期刊文献+
共找到8,734篇文章
< 1 2 250 >
每页显示 20 50 100
Instantaneous frequency measurement using two parallel I/Q modulators based on optical power monitoring 被引量:1
1
作者 王创业 宁提纲 +3 位作者 李晶 裴丽 郑晶晶 张景川 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第1期215-220,共6页
A scheme for instantaneous frequency measurement(IFM)using two parallel I/Q modulators based on optical power monitoring is proposed.The amplitude comparison function(ACF)can be constructed to establish the relationsh... A scheme for instantaneous frequency measurement(IFM)using two parallel I/Q modulators based on optical power monitoring is proposed.The amplitude comparison function(ACF)can be constructed to establish the relationship between the frequency of radio frequency(RF)signal and the power ratio of two optical signals output by two I/Q modulators.The frequency of RF signal can be derived by measuring the optical power of the optical signals output by two I/Q modulators.The measurement range and measurement error can be adjusted by controlling the delay amount of the electrical delay line.The feasibility of the scheme is verified,and the corresponding measurement range and measurement error of the system under different delay amounts of the electrical delay line are given.Compared with previous IFM schemes,the structure of this scheme is simple.Polarization devices,a photodetector and an electrical power meter are not used,which reduces the impact of the environmental disturbance on the system and the cost of the system.In simulation,the measurement range can reach 0 GHz-24.5 GHz by adjusting the delay amount of the electrical delay lineτ=20 ps.The measurement error of the scheme is better at low frequency,and the measurement error of low frequency 0 GHz-9.6 GHz can reach-0.1 GHz to+0.05 GHz. 展开更多
关键词 microwave photonics instantaneous frequency measurement optical power monitoring
下载PDF
罗克韦尔自动化Power Monitor II电力监控器 被引量:1
2
作者 李凤阁 佟为明 林景波 《低压电器》 2003年第6期13-16,33,共5页
介绍了一种集检测、分析、记录、控制、通信于一体的PowerMonitorII电力监控器的结构、功能及相关的监控管理软件 ,和以其为主组成的电力质量管理系统的功能。
关键词 电力系统 电力质量管理系统 电力监控器 powermonitor 罗克韦尔自动化
下载PDF
Design of Millimeter-Wave High-Power Power Monitoring Miter Bend Based on Aperture-Coupling
3
作者 秦龙 赵青 刘述章 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第7期712-715,共4页
A directional coupler in a miter bend was designed to monitor the microwave power of the transmission line in an electron cyclotron resonance heating(ECRH) system. It is based on aperture-coupling theory and simulat... A directional coupler in a miter bend was designed to monitor the microwave power of the transmission line in an electron cyclotron resonance heating(ECRH) system. It is based on aperture-coupling theory and simulation of an electromagnetic(EM) field to design and optimize the 140 GHz high-power directional coupler. In addition, we simulated the double-aperture directional coupler by using three-dimensional(3D) EM simulation software, in which the central frequency is 140 GHz, coupling factor is about –70 dB, and directivity is greater than 17 dB. The results show that such a coupler is a viable tool for power measurement in high-power transmission systems. 展开更多
关键词 ECRH power monitoring aperture-coupling 140 GHz transmission line
下载PDF
Research on Improving the Power Monitor Function
4
作者 Wen Boying (Department of Electronics & Power Engineering The China Agriculture University) Liu Yi (Department of Information Science and Engineering The Liaoning Engineering College) 《Electricity》 2000年第1期48-51,共4页
The contradiction of the relay protection with other task has been solved by double CPU’s structure in this comprehensive monitor. Thus the speed of the data processing has raised and the requirement of relay protect... The contradiction of the relay protection with other task has been solved by double CPU’s structure in this comprehensive monitor. Thus the speed of the data processing has raised and the requirement of relay protection and the real bine monitoring has all been satisfied. The input precision of the fault current and the rated current has been assured respectively by applying the relay protection CT and measurement CT. The algorithm of FFT with or without the difference has remarkably raised the precision of the protective measurement and removed the influence of the attenuation DC component in the fault current. Thus the accuracy and reliability of the protective trigger has been raised greatly. 展开更多
关键词 MICROCOMPUTER RELAY protection FFT algorithm power monitoring COMPREHENSIVE AUTOMATION
下载PDF
Real Time Power Monitoring Detection Based on Sequence Time Domain Reflectometry Approach
5
作者 Sam Moayedi Subhaditya Shom +1 位作者 Andrew Harms Mahmoud Alahmad 《Journal of Computer and Communications》 2018年第1期92-103,共12页
Sequence Time Domain Reflectometry (STDR) have been demonstrated to be a powerful technique for detecting the length of cable or length of open circuit or short circuit cables. Using this method along with using smart... Sequence Time Domain Reflectometry (STDR) have been demonstrated to be a powerful technique for detecting the length of cable or length of open circuit or short circuit cables. Using this method along with using smart meter on the main electrical panel board to monitor consumption if load at each circuit, enable user to monitor power consumption at each node (power outlet) only by operating a smart digital meter and an STDR circuitry on each circuit at the main electrical panel board. This paper introduces this method and examines it on dead-wire and energized wire with a load connected across it. Experimental results are demonstrated for both types. Test result show the potential application of this approach to provide consumption information and potential cost saving via feedback for users. 展开更多
