期刊文献+
共找到12,369篇文章
< 1 2 250 >
每页显示 20 50 100
Simulation of Underground Reservoir Stability of Pumped Storage Power Station Based on Fluid-Structure Coupling
1
作者 Peng Qiao Shuangshuang Lan +1 位作者 Hongbiao Gu Zhengtan Mao 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第5期1381-1399,共19页
Based on global initiatives such as the clean energy transition and the development of renewable energy,the pumped storage power station has become a new and significant way of energy storage and regulation,and its co... Based on global initiatives such as the clean energy transition and the development of renewable energy,the pumped storage power station has become a new and significant way of energy storage and regulation,and its construction environment is more complex than that of a traditional reservoir.In particular,the stability of the rock strata in the underground reservoirs is affected by the seepage pressure and rock stress,which presents some challenges in achieving engineering safety and stability.Using the advantages of the numerical simulation method in dealing deal with nonlinear problems in engineering stability,in this study,the stability of the underground reservoir of the Shidangshan(SDS)pumped storage power station was numerically calculated and quantitatively analyzed based on fluid-structure coupling theory,providing an important reference for the safe operation and management of the underground reservoir.First,using the COMSOL software,a suitablemechanicalmodel was created in accordance with the geological structure and project characteristics of the underground reservoir.Next,the characteristics of the stress field,displacement field,and seepage field after excavation of the underground reservoir were simulated in light of the seepage effect of groundwater on the nearby rock of the underground reservoir.Finally,based on the construction specifications and Molar-Coulomb criterion,a thorough evaluation of the stability of the underground reservoir was performed through simulation of the filling and discharge conditions and anti-seepage strengthening measures.The findings demonstrate that the numerical simulation results have a certain level of reliability and are in accordance with the stress measured in the project area.The underground reservoir excavation resulted in a maximum displacement value of the rock mass around the caverns of 3.56 mm in a typical section,and the safety coefficient of the parts,as determined using the Molar-Coulomb criterion,was higher than 1,indicating that the project as a whole is in a stable state. 展开更多
关键词 Underground reservoir fluid-structure coupling numerical simulation pumped storage power station filling and discharge
下载PDF
Multimodel Ensemble Forecast of Global Horizontal Irradiance at PV Power Stations Based on Dynamic Variable Weight
2
作者 YUAN Bin SHEN Yan-bo +6 位作者 DENG Hua YANG Yang CHEN Qi-ying YE Dong MO Jing-yue YAO Jin-feng LIU Zong-hui 《Journal of Tropical Meteorology》 SCIE 2024年第3期327-336,共10页
In the present study,multimodel ensemble forecast experiments of the global horizontal irradiance(GHI)were conducted using the dynamic variable weight technique.The study was based on the forecasts of four numerical m... In the present study,multimodel ensemble forecast experiments of the global horizontal irradiance(GHI)were conducted using the dynamic variable weight technique.The study was based on the forecasts of four numerical models,namely,the China Meteorological Administration Wind Energy and Solar Energy Prediction System,the Mesoscale Weather Numerical Prediction System of China Meteorological Administration,the China Meteorological Administration Regional Mesoscale Numerical Prediction System-Guangdong,and the Weather Research and Forecasting Model-Solar,and observational data from four photovoltaic(PV)power stations in Yangjiang City,Guangdong Province.The results show that compared with those of the monthly optimal numerical model forecasts,the dynamic variable weight-based ensemble forecasts exhibited 0.97%-15.96%smaller values of the mean absolute error and 3.31%-18.40%lower values of the root mean square error(RMSE).However,the increase in the correlation coefficient was not obvious.Specifically,the multimodel ensemble mainly improved the performance of GHI forecasts below 700 W m^(-2),particularly below 400 W m^(-2),with RMSE reductions as high as 7.56%-28.28%.In contrast,the RMSE increased at GHI levels above 700 W m^(-2).As for the key period of PV power station output(02:00-07:00),the accuracy of GHI forecasts could be improved by the multimodel ensemble:the multimodel ensemble could effectively decrease the daily maximum absolute error(AE max)of GHI forecasts.Moreover,with increasing forecasting difficulty under cloudy conditions,the multimodel ensemble,which yields data closer to the actual observations,could simulate GHI fluctuations more accurately. 展开更多
