期刊文献+
共找到15篇文章
< 1 >
每页显示 20 50 100
A CSMA/CA based MAC protocol for hybrid Power-line/Visible-light communication networks:Design and analysis
1
作者 Sheng Hao Huyin Zhang +2 位作者 Fei Yang Chenghao Li Jing Wang 《Digital Communications and Networks》 SCIE CSCD 2024年第2期481-497,共17页
Hybrid Power-line/Visible-light Communication(HPVC)network has been one of the most promising Cooperative Communication(CC)technologies for constructing Smart Home due to its superior communication reliability and har... Hybrid Power-line/Visible-light Communication(HPVC)network has been one of the most promising Cooperative Communication(CC)technologies for constructing Smart Home due to its superior communication reliability and hardware efficiency.Current research on HPVC networks focuses on the performance analysis and optimization of the Physical(PHY)layer,where the Power Line Communication(PLC)component only serves as the backbone to provide power to light Emitting Diode(LED)devices.So designing a Media Access Control(MAC)protocol remains a great challenge because it allows both PLC and Visible Light Communication(VLC)components to operate data transmission,i.e.,to achieve a true HPVC network CC.To solve this problem,we propose a new HPC network MAC protocol(HPVC MAC)based on Carrier Sense Multiple Access/Collision Avoidance(CSMA/CA)by combining IEEE 802.15.7 and IEEE 1901 standards.Firstly,we add an Additional Assistance(AA)layer to provide the channel selection strategies for sensor stations,so that they can complete data transmission on the selected channel via the specified CSMA/CA mechanism,respectively.Based on this,we give a detailed working principle of the HPVC MAC,followed by the construction of a joint analytical model for mathematicalmathematical validation of the HPVC MAC.In the modeling process,the impacts of PHY layer settings(including channel fading types and additive noise feature),CSMA/CA mechanisms of 802.15.7 and 1901,and practical configurations(such as traffic rate,transit buffer size)are comprehensively taken into consideration.Moreover,we prove the proposed analytical model has the solvability.Finally,through extensive simulations,we characterize the HPVC MAC performance under different system parameters and verify the correctness of the corresponding analytical model with an average error rate of 4.62%between the simulation and analytical results. 展开更多
关键词 Hybrid power-line/Visible light communication (HPVC)networks MAC protocol CSMA/CA IEEE 802.15.7 IEEE 1901 Performance analysis
下载PDF
Polar codes based OFDM-PLC systems in the presence of impulsive noise
2
作者 周玉 LI Yue +4 位作者 ZHAO Shuangshuang GAO Fan ZHOU Chao MU Zhuowen CHEN Rui 《High Technology Letters》 EI CAS 2024年第2期188-198,共11页
Power line communication(PLC)has the potential to become the preferred technique for providing broadband communication to homes and offices with advantage of eliminating the need for new wiring infrastructure and redu... Power line communication(PLC)has the potential to become the preferred technique for providing broadband communication to homes and offices with advantage of eliminating the need for new wiring infrastructure and reducing the cost.But it suffers from the impulsive noise because it introduces significant time variance into the power line channel.In this paper,a polar codes based orthogonal frequency division multiplexing(OFDM)PLC system is proposed to deal with the impulsive noise and thereby improve the transmission performance.Firstly,the impulsive noise is modelled with a multi-damped sine function by analyzing the time behavior of impulse events.Then the polar codes are used to combat the impulsive noise of PLC channel,and a low complexity bit-flipping decoding method based on CRC-aided successive cancellation list(CA-SCL)decoding algorithm is proposed.Simulations evaluate the proposed decoding algorithm and the results validate the suggested polar codes based OFDM-PLC scheme which can improve the BER performance of PLC with impulsive interference. 展开更多
关键词 orthogonal frequency division multiplexing(OFDM) polar code impulsivenoise power line communication(plc) bit-flipping
下载PDF
Performance Evaluation for Medium Voltage MIMO-OFDM Power Line Communication System 被引量:10
3
作者 Yingxue Li Min Zhang +3 位作者 Wenguang Zhu Mengyuan Cheng Cheng Zhou Yongpeng Wu 《China Communications》 SCIE CSCD 2020年第1期151-162,共12页
Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)s... Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC. 展开更多
关键词 power line communication(plc) MIMO-OFDM multi-conductor medium voltage underground cables turbo code
