This article presents a study on the structural behavior of transversely prestressed laminated timber slabs,focusing on an innovative approach:vertically misaligned lamellae.This misalignment,achieved by sliding verti...This article presents a study on the structural behavior of transversely prestressed laminated timber slabs,focusing on an innovative approach:vertically misaligned lamellae.This misalignment,achieved by sliding vertically the wooden lamellae rather than aligning them,enhances the slab’s cross-section moment of inertia,thereby improving load-bearing capacity and stiffness.Testing involved two groups of structural size specimens:one with vertically aligned lamellae(control group)and the other with misaligned lamellae(study group).Results showed the study group exhibited 42%superior stiffness and 10%less load capacity compared to the control.Failures typically occurred individually in the lamellae,particularly in those with defects or lower modulus of elasticity,concentrated in the middle third of the slabs’free span where tensile stresses peak.Despite a higher number of failed lamellae,the study group demonstrated promising performance.Analysis of prestressing bar indicated no damage at all in the thread,suggesting potential for reducing bar diameter.These findings offer crucial insights into applying these slabs in timber construction as well as to any kind of construction.展开更多
In order to validate the accuracy of nonlinear fire simulation programs,comparison analysis is carried out between simulation and experiment induced from small-scale specimens,and then fire resistance of large-scale p...In order to validate the accuracy of nonlinear fire simulation programs,comparison analysis is carried out between simulation and experiment induced from small-scale specimens,and then fire resistance of large-scale prestressed concrete slabs is further investigated through parameter expansion.The influences on fire resistance ratings controlled by deflection are explored and discussed,including effective span,concrete cover thickness,load level,prestress degree,effective prestress,composite reinforcement index and other factors.The calculated results indicate that fire resistance ratings of large-scale bonded prestressed concrete simply supported slabs are bigger than those of small-scale ones.Finally,the calculation formulas of fire resistance ratings controlled by deflection are established,which rationally consider the influence of effective span,concrete cover thickness,load level,composite reinforcement index and so on key factors.展开更多
Precast prestressed Hollow Core Slabs (HCS), are one of the famous and widely used slabs for concrete structures all over the world and widely implemented in the Middle East. HCS are used in industrial, commercial, re...Precast prestressed Hollow Core Slabs (HCS), are one of the famous and widely used slabs for concrete structures all over the world and widely implemented in the Middle East. HCS are used in industrial, commercial, residential buildings, as well as, in the parking structures. This paper succeeded to present new special details for deep HCS to enhance and strengthen the web shear strength capacity of HCS 400 and 500 mm depths respectively at the open parking area. This is subjected to heavy truck wheel loads so as to achieve the LRFD Code’s requirements. However, it is noticed many web shear cracks of HCS are used at parking area at many projects in Gulf Region. On the other hand, ACI318-14 permits no shear reinforcement in prestressed HCS thickness of less than 12.5 in (320 mm). The paper presents experimental tests program, to verify the numerical finite element of deep HCS under maximum design uniform loads, in addition to the new strengthening techniques. New strengthening techniques succeed to enhance the web shear capacity by significant percentage, due to the new details for HCS 400 by 68% up to 256% increasing of the web shear capacity compared to the ordinary HCS section. Also, HCS 500 shear capacity is enhanced with different percentages of strengthening techniques by 55%, up to 197% based on the different cases of strengthening. Furthermore enhancing deep HCS shear performance;the new techniques have an advantage of an easy execution at the site;casting with structural topping, otherwise the preparation can be done in precast factory before site handover, which saves time and cost compared to the others traditional strengthening techniques.展开更多
As the influence of the ratio of the characteristic value of structural resistance to that of frequent combination effect, K, on the thickness of concrete cover of prestressed concrete (PC) beams and slabs for fire ...As the influence of the ratio of the characteristic value of structural resistance to that of frequent combination effect, K, on the thickness of concrete cover of prestressed concrete (PC) beams and slabs for fire resistance is not considered sufficiently in design criteria for concrete structures in China and other countries at present, numerical analyses were carried out by ANSYS software on unbonded prestressed concrete (UPC) oneway simply-supported and continuous slabs and beams, and bonded PC simply-supported and continuous beams subjected to fire in 186 cases. In the analysis, K, section dimensions and the thickness of concrete cover are regarded as independent variables and some calculation parameters determined by trial and error based on test resuits. Calculation formula for fire endurance of UPC simply-supported and continuous slabs was proposed, and the recommended thicknesses of cover of PC beams and slabs was presented in consideration of the influence of K and section dimensions as well as fire endurance requirements. Comparison analysis of relevant design criterions in China and other countries was performed to verify the rationale of the proposed values.展开更多
