Development of the Press-Through Package Recognizable with Abdominal X-Ray Image of Abdominal Soft Tissue Phantom
1
作者 Kyoichi Ito Morio Shimada +4 位作者 Kiyomi Sadamoto Mikio Murata Kiyoshi Kubota Motoyoshi Itoh Kohki Yoshikawa 《Open Journal of Radiology》 2018年第2期91-98,共8页
Background: Patients with dementia who accidentally swallowed a press- through package (PTP) have been increased in recent years. Swallowed PTP is usually detected with CT having a risk of radiation exposure since PTP... Background: Patients with dementia who accidentally swallowed a press- through package (PTP) have been increased in recent years. Swallowed PTP is usually detected with CT having a risk of radiation exposure since PTP is very difficult to detect with abdominal X-ray image. Purpose: This study is aimed at developing the new PTP sheet recognizable with abdominal X-ray by improving the conventional PTP sheet. Material and Methods: The PTP sheet samples used in this study are: No. 1 Control: Commercially available tablet 100 mg, No. 2 Triple-stacked aluminum foil, 6-overcoated with BaSO4 10.3 g/m2, No. 3 Aluminum foil, 6-overcoated with BaSO4 10.3 g/m2, No. 4 Five-stacked aluminum foil, 6-overcoated with BaSO4 No. 5 Aluminum foil, single-coated with WO3 2.55 g/m2, No. 6 Aluminum foil, double-coated with WO3 5.1 g/m2, No. 7 Aluminum foil, triple-coated with WO3 7.66 g/m2, No. 8 Three-stacked aluminum foil, triple-coated with WO3. PTP sheets (No. 1 - No. 8) were placed inside the abdominal soft tissue phantom, and the images were obtained using FUJIFILM DR CALNEO PT. Region of interest (ROI) was placed on PTP sheets (No. 1 - No. 8) and abdominal soft tissue liquid phantom, and each contrast was measured from the average pixel of the two ROIs. Contrast was calculated by the calculation formula. Each ROI was measured three times, and their average value and standard deviation were estimated. Results: Statistical significance in contrast was not observed in commercial PTP sheet (No. 1), PTP sheet (No. 3), and PTP sheet (No. 5), while there was a significant difference between PTP sheet (No. 1) and PTP sheet (No. 2), PTP sheet (No. 4) PTP sheet (No. 6), PTP sheet (No. 7) (p Conclusion: The other all prototype PTP sheets (No. 2, No. 4, No. 6, No. 7 and No. 8) were well recognized. PTP sheets (No. 2, No. 4) of BaSO4 is considered to be more suitable than PTP sheets of WO3 (No. 6, No. 7, No. 8) because it is easier to produce. We will develop oral PTP sheets for patients with dementia for abdominal X-ray in the future. 展开更多
关键词 press-through package (ptp) Soft Tissue PHANTOM ABDOMINAL X-Ray DEVELOPMENT BASO4 WO3
下载PDF
五轴全伺服三维包装机控制系统设计
2
作者 李鹏 何文雪 +1 位作者 郭福兴 张璐璐 《机械制造与自动化》 2023年第2期201-204,共4页
为提高包装行业中透明膜三维包装的自动化程度和控制精度,采用可编程逻辑控制器设计一种五轴全伺服三维包装机控制系统。该系统以西门子S7-1500PLC为控制核心,交流伺服系统作为驱动单元;S7-1200PLC作为IO设备,通过点到点的自由口通信方... 为提高包装行业中透明膜三维包装的自动化程度和控制精度,采用可编程逻辑控制器设计一种五轴全伺服三维包装机控制系统。该系统以西门子S7-1500PLC为控制核心,交流伺服系统作为驱动单元;S7-1200PLC作为IO设备,通过点到点的自由口通信方式读写温控仪表参数;使用触摸屏对整个系统进行实时监测与控制,实现对多种盒体不同形式的透明膜三维包装功能。实际运行表明:该控制系统极大地提高了生产效率,具有很好的实用价值。 展开更多
关键词 三维包装机 PLC 伺服控制 自由口通信 HMI
下载PDF
LTCC SoP RF Transceiver Module for 60 GHz Wireless Gigabit Ethernet Communication System
3
作者 Azzemi Ariffin Suhandi Bujang +3 位作者 Mohd Fadzil Amiruddin Salizul Jaafarl Noor Aisyah Mohd. Akib Young Chul Lee 《通讯和计算机(中英文版)》 2010年第6期63-70,共8页
关键词 低温共烧陶瓷 射频收发模块 千兆以太网技术 无线通信系统 GHZ 高清晰度电视 无线电频率 无线网络系统