BACKGROUND This case of gestational gingival tumor is huge and extremely rare in clinical practice.As the growth location of this gingival tumor is in the upper anterior tooth area,it seriously affects the pregnant wo...BACKGROUND This case of gestational gingival tumor is huge and extremely rare in clinical practice.As the growth location of this gingival tumor is in the upper anterior tooth area,it seriously affects the pregnant woman's speech and food,causing great pain to the patient.The use of Nd:YGA water mist laser to remove the gingival tumor resulted in minimal intraoperative bleeding,minimal adverse reactions,and good postoperative healing,which is worthy of clinical promotion and application.CASE SUMMARY The patient,a pregnant woman,reported a large lump in her mouth on the first day of postpartum treatment.Based on medical history and clinical examination,the diagnosis was diagnosed as gestational gingival tumor.Postoperative pathological biopsy also confirmed this diagnosis.The use of Nd:YAG water mist laser to remove the tumor resulted in minimal intraoperative bleeding,clear surgical field of view,short surgical time,and good postoperative healing.CONCLUSION In comparison to traditional surgery,Nd:YAG water mist laser surgery is minimally invasive,minimizes cell damage,reduces bleeding,ensures a clear field of vision,and virtually eliminates postoperative edema,carbonization,and the risk of cross infection.It has unique advantages in oral soft tissue surgery for pregnant patients.Therefore,the clinical application of Nd:YAG water mist laser for the treatment of gestational gingival tumors is an ideal choice.展开更多
A pulsed Nd:YAG (yttrium aluminum garnet) laser-based technique was employed to clad low silicon steel with preplaced Si and Fe mixed powders for high Si content. The surface morphology, microstructural evolution, ...A pulsed Nd:YAG (yttrium aluminum garnet) laser-based technique was employed to clad low silicon steel with preplaced Si and Fe mixed powders for high Si content. The surface morphology, microstructural evolution, phase composition, and Si distribution, within the obtained cladding coatings, were characterized by optical microscopy (OM), field emission scanning electron microscopy (FE-SEM), with associated energy dispersive spectroscopy (EDS), transmission electron microscopy (TEM), and X-ray diffraction (XRD). The microhardness was also measured along the depth direction of the specimens, A crack- and pore-free cladding coating through excellent metallurgical bonding with the substrate was successfully prepared on low silicon steel by means of optimized single-track and multi-track laser cladding. The phases of the coating are a-Fe, T-Fe, and FeSi. The high microhardness of the lasercladding zone is considered as an increase in Si content and as the refined microstructure produced by the laser treatment. The Si contents of the cladding coatings were about 5.8wt% in the single-track cladding and 6.5wt% in the multi-track cladding, respectively.展开更多
We report the specification of a compact and stable side diode-pumped Q-switched pulsed Nd:YAG laser. We ex- perimentally study and compare the performance of the pulsed Nd:YAG laser in the free-running and Q-switch...We report the specification of a compact and stable side diode-pumped Q-switched pulsed Nd:YAG laser. We ex- perimentally study and compare the performance of the pulsed Nd:YAG laser in the free-running and Q-switched modes at different pulse repetition rates from 1 Hz to 100 Hz. The laser output energy is stabilized by using a special configu- ration of the optical resonator. In this laser, an unsymmetrical concave-concave resonator is used and this structure helps the mode volume to be nearly fixed when the pulse repetition rate is increased. According to the experimental results in the Q-switched operation, the laser output energy is nearly constant around 70 mJ with an FWHM pulse width of 7 ns at 100 Hz. The optical-to-optical conversion efficiency in the Q-switched regime is 17.5%.展开更多
A hybrid-pumped Nd:YAG pulse laser with a double-pass two-rod configuration is presented. The focal length of offset lens is particularly studied to compensate for the thermal lens effect and depolarization. For inpu...A hybrid-pumped Nd:YAG pulse laser with a double-pass two-rod configuration is presented. The focal length of offset lens is particularly studied to compensate for the thermal lens effect and depolarization. For input pulse energy of 141 μJ with pulse duration of 754ps, the pulse laser system delivers 526mJ pulse energy and 728ps pulse width output at lO Hz with pulse profile shape preservation. The energy stability of the laser pulse is less than 3%, and the beam quality factor M2 is less than 2.26.展开更多
