Wave-shaped microfluidic chip assisted point-of-care testing for accurate and rapid diagnosis of infections 被引量:3
1
作者 Bin-Feng Yin Xin-Hua Wan +2 位作者 Ming-Zhu Yang Chang-Cheng Qian A.S.M.Muhtasim Fuad Sohan 《Military Medical Research》 SCIE CAS CSCD 2022年第5期553-564,共12页
Background:Early diagnosis and classification of infections increase the cure rate while decreasing complications,which is significant for severe infections,especially for war surgery.However,traditional methods rely ... Background:Early diagnosis and classification of infections increase the cure rate while decreasing complications,which is significant for severe infections,especially for war surgery.However,traditional methods rely on laborious operations and bulky devices.On the other hand,point-of-care(POC)methods suffer from limited robustness and accuracy.Therefore,it is of urgent demand to develop POC devices for rapid and accurate diagnosis of infections to fulfill on-site militarized requirements.Methods:We developed a wave-shaped microfluidic chip(WMC)assisted multiplexed detection platform(WMC-MDP).WMC-MDP reduces detection time and improves repeatability through premixing of the samples and reaction of the reagents.We further combined the detection platform with the streptavidin–biotin(SA-B)amplified system to enhance the sensitivity while using chemiluminescence(CL)intensity as signal readout.We realized simultaneous detection of C-reactive protein(CRP),procalcitonin(PCT),and interleukin-6(IL-6)on the detection platform and evaluated the sensitivity,linear range,selectivity,and repeatability.Finally,we finished detecting 15 samples from volunteers and compared the results with commercial ELISA kits.Results:Detection of CRP,PCT,and IL-6 exhibited good linear relationships between CL intensities and concentrations in the range of 1.25–40μg/ml,0.4–12.8 ng/ml,and 50–1600 pg/ml,respectively.The limit of detection of CRP,PCT,and IL-6 were 0.54μg/ml,0.11 ng/ml,and 16.25 pg/ml,respectively.WMC-MDP is capable of good adequate selectivity and repeatability.The whole detection procedure takes only 22 min that meets the requirements of a POC device.Results of 15 samples from volunteers were consistent with the results detected by commercial ELISA kits.Conclusions:WMC-MDP allows simultaneous,rapid,and sensitive detection of CRP,PCT,and IL-6 with satisfactory selectivity and repeatability,requiring minimal manipulation.However,WMC-MDP takes advantage of being a microfluidic device showing the coefficients of variation less than 10%enabling WMC-MDP to be a type of point-of-care testing(POCT).Therefore,WMC-MDP provides a promising alternative to POCT of multiple biomarkers.We believe the practical application of WMC-MDP in militarized fields will revolutionize infection diagnosis for soldiers. 展开更多
关键词 point-of-care testing(poct) Infection markers Wave-shaped microfluidic chip CHEMILUMINESCENCE Multiplex detection
下载PDF
Point-of-Care Testing Using Three Dimensional Optical Biosensor Based on Microfluidic Technology
2
