In generator design field,waveform total harmonic distortion(THD)and telephone harmonic factor(THF)are parameters commonly used to measure the impact of generator no-load voltage harmonics on the power communication q...In generator design field,waveform total harmonic distortion(THD)and telephone harmonic factor(THF)are parameters commonly used to measure the impact of generator no-load voltage harmonics on the power communication quality.Tubular hydrogenerators are considered the optimal generator for exploiting low-head,high-flow hydro resources,and they have seen increasingly widespread application in China's power systems recent years.However,owing to the compact and constrained internal space of such generators,their internal magnetic-field harmonics are pronounced.Therefore,accurate calculation of their THD and THF is crucial during the analysis and design stages to ensure the quality of power communication.Especially in the electromagnetic field finite element modeling analysis of such generators,the type and order of the finite element meshes may have a significant impact on the THD and THF calculation results,which warrants in-depth research.To address this,this study takes a real 34 MW large tubular hydrogenerator as an example,and establishes its electromagnetic field finite element model under no-load conditions.Two types of meshes,five mesh densities,and two mesh orders are analyzed to reveal the effect of electromagnetic field finite element mesh types and orders on the calculation results of THD and THF for such generators.展开更多
Theoretical model and solutions on power line harmonic radiation (PLHR) propagating in the ground, air, and anisotropic homogeneous ionosphere are presented, The theoretical model is verified by the PLHR events obse...Theoretical model and solutions on power line harmonic radiation (PLHR) propagating in the ground, air, and anisotropic homogeneous ionosphere are presented, The theoretical model is verified by the PLHR events observed by the DEMETER satellite. Some propagation characteristics of PLHR based on the model are obtained. This paper is bene- ficial to quantitatively interpret the formation mechanism of PLHR phenomenon.展开更多
In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design...In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design for passive filter. Also a controlling method with fast response time and good accuracy is put forward for the compensator, which is more suitable for the dynamic load.展开更多
In recent years, the increasing application of nonlinear and unbalanced electronic equipment and large single phase loads have made voltage imbalance a serious problem in power distribution systems. A novel approach h...In recent years, the increasing application of nonlinear and unbalanced electronic equipment and large single phase loads have made voltage imbalance a serious problem in power distribution systems. A novel approach has been proposed to eliminate voltage imbalance and disturbances. The main strategy of this scheme is based on series active filter. By improving control circuit toward existing schemes and proposing a new strategy to control the voltage amplitude, simultaneous elimination of voltage imbalance, faults, voltage harmonics and also compensation of voltage drop in transmission lines become possible. Eventually, the voltage on the load side is a perfectly balanced three phase voltage with specific proper amplitude. The proposed scheme has been simulated in a test network and the results show high capability of this scheme for the complete elimination of imbalance without phase shift.展开更多
In contemporary power grids or microgrids,harmonic distortion has emerged as one of the critical power quality issues for utility power grids,which has escalated especially due to the high penetration of power-electro...In contemporary power grids or microgrids,harmonic distortion has emerged as one of the critical power quality issues for utility power grids,which has escalated especially due to the high penetration of power-electronic-converter-interfaced distributed generation(DG).This paper first illustrates the prevalent dispute revolving around the harmonic power sharing and distortion restraint,and subsequently proposes a consensusbased framework that facilitates an accurate sharing of harmonics among multi-DGs connected in parallel,with an effective suppression of the output voltage distortion.Compared with the majority of existing studies addressing the issue of voltage harmonics at the point of common coupling(PCC),our method primarily emphasizes on the output voltage distortion since the power quality requirement for certain local critical loads is often known to be high.With the help of adaptive regulation,the overall distortion produced at the output terminals of DGs can be retained within an acceptable range.The working principle of the proposed control method,which is not only easy to implement but also independent of model parameters,is further described in detail.Employing the small-signal dynamic model,the system stability and robustness are analyzed.The hardware-in-the-loop(HIL)simulations aid in determining the outcome of the proposed strategy in microgrid control.展开更多