关键词 GHI forecast multimodel ensemble dynamic variable weight PV power station
下载PDF
Solar Energy Resource Characteristics of Photovoltaic Power Station in Shandong Province 被引量:2
3
作者 薛德强 王新 王新堂 《Agricultural Science & Technology》 CAS 2013年第4期666-671,共6页
[Objective] The aim was to analyze characters of solar energy in photo- voltaic power stations in Shandong Province. [Method] The models of total solar radiation and scattered radiation were determined, and solar ener... [Objective] The aim was to analyze characters of solar energy in photo- voltaic power stations in Shandong Province. [Method] The models of total solar radiation and scattered radiation were determined, and solar energy resources in pho-tovoltaic power stations were evaluated based on illumination in horizontal plane and cloud data in 123 counties or cities and observed information in Jinan, Fushan and Juxian in 1988-2008. [Result] Solar energy in northern regions in Shandong proved most abundant, which is suitable for photovoltaic power generation; the optimal angle of tilt of photovoltaic array was at 35°, decreasing by 2°-3° compared with local latitude. Total solar radiation received by the slope with optimal angle of tilt exceeded 1 600 kw.h/(m2.a), increasing by 16% compared with horizontal planes. The maximal irradiance concluded by WRF in different regions tended to be volatile in 1 020-1 060 W/m2. [Conclusion] The research provides references for construction of photovoltaic power stations in Shandong Province. 展开更多
关键词 Shandong Province Solar energy resource Photovoltaic power stations Optimum tilt angle WRF(weather research and forecasting model) Maximal daily irradiance
下载PDF
Structural Design and Protective Methods for the 100 kW Shoreline Wave Power Station 被引量:7
4
作者 游亚戈 郑永红 +2 位作者 马玉久 余志 蒋念东 《海洋工程:英文版》 2003年第3期439-448,共10页
The structural design and protective methods for the 100 kW shoreline wave power station in China are described in detail. The proper structural type is designed for effective minimization of wave loads and bending st... The structural design and protective methods for the 100 kW shoreline wave power station in China are described in detail. The proper structural type is designed for effective minimization of wave loads and bending stress. Various protective devices are adopted to protect the station in the extreme conditions against excessive power of airflow, excessive torsion of the shaft, over-pressure of the chamber, over-speed of rotation, power failure, and so on. It turns out that the structural design and protective methods for the 100 kW shoreline wave power station are successful. 展开更多
关键词 wave power station structural design protective measures
下载PDF
Slag-washing water of blast furnace power station with supercritical organic Rankine cycle 被引量:2
5
作者 肖松 吴淑英 郑东升 《Journal of Central South University》 SCIE EI CAS 2013年第3期737-741,共5页
Organic Rankine cycle(ORC) power plant operating with supercritical parameters supplied by low temperature slag-washing water(SWW) of blast furnace was investigated.A schematic of such installation was presented with ... Organic Rankine cycle(ORC) power plant operating with supercritical parameters supplied by low temperature slag-washing water(SWW) of blast furnace was investigated.A schematic of such installation was presented with a description of its operation and the algorithm of calculations of a supercritical power plant.Two typical organic fluids with sufficiently low critical parameters were selected as candidate working fluids in the plant to study the efficiency of the system with different organic fluids.An analysis of the influence on the effectiveness of operation of a plant was carried out.With the same temperature of slag-washing water,the specific work in turbine of fluid R143a is 45% higher than that obtained for the fluid R125,however,the specific work in pump of fluid R143a is approximate equal into that one of the fluid R125. 展开更多
关键词 supercritical cycle slag-washing water organic Rankine cycle power station low temperature
下载PDF
Energy conversion materials for the space solar power station 被引量:2
6
作者 任晓娜 葛昌纯 +6 位作者 陈志培 伊凡 涂用广 张迎春 王立 刘自立 关怡秋 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第7期124-131,共8页
Since it was first proposed,the space solar power station(SSPS)has attracted great attention all over the world;it is a huge space system and provides energy for Earth.Although several schemes and abundant studies on ... Since it was first proposed,the space solar power station(SSPS)has attracted great attention all over the world;it is a huge space system and provides energy for Earth.Although several schemes and abundant studies on the SSPS have been proposed and conducted,it is still not realized.The reason why SSPS is still an idea is not only because it is a giant and complex project,but also due to the requirement for various excellent space materials.Among the diverse required materials,we believe energy materials are the most important.Herein,we review the space energy conversion materials for the SSPS. 展开更多