Laser transformation hardening (LTH) was applied to the surface of the AISI 420 martensitic stainless steel by a pulsed Nd:YAG laser to obtain optimum hardness. The influences of process parameters (laser pulse en...Laser transformation hardening (LTH) was applied to the surface of the AISI 420 martensitic stainless steel by a pulsed Nd:YAG laser to obtain optimum hardness. The influences of process parameters (laser pulse energy, duration time, and travel speed) on the depth and hardness of laser treated area were investigated. Image analysis of SEM microstructure of AISI 420 showed that plate-like carbide have almost fully and (30-40)% of globular carbide particles dissolved into the matrix after laser transformation hardening by pulsed laser and the microstructure was refined to obtain controlled tempered martensite microstructure with 450 VHN hardness.展开更多
Ce3+, Yb3+ co-doped Y3Al5O12 films were prepared by pulse laser deposition. X-ray diffraction, X-ray photoelectron spectroscopy, photoluminescence spectra were used to characterize their structural and luminescent p...Ce3+, Yb3+ co-doped Y3Al5O12 films were prepared by pulse laser deposition. X-ray diffraction, X-ray photoelectron spectroscopy, photoluminescence spectra were used to characterize their structural and luminescent properties. Near-infrared quantum cutting from the films was observed via a cooperative energy transfer from Ce3+ to Yb3+ ions. The high quantum efficiency of the films implies that Ce3+,Yb3+ co-doped Y3A15O12 films have potential application by tuning the solar spectrum to enhance the efficiency of silicon solar cells.展开更多
AIM: To study the efficacy and the safety of laser lithotripsy without direct visual control by using a balloon catheter in patients with bile duct stones that could not be extracted by standard technique. METHODS: Th...AIM: To study the efficacy and the safety of laser lithotripsy without direct visual control by using a balloon catheter in patients with bile duct stones that could not be extracted by standard technique. METHODS: The seventeen patients (7 male and 10 female; mean age 67.8 years) with difficult common bile duct (CBD) stones were not amenable for conventional endoscopic maneuvers such as sphincterotomy and mechanical lithotripsy were included in this study. Laser wavelengths of 532 nm and 1064 nm as a double pulse were applied with pulse energy of 120 mJ. The laser fiber was advanced under fluoroscopic control through the ERCP balloon catheter. Laser lithotripsy was continued until the fragment size seemed to be less than 10 mm. Endoscopic extraction of the stones and fragments was performed with the use of the Dormia basket and balloon catheter. RESULTS: Bile duct clearance was achieved in 15 of 17 patients (88%). The mean number of treatment sessions was 1.7 ± 0.6. Endoscopic stone removal could not be achieved in 2 patients (7%). Adverse effects were noted in three patients (hemobilia, pancreatitis, and cholangitis). CONCLUSION: The Frequency Doubled Double Pulse Nd:YAG (FREDDY) laser may be an effective and safe technique in treatment of difficult bile duct stones.展开更多
The experiment of Nd: YAG pulsed laser self-fluxing welding for 304 stainless steel/Ti6Al4V titanium alloy dissimilar metal was carried out. The microstructure properties of welded joint were analyzed by SEM, EDS and...The experiment of Nd: YAG pulsed laser self-fluxing welding for 304 stainless steel/Ti6Al4V titanium alloy dissimilar metal was carried out. The microstructure properties of welded joint were analyzed by SEM, EDS and XRD. The equilibrium lattice constants, enthalpies of formation, cohesive energies, mechanical properties, Debye temperatures and valence electron structures of Ti-Fe intermetallic compounds (IMCs) were calculated by the first principle pseudopotential plane wave method based on density functional theory (DFT). According to the thermodynamic data of Ti-Fe-Cr compounds, the Gibbs free energy per mole of compound at different temperatures was calculated and their thermal stability was compared. The results show that there are no macroscopic cracks in the welded joints, and the IMCs distributed evenly along the welding interface exhibits 3 distinct layers of microstructure with different colors. The welds interface generates IMCs of TiFe, TiFe 2 and a small amount of Ti 5Cr 7Fe 17 IMCs. Ti-Fe IMCs with high thermodynamic stability and easy alloying formation. The results of Gibbs free energies show that the sequence of precipitates in the interface is Ti 5Cr 7Fe 17 , TiFe 2 and TiFe in high temperature during the metallurgical reaction. The G/B values of Ti-Fe IMCs are greater than the critical value of 0.5, indicating that it is an intrinsic brittleness.展开更多
