期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Assessment of the Protective Capacity of Vadoze Zone over Aquifer Systems Using Secondary Geoelectrical Parameters: A Case Study of Kaltungo Area North East, Nigeria
1
作者 E.Y.Mbiimbe I.B.Goni +1 位作者 J.M.El-Nafaty A.U.Yuguda 《Journal of Environmental & Earth Sciences》 2020年第2期1-11,共11页
An assessment of the protective capacity of the vadose zone overlyingthe aquifer systems in the Kaltungo area was carried out to determine itsinfluence on groundwater quality. Applying the schlumberger array with amax... An assessment of the protective capacity of the vadose zone overlyingthe aquifer systems in the Kaltungo area was carried out to determine itsinfluence on groundwater quality. Applying the schlumberger array with amaximum electrode spread AB/2 = 100m through VES, thirty water wellpoints were surveyed using Omega terrameter (PIOSO1) resistivity meter.The field data was first subjected to manual interpretation through curvemarching and then digitized modeled curves using computer software. Theinterpreted data revealed that the area is characterized by eleven differentcurve types representing three to five geo electrical layers. In order toassess the protective capacity of the vadoze zone over the aquifer systems,the longitudinal conductance (S) and transverse resistance (T) (secondarygeoelectric parameters) were computed from the primary data using theDar Zarouk formula. The values of S obtained range from 0.0018 to 0.4056ohms with a mean value of 0.0135 ohms while the values of T range from0.55 ohms to 1195.68 ohms with a mean value of 39.84 ohms. The valuesof S and T obtained reveal that 90% of probed points has poor protectivecapacity, 10 % has moderate protective capacity and 83 % has hightransmissivity, 17 % has intermediate transmissivity. The T and S values areskewed towards poorly protective capacity thus making groundwater in thearea highly vulnerable to contamination from the surface. To achieve goodgroundwater quality in the area, proper completion of newly constructedwells should install protective casing through the entire vadose zone. 展开更多
关键词 ASSESSMENT Protective capacity Vadose zone Aquifer systems Secondary Geoelectric Parameters and Kaltungo Area
下载PDF
Evaluation of aquifer hydraulic properties from resistivity and pumping test data in parts of Gwagwalada,Northcentral Nigeria
2
作者 ILUNGA Nyembwe AMADI Akobundu Nwanosike +2 位作者 Gilbert NDATIMANA Nelson OKOT Raphal TSHIMANGA Muamba 《Journal of Groundwater Science and Engineering》 2024年第3期309-320,共12页
Population upsurge in Gwagwalada increased water demand in the area,thereby stressing water resources in the area.Aquifer properties in parts of Gwagwalada in North-Central Nigeria were therefore investigated using re... Population upsurge in Gwagwalada increased water demand in the area,thereby stressing water resources in the area.Aquifer properties in parts of Gwagwalada in North-Central Nigeria were therefore investigated using resistivity and hydrogeological approaches.Static water level measurements of hand dug wells were used to determine the groundwater flow direction for the area which coincides with the North East-South West joint direction.Constant rate pumping test was adopted for the research and 10 boreholes were pumped.The weathered/fractured basement range from 7.5 m to 56.7 m.The transmissivity values in the area ranged from 0.35 m^(2)/d to 3.63 m^(2)/d while the hydraulic conductivity range from 0.045 m/d to 0.18 m/d.The Vertical Electrical Soundings(VES)were carried out on the area.The geoelectric sections revealed four to five layers and the longitudinal conductance varied from 0.11Ω^(-1)to 0.37Ω^(-1).The results of the investigation characterized the groundwater potential in the study area into low and moderate while the aquifer protective capacity into weak and moderate zones.The efficacy of resistivity and pumping test data in quantifying aquifer properties has been established in this study.The findings of this study shed light on the properties of ground water and aquifer protective capacity in the area,hence assist in the effective future groundwater resources exploitation. 展开更多
关键词 TRANSMISSIVITY VES Dar Zarrouk Parameters Groundwater Potential Aquifer Protective capacity
下载PDF
