期刊文献+
共找到224篇文章
< 1 2 12 >
每页显示 20 50 100
Study on Transformer Magnetic Biasing Control Method for AC Power Supplies 被引量:5
1
作者 卢家林 孙晋 苏彦民 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2001年第4期17-22,共6页
This paper presents a novel transformer magnetic biasing control method for high-power high-performance AC power supplies. Serious consequences due to magnetic biasing and several methods to overcome magnetic biasing ... This paper presents a novel transformer magnetic biasing control method for high-power high-performance AC power supplies. Serious consequences due to magnetic biasing and several methods to overcome magnetic biasing are first discussed. The causes of the transformer magnetic biasing are then analyzed in detail. The proposed method is based on a high-pass filter inserted in the forward path and the feedforward control. Without testing magnetic biasing of transformer, this method can eliminate magnetic biasing of transformer completely in real-time waveform feedback control systems though the zero error of the Hall effect sensors varies with time and temperature. The method has already been employed in a 90KVA AC power supply. It is shown that it offers improved performance over existing ones. In this method, no sensors are used such that the zero error of the Hall effect sensors has not any influence on the system. It is simple to design and implement. Furthermore, the method is suitable for various power applications. 展开更多
关键词 AC machinery Electric power supplies to apparatus Feedback control Hall effect High pass filters Real time systems SENSORS
下载PDF
Reducing the minimum output power of soft-switching inverter arc welding power supplies 被引量:1
2
作者 傅强 薛松柏 《China Welding》 EI CAS 2010年第3期45-49,共5页
The full-bridge zero-voltage and zero-current switching inverter, which can adjust the output power by keeping the duty-cycle of lagging arm constant, changing the duty-cycle of leading arm, is a common circuit topolo... The full-bridge zero-voltage and zero-current switching inverter, which can adjust the output power by keeping the duty-cycle of lagging arm constant, changing the duty-cycle of leading arm, is a common circuit topology of soft-switching inverter arc welding power supplies. However, the output power still remains a certain value when the duty-cycle of leading arm decreases to zero. The working-mode of soft-switching inverter and the waveforms of major parameters with the condition of duty-cycle of leading arm being zero are studied in this paper. U-1 characteristic experiments prove that the minimum output power of soft-switching circuit, which depends on the charged voltage of capacitors in parallel with leading arm, can be decreased by reducing the duty-cycle of lagging arm. By switching working-modes between half-bridge and full-bridge, the output power can swing from zero to the power rating. 展开更多
关键词 SOFT-SWITCHING inverter arc welding power supplies minimum output power
下载PDF
Effects of O_(2) addition on the plasma uniformity and reactivity of Ar DBD excited by ns pulsed and AC power supplies 被引量:1
3
作者 Feng LIU Yue ZHUANG +2 位作者 Yulei ZHAO Jie CHEN Zhi FANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第5期29-38,共10页
Dielectric barrier discharges(DBDs)have been widely used in ozone synthesis,materials surface treatment,and plasma medicine for their advantages of uniform discharge and high plasmachemical reactivity.To improve the r... Dielectric barrier discharges(DBDs)have been widely used in ozone synthesis,materials surface treatment,and plasma medicine for their advantages of uniform discharge and high plasmachemical reactivity.To improve the reactivity of DBDs,in this work,the O_(2) is added into Ar nanosecond(ns)pulsed and AC DBDs.The uniformity and discharge characteristics of Ar ns pulsed and AC DBDs with different O_(2) contents are investigated with optical and electrical diagnosis methods.The DBD uniformity is quantitatively analyzed by gray value standard deviation method.The electrical parameters are extracted from voltage and current waveforms separation to characterize the discharge processes and calculate electron density n_(e).The optical emission spectroscopy is measured to show the plasma reactivity and calculate the trend of electron temperature T_(e) with the ratio of two emission lines.It is found that the ns pulsed DBD has a much better uniformity than AC DBD for the fast rising and falling time.With the addition of O_(2),the uniformity of ns pulsed DBD gets worse for the space electric field distortion by O_(2)^(-),which promotes the filamentary formation.While,in AC DBD,the added O_(2) can reduce the intensity of filaments,which enhances the discharge uniformity.The ns pulsed DBD has a much higher instantaneous power and energy efficiency than AC DBD.The ratio of Ar emission intensities indicates that the T_(e) drops quickly with the addition of O_(2) both ns pulsed and AC DBDs and the ns pulsed DBD has an obvious higher T_(e) and n_(e) than AC DBD.The results are helpful for the realization of the reactive and uniform low temperature plasma sources. 展开更多
