INTRODUCTIONMore than 10 years ago ,an interventional technique for the creation of an intrahepatic decompressive shunt between a branch of the portal vein and a main hepatic vein using expandable metallic stents has ...INTRODUCTIONMore than 10 years ago ,an interventional technique for the creation of an intrahepatic decompressive shunt between a branch of the portal vein and a main hepatic vein using expandable metallic stents has been intriduced for the treatmint of portal hypertension[1,2],This transjugular portosystemic intrahepatic stent shunt (TIPS) functions as a side to side shunt ,similarly to surgical shunts .展开更多
AIM: To evaluate a new balloon-expandable stainless steel stent (Cordis stent) in a transjugular intrahepatic portosystemic shunt (TIPS) porcine model and compared with Wallstent. METHODS: TIPS was performed in 26 nor...AIM: To evaluate a new balloon-expandable stainless steel stent (Cordis stent) in a transjugular intrahepatic portosystemic shunt (TIPS) porcine model and compared with Wallstent. METHODS: TIPS was performed in 26 normal domestic pigs weighing 20 kg-30 kg using a Cordis stent or Wallstent (13 pigs in each stent). All pigs were sacrificed at the 14th day after TIPS. The stent deployment delivery system, stent patency, and stent recoil after placement were evaluated.Proliferative response in representative histological sections from the center,hepatic and portal regions of the two stent designs were quantified. RESULTS: The shunt was widely patent in 4 pigs in the Cordis stent group (4/12, premature dead in 1 pig), and in 5 pigs in the Wallstent group (5/13). All remaining stents of both designs were occluded or stenotic. The mean quantified proliferation including thickness of the proliferation and the ratio of proliferation: total area in three assayed regions in Cordis stent and Wallstent was 2.18 mm:2.00 mm, and 59.18 mm2:51.66 mm2, respectively (P 】 0.05). The delivery system and mechanical properties of the Cordis stent functioned well. CONCLUSION: The new Cordis stent is appropriate for TIPS procedure.展开更多
Purpose:We aimed to compare treatment efficacy,safety and material cost between tissue gel and coil regarding variceal embolization during transjugular intrahepatic portosystemic shunt(TIPS).Materials&Methods:This...Purpose:We aimed to compare treatment efficacy,safety and material cost between tissue gel and coil regarding variceal embolization during transjugular intrahepatic portosystemic shunt(TIPS).Materials&Methods:This retrospective study including cirrhotic patients with variceal bleeding treated with TIPS combined with variceal embolization between January 2016 and August 2017.Patients were divided into three groups according to embolic agents used in variceal embolization:tissue gel group(Group A),combination group(Group B),and coil group(Group C).The primary endpoint was 1-year rebleeding rate after TIPS creation.The secondary endpoints included shunt dysfunction,overt hepatic encephalopathy,liver function,and embolic agents-related expense.Results:A total of 60 patients(30,10,and 20 in Group A,B,and C)were included.Variceal rebleeding occurred in3(10%),0(0%),and 4(20%)patients within one year after TIPS creation in Group A,B,and C,respectively.Stent dysfunction occurred in 2(3.3%)patients and 9(15.0%)patients experienced overt hepatic encephalopathy.No significant differences were observed between three groups regarding primary and secondary endpoints except embolic agents-related expense,with a significantly lower cost in Group A when compared to the other two groups.Stent dysfunction occurred in two patients,with one patient in Group A developed acute occlusion caused by thrombus and another patient in Group C underwent stent stenosis during follow-up.Conclusions:Compares to coil alone or combines with coil,tissue gel has similar treatment efficacy and safety,but with significantly lower cost for variceal bleeding during TIPS.展开更多
