To enhance the accuracy of 2πα and 2πβ particle surface emission rate measurements and address the identification issues of nuclides in conventional methods, this study introduces two artificial neural network(ANN...To enhance the accuracy of 2πα and 2πβ particle surface emission rate measurements and address the identification issues of nuclides in conventional methods, this study introduces two artificial neural network(ANN) algorithms: back-propagation(BP) and genetic algorithm-based back-propagation(GA-BP). These algorithms classify pulse signals from distinct α and β particles. Their discrimination efficacy is assessed by simulating standard pulse signals and those produced by contaminated sources, mixing α and β particles within the detector. This study initially showcases energy spectrum measurement outcomes, subsequently tests the ANNs on the measurement and validation datasets, and contrasts the pulse shape discrimination efficacy of both algorithms. Experimental findings reveal that the proportional counter's energy resolution is not ideal, thus rendering energy analysis insufficient for distinguishing between 2πα and 2πβ particles. The BP neural network realizes approximately 99% accuracy for 2πα particles and approximately 95% for 2πβ particles, thus surpassing the GA-BP's performance. Additionally, the results suggest enhancing β particle discrimination accuracy by increasing the digital acquisition card's threshold lower limit. This study offers an advanced solution for the 2πα and 2πβ surface emission rate measurement method, presenting superior adaptability and scalability over conventional techniques.展开更多
In this study,the anti-noise performance of a pulse-coupled neural network(PCNN)was investigated in the neutron and gamma-ray(n-γ)discrimination field.The experiments were conducted in two groups.In the first group,r...In this study,the anti-noise performance of a pulse-coupled neural network(PCNN)was investigated in the neutron and gamma-ray(n-γ)discrimination field.The experiments were conducted in two groups.In the first group,radiation pulse signals were pre-processed using a Fourier filter to reduce the original noise in the signals,whereas in the second group,the original noise was left untouched to simulate an extremely high-noise scenario.For each part,artificial Gaussian noise with different intensity levels was added to the signals prior to the discrimination process.In the aforementioned conditions,the performance of the PCNN was evaluated and compared with five other commonly used methods of n-γdiscrimination:(1)zero crossing,(2)charge comparison,(3)vector projection,(4)falling edge percentage slope,and(5)frequency gradient analysis.The experimental results showed that the PCNN method significantly outperforms other methods with outstanding FoM-value at all noise levels.Furthermore,the fluctuations in FoM-value of PCNN were significantly better than those obtained via other methods at most noise levels and only slightly worse than those obtained via the charge comparison and zerocrossing methods under extreme noise conditions.Additionally,the changing patterns and fluctuations of the FoMvalue were evaluated under different noise conditions.Hence,based on the results,the parameter selection strategy of the PCNN was presented.In conclusion,the PCNN method is suitable for use in high-noise application scenarios for n-γdiscrimination because of its stability and remarkable discrimination performance.It does not rely on strict parameter settings and can realize satisfactory performance over a wide parameter range.展开更多
To reduce the experimental uncertainty in the 235 U resonance energy region and improve the detection efficiency for neutron total cross section measurements compared with those obtained with the neutron total cross s...To reduce the experimental uncertainty in the 235 U resonance energy region and improve the detection efficiency for neutron total cross section measurements compared with those obtained with the neutron total cross section spectrometer(NTOX), a dedicated lithium-containing scintillation detector has been developed on the Back-n beam line at the China Spallation Neutron Source. The Fast Scintillator-based Neutron Total Cross Section(FAST) spectrometer has been designed based on a Cs2Li La Br6(CLLB) scintillator considering the γ-ray flash and neutron environment on the Back-n beam line. The response of the CLLB scintillator to neutrons and γ-rays was evaluated with different 6Li/7 Li abundance ratios using Geant4. The neutron-γdiscrimination performance of the CLLB has been simulated considering different scintillation parameters, physical designs,and light readout modes. A cubic 6Li-enriched( > 90%) CLLB scintillator, which has a thickness of 4-9 mm and side length of no less than 50 mm to cover the Φ 50 mm neutron beam at the spectrometer position, has been proposed coupling to a side readout SiPM array to construct the FAST spectrometer. The developed simulation techniques for neutron-γ discrimination performance could provide technical support for other neutron-induced reaction measurements on the Back-n beam line.展开更多