下载PDF
Modeling of OFDM Based Transceiver for Broadband Powerline Communication 被引量:1
4
作者 Syed Samser Ali Amitabha Bhattacharya Dipak Ranjan Poddar 《Journal of Electromagnetic Analysis and Applications》 2014年第6期125-129,共5页
In the recent past power line communication has emerged as an attractive choice for high speed data transfer and is looked upon as inexpensive and reliable media suitable for broadband internet access, home and office... In the recent past power line communication has emerged as an attractive choice for high speed data transfer and is looked upon as inexpensive and reliable media suitable for broadband internet access, home and office automation, in-vehicle data communication etc. In this paper we present an architecture for the physical layer of a PLC transceiver based on Orthogonal Frequency Division Multiplexing (OFDM) and the impact on multipath distortion for PLC transmission in terms of bit error rate. Since there is no standard PLC channel model available, a widely accepted multipath channel model is used for simulation purpose. Simulation results as well as FPGA synthesis verify the effectiveness of the proposed architecture for PLC modem design at 110 Mbps data rate. 展开更多
关键词 OFDM Power LINE communication (plc) MULTIPATH CHANNEL FPGA
下载PDF
Traffic Modeling of a Finite-Source Power Line Communication Network
5
作者 Shensheng Tang 《Smart Grid and Renewable Energy》 2011年第3期261-270,共10页
Power line communication (PLC) is a promising smart grid application for information transmission using existing power lines. We analytically model a finite-source PLC network subject to channel failure through a queu... Power line communication (PLC) is a promising smart grid application for information transmission using existing power lines. We analytically model a finite-source PLC network subject to channel failure through a queueing theoretic framework. The proposed PLC network model consists of a base station (BS), which is located at a transformer station and connected to the backbone communication networks, and a number of subscriber stations that are interconnected with each other and with the BS via the power line transmission medium. An orthogonal frequency division multiplexing based technique is assumed for forming the transmission channels in a frequency spectrum. The channels are subject to failure during service due to noise. We determine the steady-state solution of the proposed model and derive a set of performance metrics of interest. Numerical and simulation results are presented to provide further insights into the analytical results. The proposed modeling method is expected to be used for evaluation and design of future PLC networks. 展开更多
关键词 Power LINE communication (plc) Performance Modeling MARKOV Process CHANNEL FAILURE
下载PDF
The Design of VLC-PLC System for Substation Inspection 被引量:3
6
作者 De-Dong Sun Tao-Rong Gong +2 位作者 Rui Liu Jian Song Guan-Hong Wang 《Energy and Power Engineering》 2017年第4期581-588,共8页
A kind of integrated network architecture visible light communication (VLC) and power line communication (PLC) is put forward. This architecture is low cost and easy to implement which overcomes the shortcoming of the... A kind of integrated network architecture visible light communication (VLC) and power line communication (PLC) is put forward. This architecture is low cost and easy to implement which overcomes the shortcoming of the traditional network architecture. Furthermore, the VLC-PLC integration technology is applied to typical power grid business scene, which is substation intelligent inspection. The business process of master station platform is analyzed. During the intelligent inspection, the VLC-PLC system provides voice communication for on-site inspection personnel and management personnel, and position service. The system can ensure the safety and security of power production. 展开更多
关键词 VLC plc INTELLIGENT INSPECTION VOICE communication LOCATION Service
下载PDF
A Novel Device for Real-Time Monitoring of High Frequency Phenomena in CENELEC PLC Band
7
作者 Bashir Ahmed Siddiqui Pertti Pakonen Pekka Verho 《Smart Grid and Renewable Energy》 2012年第2期152-157,共6页