Patients with decompensated hepatic cirrhosis may present systemic alterations and dysfunction of multiple organs. Ascites, portal hypertension, esophageal varices, and hepatic encephalopathy are common complications ...Patients with decompensated hepatic cirrhosis may present systemic alterations and dysfunction of multiple organs. Ascites, portal hypertension, esophageal varices, and hepatic encephalopathy are common complications arising from cirrhosis. The aim of this paper is to report a case of a patient with liver cirrhosis and the complications of a transjugular intrahepatic portosystemic shunt.</span><b> </b><span style="font-family:Verdana;">Male, elderly, and ex-alcoholic, diagnosed with liver cirrho</span><span style="font-family:Verdana;">sis, ascites, and esophageal varices. He underwent transjugular intrahepatic portosystemic shunt due to portal hypertension and returned to the hospital</span> <span style="font-family:Verdana;">after 24 hours with agitation and mental confusion. He had a bowel move</span><span style="font-family:Verdana;">ment stop, neurological worsening, loss of renal function, hepatic hydrothorax, hepatic encephalopathy, hypernatremia, hypocalcemia, and hypophosphatemia. He underwent a new procedure to occlude the transjugular intrahepatic portosystemic shunt, showing improvement of the mental status and ascites. However, continued with decompensation and hydro-electrolytic disorders. He evolved with worsening of the ventilatory pattern, and neurological and renal function, with a fatal outcome.</span><b> </b><span style="font-family:Verdana;">Esophageal varices due to portal hypertension can be corrected with the transjugular intrahepatic portosystemic shunt. However, complications such as hypernatremia, hepatic hydrothorax, and hepatic encephalopathy may occur. Therefore, there is a need for reintervention to shunt or reduce its caliber. Thus, for patients with advanced age and decompensated cirrhosis, the potential risks and benefits of this procedure should be carefully evaluated due to the risk of complications and death.展开更多
Cirrhotic patients with recurrent variceal bleeds who have failed prior medical and endoscopic therapies and are not transjugular intrahepatic portosystemic shunt candidates face a grim prognosis with limited options....Cirrhotic patients with recurrent variceal bleeds who have failed prior medical and endoscopic therapies and are not transjugular intrahepatic portosystemic shunt candidates face a grim prognosis with limited options. We propose that mesocaval shunting be offered to this group of patients as it has the potential to decrease portal pressures and thus decrease the risk of recurrent variceal bleeding. Mesocaval shunts are stent grafts placed by interventional radiologists between the mesenteric system, most often the superior mesenteric vein, and the inferior vena cava. This allows flow to bypass the congested hepatic system, reducing portal pressures. This technique avoids the general anesthesia and morbidity associated with surgical shunt placement and has been successful in several case reports. In this paper we review the technique, candidate selection, potential pitfalls and benefits of mesocaval shunt placement.展开更多
文摘INTRODUCTIONMore than 10 years ago ,an interventional technique for the creation of an intrahepatic decompressive shunt between a branch of the portal vein and a main hepatic vein using expandable metallic stents has been intriduced for the treatmint of portal hypertension[1,2],This transjugular portosystemic intrahepatic stent shunt (TIPS) functions as a side to side shunt ,similarly to surgical shunts .
文摘AIM: To evaluate a new balloon-expandable stainless steel stent (Cordis stent) in a transjugular intrahepatic portosystemic shunt (TIPS) porcine model and compared with Wallstent. METHODS: TIPS was performed in 26 normal domestic pigs weighing 20 kg-30 kg using a Cordis stent or Wallstent (13 pigs in each stent). All pigs were sacrificed at the 14th day after TIPS. The stent deployment delivery system, stent patency, and stent recoil after placement were evaluated.Proliferative response in representative histological sections from the center,hepatic and portal regions of the two stent designs were quantified. RESULTS: The shunt was widely patent in 4 pigs in the Cordis stent group (4/12, premature dead in 1 pig), and in 5 pigs in the Wallstent group (5/13). All remaining stents of both designs were occluded or stenotic. The mean quantified proliferation including thickness of the proliferation and the ratio of proliferation: total area in three assayed regions in Cordis stent and Wallstent was 2.18 mm:2.00 mm, and 59.18 mm2:51.66 mm2, respectively (P 】 0.05). The delivery system and mechanical properties of the Cordis stent functioned well. CONCLUSION: The new Cordis stent is appropriate for TIPS procedure.