Linear Alkyl Benzene (LAB) is a promising liquid scintillator solvent in neutrino experiments because it has many appealing properties. The timing properties of LAB-based liquid scintillator have been studied throug...Linear Alkyl Benzene (LAB) is a promising liquid scintillator solvent in neutrino experiments because it has many appealing properties. The timing properties of LAB-based liquid scintillator have been studied through ultraviolet and ionization excitation in this study. The decay time of LAB, PPO and bis-MSB is found to be 48.6 ns, 1.55 ns and 1.5 ns, respectively. A model can describe the absorption and re-emission process between PPO and bis-MSB perfectly. The energy transfer time between LAB and PPO with different concentrations can be obtained via another model. We also show that the LAB-based liquid scintillator has good (n, γ) and (α, γ) discrimination power.展开更多
The output amplitude of the differential circuit is studied for differential discrimination in pulsed laser time-offlight systems. Based on the studies of the probability of detection and the probability of false alar...The output amplitude of the differential circuit is studied for differential discrimination in pulsed laser time-offlight systems. Based on the studies of the probability of detection and the probability of false alarms, the minimum detectable input signal of differential discrimination can be calculated. The results indicate that the differential discrimination detectability of the small signal will be reduced. A combined discrimination is proposed in this Letter to improve the time resolution of the large signal and ensure the probability of detection of the small signal at the same time. A proper value of the circuit parameter is found to balance the time resolutions of the small and large signals.展开更多
Purpose Among the several methods to measure ^(222)Rn in water,the liquid scintillation counting(LSC)technique is one of the most sensitive and widely used when analysing non-saline waters by liquid extraction,providi...Purpose Among the several methods to measure ^(222)Rn in water,the liquid scintillation counting(LSC)technique is one of the most sensitive and widely used when analysing non-saline waters by liquid extraction,providing excellent accuracy,precision and low-level detection limits.When using the liquid scintillation counter Tri-Carb 3170 TR/SL(Perkin-Elmer)it is not possible to make an automatic determination of the alpha/beta discrimination parameter,being necessary to evaluate the pulse decay discriminator(PDD)value manually to the ^(222)Rn determination.In this work,we describe the steps to perform the calibration of that type of equipment.Methods The method consists in the preparation of standard samples from a ^(226)Ra certified standard solution and the adjustment of the PDD value by hand until the percentage of alpha events reaches a plateau of a near-constant fraction of total events.The process consists in taking several measures between PDD 80 and 200 with 15 min counting time each.Within the plateau,the alpha/beta ratio was used to determine the plateau final range as well as the optimum PDD value.After that,the calibration standards and blanks were measured and the region of interest(ROI)was established by finding the maximum value for the figure of merit(FOM)in the upper and lower limits.Results The optimal PDD value of 148 was established by the alpha/beta ratio,and after that,it was possible to measure ^(226)Ra standards to perform the calibration.An efficiency of(9.758±0.035)×1^(0-1) was obtained.In routine measurements,a detection limit of about 0.50 Bq L^(-1) is achieved for a 120 min counting time.To evaluate the uncertainty budget,the uncertainties of the net count rate,the efficiency,the sample amount and the decay correction factor were considered.Conclusions A method was developed for the calibration of LSC Tri-Carb 3170 TR/SL with the optimization of the PDD using a ^(226)Ra standard solution.The acquisition to obtain the plot of the variation of the events fraction in each window(alpha and beta)in function of PDD allowed to evaluate a plateau where the fraction of events was at a minimum.Afterwards,it was possible to measure the set of ^(226)Ra standards after the equilibrium with ^(222)Rn and determine the efficiency for ^(222)Rn with a detection limit of about 0.50 Bq L^(-1) in routine analyses.展开更多
Purpose Radon is a noble gas,which endangers our health.The liquid scintillator is one of the detector materials used to measure radon in the environment.But there are challenges in measuring radon using a liquid scin...Purpose Radon is a noble gas,which endangers our health.The liquid scintillator is one of the detector materials used to measure radon in the environment.But there are challenges in measuring radon using a liquid scintillator,such as independent manual operation and long measurement periods.Methods and Results We propose a liquid scintillator detector for the rapid measurement of radon,which is composed of a breathable liquid scintillator probe and photomultiplier tube.Cascade decay recognition and pulse shape discrimination(PSD)were used to select radon events.241 Am4(α)and 90Sr(β)source calibration was used to optimize the PSDfigure of merit of the liquid scintillator,and a 232Th(220Rn)diffusion source was used to verify the function of this novel detector for measuring radon.Conclusion The detector had an integrated design for sampling and measurement,which simplified the measurement steps.Thus,this novel liquid scintillator detector demonstrated promise for use in radon-detection systems.展开更多