关键词 nanosecond pulse power supply dielectric barrier discharge discharge uniformity oxygen addition
下载PDF
Analysis and design of over-current limit control strategies applied in aeronautical power supplies 被引量:1
4
作者 王林兵 何湘宁 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2007年第2期287-291,共5页
Some Over-Current Limit Control strategies are analyzed and designed to meet the demands of high reliability and rapid dynamic response in the aeronautical power supply applications. The control schemes are both effec... Some Over-Current Limit Control strategies are analyzed and designed to meet the demands of high reliability and rapid dynamic response in the aeronautical power supply applications. The control schemes are both effective in DC-DC converters and DC-AC converters. Controller models are set up, and the over-current limit operation principles of analogy and digital control are analyzed too. An 800VA aeronautical power supply bas been constructed to verify the performance of the proposed control strategy in various cases such as the sudden load change and the constant load. The analysis and experiments confirm the advantages of the proposed over-current limit strategies as follows: simple,effective and reliable. 展开更多
关键词 over-current limit control: power converter aeronautical power supply
下载PDF
Overview of Circuit Topologies for Inductive Pulsed Power Supplies 被引量:3
5
作者 Xinjie Yu Xukun Liu 《CES Transactions on Electrical Machines and Systems》 2017年第3期265-272,共8页
The pulsed power supply(PPS)is one important component in the electromagnetic launch system.The inductive PPSs have attracted researchers’attentions with the major advantages of high energy storage density(over the c... The pulsed power supply(PPS)is one important component in the electromagnetic launch system.The inductive PPSs have attracted researchers’attentions with the major advantages of high energy storage density(over the capacitive PPSs)as well as simple structure and easy control(over the rotating mechanical PPSs).As for the inductive PPSs,the circuit topology of the basic module will directly determine the comprehensive performance of the whole system.From the perspectives of working principles,strengths,weaknesses,and comprehensive performance,this paper presents a historical and technical review of the major circuit topologies for the inductive PPSs. 展开更多
关键词 Circuit topology electromagnetic railgun inductive energy storage inductive pulsed power supply meat grinder XRAM
下载PDF
Design method for transistor-inverted welding power supplies
6
作者 刘会杰 冯吉才 李卓然 《China Welding》 EI CAS 1998年第2期76-81,共6页
From the viewpoint of reliability and practicability, a general design method and the related considerationsfor transistor- inverted welding power supplies are proposed in this paper. The detail contents are composed ... From the viewpoint of reliability and practicability, a general design method and the related considerationsfor transistor- inverted welding power supplies are proposed in this paper. The detail contents are composed of the choice ofinverters, the choice and protection of transistors, the determination of inverting frequency, the design of transformers,and the choice of output rectifiers and rectifying diodes. Besides, a concrete design example of the transistor-invertedpower supply for plasma arc cutting is introduced. 展开更多
关键词 inverted power supply welding power supply design method TRANSISTOR
下载PDF
Traction power systems for electrified railways:evolution,state of the art,and future trends 被引量:1
7
作者 Haitao Hu Yunjiang Liu +4 位作者 Yong Li Zhengyou He Shibin Gao Xiaojuan Zhu Haidong Tao 《Railway Engineering Science》 EI 2024年第1期1-19,共19页