关键词 space solar power station photovoltaic cell thermoelectric materials LASERS
下载PDF
An Anisotropic Geomechanical Model for Jointed Rock Masses at Taishan Nuclear Power Station, Southern China 被引量:1
7
作者 ZHENG Wentang CHENG Xiaojiu WANG Huaan 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2013年第3期858-870,共13页
An anisotropic geomechanical model for jointed rock mass is presented. Simultaneously with deriving the orthotropic anisotropy elastic parameters along the positive axis, the equivalent compliance matrix for the defle... An anisotropic geomechanical model for jointed rock mass is presented. Simultaneously with deriving the orthotropic anisotropy elastic parameters along the positive axis, the equivalent compliance matrix for the deflection axis orthotropic anisotropy was derived through a three- dimensional coordinate transformation. In addition, Singh's analysis of the stress concentration effects of intermittent joints was adopted, based on two groups of intermittent joints and a set of cross- cutting joints in the jointed rock mass. The stress concentration effects caused by intermittent joints and the coupling effect of cross-cutting joints along the deflection-axis are also considered. The proposed anisotropic mechanics parameters method is applied to determine the deformation parameters of jointed granite at the Taishan Nuclear Power Station. Combined with the deterministic mechanical parameters of rock blocks and joints, the deformation parameters and their variability in jointed rock masses are estimated quantitatively. The computed results show that jointed granite at the Taishan Nuclear Power Station exhibits typical anisotropic mechanical characteristics; the elastic moduli in the two horizontal directions were similar, but the elastic modulus in the vertical direction was much greater. Jointed rock elastic moduli in the two horizontal and vertical directions were respectively about 24% and 37% of the core of rock, showing weakly orthotropic anisotropy; the ratio of elastic moduli in the vertical and horizontal directions was 1.53, clearly indicating the transversely isotropic rock mass mechanical characteristics. The method can be popularized to solve other rock mechanics problems in nuclear power engineering. 展开更多
关键词 Nuclear power station jointed rock masses anisotropic characteristics constitutive model mechanical parameters
下载PDF
TOF SIMS Study on PAHs in Individual Particle from a Power Station 被引量:1
8
作者 梁汉东 于春海 +1 位作者 周强 李艳芳 《Journal of China University of Mining and Technology》 2001年第2期150-154,共5页
The individual particles collected from a power station were analyzed by time of flight secondary ion mass spectrometry (TOF SIMS). The result indicates the presence of the polycyclic aromatic hydrocarbon (PAHs) as we... The individual particles collected from a power station were analyzed by time of flight secondary ion mass spectrometry (TOF SIMS). The result indicates the presence of the polycyclic aromatic hydrocarbon (PAHs) as well as the oxygenated one. They might be derived from the incomplete combustion of coals. SIMS has proved to be a rapid method for the qualitative analysis of PAHs and OPAHs absorbed on the aerosol particles. New perspectives for better understanding the SIMS spectra obtained from complex mixture such as environmental samples have been opened. 展开更多
关键词 TOF SIMS polycyclic aromatic hydrocarbon (PAHs) oxygenated polycyclic aromatic hydrocarbon (OPAHs) environmental particles power station
下载PDF
Research on H_2 speed governor for diesel engine of marine power station
9
作者 HUANG Man-lei 《Journal of Marine Science and Application》 2007年第3期51-57,共7页
The frequency stability of a marine power system is determined by the dynamic characteristic of the diesel engine speed regulation system in a marine power station. In order to reduce the effect of load disturbances a... The frequency stability of a marine power system is determined by the dynamic characteristic of the diesel engine speed regulation system in a marine power station. In order to reduce the effect of load disturbances and improve the dynamic precision of a diesel engine speed governor, a controller was designed for a diesel engine speed regulation system using H2 control theory. This transforms the specifications of the system into a standard H2 control problem. Firstly, the mathematical model of a diesel engine speed regulation system using an H2 speed governor is presented. To counter external disturbances and model uncertainty, the design of an H, speed governor rests on the problem of mixed sensitivity. Computer simulation verified that the H2 speed governor improves the dynamic precision of a system and the ability to adapt to load disturbances, thus enhancing the frequency stability of marine power systems. 展开更多