We successfully obtain a high-average-power high-stability Q-switched green laser based on diode-side-pumped composite ceramic Nd:YAG in a straight piano-concave cavity. The temperature distribution in composite cera...We successfully obtain a high-average-power high-stability Q-switched green laser based on diode-side-pumped composite ceramic Nd:YAG in a straight piano-concave cavity. The temperature distribution in composite ceramic Nd:YAG crystal is numerically analyzed and compared with that of conventional Nd:YAG crystal. By using a composite ceramic Nd:YAG rod and a type-II high gray track resistance KTP (HGTR-KTP) crystal, a green laser with an average output power of 165 W is obtained at a repetition rate of 25 kHz, with a diode-to-green optical conversion of 14.68%, and a pulse width of 162 ns. To the best of our knowledge, both the output power and optical-to-optical efficiency are the highest values for green laser systems with intracavity frequency doubling of this novel composite ceramic Nd:YAG laser to date. The power fluctuation at around 160 W is lower than 0.3% in 2.5 hours.展开更多
We first experimentally demonstrate a laser-diode end-pumped self-Q-switched and mode-locked Nd,Cr:YAG green laser with a KTP crystal as the intra-cavity frequency doubler. The device produces an average output power...We first experimentally demonstrate a laser-diode end-pumped self-Q-switched and mode-locked Nd,Cr:YAG green laser with a KTP crystal as the intra-cavity frequency doubler. The device produces an average output power of 680 mW at 532 nm. The corresponding pulse width of the Q-switched envelope of the green laser is 170 + 20 ns. The mode-locked pulses have a repetition rate of approximately 183 MHz and the average pulse duration is estimated to be around sub-nanosecond. It is found that the intra-cavity frequency doubling greatly improves the modulation depth and stability of the mode-locked pulses within the Q-switched envelope.展开更多
AIM: To evaluate the outcome of laser iridotomy using532-nm Nd: YAG laser(PASCAL) with short pulse duration and Nd: YAG laser compared to conventional combined laser iridotomy.METHODS: Retrospective, nonrandomized, co...AIM: To evaluate the outcome of laser iridotomy using532-nm Nd: YAG laser(PASCAL) with short pulse duration and Nd: YAG laser compared to conventional combined laser iridotomy.METHODS: Retrospective, nonrandomized, comparative case series. Forty-five eyes of 34 patients underwent laser iridotomy. Twenty-two eyes underwent iridotomy using short duration PASCAL and Nd: YAG laser, and 23 eyes underwent iridotomy using conventional combined laser method. The average settings of PASCAL were60 μm and 700-900 m W with a short duration of 0.01 s to reduce the total applied energy. The conventional laser was 50 μm and 700-900 m W for 0.1s. After photocoagulation with these laser, the Nd: YAG laser was added in each group. Endothelial cell counts of preiridotomy and 2mo after iridotomy were measured and compared.RESULTS: All eyes completed iridotomy successfully.The total energy used in the PASCAL group was 1.85 ±1.17 J. Compared to conventional laser 13.25 ±1.67 J, the energy used was very small due to the short exposure time of PASCAL. Endothelial cell counts were reduced by0.88% in the PASCAL group and 6.72% in the conventional laser group(P =0.044). The change in corneal endothelial cell counts before and after iridotomy was significant in conventional combined laser iridotomy group(P =0.004).CONCLUSION: Combined PASCAL and Nd:YAG laseriridotomy is an effective and safe technique in the dark brown irides of Asians. Furthermore, the short duration of exposure in PASCAL offers the advantages of reducing the total energy used and minimizing the corneal damage.展开更多
A diode-end-pumped Q-switched high-efficiency Nd, Cr:YAG laser with simultaneous dual-wavelength emission at 946nm and 1.3μm is demonstrated. The maximum output power of 1.93 W with simultaneous dual-wavelength oper...A diode-end-pumped Q-switched high-efficiency Nd, Cr:YAG laser with simultaneous dual-wavelength emission at 946nm and 1.3μm is demonstrated. The maximum output power of 1.93 W with simultaneous dual-wavelength operation is achieved at an absorbed pump power of 13.32 W and an absorbed slope efficiency of 15.15%. The maximum optical-optical efficiency is 14.49% with pulse widths of 16.38ns at 946nm and 26.65ns at 1.3μm. A maximum total repetition rate of 43.25 kHz is obtained.展开更多
