期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Assessment of Different Instruments and Methods for Detecting Pollution Share Rate of Heavy Metals in Water Samples 被引量:1
1
作者 Wen CHEN Xiangjun WANG +5 位作者 Yang ZHAO Lixing SU Yuzhi HUANG Lanfa MO Zhe ZHANG Min OUYANG 《Agricultural Biotechnology》 CAS 2014年第2期54-57,共4页
[ Objective ] This study aimed to investigate the impacts of different instruments and methods on detection of water samples and evaluate the detection results and pollution share rate. [ Method] Concentrations of six... [ Objective ] This study aimed to investigate the impacts of different instruments and methods on detection of water samples and evaluate the detection results and pollution share rate. [ Method] Concentrations of six heavy metals in three surface water samples and three underground water samples were detected by AAS and ICP-AES to analyze the differences in detection results and calculate the pollution share rate of heavy metals. [Result] As a result, the pollution share rate of six heavy metals varied significantly. Calculation results of comprehensive pollution share rate based on the lower pollution index of the same heavy metal in the same water sample detected by two methods were different from the results using either method. Due to different detection limits of instruments, detection results of heavy metals in the same water sample were different, which affected the accuracy of environmental quality assessment. [ Conclusion ] The detected pollution share rate varies with different detection limits. Therefore, instruments and methods with lower detection limit should be used. To be specific, AAS is suitable for detection of Pb and Cd, while ICP is suitable for detection of Cu, Zn, Fe and Mn. 展开更多
关键词 AAS ICP Detection limit pollution share rate
下载PDF
Application of subsurface wastewater infiltration system to on-site treatment of domestic sewage under high hydraulic loading rate 被引量:7
2
作者 Ying-hua Li Hai-bo Li +2 位作者 Xin-yang Xu Xuan Gong Yong-chun Zhou 《Water Science and Engineering》 EI CAS CSCD 2015年第1期49-54,共6页
In order to enhance the hydraulic loading rate (HLR) of a subsurface wastewater infiltration system (SWIS) used in treating domestic sewage, the intermittent operation mode was employed in the SWIS. The results sh... In order to enhance the hydraulic loading rate (HLR) of a subsurface wastewater infiltration system (SWIS) used in treating domestic sewage, the intermittent operation mode was employed in the SWIS. The results show that the intermittent operation mode contributes to the improvement of the HLR and the pollutant removal rate. When the wetting-drying ratio (RwD) was 1.0, the pollutant removal rate increased by (13.6 ± 0.3)% for NH3-N, (20.7 ± 1.1)% for TN, (18.6± 0.4)% for TP, (12.2 ± 0.5)% for BOD, (10.1 ± 0.3)% for COD, and (36.2 ± 1.2)% for SS, compared with pollutant removal rates under the continuous operation mode. The pollutant removal rate declined with the increase of the HLR. The effluent quality met The Reuse of Urban Recycling Water - Water Quality Standard for Scenic Environment Use (GB/T 18921-2002) even when the HLR was as high as 10 cm/d. Hydraulic conductivity, oxidation reduction potential (ORP), the quantity of nitrifying bacteria, and the pollutant removal rate of NH3-N increased with the decrease of the RWD. For the pollutant removal rates of TP, BOD, and COD, there were no significant difference (p 〈 0.05) under different RwDS. The suggested RWD was 1.0. Relative contribution of the pretreatment and SWlS to the pollutant removal was examined, and more than 80% removal of NH3-N, TN, TP, COD, and BOD occurred in the SWIS. 展开更多
关键词 Domestic sewage Subsurface wastewater infiltration system Intermittent operation mode Hydraulic loading rate Pollutant removal rate
下载PDF
Agricultural Non-point Source Pollution in Drinking Water Conservation Area of the Hongfeng Lake in Guiyang City 被引量:1
3
作者 YANG Tongquan LIU Hongyan +3 位作者 YU Yanghua CHEN Zhu RAO Cheng JIANG Chang 《Journal of Landscape Research》 2016年第5期100-104,共5页