This paper proposes the design and development of a novel, portable and low-cost intelligent electronic device (IED) for real-time monitoring of high frequency phenomena in CENELEC PLC band. A high speed floating-poin... This paper proposes the design and development of a novel, portable and low-cost intelligent electronic device (IED) for real-time monitoring of high frequency phenomena in CENELEC PLC band. A high speed floating-point digital signal processor (DSP) along with 4 MSPS analog-to-digital converter (ADC) is used to develop the intelligent electronic device. An optimized algorithm to process the analog signal in real-time and to extract the meaningful result using signal processing techniques has been implemented on the device. A laboratory environment has setup with all the necessary equipment including the development of the load model to evaluate the performance of the IED. Smart meter and concentrator is also connected to the low voltage (LV) network to monitor the PLC communication using the IED. The device has been tested in the laboratory and it has produced very promising results for time domain as well as frequency domain analysis. Those results imply that the IED is fully capable of monitoring high frequency disturbances in CENELEC PLC band. 展开更多
关键词 Power Line communication (plc) DIGITAL Signal PROCESSOR (DSP) Analog-to-Digital Converter (ADC) Fast FOURIER TRANSFORM (FFT) High Frequency (HF) Interference
下载PDF
Particle filtering based channel estimation in OFDM power line communication 被引量:4
8
作者 ZHANG Pei-ling ZHANG Hong-xin +3 位作者 LIU Hong-da ZHANG Yu-jing HE Peng-fei PANG Xue-li 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2014年第5期24-30,42,共8页
Particle filtering (PF) algorithm has the powerful potential for coping with difficult non-linear and non-Gaussian problems. Aiming at non-linear, non-Gaussian and time-varying characteristics of power line channel,... Particle filtering (PF) algorithm has the powerful potential for coping with difficult non-linear and non-Gaussian problems. Aiming at non-linear, non-Gaussian and time-varying characteristics of power line channel, a time-varying channel estimation scheme combined PF algorithm with decision feedback method is proposed. In the proposed scheme, firstly the indoor power line channel is measured using the pseudo-noise (PN) correlation method, and a first-order dynamic autoregressive (AR) model is set up to describe the measured channel, then, the channel states are estimated dynamically from the received signals by exploiting the proposed scheme. Meanwhile, due to the complex noise distribution of power line channel, the performance of channel estimation based on the proposed scheme under the Middleton class A impulsive noise environment is analyzed. Comparisons are made with the channel estimation scheme respectively based on least square (LS), Kalman filtering (KF) and the proposed algorithm. Simulation indicates that PF algorithm dealing with this power line channel estimation difficult non-linear and non-Gaussian problems performance is superior to those of LS and KF respectively, so the proposed scheme achieves higher estimation accuracy. Therefore, it is confirmed that PF algorithm has its own unique advantage for power line channel estimation. 展开更多
关键词 power line communication plc orthogonal frequency division multiplexing (OFDM) channel estimation PF KF
原文传递
The Designed Operation of the Machine Control System on HL-2A Tokamak 被引量:1
9
作者 李强 樊明杰 +4 位作者 宋显明 王明红 唐芳群 罗萃文 袁保山 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第5期2985-2988,共4页
The Ethernet and field-bus communications are used in the machine control system (MCS) of HL-2A. The control net, with a programmable logic controller (PLC) as its logic control master, an engineering control mana... The Ethernet and field-bus communications are used in the machine control system (MCS) of HL-2A. The control net, with a programmable logic controller (PLC) as its logic control master, an engineering control management station as its net server, and a timing control PC connected to a number of terminals, flexibly and freely transfers information among the nodes on it with the Ethernet transmission techniques. The PLC masters the field bus, which carries small pieces of information between PLC and the field sites reliably and quickly. The control net is connected into the data net, where Internet access and sharing of more experimental data are enabled. The communication in the MCS guarantees the digitalization, automation and centralization. Also provided are a satisfactory degree of safety, reliability, stability, expandability and flexibility for maintenance. 展开更多
关键词 communication programmable logic controller plc machine control system HL-2A tokamak
下载PDF
Broadband hybrid model for relay-aided cooperative MIMO power line communication systems
10
作者 Liang Xiaolin Cao Wangbin 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2020年第1期72-80,共9页