作者 Chunxiu Liu Haoyuan Cai +4 位作者 Jian Jia Tianyang Cao Tong Li Tianjun Ma Chang Liu 《Journal of Biosciences and Medicines》 2016年第12期56-61,共6页
We have presented a three dimensional optical protein chip that fulfills the demanding for point-of-care diagnostics in terms of ease-of-use (one step assay), miniaturization (5 μl). The artful combination of magneti... We have presented a three dimensional optical protein chip that fulfills the demanding for point-of-care diagnostics in terms of ease-of-use (one step assay), miniaturization (5 μl). The artful combination of magnetic nanoparticles on chip and total internal reflection imaging (TIRI) technology permits the sensitive and rapid detection of hs-CRP (high-sensitivity C-reactive protein). The whole test was complete within 10 min using “all in one step” assay with a limit of detection of 0.1 ng/mL hs-CRP. The measuring range for hs-CRP could be extended to 10 ng/mL. The chip can also be used to detect more parameters in blood samples. 展开更多
关键词 point-of-care testing (poct) Three Dimensional Optical Chip HS-CRP
下载PDF
A smartphone-based automated fluorescence analysis system for point-of-care testing of Hg(Ⅱ)
3
作者 Yafei Chen Ke Zhang +1 位作者 Yuan Liu Chunsun Zhang 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2022年第5期28-40,共13页
This work demonstrates a smartphone-based automated fluorescence analysis system(SAFAS)for point-of-care testing(POCT)of Hg(Ⅱ).This system consists of three modules.The smartphone module is used to provide an excitat... This work demonstrates a smartphone-based automated fluorescence analysis system(SAFAS)for point-of-care testing(POCT)of Hg(Ⅱ).This system consists of three modules.The smartphone module is used to provide an excitation light source,and to collect and analyze fluorescent images.The dark box module is applied to integrate the desired optical elements and offers a dark environment.The cost of the integrated dark box mainly includes the upper cover,box body,lower bottom,¯xture and some optical elements which is about$109.The chip module is used for fluorescence sensing,which is composed of an upper plate,bottom plate and cloth-based chip.Due to the integration of multiple smartphone functions,the SAFAS eliminates the need for additional power sources,light sources and analysis systems.The dark box and upper and bottom plates are made by 3D printer.The cloth-based chip(about$0.005 for each chip)is fabricated using the wax screenprinting technique,with no need for expensive and complex fabrication equipments.To our knowledge,the cloth-based microfluidic fluorescence detection method combined with smartphone functions is first reported.By using optimal conditions,the designed system can realize the quantitative detection of Hg(Ⅱ),which has a linear range of 0.001–100μgmL^(-1)and a detection limit of 0.5 ngmL^(-1).Additionally,the SAFAS has been successfully applied for detecting Hg(Ⅱ)in actual water samples,with recoveries of 100.1%–111%,RSDs of 3.88%–9.74%,and fast detection time of about 1 min.Obviously,the proposed SAFAS has the advantages of high sensitivity,wide dynamic range,acceptable reproducibility,good stability and low cost.Therefore,it is believed that the presented SAFAS has great potential to perform the POCT of Hg(II)in different water samples. 展开更多