Traction power systems(TPSs)play a vital role in the operation of electrified railways.The transformation of conventional railway TPSs to novel structures is not only a trend to promote the development of electrified ... Traction power systems(TPSs)play a vital role in the operation of electrified railways.The transformation of conventional railway TPSs to novel structures is not only a trend to promote the development of electrified railways toward high-efficiency and resilience but also an inevitable requirement to achieve carbon neutrality target.On the basis of sorting out the power supply structures of conventional AC and DC modes,this paper first reviews the characteristics of the existing TPSs,such as weak power supply flexibility and low-energy efficiency.Furthermore,the power supply structures of various TPSs for future electrified railways are described in detail,which satisfy longer distance,low-carbon,high-efficiency,high-reliability and high-quality power supply requirements.Meanwhile,the application prospects of different traction modes are discussed from both technical and economic aspects.Eventually,this paper introduces the research progress of mixed-system electrified railways and traction power supply technologies without catenary system,speculates on the future development trends and challenges of TPSs and predicts that TPSs will be based on the continuous power supply mode,employing power electronic equipment and intelligent information technology to construct a railway comprehensive energy system with renewable energy. 展开更多
关键词 Railway traction power system Future electrified railway Flexible continuous power supply Renewable energy Integrated energy system
下载PDF
Study on green power supply modes for heavy load in Remote Areas
8
作者 Yu Li Yixi Cuomu +4 位作者 Yiming Gao Guoqin Lv Weiwei Lin Sirui Li Changchun Zhou 《Global Energy Interconnection》 EI CSCD 2024年第4期475-485,共11页
In this study,the present situation and characteristics of power supply in remote areas are summarized.By studying the cases of power supply projects in remote areas,the experience is analyzed and described,and the ap... In this study,the present situation and characteristics of power supply in remote areas are summarized.By studying the cases of power supply projects in remote areas,the experience is analyzed and described,and the applicability of related technologies,such as grid-forming storage and power load management,is studied,including grid-connection technologies,such as grid-forming converters and power load management.On this basis,three power-supply modes were proposed.The application scenarios and advantages of the three modes were compared and analyzed.Based on the local development situation,the temporal sequences of the three schemes are described,and a case study was conducted.The study of the heavy-load power supply mode in remote areas contributes to solving the problem of heavy-load green power consumption in remote areas and promoting the further development of renewable energy. 展开更多
关键词 Remote area Renewable energy Grid-forming storage power load management power supply mode
下载PDF
Low-frequency oscillation of train-network system considering traction power supply mode
9
作者 Yuchen Liu Xiaoqin Lyu +1 位作者 Mingyuan Chang Qiqi Yang 《Railway Engineering Science》 EI 2024年第2期244-256,共13页
The low-frequency oscillation(LFO)has occurred in the train-network system due to the introduction of the power electronics of the trains.The modeling and analyzing method in current researches based on electrified ra... The low-frequency oscillation(LFO)has occurred in the train-network system due to the introduction of the power electronics of the trains.The modeling and analyzing method in current researches based on electrified railway unilateral power supply system are not suitable for the LFO analysis in a bilateral power supply system,where the trains are supplied by two traction substations.In this work,based on the single-input and single-output impedance model of China CRH5 trains,the node admittance matrices of the train-network system both in unilateral and bilateral power supply modes are established,including three-phase power grid,traction transformers and traction network.Then the modal analysis is used to study the oscillation modes and propagation characteristics of the unilateral and bilateral power supply systems.Moreover,the influence of the equivalent inductance of the power grid,the length of the transmission line,and the length of the traction network are analyzed on the critical oscillation mode of the bilateral power supply system.Finally,the theoretical analysis results are verified by the time-domain simulation model in MATLAB/Simulink. 展开更多
关键词 Low-frequency oscillation Train-network system Modal analysis Bilateral power supply Participation factor
下载PDF
Research on the longitudinal protection of a through-type cophase traction direct power supply system based on the empirical wavelet transform
10
作者 Lu Li Zeduan Zhang +5 位作者 Wang Cai Qikang Zhuang Guihong Bi Jian Deng Shilong Chen Xiaorui Kan 《Global Energy Interconnection》 EI CSCD 2024年第2期206-216,共11页
