期刊文献+
共找到17篇文章
< 1 >
每页显示 20 50 100
Resilience-incorporated seismic risk assessment of precast concrete frames with“dry”connections
1
作者 Wu Chenhao Tang Yuchuan +1 位作者 Cao Xuyang Wu Gang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期403-425,共23页
A resilience-incorporated risk assessment framework is proposed and demonstrated in this study to manifest the advantageous seismic resilience of precast concrete frame(PCF)structures with“dry”connections in terms o... A resilience-incorporated risk assessment framework is proposed and demonstrated in this study to manifest the advantageous seismic resilience of precast concrete frame(PCF)structures with“dry”connections in terms of their low damage and rapid recovery.The framework integrates various uncertainties in the seismic hazard,fragility,capacity,demand,loss functions,and post-earthquake recovery.In this study,the PCF structures are distinguished from ordinary reinforced concrete frame(RCF)structures by characterizing multiple limit states for the PCF based on its unique damage mechanisms.Accordingly,probabilistic story-wise pushover analyses are performed to yield story-wise capacities for the predefined limit states.In the seismic resilience analysis,a step-wise recovery model is proposed to idealize the functionality recovery process,with separate considerations of the repair and non-repair events.The recovery model leverages the economic loss and downtime to delineate the stochastic post-earthquake recovery curves for the resilience loss estimation.As such,contingencies in the probabilistic post-earthquake repairs are incorporated and the empirical judgments on the recovery parameters are largely circumvented.The proposed framework is demonstrated through a comparative study between two“dry”connected PCFs and one RCF designed as alternative structural systems for a prototype building.The results from the risk quantification indicate that the PCFs show reduced loss hazards and lower expected losses relative to the RCF.Particularly,the PCF equipped with energy dissipation devices at the“dry”connections largely reduces the expected economic loss,downtime,and resilience loss by 29%,56%,and 60%,respectively,compared to the RCF. 展开更多
关键词 precast concrete frame non-emulative precast system seismic resilience seismic risk functional recovery
下载PDF
Cyclic performance and simplified pushover analyses of precast segmental concrete bridge columns with circular section 被引量:11
2
作者 Bu Zhanyu Guo Jian +2 位作者 Zheng Rongyue Song Jianwei George C.Lee 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第2期297-312,共16页
In recent years, precast segmental concrete bridge columns became prevalent because of the benefits of accelerated construction, low environmental impact, high quality and low life cycle costs. The lack of a detailed ... In recent years, precast segmental concrete bridge columns became prevalent because of the benefits of accelerated construction, low environmental impact, high quality and low life cycle costs. The lack of a detailed configuration and appropriate design procedure to ensure a comparable performance with monolithic construction has impeded this structural system from being widely used in areas of high seismicity. In this study, precast segmental bridge column cyclic loading tests were conducted to investigate the performance of unbonded post-tensioned segmental bridge columns. One monolithic and two precast segmental columns were tested. The preeast segmental column exhibited minor damage and small residual displacement after the maximum 7% cyclic drift; energy dissipation (ED) can be enhanced byadding ED bars. The experimental results were modeled by a simplified pushover method (SPOM), as well as a fiber model (FIBM) finite element method. Forty-five cases of columns with different aspect ratios, axial load ratios and ED bar ratios were analyzed with the SPOM and FIBM, respectively. Using these parametric results, a simplified design method was suggested by regressive analysis. Satisfactory correlation was found between the experimental results and the simplified design method for preeast segmental columns with different design parameters. 展开更多
关键词 precast concrete segmental column simplified pushover fiber model
下载PDF
Development of a new connection for precast concrete walls subjected to cyclic loading 被引量:8
3
作者 Ramin Vaghei Farzad Hejazi +2 位作者 Hafez Taheri Mohd Saleh Jaafar Farah Nora Aznieta Abdul Aziz 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第1期97-117,共21页
The Industrialized Building System (IBS) was recently introduced to minimize the time and cost of project construction. Accordingly, ensuring the integration of the connection of precast components in IBS structures... The Industrialized Building System (IBS) was recently introduced to minimize the time and cost of project construction. Accordingly, ensuring the integration of the connection of precast components in IBS structures is an important factor that ensures stability of buildings subjected to dynamic loads from earthquakes, vehicles, and machineries. However, structural engineers still lack knowledge on the proper connection and detailed joints o fiBS structure construction. Therefore, this study proposes a special precast concrete wall-to-wall connection system for dynamic loads that resists multidirectional imposed loads and reduces vibration effects (PI2014701723). This system is designed to connect two adjacent precast wall panels by using two steel U-shaped channels (i.e., male and female joints). During casting, each joint is adapted for incorporation into a respective wall panel after considering the following conditions: one side of the steel channel opens into the thickness face of the panel; a U-shaped rubber is implemented between the two channels to dissipate the vibration effect; and bolts and nuts are used to create an extension between the two U-shaped male and female steel channels. The developed finite element model of the precast wall is subjected to cyclic loads to evaluate the performance of the proposed connection during an imposed dynamic load. Connection performance is then compared with conventional connections based on the energy dissipation, stress, deformation, and concrete damage in the plastic range. The proposed precast connection is capable of exceeding the energy absorption of precast walls subjected to dynamic load, thereby improving its resistance behavior in all principal directions. 展开更多