关键词 SMARTPHONE automated fluorescence detection cloth-based chip point-of-care testing Hg(II).
下载PDF
Point-of-Care Testing vs. Laboratory Testing during High Patient Volume Situations
4
作者 Jonathan McCoy Robert Eisenstein +5 位作者 Channing Hui Greg Corcoran Chris Kilker Pamela Ohman-Strickland Mark Merlin Clifton Lacy 《Open Journal of Emergency Medicine》 2019年第4期49-56,共8页
Introduction: Our aim was to determine what patient volume, if any, in-laboratory testing provides results faster than Point-of-Care-Testing (POCT). Methods: To evaluate POCT effectiveness during high volume situation... Introduction: Our aim was to determine what patient volume, if any, in-laboratory testing provides results faster than Point-of-Care-Testing (POCT). Methods: To evaluate POCT effectiveness during high volume situations, POCT was compared to in-laboratory testing during busy periods with large numbers of patients. Our setting was an urban level 1 trauma center with an academic emergency medicine department (ED) and annual patient volume of 70,000. Patients seen requiring laboratory testing during peak volume between 11 a.m. and 7 p.m. were enrolled over a five-week period. One tube of blood was sent to the laboratory and the other tube was run in the ED using POCT. Turnaround time was recorded as time from when the tube was received to when the result was available. We also completed a time-motion study to assess the number of POCT machines that would be needed to process the entire average hourly hospital laboratory volume. Results: We collected 539 hematology and chemistry specimens. The POCT group was significantly faster than in-laboratory testing, with mean POCT [complete blood count (CBC) and chemistry] 3.5 minutes compared to in-laboratory CBC test time of 30.9 minutes and chemistry test time of 55 minutes. As the volume of samples peaked, there was a slight but insignificant decrease in POCT turnaround time. If POCT was used to process the entire average hospital laboratory volume which approached 54 samples an hour, 3 POCT machines would be necessary to maintain turnaround times. Conclusion: Even during ED high volume situations, POCT provided results significantly faster than in-laboratory testing. 展开更多
关键词 point-of-care testing EMERGENCY DEPARTMENT DISASTER MEDICINE
下载PDF
Recent progress on rapid diagnosis of COVID-19 by point-of-care testing platforms
5
作者 Ya-Nan Tang Dingding Jiang +2 位作者 Xuejun Wang Yunqi Liu Dacheng Wei 《Chinese Chemical Letters》 SCIE CAS CSCD 2024年第3期66-75,共10页