This paper discusses a number of ways in which wind power installations can impact the harmonic levels in the power system.Wind turbines are an additional source of harmonic emission,especially when it concerns"n...This paper discusses a number of ways in which wind power installations can impact the harmonic levels in the power system.Wind turbines are an additional source of harmonic emission,especially when it concerns"non-characteristic harmonics."Parallel resonances can amplify the emission from individual turbines.A mathematical model is developed to quantify this amplification.Series resonances can result in high currents,driven by the background voltage distortion in the transmission grid,flowing into thewind park.Weakening of the transmission grid will increase lower order harmonics but reduce higher order harmonics.展开更多
We demonstrated a robust power-scalable Kerr-lens mode-locked(KLM) operation based on a Yb:YAG thin-disk oscillator.15-W,272-fs pulses were realized at a repetition rate of 86.7 MHz with an additional Kerr medium a...We demonstrated a robust power-scalable Kerr-lens mode-locked(KLM) operation based on a Yb:YAG thin-disk oscillator.15-W,272-fs pulses were realized at a repetition rate of 86.7 MHz with an additional Kerr medium and a 2.5 mm hard aperture in the cavity.247-fs pulses with an average power of 11 W could also be obtained by using a 2.4 mm hard aperture.Based on this shorter pulse,high efficient second-harmonic generation(SHG) was performed with a 1.7-mm-long Li B3O5(LBO) crystal.The SHG laser power was up to 5 W with the power fluctuation RMS of 1% measured over one hour.展开更多
The high proportion of nonlinear and unbalanced loads results in power quality issues in islanded microgrids.This paper presents a novel control strategy for harmonic and unbalanced power allocation among distributed ...The high proportion of nonlinear and unbalanced loads results in power quality issues in islanded microgrids.This paper presents a novel control strategy for harmonic and unbalanced power allocation among distributed genera-tors(DGs)in microgrids.Different from the existing sharing strategies that allocate the harmonic and unbalanced power according to the rated capacities of DGs,the proposed control strategy intends to shape the lowest output impedances of DGs to optimize the power quality of the microgrid.To achieve this goal,the feasible range of virtual impedance is analyzed in detail by eigenvalue analysis,and the findings suggest a simultaneous adjustment of real and imaginary parts of virtual impedance.Because virtual impedance is an open-loop control that imposes DG to the risk of overload,a new closed-loop structure is designed that uses residual capacity and absorbed power as feedback.Accordingly,virtual impedance can be safely adjusted in the feasible range until the power limit is reached.In addi-tion,a fuzzy integral controller is adopted to improve the dynamics and convergence of the power distribution,and its performance is found to be superior to linear integral controllers.Finally,simulations and control hardware-in-the-loop experiments are conducted to verify the effectiveness and usefulness of the proposed control strategy.展开更多
We present a new optical microscope in which the light transmitted by a sample-scanned transmission confocal microscope is frequency-tripled by SiOx nanocrystallites in lieu of being transmitted by a confocal pinhole....We present a new optical microscope in which the light transmitted by a sample-scanned transmission confocal microscope is frequency-tripled by SiOx nanocrystallites in lieu of being transmitted by a confocal pinhole. This imaging technique offers an increased contrast and a high scattered light rejection. It is demonstrated that the contrast close to the Sparrow resolution limit is enhanced and the sectioning power are increased with respect to the linear confocal detection mode. An experimental implementation is presented and compared with the conventional linear confocal mode.展开更多
A novel large-signal equivalent circuit model of RF-SOI LDMOS based on Philips MOS Model 20 (MM20) is presented. The weak avalanche effect and the power dissipation caused by self-heating are described. The RF paras...A novel large-signal equivalent circuit model of RF-SOI LDMOS based on Philips MOS Model 20 (MM20) is presented. The weak avalanche effect and the power dissipation caused by self-heating are described. The RF parasitic elements are extracted directly from measured S-parameters with analytical methods. Their final values can be obtained quickly and accurately through the necessary optimization. The model is validated in DC,AC small-signal,and large-signal analyses for an RF-SOI LDMOS of 20-fingers (channel mask length, L = 1μm,finger width, W = 50μm) gate with high resistivity substrate and body-contact. Excellent agreement is achieved between simulated and measured results for DC, S- parameters (10MHz-0.01GHz), and power characteristics, which shows our model is accurate and reliable. MM20 is improved for RF-SOI LDMOS large-signal applications. This model has been implemented in Verilog-A using the ADS circuit simulator (hpeesofsim).展开更多
