This paper presents a current control method for a shunt hybrid active power filter (HAPF) using recursive integral PI algorithm. The method improves the performance of the HAPF system by reducing the influence of d...This paper presents a current control method for a shunt hybrid active power filter (HAPF) using recursive integral PI algorithm. The method improves the performance of the HAPF system by reducing the influence of detection accuracy, time delay of instruction current calculation and phase displacement of output filter. Fuzzy logic based set-point weighing algorithm is combined in the control scheme to enhance its robustness and anti-interference ability. The proposed algorithm is easy to implement for engineering applications and easy to compute. Experiment results have verified the validity of the proposed controller. Furthermore, the proposed recursive integral PI algorithm can also be applied in the control of periodic current as in AC drivers.展开更多
A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous...A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous reactive power theory based algorithm was unsatisfactory in terms of isolating positive sequence fundamental active components exactly under non-ideal mains voltages. So, a modified ip-iq reference current calculation method was presented. With usage of the new method, not only the positive sequence but also the fundamental active current components can be accurately isolated from load current. A deadbeat closed-loop control model is built in order to eliminate both delay error and tracking error between reference voltages and compensation voltages under unbalanced and distorted mains voltages. Computer simulation results show that the proposed strategy is effective with better tracking ability and lower total harmonic distortion (THD). The strategy is also applied to a 10 kV substation with a local electrolysis manganese plant injecting a large amount of harmonics into the power system, and is proved to be more practical and efficient.展开更多
The open-circuit fault of the power switches in shunt active power filter(SAPF) would exacerbate the harmonic pollution of power grid, and degrade the reliability of the devices and system. A fault diagnosis method is...The open-circuit fault of the power switches in shunt active power filter(SAPF) would exacerbate the harmonic pollution of power grid, and degrade the reliability of the devices and system. A fault diagnosis method is proposed based on reference model and an over-modulation strategy under hardware fault tolerance for SAPF. First, a mathematic model is established for SAPF. Second, the residuals are generated by comparing the outputs of reference model and those of actual model, and open-switch fault is detected and diagnosed by residual evaluation. After that, hardware fault tolerance is performed with the three-phase four-switch(TPFS) topology to isolate the faulty phase. Finally, the over-modulation strategy is proposed to increase the voltage transfer ratio of the TPFS topology. Simulation and experimental results verified the feasibility and effectiveness of the proposed method.展开更多
This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Opt...This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Optimization (PSO) and conventional Proportional Integral (PI) controller are used as control techniques to analyze the control performance of 4-leg shunt active power filter. The synchronous reference frame (SRF) method is used to extract reference current in 4-leg shunt active filter. The Hysteresis Current Controller (HCC) is used to generate gate pulses for Voltage Source Inverter (VSI) based 4-leg shunt active power filter. The proposed PSO technique gives less percentage of Total Harmonic Distortion (THD) value in source and neutral current and settling time of the DC capacitor voltage compared to conventional PI controller technique. The model of the proposed system performance was validated using MATLAB/Simulink environment.展开更多
Due to environmental conditions, the wind power generation is fluctuating in nature. This affects the electrical network interconnected with these systems. When the wind power generators are connected to the nonlinear...Due to environmental conditions, the wind power generation is fluctuating in nature. This affects the electrical network interconnected with these systems. When the wind power generators are connected to the nonlinear loads, there is distortion in the waveform. These distortions should be within limits according to national and international guidelines framed for power quality. This paper presents a mitigation technique with a shunt active filter, which reduces harmonic distortion to the permitted limit. Sine pulse width modulation (SPWM) control scheme is used to control shunt active filter. This technique eliminates harmonic distortion and maintains unity power factor. The simulation for proposed method is carried out using MATLAB/SIMULINK and results are validated.展开更多