关键词 Wire LENGTH DETECTION SEQUENCE TIME DOMAIN REFLECTOMETRY (STDR) TIME DOMAIN REFLECTOMETRY (TDR) Maximum LENGTH SEQUENCE Coupling power Consumption monitoring
下载PDF
Developing a power monitoring and protection system for the junction boxes of an experimental seafloor observatory network 被引量:6
6
作者 Jun WANG De-jun LI +3 位作者 Can-jun YANG Zhi-feng ZHANG Bo JIN Yan-hu CHEN 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2015年第12期1034-1045,共12页
A power monitoring and protection system based on an embedded processor was designed for the junction boxes(JBs) of an experimental seafloor observatory network in China. The system exhibits high reliability, fast res... A power monitoring and protection system based on an embedded processor was designed for the junction boxes(JBs) of an experimental seafloor observatory network in China. The system exhibits high reliability, fast response, and high real-time performance. A two-step power management method which uses metal-oxide-semiconductor field-effect transistors(MOSFETs) and a mechanical contactor in series was adopted to generate a reliable power switch, to limit surge currents and to facilitate automatic protection. Grounding fault diagnosis and environmental monitoring were conducted by designing a grounding fault detection circuit and by using selected sensors, respectively. The data collected from the JBs must be time-stamped for analysis and for correlation with other events and data. A highly precise system time, which is necessary for synchronizing the times within and across nodes, was generated through the IEEE 1588(precision clock synchronization protocol for networked measurement and control systems) time synchronization method. In this method, time packets were exchanged between the grandmaster clock at the shore station and the slave clock module of the system. All the sections were verified individually in the laboratory prior to a sea trial. Finally, a subsystem for power monitoring and protection was integrated into the complete node system, installed in a frame, and deployed in the South China Sea. Results of the laboratory and sea trial experiments demonstrated that the developed system was effective, stable, reliable, and suitable for continuous deep-sea operation. 展开更多
关键词 power monitoring and protection Embedded processor Seafloor observatory network IEEE 1588 Junction boxes
原文传递
Compact Hybrid Subsystem of 16 Channel Optical Demultiplexer, 2x2 Switches, Optical Power Monitors and Control Circuit
7
作者 Kenichiro Takahashi Toshihiko Kishimoto +5 位作者 Shintaro Mouri Youichi Hata Hideaki Yusa Mitsuaki Tamura Kazuhito Saito Hisao Maki 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期259-260,共2页
A compact hybrid subsystem of 16channel optical demultiplexer, 2x2 switches, optical power monitors and control circuit board is developed. The subsystem is able to add or drop arbitrary optical channels and monitor t... A compact hybrid subsystem of 16channel optical demultiplexer, 2x2 switches, optical power monitors and control circuit board is developed. The subsystem is able to add or drop arbitrary optical channels and monitor the optical power level by software commands. The size of the subsystem is 170x200x30(mm). 展开更多
关键词 of on in have Switches Compact Hybrid Subsystem of 16 Channel Optical Demultiplexer Optical power monitors and Control Circuit
原文传递
Massive Power Device Condition Monitoring Data Feature Extraction and Clustering Analysis using MapReduce and Graph Model 被引量:4
8
作者 Hongtao Shen Peng Tao +1 位作者 Pei Zhao Hao Ma 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第2期221-230,共10页
Effective storage,processing and analyzing of power device condition monitoring data faces enormous challenges.A framework is proposed that can support both MapReduce and Graph for massive monitoring data analysis at ... Effective storage,processing and analyzing of power device condition monitoring data faces enormous challenges.A framework is proposed that can support both MapReduce and Graph for massive monitoring data analysis at the same time based on Aliyun DTplus platform.First,power device condition monitoring data storage based on MaxCompute table and parallel permutation entropy feature extraction based on MaxCompute MapReduce are designed and implemented on DTplus platform.Then,Graph based k-means algorithm is implemented and used for massive condition monitoring data clustering analysis.Finally,performance tests are performed to compare the execution time between serial program and parallel program.Performance is analyzed from CPU cores consumption,memory utilization and parallel granularity.Experimental results show that the designed framework and parallel algorithms can efficiently process massive power device condition monitoring data. 展开更多
关键词 Clustering analysis GRAPH feature extraction MAPREDUCE maxcompute power device condition monitoring.
