As a promising ultra-wide bandgap semiconductor, gallium oxide(Ga_2O_3) has attracted increasing attention in recent years. The high theoretical breakdown electrical field(8 MV/cm), ultra-wide bandgap(~ 4.8 eV) and l...As a promising ultra-wide bandgap semiconductor, gallium oxide(Ga_2O_3) has attracted increasing attention in recent years. The high theoretical breakdown electrical field(8 MV/cm), ultra-wide bandgap(~ 4.8 eV) and large Baliga's figure of merit(BFOM) of Ga_2O_3 make it a potential candidate material for next generation high-power electronics, including diode and field effect transistor(FET). In this paper, we introduce the basic physical properties of Ga_2O_3 single crystal, and review the recent research process of Ga_2O_3 based field effect transistors. Furthermore, various structures of FETs have been summarized and compared, and the potential of Ga_2O_3 is preliminary revealed. Finally, the prospect of the Ga_2O_3 based FET for power electronics application is analyzed.展开更多
This paper presents the preliminary design of poloidal field power supply system of HT-7U super-conducting tokamak. With an emphasis on AC/DC power converter, DC circuit breaker, quench protection, harmonic suppressio...This paper presents the preliminary design of poloidal field power supply system of HT-7U super-conducting tokamak. With an emphasis on AC/DC power converter, DC circuit breaker, quench protection, harmonic suppression and static var. compensation, and AC power system, the design principle and features are introduced, the design scheme and R & D progress are described, the simulation studies and laboratory test are presented too.展开更多
Sequential control applied to the International Thermonuclear Experimental Re- actor (ITER) poloidal field converter system for the purpose of reactive power reduction is the subject of this investigation. Due to th...Sequential control applied to the International Thermonuclear Experimental Re- actor (ITER) poloidal field converter system for the purpose of reactive power reduction is the subject of this investigation. Due to the inherent characteristics of thyristor-based phase-controlled converter, the poloidal field converter system consumes a huge amount of reactive power from the grid, which subsequently results in a voltage drop at the 66 kV busbar if no measure is taken. The installation of a static var compensator rated for 750 MVar at the 66 kV busbax is an essential way to compensate reactive power to the grid, which is the most effective measure to solve the problem. However, sequential control of the multi-series converters provides an additional method to improve the natural power factor and thus alleviate the pressure of reactive power demand of the converter system without any additional cost. In the present paper, by comparing with the symmetrical control technique, the advantage of sequential control in reactive power consumption is highlighted. Simulation results based on SIMULINK are found in agreement with the theoretical analysis.展开更多
Strong inductive coupling between the heating field and equilibrium field is confirmed to be responsible for the poor plasma equilibrium in initial discharges on the SUNIST spherical tokamak. A modification project fo...Strong inductive coupling between the heating field and equilibrium field is confirmed to be responsible for the poor plasma equilibrium in initial discharges on the SUNIST spherical tokamak. A modification project for the power supply system of equilibrium field coils is successfully performed to increase the duration time of plasma current flattop from much less than 1ms to about 2 ms.展开更多
A novel source-connected field plate structure, featuring the same photolithography mask as the gate electrode, is proposed as an improvement over the conventional field plate (FP) techniques to enhance the frequenc...A novel source-connected field plate structure, featuring the same photolithography mask as the gate electrode, is proposed as an improvement over the conventional field plate (FP) techniques to enhance the frequency performance in GaN-based HEMTs. The influences of the field plate on frequency and breakdown performance are investigated simul- taneously by using a two-dimensional physics-based simulation. Compared with the conventional T-gate structures with a field plate length of 1.2 gm, this field plate structure can induce the small signal power gain at 10 GHz to increase by 5-9.5 dB, which depends on the distance between source FP and dramatically shortened gate FE This technique minimizes the parasitic capacitances, especially the gate-to-drain capacitance, showing a substantial potential for millimeter-wave, high power applications.展开更多
