A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glip...A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glipizide as internal standard(IS). After simplified protein precipitation with methanol, both the analytes and IS were chromatographed on a Zorbax CN column via gradient elution with methanol(containing 5 mmol/L ammonium ace- tate) and 5 mmol/L aqueous ammonium acetate as the mobile phase. Detection was performed by multiple reaction monitoring(MRM) scanning via ESI source operated in positive ionization mode. Specificity, linearity, accuracy, pre- cision, recovery, matrix effect and stability were validated for metformin and glimepiride in beagle dog plasma. The calibration curves were linear in a concentration range of 10-10000 ng/mL for metformin and 4-4000 ng/mL for glimepiride with both correlation coefficients higher than 0.99. The recoveries obtained for the analytes and IS were all between 82.7% and 101.2%. The method exhibited excellent performance in terms of selectivity, robustness, short analytical time and simplicity of sample preparation. Finally, the proposed method was applied to a bioequivalence study of self-made bilayer tablet and commercial formulation containing 500 mg of metformin and 1 mg of glimepi- ride in beagle dogs.展开更多
A rapid and sensitive liquid chromatography tandem mass spectrometry(LC-MS/MS) method has been developed and validated for the determination of moxifloxacin(MOXI) in human plasma. After a simple protein precipitation ...A rapid and sensitive liquid chromatography tandem mass spectrometry(LC-MS/MS) method has been developed and validated for the determination of moxifloxacin(MOXI) in human plasma. After a simple protein precipitation using acetonitrile, the post treatment samples were analysed on a C18 column interfaced with a Triple Quadropole Tandem Mass Spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of 0.1% formic acid–acetonitrile(60:40, v/v). Ciprofloxacin(CIPRO) was used as an internal standard. The analyte and internal standard(CIPRO) were monitored in the multiple reaction monitoring mode(MRM). The mass transition ion-pair has been followed as m/z 402→358.2 for MOXI and 332→288.1 for CIPRO. The method was linear in the concentration range of 25–5000 ng/mL. The lower limit of quantification was 25 ng/mL. The intra- and inter-day precision(relative standard deviation) and accuracy(relative error) values were within 12.4%. Each plasma sample was analyzed within 3 min.展开更多
通过固相萃取富集伏马菌素,采用液相色谱-电喷雾串联质谱法测定玉米和芦笋中的伏马菌素B1(FB1)、伏马菌素B2(FB2).在最佳色谱条件下,伏马菌素B1、伏马菌素B2的保留时间分别为5.2 min 和8.8 min,样品空白无干扰.离子化技术采用电喷雾正...通过固相萃取富集伏马菌素,采用液相色谱-电喷雾串联质谱法测定玉米和芦笋中的伏马菌素B1(FB1)、伏马菌素B2(FB2).在最佳色谱条件下,伏马菌素B1、伏马菌素B2的保留时间分别为5.2 min 和8.8 min,样品空白无干扰.离子化技术采用电喷雾正离子方式,以多反应监测(MRM)方式进行检测.该法检出限为80 pg;线性定量范围为0.01~10mg/L;回收率为78.3%~104.9%;相对标准偏差为2.2%~14.2%.利用ESI/MS/MS对伏马菌素B1、伏马菌素B2进行了质谱解析,分别选择特征离子峰m/z 352、528和m/z 336、512作为伏马菌素B1、伏马菌素B2准确定性的依据.方法灵敏度高,选择性好,准确度高,可为食品中伏马菌素的风险评估提供灵敏、准确的分析方法.展开更多