下载PDF
Monitoring and control technology of solar photovoltaic power generation system 被引量:4
9
作者 Xu Xiaoli Zuo Yunbo Wang Huan 《电子测量与仪器学报》 CSCD 2010年第10期887-891,共5页
In view of characteristics of solar photovoltaic (PV) power station such as the decentralized layout and massive monitoring and control information, a solar PV power generation monitoring and control system has been d... In view of characteristics of solar photovoltaic (PV) power station such as the decentralized layout and massive monitoring and control information, a solar PV power generation monitoring and control system has been designed. The system is designed into three layers namely the sensor and actuator layer, the PLC field monitoring and control layer and the remote network monitoring and control layer. Through ZigBee wireless network, PROFIBUS and GPRS wireless network, the system makes the three layers exchange information rapidly, and the system supervises not only various operational parameters of the power generating system but also weather changes as a way to change the solar tracking strategy of the PV power generating system and reduce the operating energy consumption of the system. Through the hardware redundant design of PLC central controller and the upper computer, the solar PV power station can be more secure and reliable when running. 展开更多
关键词 计算机 网络监控 控制技术 光电功率
下载PDF
Compliance verification and probabilistic analysis of state-wide power quality monitoring data 被引量:7
10
作者 Liu Yang Jiang Peng +4 位作者 Tongxun Wang Yaqiong Li Zhanfeng Deng Yingying Liu Meng Tan 《Global Energy Interconnection》 2018年第3期391-395,共5页
This paper introduces the implementation and data analysis associated with a state-wide power quality monitoring and analysis system in China. Corporation specifications on power quality monitors as well as on communi... This paper introduces the implementation and data analysis associated with a state-wide power quality monitoring and analysis system in China. Corporation specifications on power quality monitors as well as on communication protocols are formulated for data transmission. Big data platform and related technologies are utilized for data storage and computation. Compliance verification analysis and a power quality performance assessment are conducted, and a visualization tool for result presentation is finally presented. 展开更多
关键词 power quality monitoring Big data HADOOP Compliance verification
下载PDF
Power Line Monitoring Data Transmission Using Wireless Sensor Network 被引量:4
11
作者 Lifen Li Huaiyu Zhao 《Journal of Power and Energy Engineering》 2015年第8期83-88,共6页
The WSN used in power line monitoring is long chain structure, and the bottleneck near the Sink node is more obvious. In view of this, A Sink nodes’ cooperation mechanism is presented. The Sink nodes from different W... The WSN used in power line monitoring is long chain structure, and the bottleneck near the Sink node is more obvious. In view of this, A Sink nodes’ cooperation mechanism is presented. The Sink nodes from different WSNs are adjacently deployed. Adopting multimode and spatial multiplexing network technology, the network is constructed into multi-mode-level to achieve different levels of data streaming. The network loads are shunted and the network resources are rationally utilized. Through the multi-sink nodes cooperation, the bottlenecks at the Sink node and its near several jump nodes are solved and process the competition of communication between nodes by channel adjustment. Finally, the paper analyzed the method and provided simulation experiment results. Simulation results show that the method can solve the funnel effect of the sink node, and get a good QoS. 展开更多
关键词 WIRELESS Sensor NETWORK (WSN) power Line monitoring Data TRANSMISSION MULTIMODE NETWORK
下载PDF
A Remote Real-Time Monitoring System for Power Quality 被引量:1
12
作者 黄治清 贺建闽 《Journal of Southwest Jiaotong University(English Edition)》 2003年第1期31-38,共8页
An introduction is made to the composition, design method and engineering application of a remote real time monitoring system of power quality in substations based on internet. With virtual instrument and network tec... An introduction is made to the composition, design method and engineering application of a remote real time monitoring system of power quality in substations based on internet. With virtual instrument and network technique adopted, this system is characterized by good real time property, high reliability, plentiful functions, and so on. It also can be used to monitor the load of a substation, such as electric locomotives. 展开更多