Abstract Objective Higher levels of exposure to extremely low-frequency magnetic fields (ELF-MF) are associated with a slightly increased risk of childhood leukaemia. Compared with more-developed Western countries, ...Abstract Objective Higher levels of exposure to extremely low-frequency magnetic fields (ELF-MF) are associated with a slightly increased risk of childhood leukaemia. Compared with more-developed Western countries, higher exposure levels are evident in the Czech Republic, probably because of the different types of housing. In light of this, we aimed to examine the association between ELF-MF exposure and childhood leukaemia in the Czech Republic. Methods We conducted a paired case-control study. The cases (children with leukaemia) were age- sex- and permanent residence-matched to controls (children without leukaemia). Although this limited potential bias and confounding, it also limited our number of participants. Results The matched analyses included 79 case-control pairs. No significant association between ELF-MF exposure and childhood leukaemia was observed for exposures over 0.2 μT (odds ratio [0R]=0.93, confidence interval [Cl]=0.45-1.93), 0.3 μT (0R=0.77, Cl=0.34-1.75), or 0.4 μT (OR=0.9, Cl=0.37-2.22). Conclusion Despite higher levels of exposure in Middle and Eastern Europe, no indication of an association between ELF-MF exposure and childhood leukaemia was determined. This in contrast to the findings of previous studies conducted in different countries.展开更多
Joint-TEXT (J-TEXT) is a medium-sized tokamak constructed at Huazhong University of Science and Technology. At present, the poloidal field power supply consists of three subsystem sets, namely Ohmic heating field po...Joint-TEXT (J-TEXT) is a medium-sized tokamak constructed at Huazhong University of Science and Technology. At present, the poloidal field power supply consists of three subsystem sets, namely Ohmic heating field power supply, vertical field power supply, and horizontal field power supply. The structure and function of the poloidal field (PF) power supply as well as the updated control system of the power supply is described. The new scheme uses the realtime feedback control method for the poloidal field power supply. The experimental results show that the poloidal field energized by poloidal field power supply meets the J-TEXT operational requirement perfectly.展开更多
An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of succe...An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of successive images,the proposed method has the number and location of the simulated charges not arbitrary.When the surface electric field of a conductor exceeds the onset value,charges are emitted from corona into the space around,and the space ions and the surface charges on each sub-conductor are simulated by using the images of the other sub-conductors.The displacements of the space ions are calculated at every time step during corona periods in both the positive and the negative half cycles.Several examples are calculated by using the proposed method,and the calculated electric field at the ground level and the corona power loss agree well with previous measurements.The results show that simulating 12 charges in each conductor during 600 time steps in one cycle takes less time while guarantees the accuracy.The corona discharge from a 220 kV transmission line enhances slightly(less than 2%) the electric field at the ground level,but this effect is little from a 500 kV line.The improved method is a good compromise between the time cost and the accuracy of calculation.展开更多
Local field potential(LFP) signals of the rat hippocampus were recorded under noninvasive focused ultrasound stimulation(FUS) with different ultrasonic powers. The LFP mean absolute power was calculated with the Welch...Local field potential(LFP) signals of the rat hippocampus were recorded under noninvasive focused ultrasound stimulation(FUS) with different ultrasonic powers. The LFP mean absolute power was calculated with the Welch algorithm at the delta, theta, alpha, beta, and gamma frequency bands. The experimental results demonstrate that the LFP mean absolute power at different frequency bands increases as the ultrasound power increases.展开更多
The air breakdown in the high-power antenna near-field region limits the enhancement of the radiated power. A model coupling the field equivalent principle and the electron number density equation is presented to stud...The air breakdown in the high-power antenna near-field region limits the enhancement of the radiated power. A model coupling the field equivalent principle and the electron number density equation is presented to study the breakdown process in the near-field region of the circular aperture antenna at atmospheric pressure. Simulation results show that, although the electric field in the near-field region is nonuniform, the electron diffusion has small influence on the breakdown process when the initial electron number density is uniform in space. The field magnitude distribution on the aperture plays an important role in the maximum radiated power above which the air breakdown occurs. The maximum radiated power also depends on the phase difference of the fields at the center and edge of the aperture, especially for the uniform field magnitude distribution.展开更多