This paper presents a fuzzy logic based three phase four wire four-leg shunt active power filter to suppress harmonic currents. Modified instantaneous p-q theory is adopted for calculating the compensating current. Fu...This paper presents a fuzzy logic based three phase four wire four-leg shunt active power filter to suppress harmonic currents. Modified instantaneous p-q theory is adopted for calculating the compensating current. Fuzzy-adaptive hysteresis band technique is applied for the current control to derive the switching signals for the voltage source inverter. A fuzzy logic controller is developed to control the voltage of the DC capacitor. Computer simulations are carried out on a sample power system to demonstrate the suitability of the proposed control strategy, for harmonic reduction under three different conditions namely, ideal, unbalance, unbalance and distorted source voltage conditions. The proposed control strategy is found to be effective to reduce the harmonics and compensate reactive power and neutral current and balance load currents under ideal and non-ideal source voltage conditions.展开更多
This paper first discusses the operating principle of instantaneous reactive power theory. Then, the theory is introduced into shunt active power filter and its control scheme is studied. Finally, Matlab/Simulink powe...This paper first discusses the operating principle of instantaneous reactive power theory. Then, the theory is introduced into shunt active power filter and its control scheme is studied. Finally, Matlab/Simulink power system toolbox is used to simulate the system. In the simulation model, as the most common harmonic source, 3-phase thyristor bridge rectifier circuit is constructed. The simulation results before and after the shunt active filter was switched to the system corresponding to different firing angles of the thyristors are presented and analyzed, which demonstrate the practicability and reliability of the proposed shunt active filter scheme.展开更多
Due to development of distribution systems and increase in electricity demand,the use of capacitor banks increases.From the other point of view,nonlinear loads generate and inject considerable harmonic currents into p...Due to development of distribution systems and increase in electricity demand,the use of capacitor banks increases.From the other point of view,nonlinear loads generate and inject considerable harmonic currents into power system.Under this condition if capacitor banks are not properly selected and placed in the power system,they could amplify and propagate these harmonics and deteriorate power quality to unacceptable levels.With attention of disadvantages of passive filters,such as occurring resonance,nowadays the usage of this type of harmonic compensator is restricted.On the other side,one of parallel multi-function compensating devices which are recently used in distribution system to mitigate voltage sag and harmonic distortion,performs power factor correction,and improves the overall power quality as active power conditioner(APC).Therefore,the utilization of APC in harmonic distorted system can affect and change the optimal location and size of shunt capacitor bank under harmonic distortion condition.This paper presents an optimization algorithm for improvement of power quality using simultaneous optimal placement and sizing of APC and shunt capacitor banks in radial distribution networks in the presence of voltage and current harmonics.The algorithm is based on particle swarm optimization(PSO).The objective function includes the cost of power losses,energy losses and those of the capacitor banks and APCs.展开更多
基金supported by the National Natural Science Foundation of China (No.60774043)
文摘This paper presents a current control method for a shunt hybrid active power filter (HAPF) using recursive integral PI algorithm. The method improves the performance of the HAPF system by reducing the influence of detection accuracy, time delay of instruction current calculation and phase displacement of output filter. Fuzzy logic based set-point weighing algorithm is combined in the control scheme to enhance its robustness and anti-interference ability. The proposed algorithm is easy to implement for engineering applications and easy to compute. Experiment results have verified the validity of the proposed controller. Furthermore, the proposed recursive integral PI algorithm can also be applied in the control of periodic current as in AC drivers.
基金Project(JC200903180555A) supported by Shenzhen City Science and Technology Plan, China
文摘A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous reactive power theory based algorithm was unsatisfactory in terms of isolating positive sequence fundamental active components exactly under non-ideal mains voltages. So, a modified ip-iq reference current calculation method was presented. With usage of the new method, not only the positive sequence but also the fundamental active current components can be accurately isolated from load current. A deadbeat closed-loop control model is built in order to eliminate both delay error and tracking error between reference voltages and compensation voltages under unbalanced and distorted mains voltages. Computer simulation results show that the proposed strategy is effective with better tracking ability and lower total harmonic distortion (THD). The strategy is also applied to a 10 kV substation with a local electrolysis manganese plant injecting a large amount of harmonics into the power system, and is proved to be more practical and efficient.
