired a larger working area.A working area with a diameter of 53 mm was created by applying four magnetic lenses to the camera.Furthermore,the camera was used to detect the X-rays produced by the laser-targeting device.The diagnostic results indicated that the width of the X-ray pulse was approximately 18 ps.展开更多
A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-s...A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-state sources(-650 GHz)is applied for simultaneous measurements of electron density and Faraday rotation angle.The output power of the microwave source is 2 mW.Faraday rotation effect using a rotating wave plate is tested with phase noise less than 0.8°,and the density phase noise is less than 0.9°.Measurement of Faraday rotation angle and density for discharges on KTX have demonstrated high sensitivity to internal MHD activities.展开更多
The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of tr...The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).展开更多
A new high spectral resolution crystal spectrometer is designed to measure very low emissive X-ray spectra of laser-produced plasma in 0.5-0.9 nm range. A large open aperture (30 ×20 (mm)) mica (002) spheri...A new high spectral resolution crystal spectrometer is designed to measure very low emissive X-ray spectra of laser-produced plasma in 0.5-0.9 nm range. A large open aperture (30 ×20 (mm)) mica (002) spherically bent crystal with curvature radius R = 380 mm is used as dispersive and focusing element. The imaging plate is employed to obtain high spectral resolution with effective area of 30 × 80 (mm). The long designed path of the X-ray spectrometer beam is 980 mm from the source to the detector via the crystal. Experiment is carried out at a 20-J laser facility. X-ray spectra in an absolute intensity scale is obtained from Al laserproduced plasmas created by laser energy of 6.78 J. Samples of spectra obtained with spectral resolution of up to E/△E - 1500 are presented. The results clearly show that the device is good to diagnose laser high-density plasmas.展开更多
A four-channel multilayer Kirkpatrick-Baez (KB) microscope is developed for the 8-keV X-ray imaging of experiments on laser inertial confinement fusion (ICF). A periodic multilayer that works at 8 keV and with a g...A four-channel multilayer Kirkpatrick-Baez (KB) microscope is developed for the 8-keV X-ray imaging of experiments on laser inertial confinement fusion (ICF). A periodic multilayer that works at 8 keV and with a grazing incidence angle of 1.0~ is coated on reflective surfaces to achieve a spatial resolution higher than 5μm and an effective solid angle higher than 10-7 sr. A precise assembly is realized by a conical reference cone to couple with an X-ray framing camera. This study provides detailed information on an optical and multilayer design, assembly method, and experimental results with a Cu X-ray tube. The instrument provides a high-resolution and high-throughput X-ray image for backlit or self-emission imaging of laser plasma at Cu Kα line radiation in Shenguang series laser facilities.展开更多
A time-resolved multispectral X-ray imaging approach with new version of multi-channel Kirkpatrick- Baez (KB) microscope is developed for laser plasma diagnostics at the kilo joule-class Shenguang-II laser facility ...A time-resolved multispectral X-ray imaging approach with new version of multi-channel Kirkpatrick- Baez (KB) microscope is developed for laser plasma diagnostics at the kilo joule-class Shenguang-II laser facility (SG-II). The microscope uses a total external reflection mirror in the sagittal direction and an array of multilayer mirrors in the tangential direction to obtain multiple individual high-resolution, high- throughput, and quasi-monochromatic X-ray images. The time evolution of the imploded target in multiple X-ray energy bands can be acquired when coupled with an X-ray streak camera. The experimental result of the time-resolved 2.5 and 3.0 keV dual-spectral self-emission imaging of the undoped CH shell target on SG-II is given.展开更多