关键词 marine power station diesel engine SPEED overnor H CONTROL
下载PDF
Investigation on the seismic response of nuclear power stations with a pile-raft foundation using centrifuge tests
10
作者 Li Zhongcheng Yang Yang +3 位作者 Gong Weiming Yi Pik Cheng Dai Guoliang Liang Fayun 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第3期753-768,共16页
Research to reliably predict the seismic response of nuclear power stations with a pile-raft foundation is needed to meet the high safety requirements of nuclear power stations.In this study,a scaled superstructure wi... Research to reliably predict the seismic response of nuclear power stations with a pile-raft foundation is needed to meet the high safety requirements of nuclear power stations.In this study,a scaled superstructure with a 4×3 pile-raft foundation,which is constructed in Shanxi kaolin clay,is modelled.Accordingly,the characteristics of seismic response for nuclear power stations with a pile-raft foundation are analyzed using dynamic centrifuge tests.In particular,multiple earthquake motions with different magnitudes and frequency properties are utilized to map the relationship between structural response and properties of earthquake motions.The results show that the seismic response of the soil,raft,and structure are significantly affected by the natural frequency and magnitude of the earthquake motion.The soil surface acceleration is lower than the raft acceleration.The results provide a reliable reference to better understand the seismic response of nuclear power stations. 展开更多
关键词 dynamic centrifuge test seismic response pile-raft foundation nuclear power station soil-structure interaction
下载PDF
Fatigue Life Prediction of Mooring Chains for a Floating Tidal Current Power Station
11
作者 Fengmei Jing Liang Zhang Zhong Yang 《Journal of Marine Science and Application》 2012年第2期216-221,共6页
As a kind of clean and renewable energy,tidal current energy is becoming increasingly popular all over the world with the shortage of energy and environmental problems becoming more and more severe.A floating tidal cu... As a kind of clean and renewable energy,tidal current energy is becoming increasingly popular all over the world with the shortage of energy and environmental problems becoming more and more severe.A floating tidal current power station is a typical type of tidal current power transformers which can sustain the loads of wind,waves,and current,and even the extreme situation of a typhoon.Therefore,the mooring system must be reliable enough to keep the station operating normally and to survive in extreme situations.The power station examined in this paper was installed at a depth of 40 m.A 44 mm-diameter R4-RQ4 chain was chosen,with a 2 147 kN minimum break strength and 50 kN pretension.Common studless link chain was used in this paper.Based on the Miner fatigue cumulative damage rule,S-N curves of chains,and MOSES software,a highly reliable mooring system was designed and analyzed.The calculation results show that the mooring system designed is reliable throughout a 10-year period.It can completely meet the design requirements of American Petroleum institution(API).Therefore,the presented research is significant for advancing the design of this kind of power station. 展开更多
关键词 floating tidal current power station mooring system mooring chain fatigue analysis
下载PDF
Multi-Layer and Multi-Objective Optimization Design of Supporting Structure of Large-Scale Spherical Solar Concentrator for the Space Solar Power Station
12
作者 Yang Yang Jun Hu +1 位作者 Lin Zhu Mengchen Pei 《Journal of Renewable Materials》 SCIE EI 2022年第11期2835-2849,共15页
Space solar power station is a novel renewable energy equipment in space to provide the earth with abundant and continuous power.The Orb-shaped Membrane Energy Gathering Array,one of the alternative construction schem... Space solar power station is a novel renewable energy equipment in space to provide the earth with abundant and continuous power.The Orb-shaped Membrane Energy Gathering Array,one of the alternative construction schemes in China,is promising for collecting space sunlight with a large-scale spherical concentrator.Both the structural and optical performances such as root mean square deformation,natural frequency,system mass,and sunlight blocking rate have significant influences on the system property of the concentrator.Considering the comprehensive performance of structure and optic,this paper proposes a novel mesh grid based on normal polyhedron projection and spherical arc bisection for the supporting structure to deal with the challenge of the large-scale