Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this...Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains.展开更多
Foundling islands are also called baby safety islands. Overseas they are also called foundling protection cabins and are a place to care for abandoned babies. In June 2011, the Shijiazhuang Social Welfare Institute in...Foundling islands are also called baby safety islands. Overseas they are also called foundling protection cabins and are a place to care for abandoned babies. In June 2011, the Shijiazhuang Social Welfare Institute in Hebei Province set up a foundling island. By the end of 2013, many cities had set up such islands, which is a new measure for ensuring children rights.展开更多
The setting values of thresholds for fault feature parameters are critical in all kinds of protection schemes.When the detected feature parameter value exceeds the setting value,the protection will trip.However,the se...The setting values of thresholds for fault feature parameters are critical in all kinds of protection schemes.When the detected feature parameter value exceeds the setting value,the protection will trip.However,the setting value based conventional protection schemes sometimes cannot satisfy the protection requirements of neutral ineffectively earthed power systems(NIEPS)due to wide variations in operating conditions and the complexities of fault cases.In this paper,a novel single phase grounding fault protection scheme without threshold setting is proposed.The fault detection is achieved based on operating states rather than setting values.A fuzzy c-means algorithm is used to divide the operating state of the protected feeder into non-fault states and fault states.The cluster center of each state is then obtained by classifying the historical feature samples of the protected feeder extracted under various operating conditions into their corresponding states in a constructed multi-dimensional fault feature space.The distances between the detected feature samples and the cluster centers of the non-fault and the fault states are calculated.If the distance to the fault state is shorter than that to the non-fault state,a fault is detected.Otherwise,the feeder is considered normal.A PSCAD/EMTDC simulator is used to simulate a 35 kV NIEPS under various operating conditions,non-linear loads,and complex fault cases.Results show that the proposed single phase grounding fault protection scheme without threshold setting can protect the system correctly under all kinds of faults.展开更多
文摘Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains.
文摘Foundling islands are also called baby safety islands. Overseas they are also called foundling protection cabins and are a place to care for abandoned babies. In June 2011, the Shijiazhuang Social Welfare Institute in Hebei Province set up a foundling island. By the end of 2013, many cities had set up such islands, which is a new measure for ensuring children rights.
基金supported in part by National Natural Science Foundation of China under Grant 61233008 and Grant 51277014.
文摘The setting values of thresholds for fault feature parameters are critical in all kinds of protection schemes.When the detected feature parameter value exceeds the setting value,the protection will trip.However,the setting value based conventional protection schemes sometimes cannot satisfy the protection requirements of neutral ineffectively earthed power systems(NIEPS)due to wide variations in operating conditions and the complexities of fault cases.In this paper,a novel single phase grounding fault protection scheme without threshold setting is proposed.The fault detection is achieved based on operating states rather than setting values.A fuzzy c-means algorithm is used to divide the operating state of the protected feeder into non-fault states and fault states.The cluster center of each state is then obtained by classifying the historical feature samples of the protected feeder extracted under various operating conditions into their corresponding states in a constructed multi-dimensional fault feature space.The distances between the detected feature samples and the cluster centers of the non-fault and the fault states are calculated.If the distance to the fault state is shorter than that to the non-fault state,a fault is detected.Otherwise,the feeder is considered normal.A PSCAD/EMTDC simulator is used to simulate a 35 kV NIEPS under various operating conditions,non-linear loads,and complex fault cases.Results show that the proposed single phase grounding fault protection scheme without threshold setting can protect the system correctly under all kinds of faults.