This paper aims to discuss the application of eye surgery preparation room( ESPR),also called eye preoperative holding area,in nursing safety assessment and the surgery preparation before ophthalmologic operation. The...This paper aims to discuss the application of eye surgery preparation room( ESPR),also called eye preoperative holding area,in nursing safety assessment and the surgery preparation before ophthalmologic operation. The establishment and application of ESPR optimizes the process of ophthalmologic surgery as w ell as decreases the surgery-w aiting time of patients and turnover period of surgical operations,w hich improves the utilization efficiency of surgery operating room. In addition,the application of ESPR also guarantees the safety of patients during surgical operations and enhances the doctors' satisfaction of cooperation and coordination in surgery operating room.展开更多
γ-ray and x-ray detectors made by Cd1-xZnxTe alloy can gain high energy resolution and detect efficiency at room temperature due to its high atomic number,large energy gap and high density,which were well-developed r...γ-ray and x-ray detectors made by Cd1-xZnxTe alloy can gain high energy resolution and detect efficiency at room temperature due to its high atomic number,large energy gap and high density,which were well-developed recently.By well controlled of Cadmium partial pressure and compensatory doping technique,Ф90 mm Cd1-xZnxTe alloy obtained successfully(ρ≥1011Ω·cm)by an improved-Bridgman method.3 mm×3 mm×3 mm CZT detector was made at Kunming Institute of Physics,which has energy resolution of 3.52%(FWHM)at room temperature when detect 59.54 KeV Am241γ-ray source.展开更多
文摘This paper aims to discuss the application of eye surgery preparation room( ESPR),also called eye preoperative holding area,in nursing safety assessment and the surgery preparation before ophthalmologic operation. The establishment and application of ESPR optimizes the process of ophthalmologic surgery as w ell as decreases the surgery-w aiting time of patients and turnover period of surgical operations,w hich improves the utilization efficiency of surgery operating room. In addition,the application of ESPR also guarantees the safety of patients during surgical operations and enhances the doctors' satisfaction of cooperation and coordination in surgery operating room.
文摘γ-ray and x-ray detectors made by Cd1-xZnxTe alloy can gain high energy resolution and detect efficiency at room temperature due to its high atomic number,large energy gap and high density,which were well-developed recently.By well controlled of Cadmium partial pressure and compensatory doping technique,Ф90 mm Cd1-xZnxTe alloy obtained successfully(ρ≥1011Ω·cm)by an improved-Bridgman method.3 mm×3 mm×3 mm CZT detector was made at Kunming Institute of Physics,which has energy resolution of 3.52%(FWHM)at room temperature when detect 59.54 KeV Am241γ-ray source.