In order to improve the energy efficiency, reduce the CO2 emission and decrease the cost, a cogenera- tion system for desalination water, heat and power production was studied in this paper. The superstructure of the ...In order to improve the energy efficiency, reduce the CO2 emission and decrease the cost, a cogenera- tion system for desalination water, heat and power production was studied in this paper. The superstructure of the cogeneration system consisted of a coal-based thermal power plant (TPP), a multi-stage flash desalination (MSF) module and reverse osmosis desalination (RO) module. For different demands of water, heat and power production, the corresponding optimal production structure was different. After reasonable simplification, the process model ot each unit was built. The economical model, including the unit investment, and operation and maintenance cost, was presented. By solving this non-linear programming (NLP) model, whose objective is to minimize the annual cost, an optimal cogeneration system can be obtained. Compared to separate production systems, the optimal system can reduce 16.1%-21.7% of the total annual cost. showing this design method was effective.展开更多
In recent years,relevant government departments have achieved the goal of reduction and harmless application through the development and implementation of municipal waste incineration power plants,in order to advocate...In recent years,relevant government departments have achieved the goal of reduction and harmless application through the development and implementation of municipal waste incineration power plants,in order to advocate ecological and environmental protection.At present,in order to further achieve the goal of sustainable development,municipal waste incineration power plants have actively responded to the national call and requirements as well as made overall arrangements for the energy-saving design and optimization design of their internal system.Therefore,with the concept of sustainable development,this paper studies and analyzes the problems of the HVAC design as well as suggests related strategies for municipal waste incineration power plants in order to provide relevant reference.展开更多
The complementary of biomass and solar energy in combined cooling,heating and power(CCHP)system provides an efficient solution to address the energy crisis and environmental pollutants.This work aims to propose a mult...The complementary of biomass and solar energy in combined cooling,heating and power(CCHP)system provides an efficient solution to address the energy crisis and environmental pollutants.This work aims to propose a multi-objective optimization model based on the life cycle assessment(LCA)method for the optimal design of hybrid solar and biomass system.The life-cycle process of the poly-generation system is divided into six phases to analyze energy consumption and greenhouse gas emissions.The comprehensive performances of the hybrid system are optimized by incorporating the evaluation criteria,including environmental impact in the whole life cycle,renewable energy contribution and economic benefit.The non-dominated sorting genetic algorithmⅡ(NSGA-Ⅱ)with the technique for order preference by similarity to ideal solution(TOPSIS)method is employed to search the Pareto frontier result and thereby achieve optimal performance.The developed optimization methodology is used for a case study in an industrial park.The results indicate that the best performance from the optimized hybrid system is reached with the environmental impact load reduction rate(EILRR)of 46.03%,renewable energy contribution proportion(RECP)of 92.73%and annual total cost saving rate(ATCSR)of35.75%,respectively.By comparing pollutant-eq emissions of different stages,the operation phase emits the largest pollutant followed by the phase of raw material acquisition.Overall,this study reveals that the proposed multi-objective optimization model integrated with LCA method delivers an alternative path for the design and optimization of more sustainable CCHP system.展开更多
The supercritical CO_(2)(S-CO_(2)) Brayton cycle is expected to replace steam cycle in the application of solar power tower system due to the attractive potential to improve efficiency and reduce costs.Since the conce...The supercritical CO_(2)(S-CO_(2)) Brayton cycle is expected to replace steam cycle in the application of solar power tower system due to the attractive potential to improve efficiency and reduce costs.Since the concentrated solar power plant with thermal energy storage is usually located in drought area and used to provide a dispatchable power output,the S-CO_(2) Brayton cycle has to operate under fluctuating ambient temperature and diverse power demand scenarios.In addition,the cycle design condition will directly affect the off-design performance.In this work,the combined effects of design condition,and distributions of ambient temperature and power demand on the cycle operating performance are analyzed,and the off-design performance maps are proposed for the first time.A cycle design method with feedback mechanism of operating performance under varied ambient temperature and power demand is introduced innovatively.Results show that the low design value of compressor inlet temperature is not conductive to efficient operation under low loads and sufficient output under high ambient temperatures.The average yearly efficiency is most affected by the average power demand,while the load cover factor is significantly influenced by the average ambient temperature.With multi-objective optimization,the optimal solution of designed compressor inlet temperature is close to the minimum value of35℃ in Delingha with low ambient temperature,while reaches 44.15℃ in Daggett under the scenario of high ambient temperature,low average power demand,long duration and large value of peak load during the peak temperature period.If the cycle designed with compressor inlet temperature of 35℃ instead of 44.15℃ in Daggett under light industry power demand,the reduction of load cover factor will reach 0.027,but the average yearly efficiency can barely be improved.展开更多
基金Supported by the National Natural Science Foundation of China(21076202)
文摘In order to improve the energy efficiency, reduce the CO2 emission and decrease the cost, a cogenera- tion system for desalination water, heat and power production was studied in this paper. The superstructure of the cogeneration system consisted of a coal-based thermal power plant (TPP), a multi-stage flash desalination (MSF) module and reverse osmosis desalination (RO) module. For different demands of water, heat and power production, the corresponding optimal production structure was different. After reasonable simplification, the process model ot each unit was built. The economical model, including the unit investment, and operation and maintenance cost, was presented. By solving this non-linear programming (NLP) model, whose objective is to minimize the annual cost, an optimal cogeneration system can be obtained. Compared to separate production systems, the optimal system can reduce 16.1%-21.7% of the total annual cost. showing this design method was effective.
