Excavating super-large-span tunnels in soft rock masses presents significant challenges.To ensure safety,the sequential excavation method is commonly adopted.It utilizes internal temporary supports to spatially partit...Excavating super-large-span tunnels in soft rock masses presents significant challenges.To ensure safety,the sequential excavation method is commonly adopted.It utilizes internal temporary supports to spatially partition the tunnel face and divide the excavation into multiple stages.However,these internal supports generally impose spatial constraints,limiting the use of large-scale excavation equipment and reducing construction efficiency.To address this constraint,this study adopts the“Shed-frame”principle to explore the feasibility of an innovative support system,which aims to replace internal supports with prestressed anchor cables and thus provide a more spacious working space with fewer internal obstructions.To evaluate its effectiveness,a field case involving the excavation of a 24-m span tunnel in soft rock is presented,and an analysis of extensive field data is conducted to study the deformation characteristics of the surrounding rock and the mechanical behavior of the support system.The results revealed that prestressed anchor cables integrated the initial support with the shed,creating an effective“shed-frame”system,which successively maintained tunnel deformation and frame stress levels within safe regulatory bounds.Moreover,the prestressed anchor cables bolstered the surrounding rock effectively and reduced the excavation-induced disturbance zone significantly.In summary,the proposed support system balances construction efficiency and safety.These field experiences may offer valuable insights into the popularization and further development of prestressed anchor cable support systems.展开更多
Prestress enables the Glulam beam could make full use of the compression strength,and then increase the span,but it still could not reduce all drawbacks,such as cross-section weakening and small force arm.To avoid slo...Prestress enables the Glulam beam could make full use of the compression strength,and then increase the span,but it still could not reduce all drawbacks,such as cross-section weakening and small force arm.To avoid slotting and ensure suitable tension and compression couple,one kind of novel anchor has been proposed,which could meet the bearing capacity requirement.And then the bending test of prestressed Glulam beams with a geometric scale ratio of 1:2 was simulated,to investigate the effect of the force arm on bending capacities,failure modes,and deformation performance.Results show that increasing the force arm could improve the ultimate bending per-formance of the beam significantly,and the anchor arm length has a certain effect on the performance,but it is not obvious.Finally,based on Finite element method analysis,the practice design suggestions have been offered.展开更多
The anchor stress extent of a prestress anchor cable project has a direct relation with the project safety and performance. Prestressed tensioning method is a kind of nondestructive testing method, by which a reverse ...The anchor stress extent of a prestress anchor cable project has a direct relation with the project safety and performance. Prestressed tensioning method is a kind of nondestructive testing method, by which a reverse stretching load is applied on the external exposure section of anchor cable under construction or in service, and then the elongation variation of stress bars is measured to determine the anchor stress. We elaborated the theory and testing mechanism of prestressed tensioning method, and systematically studied key issues during the prestressed tensioning process of anchor cable by using physical model test, including the composition of tension stress-elongation curve, the variation of anchor stress, the compensation of locked anchor stress, and the judgment of anchor stress, and verified the theory feasibility of prestressed tensioning method. A case study on slope anchor cable of one highway project was conducted to further discuss on the test method, operation procedures and judgment of prestressed tensioning method on obtaining anchor stress, and then the test data of three situations were analyzed. The result provides a theoretical basis and technical base for the application of prestressed tensioning method to the evaluation of construction quality and operation conditions of anchor cable project.展开更多
The present work intends to investigate dynamic behaviour of draft gear using finite element method. The longitudinal force that the draft gear absorbs usually leads to the failure of its components, especially, the l...The present work intends to investigate dynamic behaviour of draft gear using finite element method. The longitudinal force that the draft gear absorbs usually leads to the failure of its components, especially, the load bearing draft pads. Dynamic behaviour of an individual draft pad and a draft gear is determined and characterized with exciting frequen- cies and corresponding mode shapes. The effect of compressive prestress load on the dynamic behaviour of an individual draft pad is also determined as the draft pads in assembled state are under constant axial compressive force in the draft gear. The vibration characteristics of individual draft pad are compared with draft pads that are part of draft gear. The modal analysis gives us a basis for subjecting a draft pad to higher frequency loading for determining its fatigue behaviour.展开更多
An extensive experimental and theoretical research study was undertaken to study the vibration serviceability of a long-span prestressed concrete floor system to be used in the lounge of a major airport.Specifically,j...An extensive experimental and theoretical research study was undertaken to study the vibration serviceability of a long-span prestressed concrete floor system to be used in the lounge of a major airport.Specifically,jumping impact tests were carried out to obtain the floor’s modal parameters,followed by an analysis of the distribution of peak accelerations.Running tests were also performed to capture the acceleration responses.The prestressed concrete floor was found to have a low fundamental natural frequency(≈8.86 Hz)corresponding to the average modal damping ratio of≈2.17%.A coefficients plate with simply-supported edges.The calculated analytical results(natural frequencies and root-mean-square acceleration)agree well with the experimental ones.The analytical approach is thus validated.展开更多
基金supported by the National Natural Science Foundation of China through Grant No.51978523.
