In order to minimize the harmonic distortion rate of the current at the common coupling point,this paper proposes a coordinated allocation strategy of harmonic compensation capacity considering the performance of acti...In order to minimize the harmonic distortion rate of the current at the common coupling point,this paper proposes a coordinated allocation strategy of harmonic compensation capacity considering the performance of active power filters(APF).On the premise of proportional distribution of harmonic compensation capacity,the harmonic compensation rate of each APF is considered,and the harmonic current value of each APF to be compensated is obtained.At the same time,the communication topology is introduced.Each APF takes into account the compensation ability of other APFs.Finally,three APFs with different capacity and performance are configured at the harmonic source to suppress the same harmonic source,and the harmonic distortion rate is reduced to 1.73%.The simulation results show that the strategy can effectively improve the compensation capability of the multiple APF cascaded system to the power grid without increasing the installed capacity.展开更多
Many industrial installations in developing countries start-up as small factories, without regard for the need of compensation of reactive power, leading to significant financial losses in the long term. By improving ...Many industrial installations in developing countries start-up as small factories, without regard for the need of compensation of reactive power, leading to significant financial losses in the long term. By improving the power factor, the customer can reduce its power demand and potentially increase efficiency of their equipment. A PIC microcontroller is used to switch capacitor banks to compensate for the reactive power. In order to determine the size of the capacitor bank needed, the microcontroller calculates the phase difference between the voltage and the current. The results obtained based on the lagging power factor for three test loads show an improvement in the power factor from 0.52 to 0.96 under different test load conditions.展开更多
The paper introduces one design idea that making use of SCM to control Real-timely the dynamic compensation of reactive power.Firstly,design one Circuit to Sample the voltage and current,and by these datas we can easi...The paper introduces one design idea that making use of SCM to control Real-timely the dynamic compensation of reactive power.Firstly,design one Circuit to Sample the voltage and current,and by these datas we can easily calculate the power factor,and Voltage controller in the microcontroller to determine whether input the compensation capacitance according to the size of power factor,the paper also analyzes the principle of capacitance compensation and calculation method. Dynamic compensation for the entire process is quick and accurate.展开更多
高压直挂电池储能系统(battery energy storage system,BESS)采用H桥电路串联的方法升高电压后接入电网,将电池簇分散接入级联H桥变换器的直流侧,具有高度模块化的结构,对比低压方案具有单机容量大、效率高、响应速度快等明显优势。高...高压直挂电池储能系统(battery energy storage system,BESS)采用H桥电路串联的方法升高电压后接入电网,将电池簇分散接入级联H桥变换器的直流侧,具有高度模块化的结构,对比低压方案具有单机容量大、效率高、响应速度快等明显优势。高压直挂BESS若能兼具无功补偿能力,实现系统四象限运行,将具有更大的成本优势和经济效益。电池簇接单相H桥变换器的结构,使得系统运行在高比例无功补偿工况时,电池簇电流在一个二倍基频的周期中会出现两次反向,导致电池运行在高频充放电的工况,这会对电池寿命和电池状态监测造成较大的影响。为解决这一问题,提出一种基于零序电压注入的高比例无功补偿控制方法,避免了二倍基频脉动电流对电池进行高频充放电,再通过优化零序电压的幅值和相位,最大程度上降低对电池的影响。展开更多
基金This work was supported in part by the National Natural Science Foundation of China(Grant No.61863023).
文摘In order to minimize the harmonic distortion rate of the current at the common coupling point,this paper proposes a coordinated allocation strategy of harmonic compensation capacity considering the performance of active power filters(APF).On the premise of proportional distribution of harmonic compensation capacity,the harmonic compensation rate of each APF is considered,and the harmonic current value of each APF to be compensated is obtained.At the same time,the communication topology is introduced.Each APF takes into account the compensation ability of other APFs.Finally,three APFs with different capacity and performance are configured at the harmonic source to suppress the same harmonic source,and the harmonic distortion rate is reduced to 1.73%.The simulation results show that the strategy can effectively improve the compensation capability of the multiple APF cascaded system to the power grid without increasing the installed capacity.
文摘Many industrial installations in developing countries start-up as small factories, without regard for the need of compensation of reactive power, leading to significant financial losses in the long term. By improving the power factor, the customer can reduce its power demand and potentially increase efficiency of their equipment. A PIC microcontroller is used to switch capacitor banks to compensate for the reactive power. In order to determine the size of the capacitor bank needed, the microcontroller calculates the phase difference between the voltage and the current. The results obtained based on the lagging power factor for three test loads show an improvement in the power factor from 0.52 to 0.96 under different test load conditions.
文摘The paper introduces one design idea that making use of SCM to control Real-timely the dynamic compensation of reactive power.Firstly,design one Circuit to Sample the voltage and current,and by these datas we can easily calculate the power factor,and Voltage controller in the microcontroller to determine whether input the compensation capacitance according to the size of power factor,the paper also analyzes the principle of capacitance compensation and calculation method. Dynamic compensation for the entire process is quick and accurate.
文摘高压直挂电池储能系统(battery energy storage system,BESS)采用H桥电路串联的方法升高电压后接入电网,将电池簇分散接入级联H桥变换器的直流侧,具有高度模块化的结构,对比低压方案具有单机容量大、效率高、响应速度快等明显优势。高压直挂BESS若能兼具无功补偿能力,实现系统四象限运行,将具有更大的成本优势和经济效益。电池簇接单相H桥变换器的结构,使得系统运行在高比例无功补偿工况时,电池簇电流在一个二倍基频的周期中会出现两次反向,导致电池运行在高频充放电的工况,这会对电池寿命和电池状态监测造成较大的影响。为解决这一问题,提出一种基于零序电压注入的高比例无功补偿控制方法,避免了二倍基频脉动电流对电池进行高频充放电,再通过优化零序电压的幅值和相位,最大程度上降低对电池的影响。