The center post is the most critical component as an inboard part of the toroidal field coil for the low aspect ratio tokamak. During the discharge it endures not only a tremendous ohmic heating owing to its carrying ...The center post is the most critical component as an inboard part of the toroidal field coil for the low aspect ratio tokamak. During the discharge it endures not only a tremendous ohmic heating owing to its carrying a rather high current but also a large nuclear heating and irradiation owing to the plasma operation. All the severe operating conditions, including the structure stress intensity and the stability of the structure, largely limit the maximum allowable current density. But in order to contain a very high dense plasma, it is hoped that the fusion power plant system can operate with a much high maximum magnetic field BT ≥12 T-15 T in the center post. A new method is presented in this paper to improve the maximum magnetic field up to 17 T and to investigate the possibility of the normal conducting center post to be used in the future fusion tokamak power plant.展开更多
This paper has proposed a new methodology extracting stability classes of field association words depending on automatically power link analysis to enhance the precision of decision tree. In this paper, we have studie...This paper has proposed a new methodology extracting stability classes of field association words depending on automatically power link analysis to enhance the precision of decision tree. In this paper, we have studied the effects of the time variation based on the frequencies of specific words called field association words that connected to documents using power link in a specific period. The stability classes have referred to the popularity of field association words based on the change of time in a given period. The new approach has evaluated by conducting experiments simulating results of 1575 files (about 5.16 MB). Based on these experiments, it has turned out that, the F-measure for ascending, stable and descending classes have achieved 93.6%, 99.8% and 75.7%, respectively. These results mean that F-measure was increasing by 12%, 4% and 34% than traditional methods because of the power link analysis.展开更多
This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field ...This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field and the short-circuit capacity of our transformer substation. The designed parameters of the PF grid power supply system have been verified to meet the requirements of the heating field (HF) and the vertical field (VF). In the meantime, in order to reduce the disturbance to the local power grid, the device of reactive power and harmonic current compensation has been added. Experimental results have confirmed the feasibility of the PF grid power supply system. Compared with the ac flywheel generator, the PF grid power supply system has the advantages of lower noise, precise control, convenient maintenance, simple operation and cost savings.展开更多
This paper describes a conceptual design study for the circuit configuration of the Error Field Correction Coil (EFCC) power supply (PS) to maximize the expected performance with reasonable cost in JT-60SA. The EF...This paper describes a conceptual design study for the circuit configuration of the Error Field Correction Coil (EFCC) power supply (PS) to maximize the expected performance with reasonable cost in JT-60SA. The EFCC consists of eighteen sector coils installed inside the vacuum vessel, six in the toroidal direction and three in the poloidal direction, each one rated for 30 kA-turn. As a result, star point connection is proposed for each group of six EFCC coils installed cyclically in the toroidal direction for decoupling with poloidal field coils. In addition~ a six phase inverter which is capable of controlling each phase current was chosen as PS topology to ensure higher flexibility of operation with reasonable cost.展开更多
A three-dimensional approach to the effect of magnetic field incidence angle on electrical power and conversion efficiency is performed on a front-illuminated polycrystalline silicon bifacial solar cell. A solution of...A three-dimensional approach to the effect of magnetic field incidence angle on electrical power and conversion efficiency is performed on a front-illuminated polycrystalline silicon bifacial solar cell. A solution of the continuity equation allowed us to present the equations of photocurrent density, photovoltage and electric power. The influence of the angle of incidence of the magnetic field on the photocurrent density, the photovoltage and the electric power has been studied. The curves of electrical power versus dynamic junction velocity were used to extract the values of maximum electrical power and dynamic junction velocity and to calculate those of conversion efficiency. From this study, it is found that the conversion efficiency values increase with the angle of incidence of the magnetic field.展开更多