The capacitively coupled radio frequency(CCRF)plasma has been widely used in various fields.In some cases,it requires us to estimate the range of key plasma parameters simpler and quicker in order to understand the ...The capacitively coupled radio frequency(CCRF)plasma has been widely used in various fields.In some cases,it requires us to estimate the range of key plasma parameters simpler and quicker in order to understand the behavior in plasma.In this paper,a glass vacuum chamber and a pair of plate electrodes were designed and fabricated,using 13.56 MHz radio frequency(RF)discharge technology to ionize the working gas of Ar.This discharge was mathematically described with equivalent circuit model.The discharge voltage and current of the plasma were measured atdifferent pressures and different powers.Based on the capacitively coupled homogeneous discharge model,the equivalent circuit and the analytical formula were established.The plasma density and temperature were calculated by using the equivalent impedance principle and energy balance equation.The experimental results show that when RF discharge power is 50–300 W and pressure is 25–250 Pa,the average electron temperature is about 1.7–2.1 e V and the average electron density is about 0.5?×10^17–3.6?×10^17m^-3.Agreement was found when the results were compared to those given by optical emission spectroscopy and COMSOL simulation.展开更多
Computational simulation of the radiating structure of a microwave from a pyramidal horn has been successfully accomplished.This simulation capability is de-veloped for plasma diagnostics based on a combination of thr...Computational simulation of the radiating structure of a microwave from a pyramidal horn has been successfully accomplished.This simulation capability is de-veloped for plasma diagnostics based on a combination of three-dimensional Maxwell equations in the time domain and the generalized Ohm’s law.The transverse electrical electromagnetic wave of the TE1,0 mode propagating through a plasma medium and transmitting from antenna is simulated by solving these governing equations.Numerical results were obtained for a range of plasma transport properties including electrical con-ductivity,permittivity,and plasma frequency.As a guided microwave passing through plasma of finite thickness,the reflections at the media interfaces exhibit substantial distortion of the electromagnetic field within the thin sheet.In radiating simulation,the edge diffraction at the antenna aperture is consistently captured by numerical so-lutions and reveals significant perturbation to the emitting microwave.The numerical solution reaffirms the observation that the depth of the plasma is a critical parameter for diagnostics measurement.展开更多
An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES fro...An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES from argon ICP and DBD plasmas in visible and near ultraviolet region were measured. For argon ICP, the higher RF power input (higher than 500 W for our machine), the higher degree of argon plasma ionization. But that doesn't mean a higher mean electron energy. With the increase in the power input, the mean electron energy increases slightly, whereas the density of electron increases apparently On the contrary, argon DBD discharge behaves in the manner of a pulsed DC discharge on optical emission spectroscopy and V-I characteristics. DBD current is composed of a series of pulses equally spaced in temporal domain. The Kinetics of DBD emission strength is mainly governed by the frequency of the current pulse.展开更多
Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for c...Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for characterizing electron dynamics and applications.In this study,scintillators and silicon PIN(P-type–intrinsic-N-type semiconductor)diodes were used to construct a wideband online filter stack spectrometer.The X-ray sensor and filter arrangement was optimized using a genetic algorithm to minimize the condition number of the response matrix.Consequently,the unfolding error was significantly reduced based on numerical experiments.The detector responses were quantitatively calibrated by irradiating the scintillator and PIN diode with various nuclides and comparing the measuredγ-ray peaks.A prototype 15-channel spectrometer was developed by integrating an X-ray detector with front-and back-end electronics.The prototype spectrometer could record X-ray pulse signals at a repetition rate of 1 kHz.Furthermore,an optimized spectrometer was employed to record the real-time spectra of laser-driven bremsstrahlung sources.This optimized spectrometer offers a compact solution for spectrum diagnostics of ultrashort X-ray pulses,exhibiting improved accuracy in terms of spectrum measurements and repetition rates,and could be widely used in next-generation high-repetition-rate high-power laser facilities.展开更多