基金sponsored by the National Natural Science Foundation,Youth Foundation of China,Grant/Award Number:51607146Sichuan Natural Sciences Fund,Grant/Award Number:2023NSFSC0295。
文摘In generator design field,waveform total harmonic distortion(THD)and telephone harmonic factor(THF)are parameters commonly used to measure the impact of generator no-load voltage harmonics on the power communication quality.Tubular hydrogenerators are considered the optimal generator for exploiting low-head,high-flow hydro resources,and they have seen increasingly widespread application in China's power systems recent years.However,owing to the compact and constrained internal space of such generators,their internal magnetic-field harmonics are pronounced.Therefore,accurate calculation of their THD and THF is crucial during the analysis and design stages to ensure the quality of power communication.Especially in the electromagnetic field finite element modeling analysis of such generators,the type and order of the finite element meshes may have a significant impact on the THD and THF calculation results,which warrants in-depth research.To address this,this study takes a real 34 MW large tubular hydrogenerator as an example,and establishes its electromagnetic field finite element model under no-load conditions.Two types of meshes,five mesh densities,and two mesh orders are analyzed to reveal the effect of electromagnetic field finite element mesh types and orders on the calculation results of THD and THF for such generators.
基金Project supported by the National Natural Science Foundation of China(Grant No.51207006)the Natural Science Foundation of Beijing,China(Grant No.3123038)
文摘Theoretical model and solutions on power line harmonic radiation (PLHR) propagating in the ground, air, and anisotropic homogeneous ionosphere are presented, The theoretical model is verified by the PLHR events observed by the DEMETER satellite. Some propagation characteristics of PLHR based on the model are obtained. This paper is bene- ficial to quantitatively interpret the formation mechanism of PLHR phenomenon.
文摘In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design for passive filter. Also a controlling method with fast response time and good accuracy is put forward for the compensator, which is more suitable for the dynamic load.
文摘In recent years, the increasing application of nonlinear and unbalanced electronic equipment and large single phase loads have made voltage imbalance a serious problem in power distribution systems. A novel approach has been proposed to eliminate voltage imbalance and disturbances. The main strategy of this scheme is based on series active filter. By improving control circuit toward existing schemes and proposing a new strategy to control the voltage amplitude, simultaneous elimination of voltage imbalance, faults, voltage harmonics and also compensation of voltage drop in transmission lines become possible. Eventually, the voltage on the load side is a perfectly balanced three phase voltage with specific proper amplitude. The proposed scheme has been simulated in a test network and the results show high capability of this scheme for the complete elimination of imbalance without phase shift.
基金supported by the National Science Foundation of China under Grant 52007031the National Science Foundation of Jiangsu Province under Grant BK20200404,the“Zhishan”Yong Scholars Programs of Southeast University,and the Project Funding for Jiangsu Provincial Key Laboratory of Smart Grid Technology and Equipment,Southeast University.
文摘In contemporary power grids or microgrids,harmonic distortion has emerged as one of the critical power quality issues for utility power grids,which has escalated especially due to the high penetration of power-electronic-converter-interfaced distributed generation(DG).This paper first illustrates the prevalent dispute revolving around the harmonic power sharing and distortion restraint,and subsequently proposes a consensusbased framework that facilitates an accurate sharing of harmonics among multi-DGs connected in parallel,with an effective suppression of the output voltage distortion.Compared with the majority of existing studies addressing the issue of voltage harmonics at the point of common coupling(PCC),our method primarily emphasizes on the output voltage distortion since the power quality requirement for certain local critical loads is often known to be high.With the help of adaptive regulation,the overall distortion produced at the output terminals of DGs can be retained within an acceptable range.The working principle of the proposed control method,which is not only easy to implement but also independent of model parameters,is further described in detail.Employing the small-signal dynamic model,the system stability and robustness are analyzed.The hardware-in-the-loop(HIL)simulations aid in determining the outcome of the proposed strategy in microgrid control.
基金This study was supported by the VindForsk program,through Elforsk AB,by Alstom Grid,and by Skelleftea Kraft Elnat AB.