Our purpose in this study was to present a method for estimating the specific loss power (SLP) in magnetic hyperthermia in the presence of an external static magnetic field (SMF) and to investigate the SLP values esti...Our purpose in this study was to present a method for estimating the specific loss power (SLP) in magnetic hyperthermia in the presence of an external static magnetic field (SMF) and to investigate the SLP values estimated by this method under various diameters (D) of magnetic nanoparticles (MNPs) and amplitudes (H<sub>0</sub>) and frequencies (f) of an alternating magnetic field (AMF). In our method, the SLP was calculated by solving the magnetization relaxation equation of Shliomis numerically, in which the magnetic field strength at time t (H(t)) was assumed to be given by , with H<sub>s</sub> being the strength of the SMF. We also investigated the SLP values in the case when the SMF with a field-free point (FFP) generated by two solenoid coils was used. The SLP value in the quasi steady state (SLP<sub>qss</sub>) decreased with increasing H<sub>s</sub>. The plot of the SLP<sub>qss</sub> values against the position from the FFP became narrow as the gradient strength of the SMF (G<sub>s</sub>) increased. Conversely, it became broad as G<sub>s</sub> decreased. These results suggest that the temperature rise and the area of local heating in magnetic hyperthermia can be controlled by varying the H<sub>s</sub> and G<sub>s</sub> values, respectively. In conclusion, our method will be useful for estimating the SLP in the presence of both the AMF and SMF and for designing an effective local heating system for magnetic hyperthermia in order to reduce the risk of overheating surrounding healthy tissues.展开更多
The study of Electromagnetic Compatibility is essential to ensure the harmonious operation of electronic equipment in a shared environment. The basic principles of Electromagnetic Compatibility focus on the ability of...The study of Electromagnetic Compatibility is essential to ensure the harmonious operation of electronic equipment in a shared environment. The basic principles of Electromagnetic Compatibility focus on the ability of devices to withstand electromagnetic disturbances and not produce disturbances that could affect other systems. Imperceptible in most work situations, electromagnetic fields can, beyond certain thresholds, have effects on human health. The objective of the present article is focused on the modeling analysis of the influence of geometric parameters of industrial static converters radiated electromagnetic fields using Maxwell’s equations. To do this we used the analytical formalism for calculating the electromagnetic field emitted by a filiform conductor, to model the electromagnetic radiation of this device in the spatio-temporal domain. The interactions of electromagnetic waves with human bodies are complex and depend on several factors linked to the characteristics of the incident wave. To model these interactions, we implemented the physical laws of electromagnetic wave propagation based on Maxwell’s and bio-heat equations to obtain consistent results. These obtained models allowed us to evaluate the spatial profile of induced current and temperature of biological tissue during exposure to electromagnetic waves generated by this system. The simulation 2D results obtained from computer tools show that the temperature variation and current induced by the electromagnetic field can have a very significant influence on the life of biological tissue. The paper provides a comprehensive analysis using advanced mathematical models to evaluate the influence of electromagnetic fields. The findings have direct implications for workplace safety, potentially influencing standards and regulations concerning electromagnetic exposure in industrial settings.展开更多
According to surveyed literature, there may be a health hazard associated with extremely low frequency magnetic fields. This study aims at presenting a recent survey of this literature. It also aims at measuring magne...According to surveyed literature, there may be a health hazard associated with extremely low frequency magnetic fields. This study aims at presenting a recent survey of this literature. It also aims at measuring magnetic field levels close to power transmission lines at inhabited areas in Kuwait to see if current levels are safe and to establish a database of 50 Hz magnetic field levels at inhabited areas. Measurements were made, according to the international standard procedures in winter, spring, summer and fall, and three times of a day. Four inhabited areas were surveyed. Results provide us with an independent view of the levels in the vicinity of power lines and houses. Results show that the highest level is measured in the summer, reaching 115 mG while the minimum level is measured in the fall. We found that some houses were at less than 50 meters distance from the edge of the transmission lines. Some houses were, as close as 22 meters to the line. We found that levels at the entrance of houses and at outdoor parking areas were mostly higher than 4 mG.展开更多