structural modular design.For both achieving low system mass and high surface precision,a multilayer and multi-objective optimization model is proposed by classifying the supporting structure into different categories and optimizing their internal and external diameters.The Particle Swarm Optimization algorithm is adopted to find optimal sectional dimensions of the different kinds of supporting structure.The infinite model is also established and structural analysis is carried out,which are expected to provide a certain reference for the subsequent detailed structural design.The numerical results indicate that the spherical concentrator designed by the novel mesh grid would obtain as high as 94.37%sunlight collection efficiency.The supporting structure constructed with the multiple layers would reduce the system quality by 6.92%,sunlight blocking rate by 28.54%,maximum deformation by 41.50%,and root mean square by 9.48%to the traditional single layer,respectively. 展开更多
关键词 Solar power space solar power station the OMEGA concept structural optimization particle swarm optimization
下载PDF
Engineering Geological Study of Regional Tectonic Stability in the Area of the Longyang Gorge Power Station on the Huanghe (Yellow) River
13
作者 Wang Shitian, Li Yusheng, Su Daogang and Wei Lunwu Chengdu College of Geology, Chengdu, Sichuan Fei Zhenbi 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 1989年第2期197-209,共13页
In the stability study of the regional structures in the area of the Longyang Gorge Hydroelectrical Power Station, a model of the current stress-deformation field of the area was constructed based on analyses of avail... In the stability study of the regional structures in the area of the Longyang Gorge Hydroelectrical Power Station, a model of the current stress-deformation field of the area was constructed based on analyses of available data of regional surveys and historical earthquakes and field investigations of active faults and ancient earthquakes. This model was examined and verified by physical and mathematical simulation experiments, and quantitative relations and data were obtained. 展开更多
关键词 RIVER area Engineering Geological Study of Regional Tectonic Stability in the Area of the Longyang Gorge power station on the Huanghe YELLOW
下载PDF
Phytoplankton ecology in the adjacent waters of the Daya Bay Nuclear Power Station in Guangdong in spring
14
《Acta Oceanologica Sinica》 SCIE CAS CSCD 1992年第4期617-624,共8页
The purpose of this study is to detail the ecological characteristics of phytoplankton in waters around the Daya Bay Nuclear Power Station in Guangdong (GNPS) (Fig. 1) in spring, the bloom period of algae. The collect... The purpose of this study is to detail the ecological characteristics of phytoplankton in waters around the Daya Bay Nuclear Power Station in Guangdong (GNPS) (Fig. 1) in spring, the bloom period of algae. The collections with a small temporal scale of every three days were made during 30 cruises from March to May in 1987. Such an investigation has never been carried out before in China except that the seasonal distribution and composition of phytoplankton in these regions were reported in 展开更多
关键词 St Phytoplankton ecology in the adjacent waters of the Daya Bay Nuclear power station in Guangdong in spring BAY
下载PDF
PSO-BP-Based Optimal Allocation Model for Complementary Generation Capacity of the Photovoltaic Power Station
15
作者 Zhenfang Liu Haibo Liu Dongmei Zhang 《Energy Engineering》 EI 2023年第7期1717-1727,共11页
To improve the operation efficiency of the photovoltaic power station complementary power generation system,an optimal allocation model of the photovoltaic power station complementary power generation capacity based o... To improve the operation efficiency of the photovoltaic power station complementary power generation system,an optimal allocation model of the photovoltaic power station complementary power generation capacity based on PSO-BP is proposed.Particle Swarm Optimization and BP neural network are used to establish the forecasting model,the Markov chain model is used to correct the forecasting error of the model,and the weighted fitting method is used to forecast the annual load curve,to complete the optimal allocation of complementary generating capacity of photovoltaic power stations.The experimental results show that thismethod reduces the average loss of photovoltaic output prediction,improves the prediction accuracy and recall rate of photovoltaic output prediction,and ensures the effective operation of the power system. 展开更多
关键词 Photovoltaic power station complementary power generation capacity optimization resource allocation
下载PDF
Optimal Configuration Method for the Installed Capacity of the Solar-Thermal Power Stations
16
作者 Yan Wang Zhicheng Ma +3 位作者 Jinping Zhang Qiang Zhou Ruiping Zhang Haiying Dong 《Energy Engineering》 EI 2023年第4期949-963,共15页