The outbreak of COVID-19 has drawn great attention around the world.SARS-CoV-2 is a highly infectious virus with occult transmission by many mutations and a long incubation period.In particular,the emergence of asympt... The outbreak of COVID-19 has drawn great attention around the world.SARS-CoV-2 is a highly infectious virus with occult transmission by many mutations and a long incubation period.In particular,the emergence of asymptomatic infections has made the epidemic even more severe.Therefore,early diagnosis and timely management of suspected cases are essential measures to control the spread of the virus.Developing simple,portable,and accurate diagnostic techniques for SARS-CoV-2 is the key to epidemic prevention.The advantages of point-of-care testing technology make it play an increasingly important role in viral detection and screening.This review summarizes the point-of-care testing platforms developed by nucleic acid detection,immunological detection,and nanomaterial-based biosensors detection.Furthermore,this paper provides a prospect for designing future highly accurate,cheap,and convenient SARS-CoV-2 diagnostic technology. 展开更多
关键词 COVID-19 point-of-care testing platforms Nucleic acid detection Asymptomatic infection Biosensors
原文传递
A Point-of-Care Test System for Biochemical Blood Analysis Based on ADUC824
6
作者 Hui Wang Qing Tian +3 位作者 Liying Jiang Chunxiu Liu Zonghui Guo Xinxia Cai 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期75-79,共5页
A point-of-care test system has been studied in this paper.It was used to determine substances in blood such as Hemoglobin (HB),Aspartate Aminotransferase (AST),Creatine Kinase (CK) and so on.Based on the principle ... A point-of-care test system has been studied in this paper.It was used to determine substances in blood such as Hemoglobin (HB),Aspartate Aminotransferase (AST),Creatine Kinase (CK) and so on.Based on the principle of amperometric determination,the research on detecting weak current signals was carried on.At the same time as to the weak signals (nA level),magnifying,sampling and processing the signals were also studied.Controlled by ADUC824 and assisted by other units, every substance could be determined automatically and rapidly integrated with the corresponding biosensor.In the experiment, the minimum detectable current of the instrument (YT2005-1) is 0.2 nA.With regard to the 1 nA which the experiment demanded,it could be up to the mustard.And the system can provide results in 180 s with a long term stability. 展开更多
关键词 point-of-care test ADUC824 weak signals HB AST and CK
下载PDF
Point-of-care ultrasound for critically-ill patients: A mini-review of key diagnostic features and protocols 被引量:1
7
作者 Yie Hui Lau Kay Choong See 《World Journal of Critical Care Medicine》 2022年第2期70-84,共15页
Point-of-care ultrasonography(POCUS)for managing critically ill patients is increasingly performed by intensivists or emergency physicians.Results of needs surveys among intensivists reveal emphasis on basic cardiac,l... Point-of-care ultrasonography(POCUS)for managing critically ill patients is increasingly performed by intensivists or emergency physicians.Results of needs surveys among intensivists reveal emphasis on basic cardiac,lung and abdominal ultrasound,which are the commonest POCUS modalities in the intensive care unit.We therefore aim to describe the key diagnostic features of basic cardiac,lung and abdominal ultrasound as practised by intensivists or emergency physicians in terms of accuracy(sensitivity,specificity),clinical utility and limitations.We also aim to explore POCUS protocols that integrate basic cardiac,lung and abdominal ultrasound,and highlight areas for future research. 展开更多