Wireless relay and network coding are two critical techniques to increase the reliability and throughput of wireless cooperative communication systems. In this paper, a complex field network coding (CFNC) scheme wit...Wireless relay and network coding are two critical techniques to increase the reliability and throughput of wireless cooperative communication systems. In this paper, a complex field network coding (CFNC) scheme with the K-th best relay selection (KBS) is proposed and investigated, wherein the K-th best relay is selected to forward the multiplexed signal to the destination. First, the upper bound of the symbol error probability (SEP), the diversity order, and the coding gain are derived for the CFNC scheme with KBS. Then, the coding gain is utilized as the optimized cri- terion to determine the optimal power allocation. It is validated through analysis and simulation that the CFNC scheme with KBS can achieve full diversity only when K=I, while the diversity order decreases with increasing parameter K, and the optimal power allocation can significantly improve the performance of the CFNC scheme with KBS.展开更多
基金supported by the National Natural Science Foundation of China(Nos.61521064,61522408,61574169,6 1334007,61474136,61574166)the Ministry of Science andTechnology of China(Nos.2016YFA0201803,2016YFA0203800,2017YFB0405603)+2 种基金the Key Research Program of Frontier Sciences of Chinese Academy of Sciences(Nos.QYZDB-SSWJSC048,QYZDY-SSW-JSC001)the Beijing Municipal Science and Technology Project(No.Z171100002017011)the Opening Project of the Key Laboratory of Microelectronic Devices&Integration Technology,Institute of Microelectronics of Chinese Academy of Sciences
文摘As a promising ultra-wide bandgap semiconductor, gallium oxide(Ga_2O_3) has attracted increasing attention in recent years. The high theoretical breakdown electrical field(8 MV/cm), ultra-wide bandgap(~ 4.8 eV) and large Baliga's figure of merit(BFOM) of Ga_2O_3 make it a potential candidate material for next generation high-power electronics, including diode and field effect transistor(FET). In this paper, we introduce the basic physical properties of Ga_2O_3 single crystal, and review the recent research process of Ga_2O_3 based field effect transistors. Furthermore, various structures of FETs have been summarized and compared, and the potential of Ga_2O_3 is preliminary revealed. Finally, the prospect of the Ga_2O_3 based FET for power electronics application is analyzed.
文摘This paper presents the preliminary design of poloidal field power supply system of HT-7U super-conducting tokamak. With an emphasis on AC/DC power converter, DC circuit breaker, quench protection, harmonic suppression and static var. compensation, and AC power system, the design principle and features are introduced, the design scheme and R & D progress are described, the simulation studies and laboratory test are presented too.
基金supported by International Cooperation Project of Ministry of Science and Technology of China(4.1.P2.CN.01/1A)
文摘Sequential control applied to the International Thermonuclear Experimental Re- actor (ITER) poloidal field converter system for the purpose of reactive power reduction is the subject of this investigation. Due to the inherent characteristics of thyristor-based phase-controlled converter, the poloidal field converter system consumes a huge amount of reactive power from the grid, which subsequently results in a voltage drop at the 66 kV busbar if no measure is taken. The installation of a static var compensator rated for 750 MVar at the 66 kV busbax is an essential way to compensate reactive power to the grid, which is the most effective measure to solve the problem. However, sequential control of the multi-series converters provides an additional method to improve the natural power factor and thus alleviate the pressure of reactive power demand of the converter system without any additional cost. In the present paper, by comparing with the symmetrical control technique, the advantage of sequential control in reactive power consumption is highlighted. Simulation results based on SIMULINK are found in agreement with the theoretical analysis.
文摘Strong inductive coupling between the heating field and equilibrium field is confirmed to be responsible for the poor plasma equilibrium in initial discharges on the SUNIST spherical tokamak. A modification project for the power supply system of equilibrium field coils is successfully performed to increase the duration time of plasma current flattop from much less than 1ms to about 2 ms.
基金supported by the Program for New Century Excellent Talents in University, China (Grant No. NCET-12-0915)the National Natural Science Foundation of China (Grant No. 61106106)the Fundamental Research Funds for the Central Universities, China (Grant No. K5051225013)
文摘A novel source-connected field plate structure, featuring the same photolithography mask as the gate electrode, is proposed as an improvement over the conventional field plate (FP) techniques to enhance the frequency performance in GaN-based HEMTs. The influences of the field plate on frequency and breakdown performance are investigated simul- taneously by using a two-dimensional physics-based simulation. Compared with the conventional T-gate structures with a field plate length of 1.2 gm, this field plate structure can induce the small signal power gain at 10 GHz to increase by 5-9.5 dB, which depends on the distance between source FP and dramatically shortened gate FE This technique minimizes the parasitic capacitances, especially the gate-to-drain capacitance, showing a substantial potential for millimeter-wave, high power applications.