By using a Nd: YAG laser welding system devised for transmitting continuous, rectangular and pulsed waveforms, comprehensive and deep investigation is focused on the effects of several parameters of rectangular wavefo...By using a Nd: YAG laser welding system devised for transmitting continuous, rectangular and pulsed waveforms, comprehensive and deep investigation is focused on the effects of several parameters of rectangular waveform and pulsed output wave superimposed on a rectangular waveform on the penetration depth of weld. Research results indicate that the average power, duty cycle, frequency and peak power of rectangular wave affect the weld penetration depth to different extent. Results of experiments and analysis also indicate that the pulse delay time, pulse width and the power ratio of pulse to rectangular waveform seriously influence the penetration when the pulsed wave is superimposed on a rectangular waveform.展开更多
文摘BACKGROUND This case of gestational gingival tumor is huge and extremely rare in clinical practice.As the growth location of this gingival tumor is in the upper anterior tooth area,it seriously affects the pregnant woman's speech and food,causing great pain to the patient.The use of Nd:YGA water mist laser to remove the gingival tumor resulted in minimal intraoperative bleeding,minimal adverse reactions,and good postoperative healing,which is worthy of clinical promotion and application.CASE SUMMARY The patient,a pregnant woman,reported a large lump in her mouth on the first day of postpartum treatment.Based on medical history and clinical examination,the diagnosis was diagnosed as gestational gingival tumor.Postoperative pathological biopsy also confirmed this diagnosis.The use of Nd:YAG water mist laser to remove the tumor resulted in minimal intraoperative bleeding,clear surgical field of view,short surgical time,and good postoperative healing.CONCLUSION In comparison to traditional surgery,Nd:YAG water mist laser surgery is minimally invasive,minimizes cell damage,reduces bleeding,ensures a clear field of vision,and virtually eliminates postoperative edema,carbonization,and the risk of cross infection.It has unique advantages in oral soft tissue surgery for pregnant patients.Therefore,the clinical application of Nd:YAG water mist laser for the treatment of gestational gingival tumors is an ideal choice.
基金the National Natural Science Foundation of China (No.50474084).
文摘A pulsed Nd:YAG (yttrium aluminum garnet) laser-based technique was employed to clad low silicon steel with preplaced Si and Fe mixed powders for high Si content. The surface morphology, microstructural evolution, phase composition, and Si distribution, within the obtained cladding coatings, were characterized by optical microscopy (OM), field emission scanning electron microscopy (FE-SEM), with associated energy dispersive spectroscopy (EDS), transmission electron microscopy (TEM), and X-ray diffraction (XRD). The microhardness was also measured along the depth direction of the specimens, A crack- and pore-free cladding coating through excellent metallurgical bonding with the substrate was successfully prepared on low silicon steel by means of optimized single-track and multi-track laser cladding. The phases of the coating are a-Fe, T-Fe, and FeSi. The high microhardness of the lasercladding zone is considered as an increase in Si content and as the refined microstructure produced by the laser treatment. The Si contents of the cladding coatings were about 5.8wt% in the single-track cladding and 6.5wt% in the multi-track cladding, respectively.
文摘We report the specification of a compact and stable side diode-pumped Q-switched pulsed Nd:YAG laser. We ex- perimentally study and compare the performance of the pulsed Nd:YAG laser in the free-running and Q-switched modes at different pulse repetition rates from 1 Hz to 100 Hz. The laser output energy is stabilized by using a special configu- ration of the optical resonator. In this laser, an unsymmetrical concave-concave resonator is used and this structure helps the mode volume to be nearly fixed when the pulse repetition rate is increased. According to the experimental results in the Q-switched operation, the laser output energy is nearly constant around 70 mJ with an FWHM pulse width of 7 ns at 100 Hz. The optical-to-optical conversion efficiency in the Q-switched regime is 17.5%.
文摘A hybrid-pumped Nd:YAG pulse laser with a double-pass two-rod configuration is presented. The focal length of offset lens is particularly studied to compensate for the thermal lens effect and depolarization. For input pulse energy of 141 μJ with pulse duration of 754ps, the pulse laser system delivers 526mJ pulse energy and 728ps pulse width output at lO Hz with pulse profile shape preservation. The energy stability of the laser pulse is less than 3%, and the beam quality factor M2 is less than 2.26.