文摘To enhance the accuracy of 2πα and 2πβ particle surface emission rate measurements and address the identification issues of nuclides in conventional methods, this study introduces two artificial neural network(ANN) algorithms: back-propagation(BP) and genetic algorithm-based back-propagation(GA-BP). These algorithms classify pulse signals from distinct α and β particles. Their discrimination efficacy is assessed by simulating standard pulse signals and those produced by contaminated sources, mixing α and β particles within the detector. This study initially showcases energy spectrum measurement outcomes, subsequently tests the ANNs on the measurement and validation datasets, and contrasts the pulse shape discrimination efficacy of both algorithms. Experimental findings reveal that the proportional counter's energy resolution is not ideal, thus rendering energy analysis insufficient for distinguishing between 2πα and 2πβ particles. The BP neural network realizes approximately 99% accuracy for 2πα particles and approximately 95% for 2πβ particles, thus surpassing the GA-BP's performance. Additionally, the results suggest enhancing β particle discrimination accuracy by increasing the digital acquisition card's threshold lower limit. This study offers an advanced solution for the 2πα and 2πβ surface emission rate measurement method, presenting superior adaptability and scalability over conventional techniques.
基金supported by the National Natural Science Foundation of China(Nos.4210040255,U19A2086)the Sichuan Science and Technology Program(No.2021JDRC0108)。
文摘In this study,the anti-noise performance of a pulse-coupled neural network(PCNN)was investigated in the neutron and gamma-ray(n-γ)discrimination field.The experiments were conducted in two groups.In the first group,radiation pulse signals were pre-processed using a Fourier filter to reduce the original noise in the signals,whereas in the second group,the original noise was left untouched to simulate an extremely high-noise scenario.For each part,artificial Gaussian noise with different intensity levels was added to the signals prior to the discrimination process.In the aforementioned conditions,the performance of the PCNN was evaluated and compared with five other commonly used methods of n-γdiscrimination:(1)zero crossing,(2)charge comparison,(3)vector projection,(4)falling edge percentage slope,and(5)frequency gradient analysis.The experimental results showed that the PCNN method significantly outperforms other methods with outstanding FoM-value at all noise levels.Furthermore,the fluctuations in FoM-value of PCNN were significantly better than those obtained via other methods at most noise levels and only slightly worse than those obtained via the charge comparison and zerocrossing methods under extreme noise conditions.Additionally,the changing patterns and fluctuations of the FoMvalue were evaluated under different noise conditions.Hence,based on the results,the parameter selection strategy of the PCNN was presented.In conclusion,the PCNN method is suitable for use in high-noise application scenarios for n-γdiscrimination because of its stability and remarkable discrimination performance.It does not rely on strict parameter settings and can realize satisfactory performance over a wide parameter range.
基金supported by the Key Laboratory of Nuclear Data Foundation(No.JCKY2022201C153)National Natural Science Foundation of China(No.11505216),Educational Commission of Hunan Province of China(No.19B488)Natural Science Foundation of Hunan Province of China(Nos.2021JJ40444 and 2020RC3054).
文摘To reduce the experimental uncertainty in the 235 U resonance energy region and improve the detection efficiency for neutron total cross section measurements compared with those obtained with the neutron total cross section spectrometer(NTOX), a dedicated lithium-containing scintillation detector has been developed on the Back-n beam line at the China Spallation Neutron Source. The Fast Scintillator-based Neutron Total Cross Section(FAST) spectrometer has been designed based on a Cs2Li La Br6(CLLB) scintillator considering the γ-ray flash and neutron environment on the Back-n beam line. The response of the CLLB scintillator to neutrons and γ-rays was evaluated with different 6Li/7 Li abundance ratios using Geant4. The neutron-γdiscrimination performance of the CLLB has been simulated considering different scintillation parameters, physical designs,and light readout modes. A cubic 6Li-enriched( > 90%) CLLB scintillator, which has a thickness of 4-9 mm and side length of no less than 50 mm to cover the Φ 50 mm neutron beam at the spectrometer position, has been proposed coupling to a side readout SiPM array to construct the FAST spectrometer. The developed simulation techniques for neutron-γ discrimination performance could provide technical support for other neutron-induced reaction measurements on the Back-n beam line.