文摘Abstract Objective Higher levels of exposure to extremely low-frequency magnetic fields (ELF-MF) are associated with a slightly increased risk of childhood leukaemia. Compared with more-developed Western countries, higher exposure levels are evident in the Czech Republic, probably because of the different types of housing. In light of this, we aimed to examine the association between ELF-MF exposure and childhood leukaemia in the Czech Republic. Methods We conducted a paired case-control study. The cases (children with leukaemia) were age- sex- and permanent residence-matched to controls (children without leukaemia). Although this limited potential bias and confounding, it also limited our number of participants. Results The matched analyses included 79 case-control pairs. No significant association between ELF-MF exposure and childhood leukaemia was observed for exposures over 0.2 μT (odds ratio [0R]=0.93, confidence interval [Cl]=0.45-1.93), 0.3 μT (0R=0.77, Cl=0.34-1.75), or 0.4 μT (OR=0.9, Cl=0.37-2.22). Conclusion Despite higher levels of exposure in Middle and Eastern Europe, no indication of an association between ELF-MF exposure and childhood leukaemia was determined. This in contrast to the findings of previous studies conducted in different countries.
基金supported by National Basic Research Program 973 Program of China(No.2008CB717805)
文摘Joint-TEXT (J-TEXT) is a medium-sized tokamak constructed at Huazhong University of Science and Technology. At present, the poloidal field power supply consists of three subsystem sets, namely Ohmic heating field power supply, vertical field power supply, and horizontal field power supply. The structure and function of the poloidal field (PF) power supply as well as the updated control system of the power supply is described. The new scheme uses the realtime feedback control method for the poloidal field power supply. The experimental results show that the poloidal field energized by poloidal field power supply meets the J-TEXT operational requirement perfectly.
基金supported by National Basic Research Program of China(973 Program)(2011CB209404)
文摘An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of successive images,the proposed method has the number and location of the simulated charges not arbitrary.When the surface electric field of a conductor exceeds the onset value,charges are emitted from corona into the space around,and the space ions and the surface charges on each sub-conductor are simulated by using the images of the other sub-conductors.The displacements of the space ions are calculated at every time step during corona periods in both the positive and the negative half cycles.Several examples are calculated by using the proposed method,and the calculated electric field at the ground level and the corona power loss agree well with previous measurements.The results show that simulating 12 charges in each conductor during 600 time steps in one cycle takes less time while guarantees the accuracy.The corona discharge from a 220 kV transmission line enhances slightly(less than 2%) the electric field at the ground level,but this effect is little from a 500 kV line.The improved method is a good compromise between the time cost and the accuracy of calculation.
基金supported by the National Natural Science Foundation of China(Grant No.61273063)China Postdoctoral Science Foundation(Grant No.2013M540215)the Natural Science Foundation of Hebei Province,China(Grant No.F2014203161)
文摘Local field potential(LFP) signals of the rat hippocampus were recorded under noninvasive focused ultrasound stimulation(FUS) with different ultrasonic powers. The LFP mean absolute power was calculated with the Welch algorithm at the delta, theta, alpha, beta, and gamma frequency bands. The experimental results demonstrate that the LFP mean absolute power at different frequency bands increases as the ultrasound power increases.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61501358,11622542,61431010,and 61627901)the Fundamental Research Funds for the Central Universities,China
文摘The air breakdown in the high-power antenna near-field region limits the enhancement of the radiated power. A model coupling the field equivalent principle and the electron number density equation is presented to study the breakdown process in the near-field region of the circular aperture antenna at atmospheric pressure. Simulation results show that, although the electric field in the near-field region is nonuniform, the electron diffusion has small influence on the breakdown process when the initial electron number density is uniform in space. The field magnitude distribution on the aperture plays an important role in the maximum radiated power above which the air breakdown occurs. The maximum radiated power also depends on the phase difference of the fields at the center and edge of the aperture, especially for the uniform field magnitude distribution.