关键词 Critical care ECHOCARDIOGRAPHY point-of-care testing Sensitivity and specificity ULTRASONOGRAPHY
下载PDF
POCT技术在军事和突发事件医学救援中的应用现状与思考
8
作者 张淑艳 柯可 +2 位作者 李宁一 高蕾 刘杰 《中国急救复苏与灾害医学杂志》 2023年第3期407-410,共4页
现场快速检验技术(point of care testing,POCT)因具有快(报告结果快)、边(患者身边)、便(操作简便)和易(读取结果容易)等优势,广泛应用于军事行动及战备、事故灾难、反恐等突发事件的救援现场。主要对POCT技术在军事和突发事件医学救... 现场快速检验技术(point of care testing,POCT)因具有快(报告结果快)、边(患者身边)、便(操作简便)和易(读取结果容易)等优势,广泛应用于军事行动及战备、事故灾难、反恐等突发事件的救援现场。主要对POCT技术在军事和突发事件医学救援检验方法学、检验项目和检验模块装备等方面的应用进行阐述,并对POCT技术在应用中需改进的问题以及该技术在未来发展方向上应该侧重提高的方面进行了讨论和分析。 展开更多
关键词 现场快速检验(poct) 现场救治 检验模块 突发事件
下载PDF
Point-of-care testing for lysine concentration in swine serum via blue-emissive carbon dot-entrapped microfluidic chip
9
作者 Chizhu Ding Xiang Chen +5 位作者 Xiaoyu Chen Yue Liu Menglin Xia Ziyi He Qinshu Kang Xianghua Yan 《Animal Nutrition》 SCIE CSCD 2023年第1期236-244,共9页
Lysine is one of the essential amino acids and plays a vital role in the growth,development and health of pigs.Blood lysine concentration is a direct indication of lysine status;however,current methods can not satisfy... Lysine is one of the essential amino acids and plays a vital role in the growth,development and health of pigs.Blood lysine concentration is a direct indication of lysine status;however,current methods can not satisfy the demands for rapid and on-site lysine concentration measurement of swine serum.Here,we developed blue-emissive nitrogen-doped carbon dots as a fluorescence probe for the determination of lysine with high fluorescence quantum yield,stability,sensitivity and specificity.The carbon dots were entrapped within hydrogel microstructures to fabricate microfluidic chips for rapid assay for lysine quantification.We further developed an imaging attachment to integrate the microfluidic chip and a smartphone into a portable point-of-care testing platform.This platform requires only 3μL sample and has a linear detection range of 25 to 300μmol/L with a limit of detection less than 16μmol/L,which covers the normal range of lysine concentration in swine serum.We tested lysine concentration in swine serum using this platform with high accuracy,low sample consumption,and within 3 min.Together,these results may provide a rapid and portable platform for dynamic monitoring of swine lysine status and contribute to precise feed formula modulation with low-protein diet strategy. 展开更多
关键词 LYSINE Swine serum Carbon dots MICROFLUIDICS point-of-care testing
原文传递
DropLab:an automated magnetic digital microfluidic platform for sample-to-answer point-of-care testing—development and application to quantitative immunodiagnostics
10
作者 Xuyang Hu Xiangyu Gao +2 位作者 Songlin Chen Jinhong Guo Yi Zhang 《Microsystems & Nanoengineering》 SCIE CSCD 2023年第1期241-252,共12页