关键词 power quality remote monitoring real time monitoring system virtual instrument
下载PDF
A power-quality monitoring and assessment system for high-speed railways based on train-network-data center integration
13
作者 Jun Zhu Haitao Hu +2 位作者 Zhengyou He Xiaomin Guo Weiguo Pan 《Railway Engineering Science》 2021年第1期30-41,共12页
In recent years,with the rapid development of high-speed railways(HSRs),power interruptions or disturbances in traction power supply systems have become increasingly dangerous.However,it is often impossible to detect ... In recent years,with the rapid development of high-speed railways(HSRs),power interruptions or disturbances in traction power supply systems have become increasingly dangerous.However,it is often impossible to detect these faults immediately through single-point monitoring or collecting data after accidents.To coordinate the power quality data of both traction power supply systems(TPSSs)and high-speed trains(HSTs),a monitoring and assessing system is proposed to access the power quality issues on HSRs.By integrating train monitoring,traction substation monitoring and data center,this monitoring system not only realizes the real-time monitoring of operational behaviors for both TPSSs and HSTs,but also conducts a comprehensive assessment of operational quality for train-network systems.Based on a large number of monitoring data,the field measurements show that this real-time monitoring system is effective for monitoring and evaluating a traction-network system. 展开更多
关键词 High-speed railway Traction power supply system power quality monitoring Data center
下载PDF
基于Power BI软件对集采药品的智能监测与管理 被引量:1
14
作者 李雅琴 薛维佳 +3 位作者 王芳芳 朱炜炜 蒙婷 李里 《中国药业》 CAS 2023年第11期13-17,共5页
目的提高国家组织药品集中采购、省际联盟带量采购药品(简称集采药品)工作监控管理的智能化水平。方法基于Power BI软件开发可视化智能监控工具,获取并整理数据,运用M函数与度量值对数据建模分析,添加视觉对象生成交互式可视化报表。结... 目的提高国家组织药品集中采购、省际联盟带量采购药品(简称集采药品)工作监控管理的智能化水平。方法基于Power BI软件开发可视化智能监控工具,获取并整理数据,运用M函数与度量值对数据建模分析,添加视觉对象生成交互式可视化报表。结果基于Power BI软件自主设计集采药品智能监控系统实现了以集采药品为业务场景的多维分析,可快速获取集采药品的合同量完成情况、中选与非中选药品采购量占比、采购金额占比等重要指标。结论Power BI软件可为医院集采药品的管理提供强大的技术支持,并可实现数据使用规范化、统计分析智能化、数据呈现可视化。 展开更多
关键词 集采药品 power BI软件 药品管理 智能监控
下载PDF
PMU Based Monitoring and Estimation of Inter-area Power Oscillation for Singapore-Malaysia Interconnection Power System 被引量:2
15
作者 Dikpride Despa Yasunori Mitani +1 位作者 Masayuki Watanabe Changsong Li 《Journal of Energy and Power Engineering》 2012年第3期463-468,共6页
关键词 互联电力系统 马来西亚 功率振荡 新加坡 PMU 监测 估计 系统区域
下载PDF
Analog-experiment analysis of ash-deposition monitoring model of boiler economizers in power plants
16
作者 程伟良 夏国栋 徐寿臣 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2005年第6期680-683,共4页
Ash deposition is a form of particulate fouling, and appears usually in boiler economizers. The ash deposition increases capital expenditure, energy input and maintenance costs. An analog experiment for monitoring ash... Ash deposition is a form of particulate fouling, and appears usually in boiler economizers. The ash deposition increases capital expenditure, energy input and maintenance costs. An analog experiment for monitoring ash deposition was performed from the analogous objective of a 410 t/h boiler economizer to verify the rationality and reliability of the ash-deposition-monitoring model presented in order to increase the security and economy in economizer running. The analog experiment platform is a tube-shell exchanger that conforms well to the conditions of a self-modeling area. The analog flue gas in the shell side is the heated air mixed with ash, and in the tube side the fluid is water heated by the flue gas. The fluid state in the water side and the flue gas side follows the second self-modeling area. A 4-factor-3-level orthogonal table was used to schedule 9 operation conditions of orthogonal experiment, with the 4 factors being heat power, flue gas velocity, ashes grain diameter and adding ashes quantity while the three levels are different values due to different position classes in every factor. The ash deposition thermal resistances is calculated by the model with the measure parameters of temperature and pressure drop. It shows that the values of the ash deposition thermal resistances gradually increase up to a stable state. And the experimental results are reliable by F testing method at α= 0.001. Therefore, the model can be applied in online monitoring of ash deposition in a boiler economizers in power plants and provides scientific decision on ash deposition prediction and sootblowing. 展开更多