A hybrid model for broadband multiple-input multiple-output(MIMO) relay-aided indoor power line communications(PLC) system was proposed in this paper. The proposed model combines the top-down and bottom-up approaches ... A hybrid model for broadband multiple-input multiple-output(MIMO) relay-aided indoor power line communications(PLC) system was proposed in this paper. The proposed model combines the top-down and bottom-up approaches and extends to a two-hop relay-aided cooperative system with variable gain relay in amplify-and-forward(AF) mode. Based on the proposed PLC model and generated channel, the channel statistical characteristics are further investigated in 2 MHz^100 MHz bandwidth. Simulated results show that the proposed model overcomes the difficulties that the existing models need a lot of topological information of the network or measurements information. It provides a practical simulation analysis method for cooperative relay MIMO-PLC system. The results also show that cooperative MIMO relaying communications can improve the indoor PLC performances and communication reliability. 展开更多
关键词 BROADBAND communication channel frequency response(CFR) hybrid model MIMO-plc power line communications(plc) relay-aided
原文传递
Two-Way Digital Video Transmission over Medium-Voltage Power-Lines Using Time-Domain Synchronous Orthogonal Frequency Division Multiplexing Technology
11
作者 宋健 吴青 +4 位作者 潘长勇 杨知行 刘海涛 赵丙镇 李晓 《Tsinghua Science and Technology》 SCIE EI CAS 2008年第6期784-789,共6页
This paper describes field trials of two-way digital video transmissions over a 700-m long medium-voltage power cable using a frequency division duplex scheme. The purpose is to check the feasibility of using time-dom... This paper describes field trials of two-way digital video transmissions over a 700-m long medium-voltage power cable using a frequency division duplex scheme. The purpose is to check the feasibility of using time-domain synchronous orthogonal frequency division multiplexing (TDS-OFDM) technology in powerline communication (PLC). TDS-OFDM is the core technology in digital multimedia broadcasting-terrestrial (DMB-T), developed by Tsinghua University for digital television terrestrial multimedia broadcast applications and successfully adopted in the Chinese Digital Terrestrial Television Broadcasting Standard. PLC systems are widely believed to be bandwidth or data throughput limited. However, the use of known pseudo random sequences as guard intervals for synchronization and channel estimation in TDS-OFDM greatly reduces the system overhead and increases the spectrum efficiency. These experiments show that TDS-OFDM is appropriate not only for broadcasting but also for PLC applications with appropriate modifications. 展开更多
关键词 time-domain synchronous orthogonal frequency division multiplexing (TDS-OFDM) powerline communications plc digital multimedia broadcasting-terrestrial (DMB-T)
原文传递
A Dual Detection Method for Siemens Inverter Motor Modbus RTU Attack
12
作者 Yong Wan Xiunan Feng +3 位作者 Yixuan Chen Lin Zhou Yiwen Zhu Jinyuan Wu 《Journal of Computer and Communications》 2021年第7期91-108,共18页
Since the Modbus RTU wired communication protocol of Siemens variable frequency motors is unstable and lacks a protection mechanism, there is a risk of user information leakage. Aiming at the problems of insufficient ... Since the Modbus RTU wired communication protocol of Siemens variable frequency motors is unstable and lacks a protection mechanism, there is a risk of user information leakage. Aiming at the problems of insufficient flexibility of traditional defense methods and poor defense effects, The present work proposed a new dual detection method based on MODBUS RTU, which combines the dual monitoring mechanism of “Address Resolution Protocol (ARP) request detection” and “ARP response detection”. In order to improve detection efficiency, two real-time updated linear tables are introduced, which can effectively deal with the three ARP spoofing methods of updating the ARP buffer. Based on the analysis of the hidden dangers of the Modbus RTU wired communication protocol, a wired connection between the S7-1200 PLC and the variable frequency motor was established, and a real experimental platform was constructed to demonstrate the attack. The intensity of ARP attacks has gradually increased over time. Through comparative experiments with traditional defense methods, it is proved that the algorithm enhances the protocol mechanism in principle, and is more flexible and reliable than traditional methods. 展开更多