In point-of-care testing(POCT),tests are performed near patients and results are given rapidly for timely clinical decisions.Immunodiagnostic assays are one of the most important analyses for detecting and quantifying... In point-of-care testing(POCT),tests are performed near patients and results are given rapidly for timely clinical decisions.Immunodiagnostic assays are one of the most important analyses for detecting and quantifying protein-based biomarkers.However,existing POCT immunodiagnostics mainly rely on the lateral flow assay(LFA),which has limited sensitivity or quantification capability.Although other immunodiagnostic assays,such as enzyme-linked immunosorbent assays(ELISAs),offer more sensitive and quantitative results,they require complex liquid manipulations that are difficult to implement in POCT settings by conventional means.Here,we show the development of DropLab,an automated sample-in-answer-out POCT immunodiagnostic platform based on magnetic digital microfluidic(MDM)technology.DropLab performs microbead-based ELISA in droplets to offer more sensitive and quantitative testing results.The intricate liquid manipulations required for ELISA are accomplished by controlling droplets with magnetic microbeads using MDM technology,which enables us to achieve full automation and easy operations with DropLab.Four ELISAs(the sample in triplicates and a negative control)can be run in parallel on the thermoformed disposable chip,which greatly improves the throughput and accuracy compared to those of other POCT immunodiagnostic devices.DropLab was validated by measuring two protein targets and one antibody target.The testing results showed that the limit of detection(LOD)of DropLab matched that of the conventional ELISA in a microwell plate.DropLab brings MDM one step closer to being a viable medical technology that is ready for real-world POCT applications. 展开更多
关键词 poct testing AUTOMATED
原文传递
基于POCT的医院血糖信息化管理实践与效果分析
11
作者 陈艳 涂文婷 +3 位作者 王红霞 魏怜恤 钱素静 吴婷婷 《医院管理论坛》 2023年第5期91-93,共3页
目的 探索基于即时检验技术的全院联动血糖信息化系统对患者血糖进行管理。方法 应用即时检验技术,实现患者床旁血糖即时检测,构建患者异常血糖管理体系,实现血糖危急值闭环管理。结果 2022年1月至10月期间测量血糖57497人,其中达标人数... 目的 探索基于即时检验技术的全院联动血糖信息化系统对患者血糖进行管理。方法 应用即时检验技术,实现患者床旁血糖即时检测,构建患者异常血糖管理体系,实现血糖危急值闭环管理。结果 2022年1月至10月期间测量血糖57497人,其中达标人数48528人,达标率84.80%。共测量1236398次,其中达标次数407517次,达标率32.96%。2022年1月至10月期间,低血糖共出现24237次,占比1.96%;异常低值共出现13333次,占比1.08%;危急低值共出现2536次,占比0.21%;异常高值共出现804644次,占比65.08%;危急高值共出现87166次,共占比7.05%。结论 基于即时检验技术的院内血糖信息化管理可简化医护人员劳动,提高工作效率,减少医疗差错,同时可对患者血糖进行全面专业管理,提高血糖危急值管理水平。 展开更多
关键词 即时检验 血糖 信息化管理
下载PDF
新型检测技术在即时检测(POCT)中的应用
12
作者 陈剑 《现代科学仪器》 2023年第4期5-10,共6页
即时检验(point-of-care testing,POCT),又称现场快检或床旁快检,是一种可以在现场及时完成检测并报告结果的检测方式。然而,传统POCT难以充分满足精准定量与自动化检测等需求,精准诊疗时代急切需要更准、更快、更便利、更普惠的新型POC... 即时检验(point-of-care testing,POCT),又称现场快检或床旁快检,是一种可以在现场及时完成检测并报告结果的检测方式。然而,传统POCT难以充分满足精准定量与自动化检测等需求,精准诊疗时代急切需要更准、更快、更便利、更普惠的新型POCT产品。随着生物学、化学、电子信息学、工业加工等学科的技术革新和进步,层出不穷的创新型POCT诊断技术在临床诊疗、公共卫生防控及大健康管理中展现出了极具优势的应用价值和广阔的应用前景。本综述旨在对POCT发展、新技术进行系统性概述,对传统检测技术与新型检测技术在POCT中应用进行讨论和前景展望。 展开更多
关键词 即时检验(poct) 传统检测技术 新型检测技术
下载PDF
即时检测仪器与电化学发光仪检测心脏标志物的对比研究
13
作者 刘文娟 郭盼 +5 位作者 杜娟 张何锐 王雅平 王海龙 徐佳 李琦 《中国医学装备》 2024年第5期16-19,25,共5页
