Electrospray ionization mass spectrometry(ESI-MS) was applied simultaneously in determining norditerpenoid alkaloids from the roots of Aconitum sinomantanum Nakai (RAS) based on molecular mass information. The tan...Electrospray ionization mass spectrometry(ESI-MS) was applied simultaneously in determining norditerpenoid alkaloids from the roots of Aconitum sinomantanum Nakai (RAS) based on molecular mass information. The tandem mass spectra( ESI-MS^n) provided the alkaloidal structural information, through which the existence of these alkaloids was further confirmed. Accordingly, six known norditerpenoid alkaloids were simultaneously determined on the basis of their ESI-MS^n spectra. Furthermore, based on the diagnostic fragmentation pathways of alkaloidal MS^n, a rapid method for direct detection and characterization of alkaloids from an ethanolic extract of RAS was described.展开更多
A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glip...A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glipizide as internal standard(IS). After simplified protein precipitation with methanol, both the analytes and IS were chromatographed on a Zorbax CN column via gradient elution with methanol(containing 5 mmol/L ammonium ace- tate) and 5 mmol/L aqueous ammonium acetate as the mobile phase. Detection was performed by multiple reaction monitoring(MRM) scanning via ESI source operated in positive ionization mode. Specificity, linearity, accuracy, pre- cision, recovery, matrix effect and stability were validated for metformin and glimepiride in beagle dog plasma. The calibration curves were linear in a concentration range of 10-10000 ng/mL for metformin and 4-4000 ng/mL for glimepiride with both correlation coefficients higher than 0.99. The recoveries obtained for the analytes and IS were all between 82.7% and 101.2%. The method exhibited excellent performance in terms of selectivity, robustness, short analytical time and simplicity of sample preparation. Finally, the proposed method was applied to a bioequivalence study of self-made bilayer tablet and commercial formulation containing 500 mg of metformin and 1 mg of glimepi- ride in beagle dogs.展开更多
The sequence analysis of peptides was performed by nano-electrospray ionization Fourier transform ion cyclotron resonance tandem mass spectrometry(Nano-ESI-FT-ICR-MSn) and several peptides were chosen as examples. W...The sequence analysis of peptides was performed by nano-electrospray ionization Fourier transform ion cyclotron resonance tandem mass spectrometry(Nano-ESI-FT-ICR-MSn) and several peptides were chosen as examples. With the aid of the collision induced dissociation(CID), FT-ICR provides not only precise mass/charge ratio, but also structure information of the selected peptides. The fragment ions were identified according to the observed molecular weights and peptide sequence was determined successfully. So Nano-ESI-FT-ICR-MSn is a useful tool for identification of the amino acid sequence of peptides with high confidence. Besides, a pathway for the dehydration of y ions without amino acids containing carboxylic acid under sustained off-resonance irradiation collision-induced dissociation(SORI-CID) condition was proposed.展开更多
文摘Electrospray ionization mass spectrometry(ESI-MS) was applied simultaneously in determining norditerpenoid alkaloids from the roots of Aconitum sinomantanum Nakai (RAS) based on molecular mass information. The tandem mass spectra( ESI-MS^n) provided the alkaloidal structural information, through which the existence of these alkaloids was further confirmed. Accordingly, six known norditerpenoid alkaloids were simultaneously determined on the basis of their ESI-MS^n spectra. Furthermore, based on the diagnostic fragmentation pathways of alkaloidal MS^n, a rapid method for direct detection and characterization of alkaloids from an ethanolic extract of RAS was described.
文摘A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glipizide as internal standard(IS). After simplified protein precipitation with methanol, both the analytes and IS were chromatographed on a Zorbax CN column via gradient elution with methanol(containing 5 mmol/L ammonium ace- tate) and 5 mmol/L aqueous ammonium acetate as the mobile phase. Detection was performed by multiple reaction monitoring(MRM) scanning via ESI source operated in positive ionization mode. Specificity, linearity, accuracy, pre- cision, recovery, matrix effect and stability were validated for metformin and glimepiride in beagle dog plasma. The calibration curves were linear in a concentration range of 10-10000 ng/mL for metformin and 4-4000 ng/mL for glimepiride with both correlation coefficients higher than 0.99. The recoveries obtained for the analytes and IS were all between 82.7% and 101.2%. The method exhibited excellent performance in terms of selectivity, robustness, short analytical time and simplicity of sample preparation. Finally, the proposed method was applied to a bioequivalence study of self-made bilayer tablet and commercial formulation containing 500 mg of metformin and 1 mg of glimepi- ride in beagle dogs.
基金Supported by the National Natural Science Foundation of China(No.20675079)
文摘The sequence analysis of peptides was performed by nano-electrospray ionization Fourier transform ion cyclotron resonance tandem mass spectrometry(Nano-ESI-FT-ICR-MSn) and several peptides were chosen as examples. With the aid of the collision induced dissociation(CID), FT-ICR provides not only precise mass/charge ratio, but also structure information of the selected peptides. The fragment ions were identified according to the observed molecular weights and peptide sequence was determined successfully. So Nano-ESI-FT-ICR-MSn is a useful tool for identification of the amino acid sequence of peptides with high confidence. Besides, a pathway for the dehydration of y ions without amino acids containing carboxylic acid under sustained off-resonance irradiation collision-induced dissociation(SORI-CID) condition was proposed.