建立了纺织品中7种苯氧羧酸类除草剂的高效液相色谱-电喷雾串联质谱(LC-ESI-MS/MS)快速检测方法。样品经甲酸酸化的丙酮溶液超声提取两次,无需其它净化过程。液相色谱使用C18反相色谱柱,流动相为醋酸铵水溶液和甲醇,在梯度条件下分析。...建立了纺织品中7种苯氧羧酸类除草剂的高效液相色谱-电喷雾串联质谱(LC-ESI-MS/MS)快速检测方法。样品经甲酸酸化的丙酮溶液超声提取两次,无需其它净化过程。液相色谱使用C18反相色谱柱,流动相为醋酸铵水溶液和甲醇,在梯度条件下分析。在选择反应检测(SRM)负离子模式下进行质谱信号采集,采用两对同位素离子对进行定性和定量分析。选取3种有代表性的纺织品进行方法检出限(LOD)、定量限(LOQ)、线性、回收率和精密度的验证。方法的LOQ为0.9~2.4μg/kg;回收率为85%~106%;相对标准偏差为2%~11%。本方法简便、有效、可靠、灵敏,能够满足国际生态纺织品标准(Oeko-Tex Standard 100)的限量要求,适用于纺织品中苯氧羧酸类除草剂的日常检测及确证。展开更多
文摘A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glipizide as internal standard(IS). After simplified protein precipitation with methanol, both the analytes and IS were chromatographed on a Zorbax CN column via gradient elution with methanol(containing 5 mmol/L ammonium ace- tate) and 5 mmol/L aqueous ammonium acetate as the mobile phase. Detection was performed by multiple reaction monitoring(MRM) scanning via ESI source operated in positive ionization mode. Specificity, linearity, accuracy, pre- cision, recovery, matrix effect and stability were validated for metformin and glimepiride in beagle dog plasma. The calibration curves were linear in a concentration range of 10-10000 ng/mL for metformin and 4-4000 ng/mL for glimepiride with both correlation coefficients higher than 0.99. The recoveries obtained for the analytes and IS were all between 82.7% and 101.2%. The method exhibited excellent performance in terms of selectivity, robustness, short analytical time and simplicity of sample preparation. Finally, the proposed method was applied to a bioequivalence study of self-made bilayer tablet and commercial formulation containing 500 mg of metformin and 1 mg of glimepi- ride in beagle dogs.
文摘A rapid and sensitive liquid chromatography tandem mass spectrometry(LC-MS/MS) method has been developed and validated for the determination of moxifloxacin(MOXI) in human plasma. After a simple protein precipitation using acetonitrile, the post treatment samples were analysed on a C18 column interfaced with a Triple Quadropole Tandem Mass Spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of 0.1% formic acid–acetonitrile(60:40, v/v). Ciprofloxacin(CIPRO) was used as an internal standard. The analyte and internal standard(CIPRO) were monitored in the multiple reaction monitoring mode(MRM). The mass transition ion-pair has been followed as m/z 402→358.2 for MOXI and 332→288.1 for CIPRO. The method was linear in the concentration range of 25–5000 ng/mL. The lower limit of quantification was 25 ng/mL. The intra- and inter-day precision(relative standard deviation) and accuracy(relative error) values were within 12.4%. Each plasma sample was analyzed within 3 min.
文摘建立了纺织品中7种苯氧羧酸类除草剂的高效液相色谱-电喷雾串联质谱(LC-ESI-MS/MS)快速检测方法。样品经甲酸酸化的丙酮溶液超声提取两次,无需其它净化过程。液相色谱使用C18反相色谱柱,流动相为醋酸铵水溶液和甲醇,在梯度条件下分析。在选择反应检测(SRM)负离子模式下进行质谱信号采集,采用两对同位素离子对进行定性和定量分析。选取3种有代表性的纺织品进行方法检出限(LOD)、定量限(LOQ)、线性、回收率和精密度的验证。方法的LOQ为0.9~2.4μg/kg;回收率为85%~106%;相对标准偏差为2%~11%。本方法简便、有效、可靠、灵敏,能够满足国际生态纺织品标准(Oeko-Tex Standard 100)的限量要求,适用于纺织品中苯氧羧酸类除草剂的日常检测及确证。
文摘建立了高效液相色谱-电喷雾串联质谱(HPLC-ESI MS/MS)分析环境水样中22种抗生素类药物的方法。采用HLB固相萃取柱对环境水样中的目标化合物进行富集、净化,然后以6mL氨水-甲醇(5∶95,v/v)溶液洗脱。收集的洗脱液经氮气吹干至1mL,然后进行HPLC-ESI MS/MS分离分析。色谱流动相A相为甲醇-乙腈(1∶1,v/v),B相为0.3%(体积分数)甲酸水溶液(含0.1%(体积分数)甲酸铵,pH2.9);色谱柱为XTerra MS C18柱。质谱检测采用正离子扫描,多反应监测模式。分别以自来水和污水作为基质,22种抗生素类药物的加标平均回收率分别为54.9%~130%和57.4%~138%,相对标准偏差(n=3)分别为2.85%~28.6%和2.02%~23.2%;方法的检出限为0.05~0.5ng/L。将建立的方法应用于北京市高碑店湖和小清河水样的分析,结果表明在两个水样中均有部分抗生素类药物检出。