This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a disti... This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a distinctive boundary structure.This approach capitalizes on the boundary’s capacity to attenuate the high-frequency component of fault signals,resulting in a variation in the high-frequency transient energy ratio when faults occur inside or outside the line.During internal line faults,the high-frequency transient energy at the checkpoints located at both ends surpasses that of its neighboring lines.Conversely,for faults external to the line,the energy is lower compared to adjacent lines.EWT is employed to decompose the collected fault current signals,allowing access to the high-frequency transient energy.The longitudinal protection for the traction network line is established based on disparities between both ends of the traction network line and the high-frequency transient energy on either side of the boundary.Moreover,simulation verification through experimental results demonstrates the effectiveness of the proposed protection scheme across various initial fault angles,distances to faults,and fault transition resistances. 展开更多
关键词 Through-type Cophase traction direct power supply system Traction network Empirical wavelet transform(EWT) Longitudinal protection
下载PDF
Wireless Power Supply Based on MNG-MNZ Metamaterial for Cardiac Pacemakers
11
作者 Weihua Chen Jingtao Jia +2 位作者 Xiaoheng Yan Yuhang Song Jiayi Li 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第1期103-112,共10页
To solve the low power transfer efficiency and magnetic field leakage problems of cardiac pacemaker wireless powering, we proposed a wireless power supply system suitable for implanted cardiac pacemaker based on mu-ne... To solve the low power transfer efficiency and magnetic field leakage problems of cardiac pacemaker wireless powering, we proposed a wireless power supply system suitable for implanted cardiac pacemaker based on mu-negative(MNG) and mu-nearzero(MNZ) metamaterials. First, a hybrid metamaterial consisted of central MNG unit for magnetic field concentration and surrounding MNZ units for magnetic leakage shielding was established by theoretical calculation. Afterwards, the magnetic field distribution of wireless power supply system with MNG-MNZ metamaterial slab was acquired via finite element simulation and verified to be better than the distribution with conventional MNG slab deployed. Finally, an experimental platform of wireless power supply system was established with which power transfer experiment and system temperature rise experiment were conducted.Simulation and experimental results showed that the power transfer efficiency was improved from 44.44%,19.42%, 8.63% and 6.19% to 55.77%, 62.39%, 20.81%and 14.52% at 9.6 mm, 20 mm, 30 mm and 50 mm,respectively. The maximum SAR acquired by SAR simulation under human body environment was-7.14 dbm and maximum reduction of the magnetic field strength around the receiving coil was 2.82 A/m. The maximum temperature rise during 30min charging test was 3.85℃,and the safety requirements of human bodies were met. 展开更多
关键词 Cardiac pacemaker MNG metamaterial MNZ metamaterial Wireless power supply system
下载PDF
Research on uninterruptable power supply technology for auxiliary winding of electric locomotive while passing the neutral section
12
作者 Yuliang Du 《Railway Sciences》 2024年第2期128-142,共15页
Purpose–Auxiliary power system is an indispensable part of the train;the auxiliary systems of both electric locomotives and EMUs mainly are powered by one of the two ways,which are either from auxiliary windings of t... Purpose–Auxiliary power system is an indispensable part of the train;the auxiliary systems of both electric locomotives and EMUs mainly are powered by one of the two ways,which are either from auxiliary windings of traction transformers or from DC-link voltage of traction converters.Powered by DC-link voltage of traction converters,the auxiliary systems were maintained of uninterruptable power supply with energy from electric braking.Meanwhile,powered by traction transformers,the auxiliary systems were always out of power while passing the neutral section of power supply grid and control system is powered by battery at this time.Design/methodology/approach–Uninterrupted power supply of auxiliary power system powered by auxiliary winding of traction transformer was studied.Failure reasons why previous solutions cannot be realized are analyzed.An uninterruptable power supply scheme for the auxiliary systems powered by auxiliary windings of traction transformers is proposed in this paper.The validity of the proposed scheme is verified by simulation