期刊文献+
共找到11篇文章
< 1 >
每页显示 20 50 100
Small splints versus plate fixation for distal radius fractures: A meta- analysis and systematical analysis
1
作者 Xin Cui Long Liang +3 位作者 Yong-Yao Li Ya-Chao Du Ya-Liang Tian Yang Chen 《Journal of Hainan Medical University》 2021年第21期53-59,共7页
Objective:Evaluate the efficacy,safety and economy of small splints and plate in the treatment of distal radius fractures(DRFs).Methods:Seven electronic databases,including PubMed,EMBASE,Cochrane Library,sinomed,CNKI,... Objective:Evaluate the efficacy,safety and economy of small splints and plate in the treatment of distal radius fractures(DRFs).Methods:Seven electronic databases,including PubMed,EMBASE,Cochrane Library,sinomed,CNKI,VIP and Wanfang,were searched for the original study.Literature was screened according to the inclusion and exclusion criteria,and the methodological quality of the included studies was evaluated by Cochrane risk bias assessment tool.The software Revman 5.4 was used for data analysis.Results:A total of 19 studies were included in the study.The clinical effective rate of the plate group[RR=0.96,95%CI(0.93,0.99),P=0.007],Radial inclination[MD=-1.85,95%CI(-2.93,-0.77),P=0.0008],Ulnar inclination[MD=-2.49,95%CI(-3.95,-1.04),P=0.0007],relative height of radius[MD=-1.63,95%CI(-2.40,-0.86),P<0.0001]were better than those in small splints group.There was no significant difference in fracture healing time[MD=-4.39,95%CI(-9.07,0.28),P=0.07]and complications[RR=1.57,95%CI(0.98,2.52),P=0.06]between the two groups.In terms of treatment cost[MD=-2.83,95%CI(-3.37,-2.30),P<0.00001],the small splint group was better than the plate treatment group.Conclusion:Compared with small splints therapy,plate internal fixation has advantages in clinical effective rate and imaging scores.There is no significant difference in fracture healing time and complications between the two groups.In terms of treatment cost,small splint therapy is better than plate therapy.Clinical treatment should be selected and formulated according to the individual situation,demands and clinical practice of patients. 展开更多
关键词 Small splints plate fixation Distal radius fractures Systematic review META-ANALYSIS
下载PDF
A Biomechanical Comparison of Conventional versus an Anatomic Plate and Compression Bolts for Fixation of Intra-articular Calcaneal Fractures 被引量:6
2
作者 王海立 杨朝旭 +5 位作者 吴战坡 陈伟 张奇 李明 李智勇 张英泽 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2012年第4期571-575,共5页
The purpose of this study was to compare the biomechanical stability obtained by using our technique featured an anatomical plate and compression bolts versus that of the conventional anatomic plate and cancellous scr... The purpose of this study was to compare the biomechanical stability obtained by using our technique featured an anatomical plate and compression bolts versus that of the conventional anatomic plate and cancellous screws in the fixation of intraarticular calcaneal fractures.Eighteen fresh frozen lower limbs of cadavers were used to create a reproductive Sanders type-Ⅲ calcaneal fracture model by using osteotomy.The calcaneus fractures were randomly selected to be fixed either using our anatomical plate and compression bolts or conventional anatomic plate and cancellous screws.Reduction of fracture was evaluated through X radiographs.Each calcaneus was successively loaded at a frequency of 1 Hz for 1000 cycles through the talus using an increasing axial force 20 N to 200 N and 20 N to 700 N,representing the partial weight bearing and full weight bearing,respectively,and then the specimens were loaded to failure.Data extracted from the mechanical testing machine were recorded and used to test for difference in the results with the Wilcoxon signed rank test.No significant difference was found between our fixation technique and conventional technique in displacement during 20-200 N cyclic loading(P=0.06),while the anatomical plate and compression bolts showed a great lower irreversible deformation during 20-700 N cyclic loading(P=0.008).The load achieved at loss of fixation of the constructs for the two groups had significant difference:anatomic plate and compression bolts at 3839.6±152.4 N and anatomic plate and cancellous screws at 3087.3±58.9 N(P=0.008).There was no significant difference between the ultimate displacements.Our technique featured anatomical plate and compression bolts for calcaneus fracture fixation was demonstrated to provide biomechanical stability as good as or better than the conventional anatomic plate and cancellous screws under the axial loading.The study supports the mechanical viability of using our plate and compression bolts for the fixation of calcaneal fracture. 展开更多
关键词 calcaneal fracture anatomic plate fixation compression bolts conventional screws biomechanical testing
下载PDF
Usage of buttress plate internal fixation associated with autografting of fibula and iliac bone for the treatment of distal femoral C_3 type fracture
3
作者 李衡 《外科研究与新技术》 2005年第3期176-177,共2页
To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture usin... To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture using buttress plate associated with antografting of fibula and iliac bone were analyzed retrospectively.Results All cases were followed up for an average of 24 months(8~55 months).The average time of octets bridge forming were 4 months(3~5 months) while the average time for bone union were 8 months (6~14 months).According to Shelbourne rating system,result of all 18 cases were excellent and no malunion,infection were found.Conclusion Buttress plate associated with antografting of fibula and iliac bone is an effective alternative for the treatment of distal femoral C3 type fracture.It can provide more stable fixation to the bone and earlier functional exercises can be achieved.5 refs,3 figs,1 tab. 展开更多