关键词 industrial building system precast concrete structure precast wall connection finite element method nonlinear analysis energy dissipation concrete damage plasticity
下载PDF
Seismic performance of interior precast concrete beam-column connections with T-section steel inserts under cyclic loading 被引量:15
4
作者 Rattapon Ketiyot Chayanon Hansapinyo 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第2期355-369,共15页
An experimental investigation was conducted to study the performance of precast beam-column concrete connections using T-section steel inserts into the concrete beam and joint core,under reversed cyclic loading.Six 2/... An experimental investigation was conducted to study the performance of precast beam-column concrete connections using T-section steel inserts into the concrete beam and joint core,under reversed cyclic loading.Six 2/3-scale interior beam-column subassemblies,one monolithic concrete specimen and five precast concrete specimens were tested.One precast specimen was a simple connection for a gravity load resistant design.Other precast specimens were developed with different attributes to improve their seismic performance.The test results showed that the performance of the monolithic specimen M1 represented ductile seismic behavior.Failure of columns and joints could be prevented,and the failure of the frame occurred at the flexural plastic hinge formation at the beam ends,close to the column faces.For the precast specimens,the splitting crack along the longitudinal lapped splice was a major failure.The precast P5 specimen with double steel T-section inserts showed better seismic performance compared to the other precast models.However,the dowel bars connected to the steel inserts were too short to develop a bond.The design of the precast concrete beams with lap splice is needed for longer lap lengths and should be done at the beam mid span or at the low flexural stress region. 展开更多
关键词 precast concrete beam-column connection cyclic loading
下载PDF
Simplified full-depth precast concrete deck panel systems for accelerated bridge construction 被引量:4
5
作者 Zhongguo John Ma Yulin Zhan +2 位作者 Lin Xiao Lungui Li Weiwei Lu 《Journal of Modern Transportation》 2016年第4期251-260,共10页
A simplified full-depth precast concrete deck panel system for accelerating bridge construction (ABC) is introduced and a finite dement analysis (FEA) is con- ducted to investigate the static and dynamic responses... A simplified full-depth precast concrete deck panel system for accelerating bridge construction (ABC) is introduced and a finite dement analysis (FEA) is con- ducted to investigate the static and dynamic responses of this conceptual deck system. The FEA results are compared to those of the traditional full-depth precast concrete deck panel system. The comparison results show that the mechanical behavior of the new deck system is different from that of the traditional deck system. The concrete decks in the new system act as two-way slabs, instead of the one-way slab in the traditional system. Meanwhile, the connections in both the longitudinal and transverse direc- tions may need to accommodate the negative moments. Compared to those in the traditional system, the longitu- dinal nominal stress at middle span increases a lot in the new deck system and the effective flange width varies significantly. In addition, the dynamic results show that the impact factor is influenced by the spacing of connections. Finally, some design concerns of the new deck system are proposed. 展开更多
关键词 Simplified full-depth precast concrete deckpanel systems ~ Accelerated bridge construction ~ Structuralresponse
下载PDF
BIM-based construction technologies for precast foamed lightweight concrete wallboards 被引量:1
6
作者 Lin Jiankang Chen Zhongfan +2 位作者 Ding Xiaomeng Feng Yan Zhang Jiaheng 《Journal of Southeast University(English Edition)》 EI CAS 2022年第3期270-277,共8页
To promote the visualisation and informatisation of the construction process of precast foamed lightweight concrete wallboards(PFLCWs),from the analysis of the construction requirements of PFLCWs,three key constructio... To promote the visualisation and informatisation of the construction process of precast foamed lightweight concrete wallboards(PFLCWs),from the analysis of the construction requirements of PFLCWs,three key construction technologies based on building information modelling(BIM),namely,parameterised modelling for the PFLCW layout design,drawing generation to draw the PFLCW layout and quantity statistics for extracting PFLCW quantities,are proposed.Then,a reinforced concrete(RC)frame infilled with PFLCW is considered the test model to verify the feasibility of the aforementioned technologies.The results show that PFLCW layout design can be accomplished rapidly and visually using parameterised modelling technology.The PFLCW layout diagram can be generated directly using drawing generation technology.The proposed quantity statistics technology enables the automatic export of PFLCW bills of quantities.The built parameterised model helps construction workers rapidly and intuitively understand the specific layout details of PFLCWs.Moreover,the generated layout drawing and the bills of quantities based on the parameterised model can guide the production and on-site installation of PFLCWs.The research conclusions can serve as a practical guide and technical support for PFLCW engineering applications. 展开更多