文摘This article presents a study on the structural behavior of transversely prestressed laminated timber slabs,focusing on an innovative approach:vertically misaligned lamellae.This misalignment,achieved by sliding vertically the wooden lamellae rather than aligning them,enhances the slab’s cross-section moment of inertia,thereby improving load-bearing capacity and stiffness.Testing involved two groups of structural size specimens:one with vertically aligned lamellae(control group)and the other with misaligned lamellae(study group).Results showed the study group exhibited 42%superior stiffness and 10%less load capacity compared to the control.Failures typically occurred individually in the lamellae,particularly in those with defects or lower modulus of elasticity,concentrated in the middle third of the slabs’free span where tensile stresses peak.Despite a higher number of failed lamellae,the study group demonstrated promising performance.Analysis of prestressing bar indicated no damage at all in the thread,suggesting potential for reducing bar diameter.These findings offer crucial insights into applying these slabs in timber construction as well as to any kind of construction.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50678050)
文摘In order to validate the accuracy of nonlinear fire simulation programs,comparison analysis is carried out between simulation and experiment induced from small-scale specimens,and then fire resistance of large-scale prestressed concrete slabs is further investigated through parameter expansion.The influences on fire resistance ratings controlled by deflection are explored and discussed,including effective span,concrete cover thickness,load level,prestress degree,effective prestress,composite reinforcement index and other factors.The calculated results indicate that fire resistance ratings of large-scale bonded prestressed concrete simply supported slabs are bigger than those of small-scale ones.Finally,the calculation formulas of fire resistance ratings controlled by deflection are established,which rationally consider the influence of effective span,concrete cover thickness,load level,composite reinforcement index and so on key factors.
文摘Precast prestressed Hollow Core Slabs (HCS), are one of the famous and widely used slabs for concrete structures all over the world and widely implemented in the Middle East. HCS are used in industrial, commercial, residential buildings, as well as, in the parking structures. This paper succeeded to present new special details for deep HCS to enhance and strengthen the web shear strength capacity of HCS 400 and 500 mm depths respectively at the open parking area. This is subjected to heavy truck wheel loads so as to achieve the LRFD Code’s requirements. However, it is noticed many web shear cracks of HCS are used at parking area at many projects in Gulf Region. On the other hand, ACI318-14 permits no shear reinforcement in prestressed HCS thickness of less than 12.5 in (320 mm). The paper presents experimental tests program, to verify the numerical finite element of deep HCS under maximum design uniform loads, in addition to the new strengthening techniques. New strengthening techniques succeed to enhance the web shear capacity by significant percentage, due to the new details for HCS 400 by 68% up to 256% increasing of the web shear capacity compared to the ordinary HCS section. Also, HCS 500 shear capacity is enhanced with different percentages of strengthening techniques by 55%, up to 197% based on the different cases of strengthening. Furthermore enhancing deep HCS shear performance;the new techniques have an advantage of an easy execution at the site;casting with structural topping, otherwise the preparation can be done in precast factory before site handover, which saves time and cost compared to the others traditional strengthening techniques.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50678050)the Outstanding Youth Science Foundation of Heilongjiang Province(Grant No.2001-8)
文摘As the influence of the ratio of the characteristic value of structural resistance to that of frequent combination effect, K, on the thickness of concrete cover of prestressed concrete (PC) beams and slabs for fire resistance is not considered sufficiently in design criteria for concrete structures in China and other countries at present, numerical analyses were carried out by ANSYS software on unbonded prestressed concrete (UPC) oneway simply-supported and continuous slabs and beams, and bonded PC simply-supported and continuous beams subjected to fire in 186 cases. In the analysis, K, section dimensions and the thickness of concrete cover are regarded as independent variables and some calculation parameters determined by trial and error based on test resuits. Calculation formula for fire endurance of UPC simply-supported and continuous slabs was proposed, and the recommended thicknesses of cover of PC beams and slabs was presented in consideration of the influence of K and section dimensions as well as fire endurance requirements. Comparison analysis of relevant design criterions in China and other countries was performed to verify the rationale of the proposed values.