A measurement of the ^235U prompt fission neutron spectrum (PFNS) by the recoil proton method was performed at the Institute of Nuclear Physics and Chemistry, China. Details of the method, which include the calculatio...A measurement of the ^235U prompt fission neutron spectrum (PFNS) by the recoil proton method was performed at the Institute of Nuclear Physics and Chemistry, China. Details of the method, which include the calculation and validation of the response matrix, are presented. The PFNS for ^235U in the energy range 1–12 MeV, induced by thermal neutrons, was obtained. The measured spectrum in the low-energy region was in good agreement with previous work and the ENDF/B-VII library, except for minor differences. In the high-energy region, however, the relative height of the measured spectrum was greater, and an analysis of the experiment indicated uncertainties of 13% at 10 MeV and 24% at 12 MeV. Experimental results showed that the recoil proton method could be used to measure prompt fission neutron spectra. Some directions for future work are included.展开更多
The exact calculation of point kinetic parameters is very important in nuclear reactor safety assessment, and most sophisticated safety codes such as RELAP5, PARCS,DYN3D, and PARET are using these parameters in their ...The exact calculation of point kinetic parameters is very important in nuclear reactor safety assessment, and most sophisticated safety codes such as RELAP5, PARCS,DYN3D, and PARET are using these parameters in their dynamic models. These parameters include effective delayed neutron fractions as well as mean generation time.These parameters are adjoint-weighted, and adjoint flux is employed as a weighting function in their evaluation.Adjoint flux calculation is an easy task for most of deterministic codes, but its evaluation is cumbersome for Monte Carlo codes. However, in recent years, some sophisticated techniques have been proposed for Monte Carlo-based point kinetic parameters calculation without any need of adjoint flux. The most straightforward scheme is known as the ‘‘prompt method'' and has been used widely in literature. The main objective of this article is dedicated to point kinetic parameters calculation in Tehran research reactor(TRR) using deterministic as well as probabilistic techniques. WIMS-D5B and CITATION codes have been used in deterministic calculation of forward and adjoint fluxes in the TRR core. On the other hand, the MCNP Monte Carlo code has been employed in the ‘‘prompt method''scheme for effective delayed neutron fraction evaluation.Deterministic results have been cross-checked with probabilistic ones and validated with SAR and experimental data. In comparison with experimental results, the relativedifferences of deterministic as well as probabilistic methods are 7.6 and 3.2%, respectively. These quantities are10.7 and 6.4%, respectively, in comparison with SAR report.展开更多
Prompt gamma neutron activation analysis (PGNAA) is a non-destructive online measurement nuclear analysis method. With its unique advantages, it has been widely used in online analysis of industrial materials such as ...Prompt gamma neutron activation analysis (PGNAA) is a non-destructive online measurement nuclear analysis method. With its unique advantages, it has been widely used in online analysis of industrial materials such as coal, cement, and minerals in recent years. </span><span style="font-family:Verdana;">However, there are many kinds of literature on PGNAA in the field of industrial materials detection, and there are still a few concluding articles. To this end,</span><span style="font-family:Verdana;"> based on the principle of PGNAA online analysis, the status quo and development of the real-time online detection of industrial material components in the field are reviewed and discussed by consulting a large number of domestic and foreign PGNAA related literature and data, to facilitate the reference of relevant scientific researchers.展开更多
基金supported by the National Natural Science Foundation of China(No.11775196)the Chinese Special Project for ITER(No.2015GB108006)
文摘A measurement of the ^235U prompt fission neutron spectrum (PFNS) by the recoil proton method was performed at the Institute of Nuclear Physics and Chemistry, China. Details of the method, which include the calculation and validation of the response matrix, are presented. The PFNS for ^235U in the energy range 1–12 MeV, induced by thermal neutrons, was obtained. The measured spectrum in the low-energy region was in good agreement with previous work and the ENDF/B-VII library, except for minor differences. In the high-energy region, however, the relative height of the measured spectrum was greater, and an analysis of the experiment indicated uncertainties of 13% at 10 MeV and 24% at 12 MeV. Experimental results showed that the recoil proton method could be used to measure prompt fission neutron spectra. Some directions for future work are included.
文摘The exact calculation of point kinetic parameters is very important in nuclear reactor safety assessment, and most sophisticated safety codes such as RELAP5, PARCS,DYN3D, and PARET are using these parameters in their dynamic models. These parameters include effective delayed neutron fractions as well as mean generation time.These parameters are adjoint-weighted, and adjoint flux is employed as a weighting function in their evaluation.Adjoint flux calculation is an easy task for most of deterministic codes, but its evaluation is cumbersome for Monte Carlo codes. However, in recent years, some sophisticated techniques have been proposed for Monte Carlo-based point kinetic parameters calculation without any need of adjoint flux. The most straightforward scheme is known as the ‘‘prompt method'' and has been used widely in literature. The main objective of this article is dedicated to point kinetic parameters calculation in Tehran research reactor(TRR) using deterministic as well as probabilistic techniques. WIMS-D5B and CITATION codes have been used in deterministic calculation of forward and adjoint fluxes in the TRR core. On the other hand, the MCNP Monte Carlo code has been employed in the ‘‘prompt method''scheme for effective delayed neutron fraction evaluation.Deterministic results have been cross-checked with probabilistic ones and validated with SAR and experimental data. In comparison with experimental results, the relativedifferences of deterministic as well as probabilistic methods are 7.6 and 3.2%, respectively. These quantities are10.7 and 6.4%, respectively, in comparison with SAR report.
文摘Prompt gamma neutron activation analysis (PGNAA) is a non-destructive online measurement nuclear analysis method. With its unique advantages, it has been widely used in online analysis of industrial materials such as coal, cement, and minerals in recent years. </span><span style="font-family:Verdana;">However, there are many kinds of literature on PGNAA in the field of industrial materials detection, and there are still a few concluding articles. To this end,</span><span style="font-family:Verdana;"> based on the principle of PGNAA online analysis, the status quo and development of the real-time online detection of industrial material components in the field are reviewed and discussed by consulting a large number of domestic and foreign PGNAA related literature and data, to facilitate the reference of relevant scientific researchers.