On the basis of investigating rural population, land types, livestock and poultry breeding scale in drinking water conservation area of the Hongfeng Lake in Guiyang City, as well as the urban domestic pol utant discha... On the basis of investigating rural population, land types, livestock and poultry breeding scale in drinking water conservation area of the Hongfeng Lake in Guiyang City, as well as the urban domestic pol utant discharge coefficient, livestock and poultry excretion coefficient, nitrogen fertilizer and phosphate fertilizer loss rate in the first national pollution source survey, this paper tried to explore current situation of agricultural non-point source pollution, and provide scientific support for the pollution control. The results showed that in the drinking water conservation area of the Hongfeng lake in 2013, contribution rate of pollution sources to the water pollution in the Hongfeng Lake followed the sequence "livestock and poultry breeding > rural life > farmland fertilizer". Among all agricultural non-point source pollutants, livestock and poultry breeding pollutants were major pollution sources, with a contribution rate to CODCr, TP and NH3-N in water above 50%; rural domestic pollutants were also important pollution sources, its contribution rate to CODCr and NH3-N was 43.49% and 46.69%, respectively; contribution rate of farmland fertilizer pollutants to TN and TP was 33.76% and 27.71%, respectively, higher than that of rural domestic pollutants(25.87% and 6.75%). Therefore, the control of non-point source pollution within the drinking water conservation area should be enhanced, so as to control the pollution from the source. 展开更多
关键词 The Hongfeng Lake Agricultural non-point source pollution Pollutant contribution rate Control measures
下载PDF
Coupling of the flow field and the purification efficiency in root system region of ecological floating bed under different hydrodynamic conditions 被引量:7
4
作者 饶磊 王沛芳 +1 位作者 雷阳 王超 《Journal of Hydrodynamics》 SCIE EI CSCD 2016年第6期1049-1057,共9页
The artificial ecological floating bed is a commonly adopted in situ treatment technique for repairing and purifying polluted water. The plant root system of the floating bed is the primary region to absorb and degrad... The artificial ecological floating bed is a commonly adopted in situ treatment technique for repairing and purifying polluted water. The plant root system of the floating bed is the primary region to absorb and degrade the pollutant of water. Its inner flow field characteristics and the interactive water quantity with the surrounding water greatly impact the purification efficiency of the floating bed. In this paper, the particle image velocimetry (PIV) technology and the boundary velocity direct extraction method are used to study the velocity distribution of the root system region by numerical simulations and experiments in an experimental water channel. A pollution removal rate (PRR) evaluation model is built to calculate the PRR by coupling with the flow velocity field of the root system region. The variations of the total pollutant removal rate (TPRR) are discussed for different center distances (L =0.30 m, 0.45 m, 0.60 m), flow velocities (v= 0.007 m/s, 0.015 m/s, 0.025 m/s, 0.040 m/s, 0.055 m/s, 0.070 m/s) and root system porosities (P = 54.73%, 68.33%, 79.17%). The results indicate that the position arrangement of the floating beds influences the TPRR significantly, and the distance should be limited in a reasonable range for a high purification efficiency. Moreover, the root systems with higher porosity (P = 68.33%, 79.17%) have higher TPRR value than a lower porosity root system (P = 54.73%) within a certain flow velocity range, and the higher porosity root system has less fluctuation of the TPRR value than a lower porosity situation within a wide flow velocity range. Furthermore, under the same center distance condition, the lower flow velocity condition brings about a significantly higher TPRR value than the higher flow velocity situation. 展开更多
关键词 ecological floating bed root system region flow velocity pollutant removal rate PIV
原文传递
The coupling between hydrodynamic and purification efficiencies of ecological porous spur-dike in field drainage ditch 被引量:3
5
作者 饶磊 王沛芳 +1 位作者 戴青松 王超 《Journal of Hydrodynamics》 SCIE EI CSCD 2018年第3期373-383,共11页