文摘In recent years,relevant government departments have achieved the goal of reduction and harmless application through the development and implementation of municipal waste incineration power plants,in order to advocate ecological and environmental protection.At present,in order to further achieve the goal of sustainable development,municipal waste incineration power plants have actively responded to the national call and requirements as well as made overall arrangements for the energy-saving design and optimization design of their internal system.Therefore,with the concept of sustainable development,this paper studies and analyzes the problems of the HVAC design as well as suggests related strategies for municipal waste incineration power plants in order to provide relevant reference.
基金supported by the National Natural Science Foundation of China(Grant No.51976164)。
文摘The complementary of biomass and solar energy in combined cooling,heating and power(CCHP)system provides an efficient solution to address the energy crisis and environmental pollutants.This work aims to propose a multi-objective optimization model based on the life cycle assessment(LCA)method for the optimal design of hybrid solar and biomass system.The life-cycle process of the poly-generation system is divided into six phases to analyze energy consumption and greenhouse gas emissions.The comprehensive performances of the hybrid system are optimized by incorporating the evaluation criteria,including environmental impact in the whole life cycle,renewable energy contribution and economic benefit.The non-dominated sorting genetic algorithmⅡ(NSGA-Ⅱ)with the technique for order preference by similarity to ideal solution(TOPSIS)method is employed to search the Pareto frontier result and thereby achieve optimal performance.The developed optimization methodology is used for a case study in an industrial park.The results indicate that the best performance from the optimized hybrid system is reached with the environmental impact load reduction rate(EILRR)of 46.03%,renewable energy contribution proportion(RECP)of 92.73%and annual total cost saving rate(ATCSR)of35.75%,respectively.By comparing pollutant-eq emissions of different stages,the operation phase emits the largest pollutant followed by the phase of raw material acquisition.Overall,this study reveals that the proposed multi-objective optimization model integrated with LCA method delivers an alternative path for the design and optimization of more sustainable CCHP system.
基金supported by Beijing Natural Science Foundation (Grant No.3202014)。
文摘The supercritical CO_(2)(S-CO_(2)) Brayton cycle is expected to replace steam cycle in the application of solar power tower system due to the attractive potential to improve efficiency and reduce costs.Since the concentrated solar power plant with thermal energy storage is usually located in drought area and used to provide a dispatchable power output,the S-CO_(2) Brayton cycle has to operate under fluctuating ambient temperature and diverse power demand scenarios.In addition,the cycle design condition will directly affect the off-design performance.In this work,the combined effects of design condition,and distributions of ambient temperature and power demand on the cycle operating performance are analyzed,and the off-design performance maps are proposed for the first time.A cycle design method with feedback mechanism of operating performance under varied ambient temperature and power demand is introduced innovatively.Results show that the low design value of compressor inlet temperature is not conductive to efficient operation under low loads and sufficient output under high ambient temperatures.The average yearly efficiency is most affected by the average power demand,while the load cover factor is significantly influenced by the average ambient temperature.With multi-objective optimization,the optimal solution of designed compressor inlet temperature is close to the minimum value of35℃ in Delingha with low ambient temperature,while reaches 44.15℃ in Daggett under the scenario of high ambient temperature,low average power demand,long duration and large value of peak load during the peak temperature period.If the cycle designed with compressor inlet temperature of 35℃ instead of 44.15℃ in Daggett under light industry power demand,the reduction of load cover factor will reach 0.027,but the average yearly efficiency can barely be improved.