基金Supported by National Natural Science Foundation of China (10890094, 11011120080)
文摘Linear Alkyl Benzene (LAB) is a promising liquid scintillator solvent in neutrino experiments because it has many appealing properties. The timing properties of LAB-based liquid scintillator have been studied through ultraviolet and ionization excitation in this study. The decay time of LAB, PPO and bis-MSB is found to be 48.6 ns, 1.55 ns and 1.5 ns, respectively. A model can describe the absorption and re-emission process between PPO and bis-MSB perfectly. The energy transfer time between LAB and PPO with different concentrations can be obtained via another model. We also show that the LAB-based liquid scintillator has good (n, γ) and (α, γ) discrimination power.
文摘The output amplitude of the differential circuit is studied for differential discrimination in pulsed laser time-offlight systems. Based on the studies of the probability of detection and the probability of false alarms, the minimum detectable input signal of differential discrimination can be calculated. The results indicate that the differential discrimination detectability of the small signal will be reduced. A combined discrimination is proposed in this Letter to improve the time resolution of the large signal and ensure the probability of detection of the small signal at the same time. A proper value of the circuit parameter is found to balance the time resolutions of the small and large signals.
基金the Fundacao para a Ciencia e Tecnologia(FCT)support through the UID/Multi/04349/2013 projectfunding provided by FCTIFCCN(b-on).
文摘Purpose Among the several methods to measure ^(222)Rn in water,the liquid scintillation counting(LSC)technique is one of the most sensitive and widely used when analysing non-saline waters by liquid extraction,providing excellent accuracy,precision and low-level detection limits.When using the liquid scintillation counter Tri-Carb 3170 TR/SL(Perkin-Elmer)it is not possible to make an automatic determination of the alpha/beta discrimination parameter,being necessary to evaluate the pulse decay discriminator(PDD)value manually to the ^(222)Rn determination.In this work,we describe the steps to perform the calibration of that type of equipment.Methods The method consists in the preparation of standard samples from a ^(226)Ra certified standard solution and the adjustment of the PDD value by hand until the percentage of alpha events reaches a plateau of a near-constant fraction of total events.The process consists in taking several measures between PDD 80 and 200 with 15 min counting time each.Within the plateau,the alpha/beta ratio was used to determine the plateau final range as well as the optimum PDD value.After that,the calibration standards and blanks were measured and the region of interest(ROI)was established by finding the maximum value for the figure of merit(FOM)in the upper and lower limits.Results The optimal PDD value of 148 was established by the alpha/beta ratio,and after that,it was possible to measure ^(226)Ra standards to perform the calibration.An efficiency of(9.758±0.035)×1^(0-1) was obtained.In routine measurements,a detection limit of about 0.50 Bq L^(-1) is achieved for a 120 min counting time.To evaluate the uncertainty budget,the uncertainties of the net count rate,the efficiency,the sample amount and the decay correction factor were considered.Conclusions A method was developed for the calibration of LSC Tri-Carb 3170 TR/SL with the optimization of the PDD using a ^(226)Ra standard solution.The acquisition to obtain the plot of the variation of the events fraction in each window(alpha and beta)in function of PDD allowed to evaluate a plateau where the fraction of events was at a minimum.Afterwards,it was possible to measure the set of ^(226)Ra standards after the equilibrium with ^(222)Rn and determine the efficiency for ^(222)Rn with a detection limit of about 0.50 Bq L^(-1) in routine analyses.
基金supported by the National Natural Science Foundation of China(11775252).
文摘Purpose Radon is a noble gas,which endangers our health.The liquid scintillator is one of the detector materials used to measure radon in the environment.But there are challenges in measuring radon using a liquid scintillator,such as independent manual operation and long measurement periods.Methods and Results We propose a liquid scintillator detector for the rapid measurement of radon,which is composed of a breathable liquid scintillator probe and photomultiplier tube.Cascade decay recognition and pulse shape discrimination(PSD)were used to select radon events.241 Am4(α)and 90Sr(β)source calibration was used to optimize the PSDfigure of merit of the liquid scintillator,and a 232Th(220Rn)diffusion source was used to verify the function of this novel detector for measuring radon.Conclusion The detector had an integrated design for sampling and measurement,which simplified the measurement steps.Thus,this novel liquid scintillator detector demonstrated promise for use in radon-detection systems.