关键词 Usage of buttress plate internal fixation associated with autografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture
下载PDF
Neutralization versus Compression Plate on Lateral Malleolus Fracture:Is Lag Screw Necessary? 被引量:1
4
作者 Ahmet Oztermeli Sinan Karaca +1 位作者 Firat Fidan Ozgun Karakus 《Open Journal of Orthopedics》 2019年第4期81-88,共8页
Introduction: Our aim was to compare clinical and radiological results of lateral malleolus fracture treated with neutralization and compression plate. Material and Methods: 54 patients with isolated lateral malleolus... Introduction: Our aim was to compare clinical and radiological results of lateral malleolus fracture treated with neutralization and compression plate. Material and Methods: 54 patients with isolated lateral malleolus fractures treated between March 2012 and April 2015 at Fatih Sultan Mehmet Training and Research Hospital were evaluated with the Ankle-Hindfoot Scale of the American Orthopedic Foot and Ankle Society (AOFAS) score (excellent, ≥90;good, 75 - 89;acceptable, 50 - 74;poor, Results: There was no significant change in AOFAS, VAS, PSS and the union rates between two plating techniques. Conclusion: Similar results have shown both of two plating techniques were successful treating isolated lateral malleolus fracture. 展开更多
关键词 Lateral Malleol FRACTURE Ankle Fracture Lag Screw plate fixation
下载PDF
Rib Osteosynthesis for Sub-Acute Management of a Flail Chest in a Tertiary Centre in a Low-Middle Income Country of Sub-Saharan Africa: Case Report at Douala Laquintinie Hospital
5
作者 Fabrice Stéphane Arroye Betou Nyankoue Mebouinz Ferdinand +11 位作者 Guy Aristide Bang Kobe Folkabo Zephany Banga Nkomo Douglas Moussa Seck Diop Abdoul Lahad Mbeng Marcella Derboise Christelle Biyouma Noel Essomba Souleyman Diatta Handy Eone Daniel Arthur Essomba Hassan Ndiaye Maurice Aurelien Sosso 《Open Journal of Thoracic Surgery》 2024年第1期1-16,共16页
Background: Costal fracture surgical is still a debate, therefore we shall select between early and delay surgical management. Case Report: We are reporting two cases of post road traffic clash delay ribs fractures os... Background: Costal fracture surgical is still a debate, therefore we shall select between early and delay surgical management. Case Report: We are reporting two cases of post road traffic clash delay ribs fractures osteosynthesis involving a 63-year-old man with multistage fractures on the left and pulmonary pinning of one of the costal arches, complicated by a homolateral haemothorax and a 41-year-old man with a bilateral flail chest. Conclusion: The simple postoperative course and the immediate postoperative improvement in the patient’s clinical respiratory condition enabled us to discuss the time frame for management, in this case the indication for early or later surgery. 展开更多
关键词 Flail Chest fixation plate Rib Fracture OSTEOSYNTHESIS
下载PDF
Effect of Locking Compression Plate on the Treatment of Limb Fracture and the Effect of Operative Success Rate and Postoperative Recovery Time
6
作者 Hanping Huang 《Journal of Integrative Medicine(双语)》 2020年第1期9-11,共3页
Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly... Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly divided into control group(60 cases)and observation group(60 cases).The control group was treated with plate screw internal fixation,The observation group used locking compression plate internal fixation,Compare the effect of treatment,the success rate of operation and the time of postoperative recovery.results:compared the effective rate of the two groups,the observation group(93.33%)was significantly higher than the control group(75.00%).Compared with the two groups,the success rate of operation and the time of postoperative recovery,the observed composition power was higher than that of the control group,and the postoperative recovery time was lower than that of the control group,P<0.05.Conclusion:The use of locking compression plate for the treatment of limb fracture can significantly increase the probability of successful operation,shorten the recovery time after operation,the overall curative effect is ideal,and the clinical popularization value is high. 展开更多
关键词 Limb fracture Locking compression plate internal fixation plate screw internal fixation EFFECT Surgical success rate Postoperative recovery time
下载PDF
Clinical Effectiveness of the Plate Screw Internal Fixation Technique in the Treatment of Patients with Traumatic Fractures of Long Bones in the Lower Extremities
7
作者 Yong Cai 《Proceedings of Anticancer Research》 2024年第3期115-120,共6页
Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 20... Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application. 展开更多
关键词 plate screw internal fixation technique Traumatic fractures Long bones in the lower extremities Effectiveness
下载PDF
Postoperative Fracture Healing Effects of Locking Compression Plate for the Treatment of Limb Fractures
8
作者 Bin Zhao Jingli Dou +1 位作者 Rongcai Zhang Mingming Wang 《Journal of Clinical and Nursing Research》 2021年第3期24-27,共4页
Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in ou... Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in our hospital from November 2019 to November 2020 were selected.In order to study the effective treatment method,the random-number table method was used in this study to divide the patients into two groups,namely the experimental group and the control group,and the locking compression plate treatment method and the pure plate and screw internal fixation treatment method were administered respectively to study their clinical application effects.Results:Compared with the control group,patients in the experimental group had a lower incidence of complications,shorter hospitalizations and shorter recovery time.Meanwhile,the experimental group had a better quality of recovery,and all data were significantly different from those of the control group,P<0.05,the intervention effect of the experimental group was better.Conclusion:The application of the locking compression plate in the treatment of patients with limb fractures is more conducive to promoting the postoperative healing of the patients'fractures,reducing the incidence of postoperative complications,and promoting the rapid recovery of patients,which has positive significance for clinical development. 展开更多
关键词 Locking compression plate treatment method Simple plate and screw internal fixation treatment method Patients with limb fractures
下载PDF
EFFECT OF INTERNAL FIXATION PLATES ON MICROCIRCULATION IN UNDER-PLATE CORTICAL BONES MICROANGIOGRAPHY AND SCANNING ELECTRONMICROSCOPY 被引量:1
9
作者 王友 戴克戎 《Chinese Medical Journal》 SCIE CAS CSCD 1994年第12期51-55,共5页
To elucidate the effect of the internal fixation plates on the local bone blood sapply, we used microangiography and scanning electron microscopy to observe the morphological changes of microcirculation in the cortica... To elucidate the effect of the internal fixation plates on the local bone blood sapply, we used microangiography and scanning electron microscopy to observe the morphological changes of microcirculation in the cortical bones obtained from intact rabbit tibiae on which plates of two different stiffness had been fixed for comparison. The results indicated that both rigid stainless steel plate and less rigid methyl methacrylate plate could induce the bone microcirculation under the plate to undergo a process from early depression to late reactive recruitment. The features of the microcircuiation recruitment such as vascular number, arrangement and dilatation varied with plates of different stiffness and were more obvious in the cortex fixed by rigid stainless steel plate. 展开更多
关键词 In MMA EFFECT OF INTERNAL fixation plateS ON MICROCIRCULATION IN UNDER-plate CORTICAL BONES MICROANGIOGRAPHY AND SCANNING ELECTRONMICROSCOPY
原文传递
Quantitative Histological Study on Changes of the Cortical Bones after Internal Fixation with Plates of Different Rigidity 被引量:2
10
作者 Wang You et al. Dept Orth, Ninth People’s Hospital, Shanghai Second Med Uni, Shanghai 200011. Chin J Orth 《Chinese Medical Journal》 SCIE CAS CSCD 1995年第11期30-30,共1页
In an effect to explore the potemtial role of bone microcirculation causing plate-induced reginal osteoporosis
关键词 Quantitative Histological Study on Changes of the Cortical Bones after Internal fixation with plates of Different Rigidity
原文传递
Comparisons in finite element analysis of minimally invasive, locking,and non-locking plates systems used in treating calcaneal fractures of Sanders type Ⅱ and type Ⅲ 被引量:12
11
作者 He Kai Fu Su +2 位作者 Liu Song Wang Zhifa Jin Dan 《Chinese Medical Journal》 SCIE CAS CSCD 2014年第22期3894-3901,共8页
Background Calcaneal fractures are relatively common but complex,while the treatment of these fractures is still controversial.The objective of this study was to compare the biomechanical stability of minimally invasi... Background Calcaneal fractures are relatively common but complex,while the treatment of these fractures is still controversial.The objective of this study was to compare the biomechanical stability of minimally invasive,locking,and non-locking plating systems used for fixing Sanders type Ⅱ and type Ⅲ calcaneal fractures.Finite element analysis was used for comparing the three types of plating systems.This study helped in guiding the clinical management of calcaneal fractures.Methods The CT data acquired from a volunteer was used to construct a finite element model of calcaneus.The fracture lines were made according to Sanders type Ⅱ (A,B,C) and type Ⅲ (AB,AC,BC) and six calcaneal fractures models were constructed accordingly.Three fixation methods used in clinical treatment were simulated by design tools (minimally invasive plating with percutaneous screws,Y-size non-locking plating,and locking plating) and then fixed to these fracture models with the help of clinical principles.The single minimally invasive plating fixation was also tested to compare the function of percutaneous screws.Then,the neutral force was applied on established methods.The displacement and presses distribution condition in various plating models were analyzed and compared.Results The levels of displacement and compressive press on the bone around fixation or strains on plating were within the physiological limit,indicating that the three methods were suitable for application.Compared with the locked and unlocked plates,the minimally invasive plating caused a relatively lower displacement without the high stress in bone or fixation.The minimum stress in fixation was observed in locking plate as the distribution of stress was concentrated in the anterior part of locking plate.Conclusions The minimally invasive plating method could be a better alternative method in treating Sanders type Ⅱ and type Ⅲ calcaneal fractures.The observed stiffness of locking plate was not obviously stronger than unlocked plate. 展开更多
关键词 calcaneal fractures Sanders type finite element analysis fixation minimally invasive plate
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部