基金The project supported by the Ministry of Education, Culture, Sports, Science and Technology (MEXT) Nuclear Researchers Exchange Program of Japan
文摘The center post is the most critical component as an inboard part of the toroidal field coil for the low aspect ratio tokamak. During the discharge it endures not only a tremendous ohmic heating owing to its carrying a rather high current but also a large nuclear heating and irradiation owing to the plasma operation. All the severe operating conditions, including the structure stress intensity and the stability of the structure, largely limit the maximum allowable current density. But in order to contain a very high dense plasma, it is hoped that the fusion power plant system can operate with a much high maximum magnetic field BT ≥12 T-15 T in the center post. A new method is presented in this paper to improve the maximum magnetic field up to 17 T and to investigate the possibility of the normal conducting center post to be used in the future fusion tokamak power plant.
文摘This paper has proposed a new methodology extracting stability classes of field association words depending on automatically power link analysis to enhance the precision of decision tree. In this paper, we have studied the effects of the time variation based on the frequencies of specific words called field association words that connected to documents using power link in a specific period. The stability classes have referred to the popularity of field association words based on the change of time in a given period. The new approach has evaluated by conducting experiments simulating results of 1575 files (about 5.16 MB). Based on these experiments, it has turned out that, the F-measure for ascending, stable and descending classes have achieved 93.6%, 99.8% and 75.7%, respectively. These results mean that F-measure was increasing by 12%, 4% and 34% than traditional methods because of the power link analysis.
基金The project supported by the Meg-science Engineering Project of the Chinese Academy of Sciences
文摘This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field and the short-circuit capacity of our transformer substation. The designed parameters of the PF grid power supply system have been verified to meet the requirements of the heating field (HF) and the vertical field (VF). In the meantime, in order to reduce the disturbance to the local power grid, the device of reactive power and harmonic current compensation has been added. Experimental results have confirmed the feasibility of the PF grid power supply system. Compared with the ac flywheel generator, the PF grid power supply system has the advantages of lower noise, precise control, convenient maintenance, simple operation and cost savings.
基金supported within the framework of the "Broader Approach Internationals Agreement"
文摘This paper describes a conceptual design study for the circuit configuration of the Error Field Correction Coil (EFCC) power supply (PS) to maximize the expected performance with reasonable cost in JT-60SA. The EFCC consists of eighteen sector coils installed inside the vacuum vessel, six in the toroidal direction and three in the poloidal direction, each one rated for 30 kA-turn. As a result, star point connection is proposed for each group of six EFCC coils installed cyclically in the toroidal direction for decoupling with poloidal field coils. In addition~ a six phase inverter which is capable of controlling each phase current was chosen as PS topology to ensure higher flexibility of operation with reasonable cost.
文摘A three-dimensional approach to the effect of magnetic field incidence angle on electrical power and conversion efficiency is performed on a front-illuminated polycrystalline silicon bifacial solar cell. A solution of the continuity equation allowed us to present the equations of photocurrent density, photovoltage and electric power. The influence of the angle of incidence of the magnetic field on the photocurrent density, the photovoltage and the electric power has been studied. The curves of electrical power versus dynamic junction velocity were used to extract the values of maximum electrical power and dynamic junction velocity and to calculate those of conversion efficiency. From this study, it is found that the conversion efficiency values increase with the angle of incidence of the magnetic field.
