The pressure and deflagration to detonation transition(DDT)characteristics of acetylene and oxygen flame were studied in a detonation tube.The pressure history and the flame velocity along the tube were measured with ...The pressure and deflagration to detonation transition(DDT)characteristics of acetylene and oxygen flame were studied in a detonation tube.The pressure history and the flame velocity along the tube were measured with high frequency pressure transducers and ion probes.By analyzing the data recorded in the experiment,the detonation wave pressure,post wave pressure and DDT distance were obtained,together with the effects of the initial pressure varying from 2×10^(4)Pa to 10^(5)Pa,equivalence ration from 0.3 to 1.0,and mixture concentration from 60%to 100%.It was found that the detonation pressure was decreased respectively with the decrease of initial pressure,equivalence ratio and mixture concentration,but the DDT distance was enlarged.The DDT distance was found particularly sensitive to mixture concentration.展开更多
Ignition is a key system in pulse detonation engines (PDE). As advanced ignition methods, nanosecond pulse discharge low-temperature plasma ignition is used in some combustion systems, and continuous alternating cur...Ignition is a key system in pulse detonation engines (PDE). As advanced ignition methods, nanosecond pulse discharge low-temperature plasma ignition is used in some combustion systems, and continuous alternating current (AC) driven low-temperature plasma using dielectric barrier discharge (DBD) is used for the combustion assistant. However, continuous AC driven plasmas cannot be used for ignition in pulse detonation engines. In this paper, experimental and numerical studies of pneumatic valve PDE using an AC driven low-temperature plasma igniter were described. The pneumatic valve was jointly designed with the low-temperature plasma igniter, and the numerical simulation of the cold-state flow field in the pneumatic valve showed that a complex flow in the discharge area, along with low speed, was beneficial for successful ignition. In the experiments ethylene was used as the fuel and air as oxidizing agent, ignition by an AC driven low-temperature plasma achieved multi-cycle intermittent detonation combustion on a PDE, the working frequency of the PDE reached 15 Hz and the peak pressure of the detonation wave was approximately 2.0 MPa. The experimental verifications of the feasibility in PDE ignition expanded the application field of AC driven low-temperature plasma.展开更多
文摘The pressure and deflagration to detonation transition(DDT)characteristics of acetylene and oxygen flame were studied in a detonation tube.The pressure history and the flame velocity along the tube were measured with high frequency pressure transducers and ion probes.By analyzing the data recorded in the experiment,the detonation wave pressure,post wave pressure and DDT distance were obtained,together with the effects of the initial pressure varying from 2×10^(4)Pa to 10^(5)Pa,equivalence ration from 0.3 to 1.0,and mixture concentration from 60%to 100%.It was found that the detonation pressure was decreased respectively with the decrease of initial pressure,equivalence ratio and mixture concentration,but the DDT distance was enlarged.The DDT distance was found particularly sensitive to mixture concentration.
基金supported by National Natural Science Foundation of China(No.51176001)
文摘Ignition is a key system in pulse detonation engines (PDE). As advanced ignition methods, nanosecond pulse discharge low-temperature plasma ignition is used in some combustion systems, and continuous alternating current (AC) driven low-temperature plasma using dielectric barrier discharge (DBD) is used for the combustion assistant. However, continuous AC driven plasmas cannot be used for ignition in pulse detonation engines. In this paper, experimental and numerical studies of pneumatic valve PDE using an AC driven low-temperature plasma igniter were described. The pneumatic valve was jointly designed with the low-temperature plasma igniter, and the numerical simulation of the cold-state flow field in the pneumatic valve showed that a complex flow in the discharge area, along with low speed, was beneficial for successful ignition. In the experiments ethylene was used as the fuel and air as oxidizing agent, ignition by an AC driven low-temperature plasma achieved multi-cycle intermittent detonation combustion on a PDE, the working frequency of the PDE reached 15 Hz and the peak pressure of the detonation wave was approximately 2.0 MPa. The experimental verifications of the feasibility in PDE ignition expanded the application field of AC driven low-temperature plasma.