Objective: To examine the correlation between plasma hCG results obtained with the new i-STAT® hCG point of care test with those concomitantly obtained from the central hospital laboratory utilizing the same pa...Objective: To examine the correlation between plasma hCG results obtained with the new i-STAT® hCG point of care test with those concomitantly obtained from the central hospital laboratory utilizing the same patient samples. Methods: Prospective cross-sectional laboratory test evaluation. We compared plasma hCG results obtained with the i-STAT® hCG test (Abbott Point of Care, Princeton, NJ, USA) with Architect Ci8200 (Abbott Laboratories, Abbott Park, IL, USA). We also calculated the total coefficient of variation (CV) for the i-STAT® method. Results: The two methods showed a good linear correlation (R2 = 0.994;slope 1.03) and CV for the i-STAT® method was 2.1% - 5.2%. Conclusion: We suggest that the i-STAT® hCG blood assay could be used as a complement to urine hCG assays in clinical situations when rapid test results are needed and urine is not available.展开更多
We have presented a three dimensional optical protein chip that fulfills the demanding for point-of-care diagnostics in terms of ease-of-use (one step assay), miniaturization (5 μl). The artful combination of magneti...We have presented a three dimensional optical protein chip that fulfills the demanding for point-of-care diagnostics in terms of ease-of-use (one step assay), miniaturization (5 μl). The artful combination of magnetic nanoparticles on chip and total internal reflection imaging (TIRI) technology permits the sensitive and rapid detection of hs-CRP (high-sensitivity C-reactive protein). The whole test was complete within 10 min using “all in one step” assay with a limit of detection of 0.1 ng/mL hs-CRP. The measuring range for hs-CRP could be extended to 10 ng/mL. The chip can also be used to detect more parameters in blood samples.展开更多
In the event of blood vessel damage, human platelets are promptly recruited on the site of injury and, after their adhesion, activation and aggregation, prevent blood loss with the formation of a clot. The consequence...In the event of blood vessel damage, human platelets are promptly recruited on the site of injury and, after their adhesion, activation and aggregation, prevent blood loss with the formation of a clot. The consequence of abnormal regulation can be either hemorrhage or the development of thrombosis. Qualitative and/or quantitative defects in platelets promote bleeding, whereas the residual reactivity of platelets, despite antiplatelet therapies, play an important role in promoting arterial thrombotic complications. Platelet function is traditionally assessed to investigate the origin of a bleeding syndrome, to predict the risk of bleeding prior surgery or during pregnancy or to monitor the efficacy of antiplatelet therapy in thrombotic syndromes that, now, can be considered a new discipline. "Old" platelet function laboratory tests such as the evaluation of bleeding time and the platelet aggregation analysis inplatelet-rich plasma are traditionally utilized to aid in the diagnosis and management of patients with platelet and hemostatic disorders and used as diagnostic tools both in bleeding and thrombotic diathesis in specialized laboratories. Now, new and renewed automated systems have been introduced to provide a simple, rapid assessment of platelet function including point of care methods. These new methodologies are also suitable for being used in non-specialized laboratories and in critical area for assessing platelet function in whole blood without the requirement of sample processing. Some of these methods are also beginning to be incorporated into routine clinical use and can be utilized as not only as first panel for the diagnosis of platelet dysfunction, but also for monitoring anti-platelet therapy and to potentially assess risk of both bleeding and/or thrombosis.展开更多
目的研究联合国驻黎巴嫩临时部队(UNIFIL)我军和外军维和官兵部分生化指标的差异性,初步探讨POCT(pointof care testing,POCT)干式生化分析仪在维和检验中的应用价值。方法以UNIFIL外军维和官兵作为观察组(n=115~303),中国维和工兵营...目的研究联合国驻黎巴嫩临时部队(UNIFIL)我军和外军维和官兵部分生化指标的差异性,初步探讨POCT(pointof care testing,POCT)干式生化分析仪在维和检验中的应用价值。方法以UNIFIL外军维和官兵作为观察组(n=115~303),中国维和工兵营作为对照组(n=167),同时对两组生化检验数据均值行t检验分析其统计学差异性。结果与167例中国赴黎维和工兵营官兵生化检测结果相比较,赴黎维和外军官兵生化检测结果中ALB、TBIL、GPT、GOT、LDH、GLU、TCH显著升高(P<0.01),CRE显著降低(P<0.001),TPRO、TG差异无统计学意义(P>0.05)。结论 UNIFIL外军和中国维和官兵部分生化指标存在统计学差异性,建议中国维和二级医院检验科应分别建立不同的判断标准;POCT干式生化分析仪在维和检验医学中保障作用优势明显。展开更多
文摘Objective: To examine the correlation between plasma hCG results obtained with the new i-STAT® hCG point of care test with those concomitantly obtained from the central hospital laboratory utilizing the same patient samples. Methods: Prospective cross-sectional laboratory test evaluation. We compared plasma hCG results obtained with the i-STAT® hCG test (Abbott Point of Care, Princeton, NJ, USA) with Architect Ci8200 (Abbott Laboratories, Abbott Park, IL, USA). We also calculated the total coefficient of variation (CV) for the i-STAT® method. Results: The two methods showed a good linear correlation (R2 = 0.994;slope 1.03) and CV for the i-STAT® method was 2.1% - 5.2%. Conclusion: We suggest that the i-STAT® hCG blood assay could be used as a complement to urine hCG assays in clinical situations when rapid test results are needed and urine is not available.