基金Project(2012AA051601)supported by the High-Tech Research and Development Program of China
文摘The open-circuit fault of the power switches in shunt active power filter(SAPF) would exacerbate the harmonic pollution of power grid, and degrade the reliability of the devices and system. A fault diagnosis method is proposed based on reference model and an over-modulation strategy under hardware fault tolerance for SAPF. First, a mathematic model is established for SAPF. Second, the residuals are generated by comparing the outputs of reference model and those of actual model, and open-switch fault is detected and diagnosed by residual evaluation. After that, hardware fault tolerance is performed with the three-phase four-switch(TPFS) topology to isolate the faulty phase. Finally, the over-modulation strategy is proposed to increase the voltage transfer ratio of the TPFS topology. Simulation and experimental results verified the feasibility and effectiveness of the proposed method.
文摘This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Optimization (PSO) and conventional Proportional Integral (PI) controller are used as control techniques to analyze the control performance of 4-leg shunt active power filter. The synchronous reference frame (SRF) method is used to extract reference current in 4-leg shunt active filter. The Hysteresis Current Controller (HCC) is used to generate gate pulses for Voltage Source Inverter (VSI) based 4-leg shunt active power filter. The proposed PSO technique gives less percentage of Total Harmonic Distortion (THD) value in source and neutral current and settling time of the DC capacitor voltage compared to conventional PI controller technique. The model of the proposed system performance was validated using MATLAB/Simulink environment.
文摘Due to environmental conditions, the wind power generation is fluctuating in nature. This affects the electrical network interconnected with these systems. When the wind power generators are connected to the nonlinear loads, there is distortion in the waveform. These distortions should be within limits according to national and international guidelines framed for power quality. This paper presents a mitigation technique with a shunt active filter, which reduces harmonic distortion to the permitted limit. Sine pulse width modulation (SPWM) control scheme is used to control shunt active filter. This technique eliminates harmonic distortion and maintains unity power factor. The simulation for proposed method is carried out using MATLAB/SIMULINK and results are validated.
文摘This paper presents a fuzzy logic based three phase four wire four-leg shunt active power filter to suppress harmonic currents. Modified instantaneous p-q theory is adopted for calculating the compensating current. Fuzzy-adaptive hysteresis band technique is applied for the current control to derive the switching signals for the voltage source inverter. A fuzzy logic controller is developed to control the voltage of the DC capacitor. Computer simulations are carried out on a sample power system to demonstrate the suitability of the proposed control strategy, for harmonic reduction under three different conditions namely, ideal, unbalance, unbalance and distorted source voltage conditions. The proposed control strategy is found to be effective to reduce the harmonics and compensate reactive power and neutral current and balance load currents under ideal and non-ideal source voltage conditions.
文摘This paper first discusses the operating principle of instantaneous reactive power theory. Then, the theory is introduced into shunt active power filter and its control scheme is studied. Finally, Matlab/Simulink power system toolbox is used to simulate the system. In the simulation model, as the most common harmonic source, 3-phase thyristor bridge rectifier circuit is constructed. The simulation results before and after the shunt active filter was switched to the system corresponding to different firing angles of the thyristors are presented and analyzed, which demonstrate the practicability and reliability of the proposed shunt active filter scheme.
文摘Due to development of distribution systems and increase in electricity demand,the use of capacitor banks increases.From the other point of view,nonlinear loads generate and inject considerable harmonic currents into power system.Under this condition if capacitor banks are not properly selected and placed in the power system,they could amplify and propagate these harmonics and deteriorate power quality to unacceptable levels.With attention of disadvantages of passive filters,such as occurring resonance,nowadays the usage of this type of harmonic compensator is restricted.On the other side,one of parallel multi-function compensating devices which are recently used in distribution system to mitigate voltage sag and harmonic distortion,performs power factor correction,and improves the overall power quality as active power conditioner(APC).Therefore,the utilization of APC in harmonic distorted system can affect and change the optimal location and size of shunt capacitor bank under harmonic distortion condition.This paper presents an optimization algorithm for improvement of power quality using simultaneous optimal placement and sizing of APC and shunt capacitor banks in radial distribution networks in the presence of voltage and current harmonics.The algorithm is based on particle swarm optimization(PSO).The objective function includes the cost of power losses,energy losses and those of the capacitor banks and APCs.