A dispersion interferometer(DI)has been installed and operates on the Experimental Advanced Superconducting Tokamak(EAST).This DI system utilizes a continuous-wave 9.3μm CO_(2)laser source to measure line-averaged el...A dispersion interferometer(DI)has been installed and operates on the Experimental Advanced Superconducting Tokamak(EAST).This DI system utilizes a continuous-wave 9.3μm CO_(2)laser source to measure line-averaged electron densities accurately.In contrast to conventional interferometers,the DI does not require substantial vibration isolations or compensating systems to reduce the impact of vibrations in the optical path.It also employs a ratio of modulation amplitudes,ensuring it remains immune to the variations in detected intensities.Without a variation compensation system,the DI system on EAST reaches a density resolution of less than1.8×10^(-2)πrad and a temporal resolution of 20μs.The measurements made by the POlarimeterINTerferometer(POINT)system and the far-infrared hydrogen cyanide(HCN)interferometer are remarkably consistent with the DI’s results.The possibility of fringe jumps and the impact of refraction in high-density discharge can be significantly decreased using a shorter wavelength laser source.A rapid density change of 3×10^(19)m^(-3)during 0.15 s has been measured accurately in shot No.114755 of EAST.Additionally,the DI system demonstrates dependability and stability under 305 s long-pulse discharges in shot No.122054.展开更多
The plasma diagnostic method using the transmission attenuation of microwaves at double frequencies (PDMUTAMDF) indicates that the frequency and the electron-neutral collision frequency of the plasma can be deduced ...The plasma diagnostic method using the transmission attenuation of microwaves at double frequencies (PDMUTAMDF) indicates that the frequency and the electron-neutral collision frequency of the plasma can be deduced by utilizing the transmission attenuation of microwaves at two neighboring frequencies in a non-magnetized plasma. Then the electron density can be obtained from the plasma frequency. The PDMUTAMDF is a simple method to diagnose the plasma indirectly. In this paper, the interaction of electromagnetic waves and the plasma is analyzed. Then, based on the attenuation and the phase shift of a microwave in the plasma, the principle of the PDMUTAMDF is presented. With the diagnostic method, the spatially mean electron density and electron collision frequency of the plasma can be obtained. This method is suitable for the elementary diagnosis of the atmospheric-pressure plasma.展开更多
In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas o...In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas of dc glow discharges at low pressures in laboratory by measuring the relative intensities of ArI lines at various pressures. These methods are developed respectively on the basis of the Fermi-Dirac model, corona model, and two kinds of electron collision cross section models according to the kinetic analysis. Their theoretical bases and the conditions to which they are applicable are reviewed, and their calculation results and fitting errors are compared with each other. The investigation has indicated that the electron temperatures obtained by the four methods become consistent with each other when the pressure increases in the low pressure argon plasmas.展开更多
基金National Natural Science Foundation of China(No.11805212)National Key Research and Development Program of China(No.2019YFE03080200)。
文摘Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for laser plasma diagnostics was achieved using a developed toroidal crystal x-ray imager.A high-index crystal orientation Ge(531)wafer with a Bragg angle of 75.37°and the toroidal substrate were selected to obtain sufficient diffraction efficiency and compensate for astigmatism under oblique incidence.A precise offline assembly method of the toroidal crystal imager based on energy substitution was proposed,and a spatial resolution of 3-7μm was obtained by toroidal crystal imaging of a 600 line-pairs/inch Au grid within an object field of view larger than 1.0 mm.The toroidal crystal x-ray imager has been successfully tested via side-on backlight imaging experiments of the sinusoidal modulation target and a 1000 line-pairs/inch Au grid with a linewidth of 5μm using an online alignment method based on dual positioning balls to indicate the target and backlighter.This paper describes the optical design,adjustment method,and experimental results of a toroidal crystal system in a laboratory and laser facility.
文摘The measuring principle and experimental results of the enthalpy probe technique for thermal plasma diagnostics are presented. Its calibration and errors are discussed. Typical results are presented for the system operation in an Ar/H2(5 % H2) plasma arc jet under a reactor chamber pressure of 101.3 kPa. The plasma temperature and velocity profiles are measured. The center temperature and velocity are 6600 K and 850 m/s for plasma power 9 kW at axial location of 17 mm.