关键词 building information modelling(BIM) precast foamed lightweight concrete wallboard(PFLCW) construction visualisation and informatisation parameterised modelling quantity statistics
下载PDF
Cyclic test and numerical study of seismic performance of precast segmental concrete double-columns
7
作者 ZOU Shuang WENLIUHAN Hei-sha +2 位作者 MAO Yong-ping YU Bi-peng ZHANG Chong-bin 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第8期2502-2512,共11页
The comparative research on the seismic performance of grouted sleeve connected pier(GS)and prestressed precast segmental concrete pier(PC)is mostly carried out by numerical simulation.In this study,the GS pier and th... The comparative research on the seismic performance of grouted sleeve connected pier(GS)and prestressed precast segmental concrete pier(PC)is mostly carried out by numerical simulation.In this study,the GS pier and the PC pier of the new railway project from Hetian to Ruoqiang are taken into consideration.Two kinds of 1/5-scale assembled double-column specimens are made,and the quasi-static tests are carried out.The overall seismic performance of the two spliced piers is studied,and compared in terms of failure mechanism,bearing capacity,ductility,stiffness and energy dissipation capacity.The results show that the failure modes of both GS pier and PC pier are characterized by bending.However,the specific failure location and form are different.The GS pier presents a complete hysteretic curve,large equivalent stiffness and strong energy dissipation capacity.The hysteretic area of the PC pier is small.However,it has good self-reset ability and quasi-static residual displacement.Finite element models are set up using DispBeamColumn fiber elements and ZeroLength elements.The models that are calibrated with the test data can effectively simulate the damage development under monotonic loading.The load−displacement curves are in good agreement with the backbone curves of the test results. 展开更多
关键词 pseudo static test seismic performance prestressed precast segmental concrete double-column piers steel sleeve connection precast concrete prestressed steel
下载PDF
Substructure hybrid testing of reinforced concrete shear wall structure using a domain overlapping technique 被引量:1
8
作者 Zhang Yu Pan Peng +2 位作者 Gong Runhua Wang Tao Xue Weichen 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第4期761-772,共12页
An online hybrid test was carried out on a 40-story 120-m high concrete shear wall structure. The structure was divided into two substructures whereby a physical model of the bottom three stories was tested in the lab... An online hybrid test was carried out on a 40-story 120-m high concrete shear wall structure. The structure was divided into two substructures whereby a physical model of the bottom three stories was tested in the laboratory and the upper 37 stories were simulated numerically using ABAQUS. An overlapping domain method was employed for the bottom three stories to ensure the validity of the boundary conditions of the superstructure. Mixed control was adopted in the test. Displacement control was used to apply the horizontal displacement, while two controlled force actuators were applied to simulate the overturning moment, which is very large and cannot be ignored in the substructure hybrid test of high-rise buildings. A series of tests with earthquake sources of sequentially increasing intensities were carried out. The test results indicate that the proposed hybrid test method is a solution to reproduce the seismic response of high-rise concrete shear wall buildings. The seismic performance of the tested precast high-rise building satisfies the requirements of the Chinese seismic design code. 展开更多
关键词 hybrid test substructure technique domain overlapping method precast concrete building
下载PDF
Operation Phase Problems of Prefabricated Residential Buildings with Integrated Autoclaved Aerated Concrete Panel Walls
9
作者 Stanislaw Fic Danuta Barnat-Hunek 《Journal of Civil Engineering and Architecture》 2015年第3期268-273,共6页
Growing technical problems with the maintenance of precast concrete housing stock result in the search for efficient repair methods. The paper analyses the effects of flaws in the design concept and assembly accuracy ... Growing technical problems with the maintenance of precast concrete housing stock result in the search for efficient repair methods. The paper analyses the effects of flaws in the design concept and assembly accuracy of integrated AAC (autoclaved aerated concrete) panel walls, type GWO (Gazobetonowa Wielka P|yta Ostonowa which means large cover panel from aerated concrete in English), used as curtain walls in a system of precast concrete housing blocks erected in Lublin. The results of in-situ observations and laboratory tests of the panel walls have been described, and the opinion on the further use of these elements has been presented. As for the analysed case, there is no possibility of replacing damaged elements, thus, additional reinforcement with steel tendons has been proposed as a repair measure. 展开更多
关键词 AAC precast concrete housing cracks insulation.