关键词 热电工程 发电厂 除灰 监控系统 锅炉省煤器 管壳换热器
下载PDF
BP-Neural-Network-Based Tool Wear Monitoring by Using Wav elet Decomposition of the Power Spectrum 被引量:1
17
作者 ZHENGJian-ming XIChang-qing +1 位作者 LIYan XIAOJi-ming 《International Journal of Plant Engineering and Management》 2004年第4期198-204,共7页
In a drilling process, the power spectrum of the drilling force is related tothe tool wear and is widely applied in the monitoring of tool wear. But the feature extraction andidentification of the power spectrum have ... In a drilling process, the power spectrum of the drilling force is related tothe tool wear and is widely applied in the monitoring of tool wear. But the feature extraction andidentification of the power spectrum have always been an unresolved difficult problem. This papersolves it through decomposition of the power spectrum in multilayers using wavelet transform andextraction of the low frequency decomposition coefficient as the envelope information of the powerspectrum. Intelligent identification of the tool wear status is achieved in the drilling processthrough fusing the wavelet decomposition coefficient of the power spectrum by using a BP (BackPropagation) neural network. The experimental results show that the features of the power spectrumcan be extracted efficiently through this method, and the trained neural networks show highidentification precision and the ability of extension. 展开更多
关键词 tool wear monitoring power spectrum wavelet transform BP neural network
下载PDF
Radiological monitoring results of the ambient environment around Qinshan Nuclear Power Plant
18
作者 ZHANGRong-Suo ZENGGuang-Jian JIANGRang-Rong YEJi-Da XIANGYuan-Yi HUANGRen-Jie CAOZhong-Gang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2004年第1期59-64,共6页
A plan of surveillance monitoring Qinshan Nuclear Power Plant (QNPP) has been implemented since 1992, the objective of which is to establish the database of environmental radiation information around QNPP, and to dete... A plan of surveillance monitoring Qinshan Nuclear Power Plant (QNPP) has been implemented since 1992, the objective of which is to establish the database of environmental radiation information around QNPP, and to detect any unplanned discharge of radioactive materials from QNPP. This paper presents the monitoring results for radionuclide concentrations in the environmental matrices before and after QNPP operation. The radionuclide con- centrations in vegetation, food, atmosphere, soil and littoral soil samples have been determined. After operation of QNPP, the mean values of 137Cs, Sr and H in water are 0.6, 4.9 mBq/L and 1.7 Bq/L, respectively; the mean values 90 3 of137Cs in soil and littoral soil are 3.5 and 2.7 Bq/kg, respectively; the mean values of137Cs in rice, green cabbage, meat, mullet, milk and tea are 0.033, 0.039, 0.081, 0.069, 0.018 and 0.62 Bq/kg, respectively; the mean values of 90 Sr in rice, green cabbage and tea are 0.081, 0.315 and 4.1 Bq/kg, respectively; gross β activity in fallout is 0.9 Bq·m-2·d-1. Compared with the data before QNPP’s operation, no significant difference has heen observed in the radioactivity of137Cs, Sr, H and the gross β activity in ambient environmental matrices from 1992 to 2001, and 90 3 there are only some fluctuations within the range of background. 展开更多
关键词 辐射监测 秦山核电站 QNPP 环境污染 辐射防护
下载PDF
Monitoring of Power Transmission as Constraint Management in TSOs' Operations 被引量:1
19
作者 Jean Constantinescu Nicholas Harkiolakis Daniela Bolborici 《通讯和计算机(中英文版)》 2012年第3期335-339,共5页
关键词 约束管理 电力系统调度 输电 监测 传输系统 安全性分析 自动调度 电力市场
下载PDF
STUDY ON REALISTIC TECHNOLOGY OF CONDITION MONITORING AND FAULT DIAGNOSTIC SYSTEM FOR SHIPPING POWER DEVICES
20
作者 温熙森 李岳 《国防科技大学学报》 EI CAS CSCD 北大核心 1995年第3期26-32,共7页
STUDYONREALISTICTECHNOLOGYOFCONDITIONMONITORINGANDFAULTDIAGNOSTICSYSTEMFORSHIPPINGPOWERDEVICESWenXisen;LiYue... STUDYONREALISTICTECHNOLOGYOFCONDITIONMONITORINGANDFAULTDIAGNOSTICSYSTEMFORSHIPPINGPOWERDEVICESWenXisen;LiYue;TangBingyang(Dep... 展开更多
关键词 状态监测 故障诊断 轮船 动力装置
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部