文摘Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physics information) while avoiding unnecessary generation of a large volume data. SST-1 Phase-1 tokamak operation has been envisaged with data acquisition of several essential diagnostics channels. These channels demand data acquisition at a sampling rate ranging from 1 kilo samples per second (KSPS) to 1 mega samples per second (MSPS). Considering the technical characteristics and requirements of the diagnostics, a data acquisition system based on PXI and CAMAC has been developed for SST-1 plasma diagnostics. Both these data acquisition systems are scalable. Present data acquisition needs involving slow plasma diagnostics are catered by the PXI based data acquisition system. On the other hand, CAMAC data acquisition hardware meets all requirements of the SST-1 Phase-1 fast plasma diagnostics channels. A graphical user interface for both data acquisition systems (PXI and CAMAC) has been developed using LabVIEW application development software. The collected data on the local hard disk are directly streaming to the central server through a dedicated network for post-shot data analysis. This paper describes the development and integration of the data acquisition system for SST-1 Phase-1 plasma diagnostics. The integrated testing of the developed data acquisition system has been performed using SST-1 central control and diagnostics signal conditioning units. In the absence of plasma shots, the integrated testing of the data acquisition system for the initial diagnostics of SST-1 Phase-1 operation has been performed with simulated physical signals. The primary engineering objective of this integrated testing is to validate the performance of the developed data acquisition system under simulated conditions close to that of actual tokamak operation. The data acquisition is synchronized with a clock and trigger provided by the central timing system.
文摘In order to achieve a better understanding of plume characteristics of LIPS-300 ion thruster,the beam current density,ion energy and electron number density of LIPS-300 ion thruster plume are studied with an Advanced Plasma Diagnostics System(APDS)which allows for simultaneous in situ measurements of various properties characterizing ion thruster,such as plasma density,plasma potential,plasma temperature and ion beam current densities,ion energy distribution and so on.The results show that the beam current density distribution has a double‘wing'shape.The high energy ions were found in small scan angle,while low energy ions were found in greater scan angle.Electron number density has a similar shape with the beam current density distribution.
文摘The development of eight new diagnostic systems and the improvement of the laser Thomson scattering system contributed to the experimental campaign on HL-2A in 2006. Besides, the accuracy and flexibility of the molecular beam injection (MBI) system was improved greatly by using the special driver and controller, it is more convenient for studies such as particle transport. In the field of plasma physics experiment, the features of 3-D GAM zonal flows were further studied and some signs of low frequency zonal flows were observed. In the ECRH experiments, the effects of ECRH on sawtooth activities and m/n= 1/1 mode were studied under different plasma discharge conditions. The effect of MBI during ECRH on plasma behavior, such as non-local heat transport, was also studied.
文摘In this study,we report a laser interferometry experiment for the online-diagnosing of a laserproduced plasma.The laser pulses generating the plasma are ultra-fast(30 femtoseconds),ultraintense(tens of Terawatt) and are focused on a helium gas jet to generate relativistic electron beams via the laser wakefield acceleration(LWFA) mechanism.A probe laser beam(λ=800 nm) which is split-off the main beam is used to cross the plasma at the time of arrival of the main pulse,allowing online plasma density diagnostics.The interferometer setup is based on the No Marski method in which we used a Fresnel bi-prism where the probe beam interferes with itself after crossing the plasma medium.A high-dynamic range CCD camera is used to record the interference patterns.Based upon the Abel inversion technique,we obtained a 3D density distribution of the plasma density.
基金funded by the Ministry of Education,Science and Technological Development of the Republic of Serbia(Nos.451-03-68/2022-14/200017 and 451-03-68/2022-14/200146)the financial support of the State Committee on Science and Technology of the Republic of Belarusthe Belarusian Republican Foundation for Fundamental Research(No.F20SRBG-001)。
文摘Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based polymer that is,among other things,interesting as a substrate for laser-induced breakdown spectroscopy analysis of liquid samples.This study aimed to determine the optimal experimental conditions for obtaining neutral and ionized C spectral lines and C2 and CN molecular band emission suitable for spectrochemical purposes.Evaluation of plasma parameters was done using several spectroscopic techniques.Stark profiles of appropriate C ionic lines were used to determine electron number density.The ratio of the integral intensity of ionic-to-atomic C spectral lines was used to determine the ionization temperature.A spectral emission of C2 Swan and CN violet bands system was used to determine the temperature of the colder,peripheral parts of plasma.We critically analyzed the use of molecular emission bands as a tool for plasma diagnostics and suggested methods for possible improvements.