and experimental results and on-site operation of an upgraded HXD3C type locomotive.This scheme is attractive for upgrading practical locomotives with the auxiliary systems powered by auxiliary windings of traction transformers.Findings–This scheme regenerates braking power supplied to auxiliary windings of traction transformers while a locomotive runs in the neutral section of the power supply grid.Control objectives of uninterrupted power supply technology are proposed,which are no overvoltage,no overcurrent and uninterrupted power supply.Originality/value–The control strategies of the scheme ensure both overvoltage free and inrush current free when a locomotive enters or leaves the neutral section.Furthermore,this scheme is cost low by employing updated control strategy of software and add both the two current sensors and two connection wires of hardware. 展开更多
关键词 Electric locomotive Auxiliary system Neutral section Uninterruptable power supply OVERVOLTAGE Inrush current
下载PDF
Review of Power Supply and Distribution Construction Technology for Highway Electromechanical Engineering
13
作者 Li Liu 《Journal of Electronic Research and Application》 2024年第2期27-32,共6页
In recent years,China has made significant progress in the construction of highways,resulting in an improved highway network that has provided robust support for economic and social development.However,the rapid expan... In recent years,China has made significant progress in the construction of highways,resulting in an improved highway network that has provided robust support for economic and social development.However,the rapid expansion of highway construction,power supply,and distribution has led to several challenges in mechanical and electrical engineering technology.Ensuring the safe,stable,and cost-effective operation of the power supply and distribution system to meet the diverse requirements of highway operations has become a pressing issue.This article takes an example of a highway electromechanical engineering power supply and distribution construction project to provide insight into the construction process of highway electromechanical engineering power supply and distribution technology. 展开更多
关键词 HIGHWAY Mechanical and electrical engineering power supply and distribution construction technology Construction process
下载PDF
Advances in the development of power supplies for the Internet of Everything 被引量:14
14
作者 Xiayue Fan Xiaorui Liu +2 位作者 Wenbin Hu Cheng Zhong Jun Lu 《InfoMat》 SCIE CAS 2019年第2期130-139,共10页
The Internet of Everything(IoE),which aims to realize information exchange and communications for anything with the Internet,has revolutionized our modern world.Serving as the driving force for devices in the IoE netw... The Internet of Everything(IoE),which aims to realize information exchange and communications for anything with the Internet,has revolutionized our modern world.Serving as the driving force for devices in the IoE network,power supply systems play a fundamental role in the development of the IoE.However,due to the complexity,multifunctionality and wide-scale deployment of diverse applications,power supply systems face great challenges,including distribution,connection,charging technologies,and management.In this review,some challenges and advances in the development of both power supply systems and their units are presented.In the overall system-level field,establishing sustainable and maintenancefree power supply systems through wireless connections,efficient power management and integrated energy harvesting and storage systems is highlighted.Additionally,the main performance metrics of power supply units are discussed,including energy density,service life,and self-power ability.In addition,some directions of power quality assessment for both the system and unit levels of power supply systems are presented,aiming to provide insight into the future development of high-performance power supply systems for the IoE. 展开更多
关键词 assessment of power supply systems Internet of Everything power supply systems power supply units
原文传递
Implementation of 1.7 kV Silicon Carbide Metal Oxide Semiconductor Field Effect Transistors in Auxiliary Power Supplies for Industrial Applications 被引量:2
15
作者 Xuning Zhang Gin Sheh 《Chinese Journal of Electrical Engineering》 CSCD 2020年第3期46-55,共10页