基金supported by the Tarbiat Modares University and Iranian National Center for Laser Science and Technology
文摘Laser transformation hardening (LTH) was applied to the surface of the AISI 420 martensitic stainless steel by a pulsed Nd:YAG laser to obtain optimum hardness. The influences of process parameters (laser pulse energy, duration time, and travel speed) on the depth and hardness of laser treated area were investigated. Image analysis of SEM microstructure of AISI 420 showed that plate-like carbide have almost fully and (30-40)% of globular carbide particles dissolved into the matrix after laser transformation hardening by pulsed laser and the microstructure was refined to obtain controlled tempered martensite microstructure with 450 VHN hardness.
基金Funded by the China Postdoctoral Science Foundation(No.2012M511801)the National Natural Science Foundation of China(Nos.11474104 and 51372092)
文摘Ce3+, Yb3+ co-doped Y3Al5O12 films were prepared by pulse laser deposition. X-ray diffraction, X-ray photoelectron spectroscopy, photoluminescence spectra were used to characterize their structural and luminescent properties. Near-infrared quantum cutting from the films was observed via a cooperative energy transfer from Ce3+ to Yb3+ ions. The high quantum efficiency of the films implies that Ce3+,Yb3+ co-doped Y3A15O12 films have potential application by tuning the solar spectrum to enhance the efficiency of silicon solar cells.
基金The 2007 research fund of Wonkwang University and Wonkwang Clinical Research Institute
文摘AIM: To study the efficacy and the safety of laser lithotripsy without direct visual control by using a balloon catheter in patients with bile duct stones that could not be extracted by standard technique. METHODS: The seventeen patients (7 male and 10 female; mean age 67.8 years) with difficult common bile duct (CBD) stones were not amenable for conventional endoscopic maneuvers such as sphincterotomy and mechanical lithotripsy were included in this study. Laser wavelengths of 532 nm and 1064 nm as a double pulse were applied with pulse energy of 120 mJ. The laser fiber was advanced under fluoroscopic control through the ERCP balloon catheter. Laser lithotripsy was continued until the fragment size seemed to be less than 10 mm. Endoscopic extraction of the stones and fragments was performed with the use of the Dormia basket and balloon catheter. RESULTS: Bile duct clearance was achieved in 15 of 17 patients (88%). The mean number of treatment sessions was 1.7 ± 0.6. Endoscopic stone removal could not be achieved in 2 patients (7%). Adverse effects were noted in three patients (hemobilia, pancreatitis, and cholangitis). CONCLUSION: The Frequency Doubled Double Pulse Nd:YAG (FREDDY) laser may be an effective and safe technique in treatment of difficult bile duct stones.
基金supported by the National High Technology Research and Development Program of China(Grant No.2013AA041003)the National Natural Science Foundation of China(Grant No.51365039)
文摘The experiment of Nd: YAG pulsed laser self-fluxing welding for 304 stainless steel/Ti6Al4V titanium alloy dissimilar metal was carried out. The microstructure properties of welded joint were analyzed by SEM, EDS and XRD. The equilibrium lattice constants, enthalpies of formation, cohesive energies, mechanical properties, Debye temperatures and valence electron structures of Ti-Fe intermetallic compounds (IMCs) were calculated by the first principle pseudopotential plane wave method based on density functional theory (DFT). According to the thermodynamic data of Ti-Fe-Cr compounds, the Gibbs free energy per mole of compound at different temperatures was calculated and their thermal stability was compared. The results show that there are no macroscopic cracks in the welded joints, and the IMCs distributed evenly along the welding interface exhibits 3 distinct layers of microstructure with different colors. The welds interface generates IMCs of TiFe, TiFe 2 and a small amount of Ti 5Cr 7Fe 17 IMCs. Ti-Fe IMCs with high thermodynamic stability and easy alloying formation. The results of Gibbs free energies show that the sequence of precipitates in the interface is Ti 5Cr 7Fe 17 , TiFe 2 and TiFe in high temperature during the metallurgical reaction. The G/B values of Ti-Fe IMCs are greater than the critical value of 0.5, indicating that it is an intrinsic brittleness.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 61107086, 61172010, and 61101058)the Science and Technology Committee of Tianjin, China (Grant No. 11JCYBJC01100)the National High Technology Research and Development Program of China (Grant No. 2011AA010205)
文摘We successfully obtain a high-average-power high-stability Q-switched green laser based on diode-side-pumped composite ceramic Nd:YAG in a straight piano-concave cavity. The temperature distribution in composite ceramic Nd:YAG crystal is numerically analyzed and compared with that of conventional Nd:YAG crystal. By using a composite ceramic Nd:YAG rod and a type-II high gray track resistance KTP (HGTR-KTP) crystal, a green laser with an average output power of 165 W is obtained at a repetition rate of 25 kHz, with a diode-to-green optical conversion of 14.68%, and a pulse width of 162 ns. To the best of our knowledge, both the output power and optical-to-optical efficiency are the highest values for green laser systems with intracavity frequency doubling of this novel composite ceramic Nd:YAG laser to date. The power fluctuation at around 160 W is lower than 0.3% in 2.5 hours.