基金National Natural Science Foundation of China(NSFC)(No.11775147)Guangdong Basic and Applied Basic Research Foundation(Nos.2019A1515110130 and 2024A1515011832)+1 种基金Shenzhen Key Laboratory of Photonics and Biophotonics(ZDSYS20210623092006020)Shenzhen Science and Technology Program(Nos.JCYJ20210324095007020,JCYJ20200109105201936 and JCYJ20230808105019039).
文摘An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation device and gated MCP imager,and a spatial resolution of 100μm by using an electronic imaging system comprising combined magnetic lenses.The spatial resolution characteristics of the camera were studied both theoretically and experimentally.The results showed that the camera with combined magnetic lenses reduced the field curvature and acquired a larger working area.A working area with a diameter of 53 mm was created by applying four magnetic lenses to the camera.Furthermore,the camera was used to detect the X-rays produced by the laser-targeting device.The diagnostic results indicated that the width of the X-ray pulse was approximately 18 ps.
基金supported by National Natural Science Foundation of China(No.12175227)the Fundamental Research Funds for the Central Universities(No.USTC 20210079)the Collaborative Innovation Program of Hefei Science Center,CAS(No.2022HSC-CIP022)。
文摘A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-state sources(-650 GHz)is applied for simultaneous measurements of electron density and Faraday rotation angle.The output power of the microwave source is 2 mW.Faraday rotation effect using a rotating wave plate is tested with phase noise less than 0.8°,and the density phase noise is less than 0.9°.Measurement of Faraday rotation angle and density for discharges on KTX have demonstrated high sensitivity to internal MHD activities.
基金supported by the National Key Research and Development Program of China(Nos.2019YFE03090100 and 2022YFE03100002)National Natural Science Foundation of China(No.12075241)。
文摘The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).
基金supported by the National Natural Science Foundation of China under Grant No.10576041
文摘A new high spectral resolution crystal spectrometer is designed to measure very low emissive X-ray spectra of laser-produced plasma in 0.5-0.9 nm range. A large open aperture (30 ×20 (mm)) mica (002) spherically bent crystal with curvature radius R = 380 mm is used as dispersive and focusing element. The imaging plate is employed to obtain high spectral resolution with effective area of 30 × 80 (mm). The long designed path of the X-ray spectrometer beam is 980 mm from the source to the detector via the crystal. Experiment is carried out at a 20-J laser facility. X-ray spectra in an absolute intensity scale is obtained from Al laserproduced plasmas created by laser energy of 6.78 J. Samples of spectra obtained with spectral resolution of up to E/△E - 1500 are presented. The results clearly show that the device is good to diagnose laser high-density plasmas.
基金supported by the National"973"Program of China(No.2011CB922203)the National Natural Science Foundation of China(Nos.11105098,11027507,and 11305116)the Scientific Research Plan Projects of the Science and Technology Commission of Shanghai(No.11nm0507200)
文摘A four-channel multilayer Kirkpatrick-Baez (KB) microscope is developed for the 8-keV X-ray imaging of experiments on laser inertial confinement fusion (ICF). A periodic multilayer that works at 8 keV and with a grazing incidence angle of 1.0~ is coated on reflective surfaces to achieve a spatial resolution higher than 5μm and an effective solid angle higher than 10-7 sr. A precise assembly is realized by a conical reference cone to couple with an X-ray framing camera. This study provides detailed information on an optical and multilayer design, assembly method, and experimental results with a Cu X-ray tube. The instrument provides a high-resolution and high-throughput X-ray image for backlit or self-emission imaging of laser plasma at Cu Kα line radiation in Shenguang series laser facilities.