文摘Excavating super-large-span tunnels in soft rock masses presents significant challenges.To ensure safety,the sequential excavation method is commonly adopted.It utilizes internal temporary supports to spatially partition the tunnel face and divide the excavation into multiple stages.However,these internal supports generally impose spatial constraints,limiting the use of large-scale excavation equipment and reducing construction efficiency.To address this constraint,this study adopts the“Shed-frame”principle to explore the feasibility of an innovative support system,which aims to replace internal supports with prestressed anchor cables and thus provide a more spacious working space with fewer internal obstructions.To evaluate its effectiveness,a field case involving the excavation of a 24-m span tunnel in soft rock is presented,and an analysis of extensive field data is conducted to study the deformation characteristics of the surrounding rock and the mechanical behavior of the support system.The results revealed that prestressed anchor cables integrated the initial support with the shed,creating an effective“shed-frame”system,which successively maintained tunnel deformation and frame stress levels within safe regulatory bounds.Moreover,the prestressed anchor cables bolstered the surrounding rock effectively and reduced the excavation-induced disturbance zone significantly.In summary,the proposed support system balances construction efficiency and safety.These field experiences may offer valuable insights into the popularization and further development of prestressed anchor cable support systems.
基金supported by the Resources Industry Science and Technology Innovation Joint Funding Project of Nanping(N2021Z003)the Special Project of Service Industry Research of Wuyi University under Grant(2021XJFWCY03)+2 种基金the Research Launch Fund of Wuyi University’s Introduct Talent(YJ202309)the Fujian Training Program of Innovation and Entrepreneurship for Undergraduates(S202210397076)Research on the Stress Performance of Reinforced Bamboo Highway Guardrail with Embedded Channel Steel(LS202304).
文摘Prestress enables the Glulam beam could make full use of the compression strength,and then increase the span,but it still could not reduce all drawbacks,such as cross-section weakening and small force arm.To avoid slotting and ensure suitable tension and compression couple,one kind of novel anchor has been proposed,which could meet the bearing capacity requirement.And then the bending test of prestressed Glulam beams with a geometric scale ratio of 1:2 was simulated,to investigate the effect of the force arm on bending capacities,failure modes,and deformation performance.Results show that increasing the force arm could improve the ultimate bending per-formance of the beam significantly,and the anchor arm length has a certain effect on the performance,but it is not obvious.Finally,based on Finite element method analysis,the practice design suggestions have been offered.
基金Funded by the Science and Technolog Program of Ministry of Transport of P.R.China(No.2012318352100)
文摘The anchor stress extent of a prestress anchor cable project has a direct relation with the project safety and performance. Prestressed tensioning method is a kind of nondestructive testing method, by which a reverse stretching load is applied on the external exposure section of anchor cable under construction or in service, and then the elongation variation of stress bars is measured to determine the anchor stress. We elaborated the theory and testing mechanism of prestressed tensioning method, and systematically studied key issues during the prestressed tensioning process of anchor cable by using physical model test, including the composition of tension stress-elongation curve, the variation of anchor stress, the compensation of locked anchor stress, and the judgment of anchor stress, and verified the theory feasibility of prestressed tensioning method. A case study on slope anchor cable of one highway project was conducted to further discuss on the test method, operation procedures and judgment of prestressed tensioning method on obtaining anchor stress, and then the test data of three situations were analyzed. The result provides a theoretical basis and technical base for the application of prestressed tensioning method to the evaluation of construction quality and operation conditions of anchor cable project.
文摘The present work intends to investigate dynamic behaviour of draft gear using finite element method. The longitudinal force that the draft gear absorbs usually leads to the failure of its components, especially, the load bearing draft pads. Dynamic behaviour of an individual draft pad and a draft gear is determined and characterized with exciting frequen- cies and corresponding mode shapes. The effect of compressive prestress load on the dynamic behaviour of an individual draft pad is also determined as the draft pads in assembled state are under constant axial compressive force in the draft gear. The vibration characteristics of individual draft pad are compared with draft pads that are part of draft gear. The modal analysis gives us a basis for subjecting a draft pad to higher frequency loading for determining its fatigue behaviour.
基金National Natural Science Foundation of China under Grant No.51438001Fundamental Research Funds for the Central Universities under Grant Nos.106112014CDJZR200001 and 106112015CDJXZ208804+1 种基金Chongqing basic and frontier research project under Grant No.cstc2014jcyjys30001National key research and development program of China under Grant No.2016YFC0701201
文摘An extensive experimental and theoretical research study was undertaken to study the vibration serviceability of a long-span prestressed concrete floor system to be used in the lounge of a major airport.Specifically,jumping impact tests were carried out to obtain the floor’s modal parameters,followed by an analysis of the distribution of peak accelerations.Running tests were also performed to capture the acceleration responses.The prestressed concrete floor was found to have a low fundamental natural frequency(≈8.86 Hz)corresponding to the average modal damping ratio of≈2.17%.A coefficients plate with simply-supported edges.The calculated analytical results(natural frequencies and root-mean-square acceleration)agree well with the experimental ones.The analytical approach is thus validated.