文摘We have presented a three dimensional optical protein chip that fulfills the demanding for point-of-care diagnostics in terms of ease-of-use (one step assay), miniaturization (5 μl). The artful combination of magnetic nanoparticles on chip and total internal reflection imaging (TIRI) technology permits the sensitive and rapid detection of hs-CRP (high-sensitivity C-reactive protein). The whole test was complete within 10 min using “all in one step” assay with a limit of detection of 0.1 ng/mL hs-CRP. The measuring range for hs-CRP could be extended to 10 ng/mL. The chip can also be used to detect more parameters in blood samples.
文摘In the event of blood vessel damage, human platelets are promptly recruited on the site of injury and, after their adhesion, activation and aggregation, prevent blood loss with the formation of a clot. The consequence of abnormal regulation can be either hemorrhage or the development of thrombosis. Qualitative and/or quantitative defects in platelets promote bleeding, whereas the residual reactivity of platelets, despite antiplatelet therapies, play an important role in promoting arterial thrombotic complications. Platelet function is traditionally assessed to investigate the origin of a bleeding syndrome, to predict the risk of bleeding prior surgery or during pregnancy or to monitor the efficacy of antiplatelet therapy in thrombotic syndromes that, now, can be considered a new discipline. "Old" platelet function laboratory tests such as the evaluation of bleeding time and the platelet aggregation analysis inplatelet-rich plasma are traditionally utilized to aid in the diagnosis and management of patients with platelet and hemostatic disorders and used as diagnostic tools both in bleeding and thrombotic diathesis in specialized laboratories. Now, new and renewed automated systems have been introduced to provide a simple, rapid assessment of platelet function including point of care methods. These new methodologies are also suitable for being used in non-specialized laboratories and in critical area for assessing platelet function in whole blood without the requirement of sample processing. Some of these methods are also beginning to be incorporated into routine clinical use and can be utilized as not only as first panel for the diagnosis of platelet dysfunction, but also for monitoring anti-platelet therapy and to potentially assess risk of both bleeding and/or thrombosis.
文摘目的研究联合国驻黎巴嫩临时部队(UNIFIL)我军和外军维和官兵部分生化指标的差异性,初步探讨POCT(pointof care testing,POCT)干式生化分析仪在维和检验中的应用价值。方法以UNIFIL外军维和官兵作为观察组(n=115~303),中国维和工兵营作为对照组(n=167),同时对两组生化检验数据均值行t检验分析其统计学差异性。结果与167例中国赴黎维和工兵营官兵生化检测结果相比较,赴黎维和外军官兵生化检测结果中ALB、TBIL、GPT、GOT、LDH、GLU、TCH显著升高(P<0.01),CRE显著降低(P<0.001),TPRO、TG差异无统计学意义(P>0.05)。结论 UNIFIL外军和中国维和官兵部分生化指标存在统计学差异性,建议中国维和二级医院检验科应分别建立不同的判断标准;POCT干式生化分析仪在维和检验医学中保障作用优势明显。