基金the National Natural Science Foundation of China(Nos.11305116 and 11105098)the National Key Technology Support Program(No.2013BAK14B02)the National"973"Program ofChina(No.2011CB922203)
文摘A time-resolved multispectral X-ray imaging approach with new version of multi-channel Kirkpatrick- Baez (KB) microscope is developed for laser plasma diagnostics at the kilo joule-class Shenguang-II laser facility (SG-II). The microscope uses a total external reflection mirror in the sagittal direction and an array of multilayer mirrors in the tangential direction to obtain multiple individual high-resolution, high- throughput, and quasi-monochromatic X-ray images. The time evolution of the imploded target in multiple X-ray energy bands can be acquired when coupled with an X-ray streak camera. The experimental result of the time-resolved 2.5 and 3.0 keV dual-spectral self-emission imaging of the undoped CH shell target on SG-II is given.
基金supported by National Natural Science Foundation of China(Grant No.61378037)the Fundamental Research Funds for the Central Universities(Nos.2013B33614,2017B15214)+1 种基金the Research Funds of Innovation and Entrepreneurship Education Reform for Chinese Universities(No.16CCJG01Z004)the Changzhou Science and Technology Program(No.CJ20160027)
文摘The capacitively coupled radio frequency(CCRF)plasma has been widely used in various fields.In some cases,it requires us to estimate the range of key plasma parameters simpler and quicker in order to understand the behavior in plasma.In this paper,a glass vacuum chamber and a pair of plate electrodes were designed and fabricated,using 13.56 MHz radio frequency(RF)discharge technology to ionize the working gas of Ar.This discharge was mathematically described with equivalent circuit model.The discharge voltage and current of the plasma were measured atdifferent pressures and different powers.Based on the capacitively coupled homogeneous discharge model,the equivalent circuit and the analytical formula were established.The plasma density and temperature were calculated by using the equivalent impedance principle and energy balance equation.The experimental results show that when RF discharge power is 50–300 W and pressure is 25–250 Pa,the average electron temperature is about 1.7–2.1 e V and the average electron density is about 0.5?×10^17–3.6?×10^17m^-3.Agreement was found when the results were compared to those given by optical emission spectroscopy and COMSOL simulation.
文摘Computational simulation of the radiating structure of a microwave from a pyramidal horn has been successfully accomplished.This simulation capability is de-veloped for plasma diagnostics based on a combination of three-dimensional Maxwell equations in the time domain and the generalized Ohm’s law.The transverse electrical electromagnetic wave of the TE1,0 mode propagating through a plasma medium and transmitting from antenna is simulated by solving these governing equations.Numerical results were obtained for a range of plasma transport properties including electrical con-ductivity,permittivity,and plasma frequency.As a guided microwave passing through plasma of finite thickness,the reflections at the media interfaces exhibit substantial distortion of the electromagnetic field within the thin sheet.In radiating simulation,the edge diffraction at the antenna aperture is consistently captured by numerical so-lutions and reveals significant perturbation to the emitting microwave.The numerical solution reaffirms the observation that the depth of the plasma is a critical parameter for diagnostics measurement.
基金This work is supported by the National Science Foundation of China No.19835030.
文摘An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES from argon ICP and DBD plasmas in visible and near ultraviolet region were measured. For argon ICP, the higher RF power input (higher than 500 W for our machine), the higher degree of argon plasma ionization. But that doesn't mean a higher mean electron energy. With the increase in the power input, the mean electron energy increases slightly, whereas the density of electron increases apparently On the contrary, argon DBD discharge behaves in the manner of a pulsed DC discharge on optical emission spectroscopy and V-I characteristics. DBD current is composed of a series of pulses equally spaced in temporal domain. The Kinetics of DBD emission strength is mainly governed by the frequency of the current pulse.