Because of the randomness of wind power and photovoltaic(PV)output of new energy bases,the problem of peak regulation capability and voltage stability of ultra-high voltage direct current(UHVDC)transmission lines,we p... Because of the randomness of wind power and photovoltaic(PV)output of new energy bases,the problem of peak regulation capability and voltage stability of ultra-high voltage direct current(UHVDC)transmission lines,we proposed an optimum allocation method of installed capacity of the solar-thermal power station based on chance constrained programming in this work.Firstly,we established the uncertainty model of wind power and PV based on the chance constrained planning theory.Then we used the K-medoids clusteringmethod to cluster the scenarios considering the actual operation scenarios throughout the year.Secondly,we established the optimal configuration model based on the objective function of the strongest transient voltage stability and the lowest overall cost of operation.Finally,by quantitative analysis of actual wind power and photovoltaic new energy base,this work verified the feasibility of the proposed method.As a result of the simulations,we found that using the optimal configuration method of solar-thermal power stations could ensure an accurate allocation of installed capacity.When the installed capacity of the solar-thermal power station is 1×106 kW,the transient voltage recovery index(TVRI)is 0.359,which has a strong voltage support capacity for the system.Based on the results of this work,the optimal configuration of the installed capacity of the solar-thermal power plant can improve peak shaving performance,transient voltage support capability,and new energy consumption while satisfying the Direct Current(DC)outgoing transmission premise. 展开更多
关键词 Solar-thermal power station optimal configuration of installed capacity new energy base multi-objective optimization chance constrained planning theory
下载PDF
The design of Three Gorges Hydropower Station
17
作者 Zhou Shuda Xie Hongbing 《Engineering Sciences》 EI 2011年第3期66-73,共8页
Using physical model and numerical simulation techniques, some technical problems were studied systemati- cally, including layout of power station, measures of sediment and floating debris discharging, types of intake... Using physical model and numerical simulation techniques, some technical problems were studied systemati- cally, including layout of power station, measures of sediment and floating debris discharging, types of intake, embed- ded types of spiral ease, layout of underground powerhouse tunnel group and block reinforcement. It was optimal in technique and economy with the arrangement of powerhouse at the dam-toe of both banks + underground powerhouse in the right bank, as well as the intake with a single and small orifice. The sediment and debris problems could be solved with disperse sediment ejection and floating debris discharging holes. With the adoption of techniques for spiral cases such as heat and pressure preservation, cushion layer and combined embedding, the stable operation of generating units can be guaranteed. The arrangement of tailrace tunnel with sloping ceiling was better than that of tailrace surge tank. The technical requirements related to the embedding type of spiral case were proposed. The reinforcement of huge unfavorable blocks was discussed and the new idea for block reinforcement using anti-sliding piles and normal compressive stress of structural plane was put forward. 展开更多
关键词 Three Gorges power station layout sediment and floating debris discharging spiral case embedding shallow embedment block reinforcement
下载PDF
Seasonal Distribution of Manganese in the Soil-Water-Plant in the Zone of Burshtyn Thermal Power Station
18
作者 Ivan V. Mazepa Natalia V. Dovganich Maria A. Mazepa 《Journal of Physical Science and Application》 2014年第5期317-322,共6页
This study deals with the impact of Burshtyn thermal power station on the amount of manganese in soil, water and celandine tissue. The research of manganese amount and form in the system: water-plant is of great impo... This study deals with the impact of Burshtyn thermal power station on the amount of manganese in soil, water and celandine tissue. The research of manganese amount and form in the system: water-plant is of great importance due to active influence of thermal power station on the chemical structure of the polluted area. The changes in the amount and form of manganese in soil, water and plant are interrelated and depend on the season, the distance from the polluter and morph-functional plant structure, the cleaning system possibilities of the industrial enterprise and some meteorological factors. 展开更多
关键词 Soil water celandine gross and changeable manganese amount Burshtyn thermal power station.