基金Project supported by the National Natural Science Foundation of China (Grant Nos 60278024 and 60438020).
文摘We first experimentally demonstrate a laser-diode end-pumped self-Q-switched and mode-locked Nd,Cr:YAG green laser with a KTP crystal as the intra-cavity frequency doubler. The device produces an average output power of 680 mW at 532 nm. The corresponding pulse width of the Q-switched envelope of the green laser is 170 + 20 ns. The mode-locked pulses have a repetition rate of approximately 183 MHz and the average pulse duration is estimated to be around sub-nanosecond. It is found that the intra-cavity frequency doubling greatly improves the modulation depth and stability of the mode-locked pulses within the Q-switched envelope.
文摘AIM: To evaluate the outcome of laser iridotomy using532-nm Nd: YAG laser(PASCAL) with short pulse duration and Nd: YAG laser compared to conventional combined laser iridotomy.METHODS: Retrospective, nonrandomized, comparative case series. Forty-five eyes of 34 patients underwent laser iridotomy. Twenty-two eyes underwent iridotomy using short duration PASCAL and Nd: YAG laser, and 23 eyes underwent iridotomy using conventional combined laser method. The average settings of PASCAL were60 μm and 700-900 m W with a short duration of 0.01 s to reduce the total applied energy. The conventional laser was 50 μm and 700-900 m W for 0.1s. After photocoagulation with these laser, the Nd: YAG laser was added in each group. Endothelial cell counts of preiridotomy and 2mo after iridotomy were measured and compared.RESULTS: All eyes completed iridotomy successfully.The total energy used in the PASCAL group was 1.85 ±1.17 J. Compared to conventional laser 13.25 ±1.67 J, the energy used was very small due to the short exposure time of PASCAL. Endothelial cell counts were reduced by0.88% in the PASCAL group and 6.72% in the conventional laser group(P =0.044). The change in corneal endothelial cell counts before and after iridotomy was significant in conventional combined laser iridotomy group(P =0.004).CONCLUSION: Combined PASCAL and Nd:YAG laseriridotomy is an effective and safe technique in the dark brown irides of Asians. Furthermore, the short duration of exposure in PASCAL offers the advantages of reducing the total energy used and minimizing the corneal damage.
基金Supported by the National Basic Research Program of China under Grant No 2013CB632704
文摘A diode-end-pumped Q-switched high-efficiency Nd, Cr:YAG laser with simultaneous dual-wavelength emission at 946nm and 1.3μm is demonstrated. The maximum output power of 1.93 W with simultaneous dual-wavelength operation is achieved at an absorbed pump power of 13.32 W and an absorbed slope efficiency of 15.15%. The maximum optical-optical efficiency is 14.49% with pulse widths of 16.38ns at 946nm and 26.65ns at 1.3μm. A maximum total repetition rate of 43.25 kHz is obtained.
基金Sponsored by National Science Fund!( 59881 0 0 2 )
文摘By using a Nd: YAG laser welding system devised for transmitting continuous, rectangular and pulsed waveforms, comprehensive and deep investigation is focused on the effects of several parameters of rectangular waveform and pulsed output wave superimposed on a rectangular waveform on the penetration depth of weld. Research results indicate that the average power, duty cycle, frequency and peak power of rectangular wave affect the weld penetration depth to different extent. Results of experiments and analysis also indicate that the pulse delay time, pulse width and the power ratio of pulse to rectangular waveform seriously influence the penetration when the pulsed wave is superimposed on a rectangular waveform.