基金partially supported by the Natural Science Foundation of China(Nos.12004353,11975214,11991071,11905202,12175212,and 12120101005)the Key Laboratory Foundation of the Science and Technology on Plasma Physics Laboratory(Nos.6142A04200103 and 6142A0421010).
文摘Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for characterizing electron dynamics and applications.In this study,scintillators and silicon PIN(P-type–intrinsic-N-type semiconductor)diodes were used to construct a wideband online filter stack spectrometer.The X-ray sensor and filter arrangement was optimized using a genetic algorithm to minimize the condition number of the response matrix.Consequently,the unfolding error was significantly reduced based on numerical experiments.The detector responses were quantitatively calibrated by irradiating the scintillator and PIN diode with various nuclides and comparing the measuredγ-ray peaks.A prototype 15-channel spectrometer was developed by integrating an X-ray detector with front-and back-end electronics.The prototype spectrometer could record X-ray pulse signals at a repetition rate of 1 kHz.Furthermore,an optimized spectrometer was employed to record the real-time spectra of laser-driven bremsstrahlung sources.This optimized spectrometer offers a compact solution for spectrum diagnostics of ultrashort X-ray pulses,exhibiting improved accuracy in terms of spectrum measurements and repetition rates,and could be widely used in next-generation high-repetition-rate high-power laser facilities.
基金supported by the Comprehensive Research Facility for Fusion Technology Program of China(No.2018-000052-7301-001228)the Major Special Science and Technology Project of Anhui Province(No.912188707023)。
文摘A dispersion interferometer(DI)has been installed and operates on the Experimental Advanced Superconducting Tokamak(EAST).This DI system utilizes a continuous-wave 9.3μm CO_(2)laser source to measure line-averaged electron densities accurately.In contrast to conventional interferometers,the DI does not require substantial vibration isolations or compensating systems to reduce the impact of vibrations in the optical path.It also employs a ratio of modulation amplitudes,ensuring it remains immune to the variations in detected intensities.Without a variation compensation system,the DI system on EAST reaches a density resolution of less than1.8×10^(-2)πrad and a temporal resolution of 20μs.The measurements made by the POlarimeterINTerferometer(POINT)system and the far-infrared hydrogen cyanide(HCN)interferometer are remarkably consistent with the DI’s results.The possibility of fringe jumps and the impact of refraction in high-density discharge can be significantly decreased using a shorter wavelength laser source.A rapid density change of 3×10^(19)m^(-3)during 0.15 s has been measured accurately in shot No.114755 of EAST.Additionally,the DI system demonstrates dependability and stability under 305 s long-pulse discharges in shot No.122054.
文摘The plasma diagnostic method using the transmission attenuation of microwaves at double frequencies (PDMUTAMDF) indicates that the frequency and the electron-neutral collision frequency of the plasma can be deduced by utilizing the transmission attenuation of microwaves at two neighboring frequencies in a non-magnetized plasma. Then the electron density can be obtained from the plasma frequency. The PDMUTAMDF is a simple method to diagnose the plasma indirectly. In this paper, the interaction of electromagnetic waves and the plasma is analyzed. Then, based on the attenuation and the phase shift of a microwave in the plasma, the principle of the PDMUTAMDF is presented. With the diagnostic method, the spatially mean electron density and electron collision frequency of the plasma can be obtained. This method is suitable for the elementary diagnosis of the atmospheric-pressure plasma.
文摘In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas of dc glow discharges at low pressures in laboratory by measuring the relative intensities of ArI lines at various pressures. These methods are developed respectively on the basis of the Fermi-Dirac model, corona model, and two kinds of electron collision cross section models according to the kinetic analysis. Their theoretical bases and the conditions to which they are applicable are reviewed, and their calculation results and fitting errors are compared with each other. The investigation has indicated that the electron temperatures obtained by the four methods become consistent with each other when the pressure increases in the low pressure argon plasmas.