An auxiliary power supply(Aux-PS)has become an essential component of electronic equipment for many industrial applications,such as in motor drives,photovoltaic(PV)inverters,uninterruptible power supply(UPS)systems an... An auxiliary power supply(Aux-PS)has become an essential component of electronic equipment for many industrial applications,such as in motor drives,photovoltaic(PV)inverters,uninterruptible power supply(UPS)systems and modular multilevel converters.The introduction of 1700 V silicon carbide(SiC)metal oxide semiconductor field effect transistors(MOSFETs)is useful for such applications,providing benefits with respect to a low on-state resistance,smaller package,low switching loss and single-switching implementation.A single end flyback Aux-PS is designed for industrial applications with a wide input voltage range using 1.7 kV SiC MOSFETs.The special design tradeoffs involved in the usage of SiC MOSFETs are discussed in detail,such as those with regard to gate driving voltage selection,isolation transformer design considerations,and clamping circuit design details.A 60 W demonstration hardware is developed and tested under different working conditions.The results verify the higher efficiency and better thermal performance of the proposed hardware relative to those of traditional Si solutions. 展开更多
关键词 Silicon carbide MOSFET wide input range auxiliary power supply
原文传递
DC active power filter based on model predictive control for DC bus overvoltage suppression of accelerator grid power supply 被引量:1
16
作者 张鸿淇 朱帮友 +3 位作者 马少翔 李志恒 张明 潘垣 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第6期1-13,共13页
The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated... The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated step-up structure.There is a DC bus between the rectifier and the inverter.In order to limit DC bus voltage ripple and transient fluctuations,a large number of capacitors are used,which degrades the reliability of the power supply and occupies a large amount of space.This work finds that due to the difference in the turn-off time of the rectifier and the inverter,the capacitance mainly depends on the rectifier current when the inverter is turned off.On this basis,an active power filter(APF)scheme is proposed to absorb the current.To enhance the dynamic response ability of the APF,model predictive control is adopted.In this paper,the circuit structure of the APF is introduced,the prediction model is deduced,the corresponding control strategy and signal detection method are proposed,and the simulation and experimental results show that APF can track the transient current of the DC bus and reduce the voltage fluctuation significantly. 展开更多
关键词 CFETR NBI accelerator grid power supply power active filter model predictive control
下载PDF
Electrical characteristics of new three-phase traction power supply system for rail transit 被引量:1
17
作者 Xiaohong Huang Hanlin Wang +4 位作者 Qunzhan Li Naiqi Yang Tao Ren You Peng Haoyang Li 《Railway Engineering Science》 2023年第1期75-88,共14页
A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.... A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.With the application of two-stage three-phase continuous power supply structure,the electrical characteristics exhibit new features differing from the existing traction system.In this work,the principle for voltage levels determining two-stage network is dissected in accordance with the requirements of traction network and electric locomotive.The equivalent model of three-phase traction system is built for deducing the formula of current distribution and voltage losses.Based on the chain network model of the traction network,a simulation model is established to analyze the electrical characteristics such as traction current distribution,voltage losses,system equivalent impedance,voltage distribution,voltage unbalance and regenerative energy utilization.In a few words,quite a lot traction current of about 99%is undertaken by long-section cable network.The proportion of system voltage losses is small attributed to the two-stage three-phase power supply structure,and the voltage unbal-ance caused by impedance asymmetry of traction network is less than 1‰.In addition,the utilization rate of regenerative energy for locomotive achieves a significant promotion of over 97%. 展开更多
关键词 Three-phase AC power supply Two-stage power supply structure Electrical characteristics Current distribution Voltage losses Regenerative energy
下载PDF
Research on protection system of resonant network in CSNS magnet power supplies
18
作者 Xiao-Ling Guo Wen-qing Zhang +4 位作者 Jun Li Yuan Huang Xin Qin Yun-tao Liu Zu-yue Hao 《Radiation Detection Technology and Methods》 CSCD 2020年第3期277-283,共7页