下载PDF
Virtual Synchronous Generator Adaptive Control of Energy Storage Power Station Based on Physical Constraints
19
作者 Yunfan Huang Qingquan Lv +1 位作者 Zhenzhen Zhang Haiying Dong 《Energy Engineering》 EI 2023年第6期1401-1420,共20页
The virtual synchronous generator(VSG)can simulate synchronous machine’s operation mechanism in the control link of an energy storage converter,so that an electrochemical energy storage power station has the ability ... The virtual synchronous generator(VSG)can simulate synchronous machine’s operation mechanism in the control link of an energy storage converter,so that an electrochemical energy storage power station has the ability to actively support the power grid,from passive regulation to active support.Since energy storage is an important physical basis for realizing the inertia and damping characteristics in VSG control,energy storage constraints of the physical characteristics on the system control parameters are analyzed to provide a basis for the system parameter tuning.In a classic VSG control,its virtual inertia and damping coefficient remain unchanged.When the grid load changes greatly,the constant control strategy most likely result in the grid frequency deviation beyond the stable operation standard limitations.To solve this problem,a comprehensive control strategy considering electrified wire netting demand and energy storage unit state of charge(SOC)is proposed,and an adaptive optimization method of VSG parameters under different SOC is given.The energy storage battery can maintain a safe working state at any time and be smoothly disconnected,which can effectively improve the output frequency performance of energy storage system.Simulation results further demonstrated the effectiveness of the VSG control theoretical analysis. 展开更多
关键词 VSG energy storage power station physical constraints of energy storage adaptive parameter frequency performance
下载PDF
Effects of Depression of Water Level in the Euphrates River in Iraq on the Operation of AI-Anbar Thermal Power Station
20
作者 Ammar Hatem Kamel Issam Mohammed Ayad Sulaiby Mustaffa 《Journal of Civil Engineering and Architecture》 2013年第3期350-363,共14页
Increase in demand of electrical power for different purposes in Iraq leads increase towards to power plant system such as thermal power plant. Any thermal power plant requires water for processing, cooling, oilfields... Increase in demand of electrical power for different purposes in Iraq leads increase towards to power plant system such as thermal power plant. Any thermal power plant requires water for processing, cooling, oilfields, boiler feed and other miscellaneous uses including domestic requirements. The main parameter to measure the efficiency of thermal power plant is the availability of water and technology employed. Therefore, the thermal power plants like A1-Anbar thermal power station is built on the Euphrates River bank in the city of Ramadi in the middle part of Iraq. Depending on the field measurements and pervious measurements, the computation of river water level for different frequency periods was achieved to determine the inundation area of the plant and the required height of power plant intakes. The problems of intake operation include low flow rate of the river at intake that resulting low water level (minimum flow rate was recorded 107 m^3/s with water level 47.8 m), and annual sediments at intake that may be caused operation off. Therefore, any design for the intake or operation must consider the above problems. The study referred to the discharge for full operation is about 300 m^3/s and water level is 51.3 m to satisfy these requirements. The study suggested two solutions for this problem, first by using the groins and the second by building two weirs. 展开更多
关键词 Thermal power station hydrologic study intake structure.
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部