下载PDF
Structural performance of a façade precast concrete sandwich panel enabled by a bar-type basalt fiber-reinforced polymer connector 被引量:1
10
作者 Junqi HUANG Qing JIANG +2 位作者 Xun CHONG Xianguo YE Caihua LIU 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2023年第1期122-137,共16页
In this study,a novel diagonally inserted bar-type basalt fiber reinforced polymer(BFRP)connector was proposed,aiming to achieve both construction convenience and partially composite behavior in precast concrete sandw... In this study,a novel diagonally inserted bar-type basalt fiber reinforced polymer(BFRP)connector was proposed,aiming to achieve both construction convenience and partially composite behavior in precast concrete sandwich panels(PCSPs).First,pull-out tests were conducted to evaluate the anchoring performance of the connector in concrete after exposure to different temperatures.Thereafter,direct shear tests were conducted to investigate the shear performance of the connector.After the test on the individual performance of the connector,five façade PCSP specimens with the bar-type BFRP connector were fabricated,and the out-of-plane flexural performance was tested under a uniformly distributed load.The investigating parameters included the panel length,opening condition,and boundary condition.The results obtained in this study primarily indicated that 1)the bar-type BFRP connector can achieve a reliable anchorage system in concrete;2)the bar-type BFRP connector can offer sufficient stiffness and capacity to achieve a partially composite PCSP;3)the boundary condition of the panel considerably influenced the out-of-plane flexural performance and composite action of the investigated façade PCSP. 展开更多
关键词 precast concrete sandwich panel basalt fiber reinforced polymer pull-out performance shear performance out-of-plane flexural performance
原文传递
Ductility improvement of GFRP-RC beams using precast confined concrete block in compression zone
11
作者 Nooshin G.AMIRABAD Farshid J.ALAEE Meysam JALALI 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2023年第10期1585-1598,共14页
Fiber-reinforced polymers(FRPs)have received considerable research attention because of their high strength,corrosion resistance,and low weight.However,owing to the lack of ductility in this material and the quasi-bri... Fiber-reinforced polymers(FRPs)have received considerable research attention because of their high strength,corrosion resistance,and low weight.However,owing to the lack of ductility in this material and the quasi-brittle behavior of concrete,FRP-reinforced concrete(FRP-RC)beams,even with flexural failure,do not fail in a ductile manner.Because the limited deformation capacity of FRP-RC beams depends on the ductility of their compression zones,the present study proposes using a precast confined concrete block(PCCB)in the compression zone to improve the ductility of the beams.A control beam and four beams with different PCCBs were cast and tested under four-point bending conditions.The control beam failed due to shear,and the PCCBs exhibited different confinements and perforations.The goal was to find an appropriate PCCB for use in the compression zone of the beams,which not only improved the ductility but also changed the failure mode of the beams from shear to flexural.Among the employed blocks,a ductile PCCB with low equivalent compressive strength increased the ductility ratio of the beam to twice that of the control beam.The beam failed in pure flexure with considerable deformation capacity and without significant stiffness reduction. 展开更多
关键词 DUCTILITY four-point bending test glass fiber-reinforced polymer precast confined concrete block
原文传递
Experimental study on out-of-plane seismic performance of precast composite sidewalls of utility tunnel with grouting-sleeve joints
12
作者 Zilan Zhong Guangfan Li +3 位作者 Jinqiang Li Jiaxu Shen Mi Zhao Xiuli Du 《Underground Space》 SCIE EI CSCD 2024年第3期1-17,共17页
The precast composite reinforced concrete wall with the advantages of fewer joints,superior impermeability and rapid construction provides an efficient and environmental friendly alternative in the construction of und... The precast composite reinforced concrete wall with the advantages of fewer joints,superior impermeability and rapid construction provides an efficient and environmental friendly alternative in the construction of underground utility tunnels in the last few years.To investigate the seismic performance of precast concrete composite walls of utility tunnels with grouting-sleeve connection under out-ofplane loads,a series of quasi-static cyclic tests were performed on the full-scale sidewall specimens with different axial compression ratios in this study.The experimental results including the failure modes,crack distributions,and the influence of different connections on the out-of-plane seismic performance of precast concrete composite wall were carefully examined and compared with those from the cyclic tests of the cast-in-place sidewalls of the utility tunnel.The test results show that the seismic performance of the precast concrete composite sidewall specimen,such as the hysteresis curves,the ultimate bearing capacity,stiffness degradation pattern and the ductility ratio,is basically the same as that of the cast-in-place specimen,indicating that the seismic performance of the prefabricated structure is equivalent to that of the cast-in-place structure.Moreover,the grouting-sleeves of the joints can effectively transfer the reinforcement stress until the failure of the precast concrete composite sidewall specimens,which exhibits excellent out-of-plane ductility and serviceability. 展开更多