关键词 Siemens Motor Man-in-the-Middle (MITM) Attack S7-1200plc Modbus RTU communication Protocol
下载PDF
Smart Home Networking: Lessons from Combining Wireless and Powerline Networking
13
作者 Cheng Jin Thomas Kunz 《Smart Grid and Renewable Energy》 2011年第2期136-151,共16页
Integrating the power grid technology with renewable power generation technologies, Demand Response (DR) programs enabled by the Advanced Metering Infrastructure (AMI) were introduced into the power grid in the intere... Integrating the power grid technology with renewable power generation technologies, Demand Response (DR) programs enabled by the Advanced Metering Infrastructure (AMI) were introduced into the power grid in the interest of both utilities and residents. They help to achieve load balance and increase the grid reliability by encouraging residents to reduce their power usage during peak load periods in return for incentives. To automate this process, appliances, in-house sensors, and the AMI controller need to be networked together. In this paper, we compare mainstream network technologies applicable to home appliance control and propose a solution combining Power Line Communication (PLC) with wireless communication in smart homes for the purpose of energy saving. We extended NS-2, a popular network simulator, to model such combined network scenarios. Using a number of different routing strategies, we then model and evaluate the network performance of DR programs in smart homes in such a combined network. 展开更多
关键词 Demand Response (DR) Advanced METERING Infrastructure (AMI) POWER Line communication (plc) Network Simulator Version-2 (NS-2) MULTI-INTERFACE Networking Multi-Network Simulations
下载PDF
A novel PLC channel modeling method and channel characteristic analysis of a smart distribution grid 被引量:7
14
作者 Jian Le Cao Wang +2 位作者 Wu Zhou Yong-yan Liu Wei Cai 《Protection and Control of Modern Power Systems》 2017年第1期146-158,共13页
Power line carrier(PLC)technology plays an increasingly important role in the realization of cost-effective communication in a smart distribution grid.No current channel modeling method is universally applicable to mo... Power line carrier(PLC)technology plays an increasingly important role in the realization of cost-effective communication in a smart distribution grid.No current channel modeling method is universally applicable to more complex topologies that may emerge in smart grids,such as ring and mesh topologies.This paper presents a novel PLC channel modeling method based on the information node concept,and the universality and feasibility of the proposed method are demonstrated with applications in modeling networks with ring and mesh topologies.The factors that affect the channel characteristics of the networks and the laws that govern their behaviors for different types of topologies are analyzed.The validity and effectiveness of the proposed method are proven using simulation and laboratory tests.This paper provides the necessary theoretical basis and technical means to design the PLC modulation method for smart distribution grids. 展开更多
关键词 Smart distribution grid Transfer matrix power-line communication Information nodes Channel characteristics
原文传递
LDPC Coded TDS-OFDM for PLC Systems
15
作者 戴凌龙 符剑 王军 《Tsinghua Science and Technology》 SCIE EI CAS 2010年第3期312-318,共7页
Powerline communications (PLC) have drawn great interest in recent years. However, most PLC standards such as HomePlug AV use the cyclic-prefix OFDM (CP-OFDM) technology. This paper presents a broadband PLC system... Powerline communications (PLC) have drawn great interest in recent years. However, most PLC standards such as HomePlug AV use the cyclic-prefix OFDM (CP-OFDM) technology. This paper presents a broadband PLC system using low density parity check (LDPC) coded time domain synchronous OFDM (TDS-OFDM), whose spectrum efficiency is about 10% higher than that of CP-OFDM. With the same bandwidth and the ability to combat the time delay spread as HomePlug AV, this system can provide a maximum throughput of 199.7 Mbps physical layer data rate. Simulations over the measured practical powerline channel in Beijing, China, show that LDPC in the TDS-OFDM system dramatically improves the bit error rate performance, and verify the feasibility and performance of the TDS-OFDM technology for PLC systems. 展开更多
关键词 powerline communications plc time domain synchronous OFDM (TDS-OFDM) low density parity check (LDPC) HomePlug AV channel measurement
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部