文摘Our purpose in this study was to present a method for estimating the specific loss power (SLP) in magnetic hyperthermia in the presence of an external static magnetic field (SMF) and to investigate the SLP values estimated by this method under various diameters (D) of magnetic nanoparticles (MNPs) and amplitudes (H<sub>0</sub>) and frequencies (f) of an alternating magnetic field (AMF). In our method, the SLP was calculated by solving the magnetization relaxation equation of Shliomis numerically, in which the magnetic field strength at time t (H(t)) was assumed to be given by , with H<sub>s</sub> being the strength of the SMF. We also investigated the SLP values in the case when the SMF with a field-free point (FFP) generated by two solenoid coils was used. The SLP value in the quasi steady state (SLP<sub>qss</sub>) decreased with increasing H<sub>s</sub>. The plot of the SLP<sub>qss</sub> values against the position from the FFP became narrow as the gradient strength of the SMF (G<sub>s</sub>) increased. Conversely, it became broad as G<sub>s</sub> decreased. These results suggest that the temperature rise and the area of local heating in magnetic hyperthermia can be controlled by varying the H<sub>s</sub> and G<sub>s</sub> values, respectively. In conclusion, our method will be useful for estimating the SLP in the presence of both the AMF and SMF and for designing an effective local heating system for magnetic hyperthermia in order to reduce the risk of overheating surrounding healthy tissues.
文摘The study of Electromagnetic Compatibility is essential to ensure the harmonious operation of electronic equipment in a shared environment. The basic principles of Electromagnetic Compatibility focus on the ability of devices to withstand electromagnetic disturbances and not produce disturbances that could affect other systems. Imperceptible in most work situations, electromagnetic fields can, beyond certain thresholds, have effects on human health. The objective of the present article is focused on the modeling analysis of the influence of geometric parameters of industrial static converters radiated electromagnetic fields using Maxwell’s equations. To do this we used the analytical formalism for calculating the electromagnetic field emitted by a filiform conductor, to model the electromagnetic radiation of this device in the spatio-temporal domain. The interactions of electromagnetic waves with human bodies are complex and depend on several factors linked to the characteristics of the incident wave. To model these interactions, we implemented the physical laws of electromagnetic wave propagation based on Maxwell’s and bio-heat equations to obtain consistent results. These obtained models allowed us to evaluate the spatial profile of induced current and temperature of biological tissue during exposure to electromagnetic waves generated by this system. The simulation 2D results obtained from computer tools show that the temperature variation and current induced by the electromagnetic field can have a very significant influence on the life of biological tissue. The paper provides a comprehensive analysis using advanced mathematical models to evaluate the influence of electromagnetic fields. The findings have direct implications for workplace safety, potentially influencing standards and regulations concerning electromagnetic exposure in industrial settings.
文摘According to surveyed literature, there may be a health hazard associated with extremely low frequency magnetic fields. This study aims at presenting a recent survey of this literature. It also aims at measuring magnetic field levels close to power transmission lines at inhabited areas in Kuwait to see if current levels are safe and to establish a database of 50 Hz magnetic field levels at inhabited areas. Measurements were made, according to the international standard procedures in winter, spring, summer and fall, and three times of a day. Four inhabited areas were surveyed. Results provide us with an independent view of the levels in the vicinity of power lines and houses. Results show that the highest level is measured in the summer, reaching 115 mG while the minimum level is measured in the fall. We found that some houses were at less than 50 meters distance from the edge of the transmission lines. Some houses were, as close as 22 meters to the line. We found that levels at the entrance of houses and at outdoor parking areas were mostly higher than 4 mG.
基金supported by the Major State Basic Research Development Program of China(973 Program No.2012CB316100)the National Natural Science Foundation of China(Nos.61032002/61271246)the 111 Project(No.111-2-14)
文摘Wireless relay and network coding are two critical techniques to increase the reliability and throughput of wireless cooperative communication systems. In this paper, a complex field network coding (CFNC) scheme with the K-th best relay selection (KBS) is proposed and investigated, wherein the K-th best relay is selected to forward the multiplexed signal to the destination. First, the upper bound of the symbol error probability (SEP), the diversity order, and the coding gain are derived for the CFNC scheme with KBS. Then, the coding gain is utilized as the optimized cri- terion to determine the optimal power allocation. It is validated through analysis and simulation that the CFNC scheme with KBS can achieve full diversity only when K=I, while the diversity order decreases with increasing parameter K, and the optimal power allocation can significantly improve the performance of the CFNC scheme with KBS.