基金funded by the Jiangsu Provincial Medical Talent Funding(ZDRCA2016038)the Suzhou Special Diagnosis and Treatment Technology of Clinical Key Diseases(LCZX201704)+2 种基金the National Natural Science Foundation of China(81771945,81901847)the Natural Science Foundation of Jiangsu Province(BK20190177)the Suzhou Science and Technology Youth Plan(KJXW2018003).
文摘Purpose:We aimed to compare treatment efficacy,safety and material cost between tissue gel and coil regarding variceal embolization during transjugular intrahepatic portosystemic shunt(TIPS).Materials&Methods:This retrospective study including cirrhotic patients with variceal bleeding treated with TIPS combined with variceal embolization between January 2016 and August 2017.Patients were divided into three groups according to embolic agents used in variceal embolization:tissue gel group(Group A),combination group(Group B),and coil group(Group C).The primary endpoint was 1-year rebleeding rate after TIPS creation.The secondary endpoints included shunt dysfunction,overt hepatic encephalopathy,liver function,and embolic agents-related expense.Results:A total of 60 patients(30,10,and 20 in Group A,B,and C)were included.Variceal rebleeding occurred in3(10%),0(0%),and 4(20%)patients within one year after TIPS creation in Group A,B,and C,respectively.Stent dysfunction occurred in 2(3.3%)patients and 9(15.0%)patients experienced overt hepatic encephalopathy.No significant differences were observed between three groups regarding primary and secondary endpoints except embolic agents-related expense,with a significantly lower cost in Group A when compared to the other two groups.Stent dysfunction occurred in two patients,with one patient in Group A developed acute occlusion caused by thrombus and another patient in Group C underwent stent stenosis during follow-up.Conclusions:Compares to coil alone or combines with coil,tissue gel has similar treatment efficacy and safety,but with significantly lower cost for variceal bleeding during TIPS.
文摘Patients with decompensated hepatic cirrhosis may present systemic alterations and dysfunction of multiple organs. Ascites, portal hypertension, esophageal varices, and hepatic encephalopathy are common complications arising from cirrhosis. The aim of this paper is to report a case of a patient with liver cirrhosis and the complications of a transjugular intrahepatic portosystemic shunt.</span><b> </b><span style="font-family:Verdana;">Male, elderly, and ex-alcoholic, diagnosed with liver cirrho</span><span style="font-family:Verdana;">sis, ascites, and esophageal varices. He underwent transjugular intrahepatic portosystemic shunt due to portal hypertension and returned to the hospital</span> <span style="font-family:Verdana;">after 24 hours with agitation and mental confusion. He had a bowel move</span><span style="font-family:Verdana;">ment stop, neurological worsening, loss of renal function, hepatic hydrothorax, hepatic encephalopathy, hypernatremia, hypocalcemia, and hypophosphatemia. He underwent a new procedure to occlude the transjugular intrahepatic portosystemic shunt, showing improvement of the mental status and ascites. However, continued with decompensation and hydro-electrolytic disorders. He evolved with worsening of the ventilatory pattern, and neurological and renal function, with a fatal outcome.</span><b> </b><span style="font-family:Verdana;">Esophageal varices due to portal hypertension can be corrected with the transjugular intrahepatic portosystemic shunt. However, complications such as hypernatremia, hepatic hydrothorax, and hepatic encephalopathy may occur. Therefore, there is a need for reintervention to shunt or reduce its caliber. Thus, for patients with advanced age and decompensated cirrhosis, the potential risks and benefits of this procedure should be carefully evaluated due to the risk of complications and death.
文摘Cirrhotic patients with recurrent variceal bleeds who have failed prior medical and endoscopic therapies and are not transjugular intrahepatic portosystemic shunt candidates face a grim prognosis with limited options. We propose that mesocaval shunting be offered to this group of patients as it has the potential to decrease portal pressures and thus decrease the risk of recurrent variceal bleeding. Mesocaval shunts are stent grafts placed by interventional radiologists between the mesenteric system, most often the superior mesenteric vein, and the inferior vena cava. This allows flow to bypass the congested hepatic system, reducing portal pressures. This technique avoids the general anesthesia and morbidity associated with surgical shunt placement and has been successful in several case reports. In this paper we review the technique, candidate selection, potential pitfalls and benefits of mesocaval shunt placement.