文摘This paper discusses a number of ways in which wind power installations can impact the harmonic levels in the power system.Wind turbines are an additional source of harmonic emission,especially when it concerns"non-characteristic harmonics."Parallel resonances can amplify the emission from individual turbines.A mathematical model is developed to quantify this amplification.Series resonances can result in high currents,driven by the background voltage distortion in the transmission grid,flowing into thewind park.Weakening of the transmission grid will increase lower order harmonics but reduce higher order harmonics.
基金Project supported by the National Basic Research Program of China(Grant No.2013CB922402)the National Major Instrument Program of China(Grant No.2012YQ120047)the National Natural Science Foundation of China(Grant Nos.11434016 and 61210017)
文摘We demonstrated a robust power-scalable Kerr-lens mode-locked(KLM) operation based on a Yb:YAG thin-disk oscillator.15-W,272-fs pulses were realized at a repetition rate of 86.7 MHz with an additional Kerr medium and a 2.5 mm hard aperture in the cavity.247-fs pulses with an average power of 11 W could also be obtained by using a 2.4 mm hard aperture.Based on this shorter pulse,high efficient second-harmonic generation(SHG) was performed with a 1.7-mm-long Li B3O5(LBO) crystal.The SHG laser power was up to 5 W with the power fluctuation RMS of 1% measured over one hour.
基金supported by the Science and Technology Project of SGCC under grant 5400-202219417A-2-0-ZN.
文摘The high proportion of nonlinear and unbalanced loads results in power quality issues in islanded microgrids.This paper presents a novel control strategy for harmonic and unbalanced power allocation among distributed genera-tors(DGs)in microgrids.Different from the existing sharing strategies that allocate the harmonic and unbalanced power according to the rated capacities of DGs,the proposed control strategy intends to shape the lowest output impedances of DGs to optimize the power quality of the microgrid.To achieve this goal,the feasible range of virtual impedance is analyzed in detail by eigenvalue analysis,and the findings suggest a simultaneous adjustment of real and imaginary parts of virtual impedance.Because virtual impedance is an open-loop control that imposes DG to the risk of overload,a new closed-loop structure is designed that uses residual capacity and absorbed power as feedback.Accordingly,virtual impedance can be safely adjusted in the feasible range until the power limit is reached.In addi-tion,a fuzzy integral controller is adopted to improve the dynamics and convergence of the power distribution,and its performance is found to be superior to linear integral controllers.Finally,simulations and control hardware-in-the-loop experiments are conducted to verify the effectiveness and usefulness of the proposed control strategy.
基金The Si0x nanocrystals and clusters were deposited by D. Scuderi, 0. Albert, A. Dos Santos and J. Etchepare at the L0A. We thank Bertrand Reynier, Unité de Mécanique, ENSTA, France, for sample characterization by electron microscopy.
文摘We present a new optical microscope in which the light transmitted by a sample-scanned transmission confocal microscope is frequency-tripled by SiOx nanocrystallites in lieu of being transmitted by a confocal pinhole. This imaging technique offers an increased contrast and a high scattered light rejection. It is demonstrated that the contrast close to the Sparrow resolution limit is enhanced and the sectioning power are increased with respect to the linear confocal detection mode. An experimental implementation is presented and compared with the conventional linear confocal mode.
文摘A novel large-signal equivalent circuit model of RF-SOI LDMOS based on Philips MOS Model 20 (MM20) is presented. The weak avalanche effect and the power dissipation caused by self-heating are described. The RF parasitic elements are extracted directly from measured S-parameters with analytical methods. Their final values can be obtained quickly and accurately through the necessary optimization. The model is validated in DC,AC small-signal,and large-signal analyses for an RF-SOI LDMOS of 20-fingers (channel mask length, L = 1μm,finger width, W = 50μm) gate with high resistivity substrate and body-contact. Excellent agreement is achieved between simulated and measured results for DC, S- parameters (10MHz-0.01GHz), and power characteristics, which shows our model is accurate and reliable. MM20 is improved for RF-SOI LDMOS large-signal applications. This model has been implemented in Verilog-A using the ADS circuit simulator (hpeesofsim).