Integrated Geophysical and Hydrogeochemical Characterization and Assessment of Groundwater Studies in Adum West Area of Benue State,Nigeria 被引量:2
3
作者 Moses Oghenenyoreme Eyankware Christopher Ogwah Umayah Otitie Star 《Journal of Geological Research》 2021年第3期14-27,共14页
Integration of geophysical and hydrogeochemical methods has been scientifically proven to be useful in vulnerability study and groundwater characterization.Subsurface geoelectric parameters such as resistivity and thi... Integration of geophysical and hydrogeochemical methods has been scientifically proven to be useful in vulnerability study and groundwater characterization.Subsurface geoelectric parameters such as resistivity and thickness obtained from geophysical method(Vertical Electrical Sounding VES)was used to determine aquifers vulnerability,longitudinal resistance(ρL)and transverse unit resistance(Rt).Thirty four water samples were collected from groundwater sources for physicochemical analysis.Estimated results from longitudinal conductance(S),(Rt)and(ρL)showed that the values ranges from 0.03 to 2.5mhos,103.64 to 1964417.8Ω/m^(2) and 215.41 to 65731.68Ω-m respectively.Result from S suggested that 50%of groundwater is considered to be vulnerable to contamination from the earth surface,while the remaining 50%is considered to be slightly vulnerable to surface contamination.Further findings obtained from hydrogeochemical analysis such as Gibb’s and Chadba plots revealed that groundwater is highly influenced by rock water interaction,groundwater is classified to be Na^(+)+HCO_(3)^(-),Ca^(2+)+Mg^(2+)+HCO_(3)^(-),Na^(+)+Cl^(-)and Ca^(2+)+Mg^(2+)+Cl^(-)water type.Deduction from Soltan classification suggested that groundwater is classified to be of Na^(+)+HCO_(3)^(-) and Na^(+)-SO_(4)^(2-) water type.Results obtained from Ec and pH suggested that the values were below WHO permissible limit,while result obtained from TDS showed that at some sampling points TDS values were above WHO limit.Based on pH value obtained groundwater within the study area fell within slightly basic to acidic. 展开更多
关键词 GROUNDWATER RESISTIVITY Contamination Aquifer protective capacity NIGERIA
下载PDF
The Change of Ecological Footprint and Its Effect on Sustainable Development in Beijing of China
4
作者 Ying Zhang 《Chinese Business Review》 2005年第10期1-12,20,共13页
Speeding up the environmental protection and construction is one of the major issues in "Greener Olympic Games" held in Beijing in 2008. Making a thorough study to find out the reliable measures to ecological resump... Speeding up the environmental protection and construction is one of the major issues in "Greener Olympic Games" held in Beijing in 2008. Making a thorough study to find out the reliable measures to ecological resumption in Beijing has an important scientific and practical significance. It can provide scientific basis for making a better decision for "Greener Olympic Games" held in capital Beijing and development in harmony for society and economy, as well as management for ecological environment. By studying of change of ecological footprint from 1990 to 2003 in Beijing, the paper shows that ecological footprint per capita has a strong relativity with population and GDP, and both of the correlation coefficient between them is about 0.92, as well as the fossil energy land has a position in the lead in ecological footprint items. The study also shows that the ecological capacity per capita in Beijing occupied about 1.25% in global ecological capacity per capita. Began 1990, the ecological deficit in Beijing was about 0.72 hm2, which is at strong unsustainable development at present. Finally, the paper suggests social and economic structure should be adjusted as soon as possible, resources should be strengthen sustainable used and population increasing should be controlled strictly, as well as arable land also should be under control used for built-up areas. Simultaneity, the utilizing ratio of energy sources should be increased, and the consumption of energy sources and ecological deficit in Beijing should be reduced in order to speed up the society and economy development in harmony and sustainment. 展开更多
关键词 Beijing ecological footprint ecological capacity environment protection sustainable development
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部