In this study, a series of ecological porous spur-dikes are arranged in an experiment channel to simulate a real field drainage ditch. The inside and outside flow fields of spur-dikes are determined by numerical simul... In this study, a series of ecological porous spur-dikes are arranged in an experiment channel to simulate a real field drainage ditch. The inside and outside flow fields of spur-dikes are determined by numerical simulations and experimental methods. An Ammonia-Nitrogen(NH3-N) degradation evaluation model is built to calculate the pollution removal rate by coupling with the inner flow field of the porous spur-dikes. The variations of the total pollutant removal rate in the channel are discussed in terms of different porosities and gap distances between spur-dikes and inlet flow velocities. It is indicated that a reasonable parameter matching of the porosity and the gap distance with the flow velocity of the ditch can bring about a satisfactory purification efficiency with a small delivery quantity of ecological porous materials. 展开更多
关键词 Porous water permeable material ecological spur-dike field drainage ditch pollutant removal rate COUPLING
原文传递
Evaluation of the effectiveness of horizontal subsurface flow constructed wetlands for different media 被引量:2
6
作者 Antonio Albuquerque José Oliveira +1 位作者 Sabrina Semitela Leonor Amaral 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2010年第6期820-825,共6页
Two media bed (gravel and Filtralite NR) were tested in a mesocosm to evaluate the removal of organic matter (as chemical oxygen demand (COD)), ammonia (NH4-N), nitrite, nitrate and solid matter (as total sus... Two media bed (gravel and Filtralite NR) were tested in a mesocosm to evaluate the removal of organic matter (as chemical oxygen demand (COD)), ammonia (NH4-N), nitrite, nitrate and solid matter (as total suspended solids (TSS)) for a synthetic wastewater (acetate-based) and a domestic wastewater. The use of Filtralite allowed average removal rates (6--16.8 g COD/(m^2·day), 0.8-1.1 g NH4-N/(m^2·day) and 3.1 g TSS/(m^2·day)) and removal efficiencies (65%-93%, 57%-85% and 78% for COD, NH4-N and TSS, respectively), higher than that observed in the experiments with gravel. The applied loads of COD, ammonia, nitrate and TSS seem to influence the respective removal rates but only for the treatment of domestic wastewater with nigher correlation coefficients for Filtralite. Regardless the type of media bed and the type of wastewater, nitrate was completely removed for nitrogen loading rates up to 1.3 g NO3-N/(m^2·day). There was no evidence of the influence of nitrate loads on the removal of organic matter. 展开更多
关键词 media bed constructed wetlands pollutants removal rates
原文传递
Historical trends in the anthropogenic heavy metal levels in the tidal flat sediments of Lianyungang, China 被引量:5
7
作者 Rui Zhang Fan Zhang +3 位作者 Yingjun Ding Jinrong Gao Jing Chen Li Zhou 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2013年第7期1458-1468,共11页
The sedimentation of metals can preserve the historical record of contaminant input from local and regional sources and provide information on the historical changes in regionalwater and sediment quality. We report th... The sedimentation of metals can preserve the historical record of contaminant input from local and regional sources and provide information on the historical changes in regionalwater and sediment quality. We report the 210Pb activities and the heavy metal (Cd, Cr, Cu, Mn, Pb and Zn)depth profiles from sediment cores retrieved in 2010. The mean sedimentation rates of 0.85-1.5 cm/yr aredetermined by 210 Pbdating. The sediments in the tidal flat have recorded heavy metaldeposition and thus allow the establishment of a connection between the temporal evolution of the heavy metal pollution and the historical changes in the economicdevelopment of Lianyungang. The enrichment factors (EF) are calculated to estimate the level of contamination stored in these sediments. The results show that in the studied sites, Cr and Cudisplay low EF values and are mainly from lithogenic origin. For the other studied trace metals, a great variability in the sedimentary record is observed. Significant anthropogenic enrichment over the last 50 years is revealed at the tidal flat that receives fluvial inputs. Zinc is the elementwith the highest EF values, followed by the order of Pb 〉 Cd 〉 Mn 〉 Cu and Cr. The temporal variations of the heavy metals peakduring the late 1980s to the early2000s and show adecreasing trend afterward. The pollution intensity of the tidal flat isdetermined by using EF and thegeo-accumulation index (Igeo ),which show that, based on the Igeo scale, the tidal flat of Haizhou Bay is unpolluted to moderately polluted. 展开更多
关键词 sediment rates heavy metals pollution anthropogenic input tidal flat
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部