Purpose Chinese Spallation Neutron Source(CSNS)is one of the key projects of China,in which the main magnet power supplies adopt the structures of resonant networks(Wang et al.in Sci China Phys Mech Astron 54(Suppl 2)... Purpose Chinese Spallation Neutron Source(CSNS)is one of the key projects of China,in which the main magnet power supplies adopt the structures of resonant networks(Wang et al.in Sci China Phys Mech Astron 54(Suppl 2):239-244,2011).Since each network contains a lot of components,and the working state of all the components will affect the whole accelerator,it is necessary to monitor the operation of each part in the resonant network.Methods In this protections system,a supervision to 314 switch signals and 118 analog signals is realized using a chip of field programmable gate array(FPGA).The details about the hardware and software designs are introduced in this paper.Results This protection system has been used in CSNS project,and the result proves that the RCS has been well monitored by this system.Conclusions This system is a self-developed protection system according to the engineering needs of CSNS.It can realize the real-time monitoring and protection of the working state of resonance network by processing a large number of data using FPGA. 展开更多
关键词 CSNS Resonant network Protection system Magnet power supply
原文传递
Power supply arm protection scheme of high-speed railway based on wide-area current differential
19
作者 Guosong Lin Bin Hong +1 位作者 Zefang Wu Xuguo Fu 《Railway Engineering Science》 2023年第3期281-292,共12页
When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads t... When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads to an extended power failure.Based on equivalent circuit and Kirchhoff’s current law,the feeder current characteristic in the substation,AT station and sectioning post when T-R fault,F-R fault,and T-F fault occur are analyzed and their expressions are obtained.When the traction power supply system is equipped with wide-area protection measurement and control system,the feeder protection device in each station collects the feeder currents in other two stations through the wide-area protection channel and a wide-area current differential protection scheme based on the feeder current characteristic is proposed.When a short-circuit fault occurs in the power supply arm,all the feeder protection devices in each station receive the feeder currents with time stamp in other two stations.After data synchronous processing and logic judgment,the fault line of the power supply arm can be identified and isolated quickly.The simulation result based on MATLAB/Simulink shows that the power supply arm protection scheme based on wide-area current differential has good fault discrimination ability under different fault positions,transition resistances,and fault types.The verification of measured data shows that the novel protection scheme will not be affected by the special working conditions of the electrical multiple unit(EMU),and reliability,selectivity,and rapidity of relay protection are all improved. 展开更多
关键词 Cross-coupling AT power supply Wide-area current differential power supply arm protection Equivalent circuit High-Speed railway
下载PDF
Operation Control Method of Relay Protection in Flexible DC Distribution Network Compatible with Distributed Power Supply
20
作者 Zihan Qi 《Energy Engineering》 EI 2023年第11期2547-2563,共17页
A novel operation control method for relay protection in flexible DC distribution networks with distributed power supply is proposed to address the issue of inaccurate fault location during relay protection,leading to... A novel operation control method for relay protection in flexible DC distribution networks with distributed power supply is proposed to address the issue of inaccurate fault location during relay protection,leading to poor performance.The method combines a fault-tolerant fault location method based on long-term and short-term memory networks to accurately locate the fault section.Then,an operation control method for relay protection based on adaptive weight and whale optimization algorithm(WOA)is used to construct an objective function considering the shortest relay protection action time and the smallest impulse current.The adaptive weight and WOA are employed to obtain the optimal strategy for relay protection operation control,reducing the action time and impulse current.Experimental results demonstrate the effectiveness of the proposed method in accurately locating faults and improving relay protection performance.The longest operation time is reduced by 4.7023 s,and the maximum impulse current is limited to 0.3 A,effectively controlling the impact of large impulse currents and enhancing control efficiency. 展开更多
关键词 Compatible distributed power supply FLEXIBILITY DC distribution network relay protection operation control
下载PDF
上一页 1 2 12 下一页 到第