目的:对比分析两种即时检测(POCT)仪器与Roche电化学发光仪检测心脏标志物的相关关系,为临床检验选择POCT仪器提供参考。方法:选取2020年11月在中国中医科学院西苑医院就诊的20例患者血液样本,其浓度范围覆盖检测结果可报告范围,使用两... 目的:对比分析两种即时检测(POCT)仪器与Roche电化学发光仪检测心脏标志物的相关关系,为临床检验选择POCT仪器提供参考。方法:选取2020年11月在中国中医科学院西苑医院就诊的20例患者血液样本,其浓度范围覆盖检测结果可报告范围,使用两种POCT仪器(分别命名为仪器A和仪器B)检测血浆肌红蛋白(Myo)、肌酸激酶同工酶质量(CKMB mass)、心肌钙蛋白I(cTnI)、氨基末端脑钠肽前体(NT-proBNP)/B型钠尿肽(BNP)的浓度水平,以电化学分析仪检测结果为参考,分别采用pearson相关分析和Kappa检验评价两种POCT仪器与Roche电化学发光仪检测结果的相关性和一致性。结果:仪器A和仪器B检测结果与Roche电化学发光仪检测Myo、CK-MB mass、cTnI、NT-proBNP/BNP结果均有较好的相关性(r_(仪器A)=O.994、0.989、0.917、0.996,r_(仪器B)=0.928、0.934、0.883、0.977,P<0.05)。在一致性比较中,仪器A检测Myo、CK-MB mass、cTnI、NT-proBNP与电化学分析仪的符合率分别为90%、100%、70%和100%;仪器B检测结果的符合率分别为90%、95%、70%和100%,两种POCT仪器与Roche电化学发光仪均具有较好的一致性(Kappa_(仪器A)=0.798、1.00、0.429、1.00,Kappa_(仪器B)=0.794、0.886、0.429、1.00)。两种仪器的精密度均<10%。结论:两种POCT仪器均能满足临床检测要求,在检测心脏标志物时与电化学发光仪有较好的相关性。 展开更多
关键词 即时检测(poct)仪器 心脏标志物 电化学发光 分析性能
下载PDF
Sweat-Based in Vitro Diagnostics(IVD):From Sample Collection to Point-of-Care Testing(POCT) 被引量:1
14
作者 Mehenur Sarwar Pablo Rodriguez Chen-zhong Li 《Journal of Analysis and Testing》 EI 2019年第1期80-88,共9页
Sweat-based diagnostics offer an exciting avenue to noninvasively monitor analytes which had previously only been avail-able through painful blood draws.Sweat is enriched with physiologically valuable information,and ... Sweat-based diagnostics offer an exciting avenue to noninvasively monitor analytes which had previously only been avail-able through painful blood draws.Sweat is enriched with physiologically valuable information,and recent proteomic studies have identified numerous critical analytes which have highly correlated levels in blood,interstitial fluid and sweat.How-ever,usage of sweat for health monitoring has not been studied extensively due to the substantial challenge of assembling a composite clinic-ready device.Recent advances in soft electronics have made this goal realizable,as these devices can perform electronic or optical monitoring on a flexible substrate using small volumes of liquid.While this field is still in its infancy,this review examines the physiological composition of sweat,various improvements in material science that improve sensor design,existing FDA approvals,methods of extracting sweat and comparisons to blood-based tests.Furthermore,this review assesses the critical challenges which must be overcome for this type of technology to make it out of research laboratories and into continuous clinical use.We believe that once properly harnessed,sweat-based diagnostics can provide patients a painless monitoring tool which can be customized to track a wide variety of medical conditions from the comfort of a patient’s own home. 展开更多
关键词 Wearable sensors Sweat tests In vitro diagnostics Biomarkers pocts Sweat collection
原文传递
POCT血糖仪和生化分析仪对血糖检测的比对研究 被引量:20
15
作者 陈娟 颜巍 +1 位作者 周竞 王书侠 《检验医学与临床》 CAS 2019年第2期171-173,共3页
目的分析POCT血糖仪与生化分析仪对血糖检测结果,探讨POCT血糖仪检测糖尿病的临床应用价值。方法选取2016年11月至2017年11月该院100例患者,同时采用生化分析仪和2台不同型号的POCT血糖仪检测患者血糖,比较2种仪器的检测结果及相关性。... 目的分析POCT血糖仪与生化分析仪对血糖检测结果,探讨POCT血糖仪检测糖尿病的临床应用价值。方法选取2016年11月至2017年11月该院100例患者,同时采用生化分析仪和2台不同型号的POCT血糖仪检测患者血糖,比较2种仪器的检测结果及相关性。结果 2台POCT血糖仪均达到国家标准和ISO15197:2013版标准,总符合率均大于95%。配对t检验显示2种型号的POCT血糖仪与生化分析仪的检测结果比较,差异均无统计学意义(P>0.05),且相关系数均大于0.98,表明相关性良好。结论 2种型号的POCT血糖仪与生化分析仪相关性良好,但POCT血糖仪操作更简便、迅速。 展开更多