关键词 precast concrete composite walls Cyclic response Seismic performance Grouting sleeve Failure mechanism
原文传递
Seismic performance of precast hollow bridge piers with different construction details 被引量:8
13
作者 Zhiqiang WANG Jiping GE Hongyi WEI 《Frontiers of Structural and Civil Engineering》 CSCD 2014年第4期399-413,共15页
Currently the design scheme ofprecast hollow concrete bridge piers will be adopted in bridge design in China, but there is no code including specific design details of precast segmental piers in high seismic risk area... Currently the design scheme ofprecast hollow concrete bridge piers will be adopted in bridge design in China, but there is no code including specific design details of precast segmental piers in high seismic risk area. For comparative study of seismic performance of the hollow bridge piers which had different design details, six specimens of hollow section bridge pier were designed and tested. The specimens consist of the monolithic cast-in-place concrete bridge pier, precast segmental prestressed pier with cast-in-place joint and precast segmental concrete bridge pier with dry joints. Results show that all specimens have good displacement capacity. The bridge pier with bonded prestressed strands exhibits better energy dissipation capacity and higher strength. The un-bonded prestressed strand bridge pier displays less residual plastic displacement and energy dissipation capacity. The bridge pier with both bonded prestressed strands at the edge of the section and un-bonded in the center of the section not only exhibits more ductility capacity and less residual plastic displacement, but also shows better energy dissipation capacity. Compared with experimental results of prestressed bridge columns, analytical result demonstrates the developed numerical analysis model would provide the reasonable and accurate results. 展开更多
关键词 hollow pier seismic performance cyclic load precast concrete bridge columns
原文传递
Seismic design and analysis of a high-rise self-centering wallbuilding:Case study
14
作者 Ying ZHOU Rui WANG Yiqiu LU 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2023年第11期1690-1706,共17页
Post-tensioning self-centering walls are a well-developed and resilient technology.However,despite extensive research,the application of this technology has previously been limited to low-rise buildings.A ten-story se... Post-tensioning self-centering walls are a well-developed and resilient technology.However,despite extensive research,the application of this technology has previously been limited to low-rise buildings.A ten-story selfcentering wall building has now been designed and constructed using the state-of-art design methodologies and construction detailing,as described in this paper.The building is designed in accordance with direct displacement-based design methodology,with modification of seismic demand due to relevant issues including higher-mode effects,second order effects,torsional effects,and flexural deformation of wall panels.Wall sections are designed with external energydissipating devices of steel dampers,and seismic performance of such designed self-centering walls is evaluated through numerical simulation.It is the first engineering project that uses self-centering walls in a high-rise building.The seismic design procedure of such a high-rise building,using self-centering wall structures,is comprehensively reviewed in this work,and additional proposals are put forward.Description of construction detailing,including slotted beams,flexible wall-to-floor connections,embedded beams,and damper installation,is provided.The demonstration project promotes the concept of seismic resilient structures and contributes to the most appealing city planning strategy of resilient cities at present.The paper could be a reference for industry engineers to promote the self-centering wall systems worldwide. 展开更多
关键词 self-centering wall post-tensioned precast concrete wall seismic resilient structure high-rise building seismic design engineering practice
原文传递
Long-range laser ranging using superconducting nanowire single-photon detectors 被引量:4
15
作者 薛莉 李明 +10 位作者 张蜡宝 翟东升 李祝莲 康琳 李语强 伏红林 明名 张森 陶旭 熊耀恒 吴培亨 《Chinese Optics Letters》 SCIE EI CAS CSCD 2016年第7期42-46,共5页