关键词 poct血糖仪 生化分析仪 血糖检测
下载PDF
芯片实验室技术在POCT上的最新进展 被引量:5
16
作者 陈宇 靖向盟 +2 位作者 朱军 陈翔 陈迪 《微纳电子技术》 CAS 2007年第12期1036-1042,1047,共8页
芯片实验室在临床诊断,特别是在床边诊断(POCT)检验领域具有重要作用。介绍了芯片实验室技术在POCT领域,尤其是近两年来在核酸、蛋白质及细胞检测等方面的最新研究进展,以及纳米技术和传统技术如免疫层析试纸条技术融合后,芯片实验室在P... 芯片实验室在临床诊断,特别是在床边诊断(POCT)检验领域具有重要作用。介绍了芯片实验室技术在POCT领域,尤其是近两年来在核酸、蛋白质及细胞检测等方面的最新研究进展,以及纳米技术和传统技术如免疫层析试纸条技术融合后,芯片实验室在POCT领域所显示出的优势。对芯片实验室技术未来在POCT领域的发展方向进行了讨论。 展开更多
关键词 床边诊断 芯片实验室 细胞 无线网络
下载PDF
25台POCT血糖仪与全自动生化分析仪血糖测定结果比对分析 被引量:10
17
作者 洪燕英 朱旭斌 秦杰 《中国卫生检验杂志》 CAS 2008年第12期2629-2631,共3页
目的:定期监测全院25台床旁检验血糖仪(以下简称POCT血糖仪)检测结果与贝克曼生化分析仪血糖测定结果的一致性,全面了解医院各病区血糖测定值之间的差异。方法:挑选10位空腹血糖在3.34~23.4 mmol/L(生化分析仪血糖检测结果)的患... 目的:定期监测全院25台床旁检验血糖仪(以下简称POCT血糖仪)检测结果与贝克曼生化分析仪血糖测定结果的一致性,全面了解医院各病区血糖测定值之间的差异。方法:挑选10位空腹血糖在3.34~23.4 mmol/L(生化分析仪血糖检测结果)的患者,分别抽取EDTA抗凝全血和未抗凝血。EDTA抗凝血在POCT血糖仪测定血糖;不抗凝血在贝克曼DXC800生化分析仪测定血清葡萄糖,每份样本测定3次,取均值。经比对,21台POCT血糖仪与生化分析仪测定值偏倚〈20%。对21台仪器按使用年限编号排序,按规则抽样5台,用卫生部POCT血糖室间质评物测定血糖,与卫生部临床检验中心室间质评回报结果的靶值比对,计算偏倚。结果:POCT血糖仪测定结果与生化分析仪测定结果比对,21台偏倚在1.1%~13.1%范围,4台仪器分别有3-4个浓度的测定值偏倚〉20%(偏倚b ias22%~25%)。21台POCT血糖仪测定值变异系数(CV%)为3.4%~8.5%。抽样的5台POCT血糖仪与卫生部临床检验中心POCT血糖室间质评靶值(以下简称"靶值")的偏倚为0~11.4%。结论:25台POCT血糖仪中21台与生化分析仪血糖检测结果比对具有一致性,4台比对差异大。生化分析仪比POCT血糖仪检测结果偏高约7.2%-13.1%。抽样的5台POCT血糖仪与靶值之间的偏倚符合卫生部临床检验中心质评判定标准。 展开更多
关键词 床旁检验 血糖 偏倚
下载PDF
神奇“魔法条”之新冠病毒的快速检测
18
作者 杨迪 魏嘉怡 +4 位作者 翟红 王昕 孙太明 宋浩乐 王海雁 《大学化学》 CAS 2024年第4期373-381,共9页
胶体金作为商业化的即时检验POCT(point-of-care test)免疫层析技术中最广泛的标记物之一,具有显著的颜色特征,后期无需可视化改造,且形态稳定、环境友好。本文试纸条制作过程简单,不需要大型贵重仪器。采用柠檬酸三钠还原氯金酸制备胶... 胶体金作为商业化的即时检验POCT(point-of-care test)免疫层析技术中最广泛的标记物之一,具有显著的颜色特征,后期无需可视化改造,且形态稳定、环境友好。本文试纸条制作过程简单,不需要大型贵重仪器。采用柠檬酸三钠还原氯金酸制备胶体金,将胶体金标记在新冠病毒的核衣壳N蛋白抗体上,通过在免疫层析试纸条可视区形成类似三明治结构的抗体-抗原-抗体夹心复合物,并以此复合物的红色检测线作为新冠病毒的定性分析依据。该检测方法裸眼可测、操作简单、且快速(10 min)、灵敏(检测限为0.5 ng∙mL^(−1))、低成本(每条不超过5元)。实验过程可以引导学生体验生命体系中抗原抗体相互作用引发的特异性生命化学反应,激发学生对化学、生物、生命科学和纳米材料等学科相互融合的可视化快检技术的浓厚研究兴趣。 展开更多
关键词 胶体金 poct 免疫层析 新冠病毒
下载PDF
POCT质量管理体系建设方案与成效分析 被引量:2
19
作者 郗晓婧 钟华 杨圆圆 《中国卫生质量管理》 2021年第7期29-32,共4页
针对POCT质量管理系统缺陷问题,某三级医院建立了院内POCT质量管理体系,包括POCT管理架构、相关制度与流程、资质与授权、质量控制等方面。该体系专业性与科学管理并重,并借助信息化手段,实施完善的设备准入、结果报告与危急值管理。经... 针对POCT质量管理系统缺陷问题,某三级医院建立了院内POCT质量管理体系,包括POCT管理架构、相关制度与流程、资质与授权、质量控制等方面。该体系专业性与科学管理并重,并借助信息化手段,实施完善的设备准入、结果报告与危急值管理。经实施,达到了流程简化、节约成本、平衡安全与便利的效果。下一步将对多种POCT检测项目进行信息化管理。 展开更多
关键词 poct 即时检测 管理体系 信息化
下载PDF
两种POCT法测定血HCG的比对研究 被引量:1
20
作者 袁晓华 杨春菊 +1 位作者 胡惠萍 张伟 《海南医学》 CAS 2015年第22期3332-3334,共3页
目的分析金标斑点POCT法和免疫荧光POCT法检测血HCG的性能。方法将306例样本按照浓度从低到高分为6个组,第1组86例、第2组60例、第3组14例、第4组68例、第5组41例、第6组37例。用电化学发光法(ECLIA)、金标斑点POCT法、免疫荧光POCT... 目的分析金标斑点POCT法和免疫荧光POCT法检测血HCG的性能。方法将306例样本按照浓度从低到高分为6个组,第1组86例、第2组60例、第3组14例、第4组68例、第5组41例、第6组37例。用电化学发光法(ECLIA)、金标斑点POCT法、免疫荧光POCT法平行检测这6个组的血HCG浓度。以ECLIA法为标准对金标斑点POCT法和免疫荧光POCT法的结果进行配对资料的t检验。结果 (1)免疫荧光POCT法的比对:第1组样本,免疫荧光POCT法和ECLIA法的符合性好;2~5组样本,免疫荧光POCT法和ECLIA法的检测结果比较差异无统计学意义;第6组样本,免疫荧光POCT法和ECLIA法的检测结果的差异有统计学意义(P〈0.05)。(2)金标斑点POCT法的比对:1~2组样本,金标斑点POCT法和ECLIA法的符合性好;3~4组样本,金标斑点POCT法和ECLIA法的检测结果比较差异有统计学意义。结论免疫荧光POCT法能简便、快速、准确的检测血HCG的浓度,且检测的准确度比金标斑点POCT法好,检测的量程比金标斑点POCT法宽。免疫荧光POCT法更适合于目前各类医院血HCG的急诊检验。 展开更多
关键词 人绒毛膜促性腺激素 即时检验(poct) 免疫荧光干式定量法 电化学发光法(ECLIA)
下载PDF