We demonstrate laser-ranging results for non-cooperative targets at ranges of 237 m and 19 km using superconducting nanowire single-photon detectors (SSPD). We upgrade the kilohertz rate laser-ranging system with a ... We demonstrate laser-ranging results for non-cooperative targets at ranges of 237 m and 19 km using superconducting nanowire single-photon detectors (SSPD). We upgrade the kilohertz rate laser-ranging system with a newly developed SSPD module, and the equivalent detection diameter is enlarged to 50 gm with a fiber and micro-lenses. Both retroreflectors and non-cooperative surfaces of aluminum foil, a solar panel, and a concrete panel at distances of 237 m and 19 km, whose echoes are of single-photon level, are ranged with sub-centimeter precision. Experimental signal-to-noise ratio curves with the product of quantum efficiency and system transmittance are obtained, which indicates that our system, with an average laser power of 0.8 W and a receiving aperture of 1.2 m, may be capable for space debris ranging at a distance of 800 km. This work suggests that SSPDs have the potential to be used for space debris surveillance. 展开更多
关键词 Avalanche photodiodes concrete slabs MICROLENSES Nanowires PHOTODETECTORS PHOTONS precast concrete Signal to noise ratio Space debris
原文传递
Self-centring segmental retaining walls—A new construction system for retaining walls
16
作者 Mehdi JAVADI Reza HASSANLI +1 位作者 Md Mizanur RAHMAN Md Rajibul KARIM 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2021年第4期980-1000,共21页
This paper reports on an experimental study on a new self-centring retaining wall system.Four post-tensioned segmental retaining walls(PSRWs)were experimentally tested.Each of the walls was constructed using seven T-s... This paper reports on an experimental study on a new self-centring retaining wall system.Four post-tensioned segmental retaining walls(PSRWs)were experimentally tested.Each of the walls was constructed using seven T-shaped concrete segments with a dry stack.The walls were tested under incrementally increasing cyclic lateral load.The effect of the wall height,levels of post-tensioning(PT)force,and bonded versus unbonded condition of PT reinforcement on the structural behavior of the PSRWs was investigated.The results showed that such PSRWs are structurally adequate for water retaining structures.According to the results,increasing the wall height decreases initial strength but increases the deformation capacity of the wall.The larger deformation capacity and ductility of PSRW make it a suitable structural system for fluctuating loads or deformation,e.g.,seawall.It was also found that increasing the PT force increases the wall’s stiffness;however,reduces its ductility.The residual drift and the extent of damage of the unbonded PSRWs were significantly smaller than those of the bonded ones.Results suggest that this newly developed self-centring retaining wall can be a suitable structural system to retain lateral loads.Due to its unique deformation capacity and self-centring behavior,it can potentially be used for seawall application. 展开更多
关键词 retaining wall SEGMENTAL precast concrete unbonded post-tensioning water retaining wall SEAWALL
原文传递
Effect of earth reinforcement,soil properties and wall properties on bridge MSE walls
17
作者 Zaid MOMANI Eyosias BENEBERU Nur YAZDANI 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2021年第5期1209-1221,共13页
Mechanically stabilized earth(MSE)retaining walls are popular for highway bridge structures.They have precast concrete panels attached to earth reinforcement.The panels are designed to have some lateral movement.Howev... Mechanically stabilized earth(MSE)retaining walls are popular for highway bridge structures.They have precast concrete panels attached to earth reinforcement.The panels are designed to have some lateral movement.However,in some cases,excessive movement and even complete dislocation of the panels have been observed.In this study,3-D numerical modeling involving an existing MSE wall was undertaken to investigate various wall parameters.The effects of pore pressure,soil cohesion,earth reinforcement type and length,breakage/slippage of reinforcement and concrete strength,were examined.Results showed that the wall movement is affected by soil pore pressure and reinforcement integrity and length,and unaffected by concrete strength.Soil cohesion has a minor effect,while the movement increased by 13–20 mm for flexible geogrid reinforced walls compared with the steel grid walls.The steel grid stresses were below yielding,while the geogrid experienced significant stresses without rupture.Geogrid reinforcement may be used taking account of slippage resistance and wall movement.If steel grid is used,non-cohesive soil is recommended to minimize corrosion.Proper soil drainage is important for control of pore pressure. 展开更多
关键词 mechanically stabilized earth walls precast concrete panels backfill soil finite element modeling earth reinforcement
原文传递
上一页 1 下一页 到第