A compact pneumatic pulse-jet pump with a Venturi-like reverse flow diverter,which consists of a nozzle and diffuser,is designed for lifting and transporting a hazardous fluid through a narrow mounting hole.The pumpin...A compact pneumatic pulse-jet pump with a Venturi-like reverse flow diverter,which consists of a nozzle and diffuser,is designed for lifting and transporting a hazardous fluid through a narrow mounting hole.The pumping performance for a liquid mixture or a liquid-solid mixture is examined in terms of the effects of liquid viscosity,particle mass concentration,lifting height,and compression pressure.Results reveal that the pumping performance of the compact pneumatic pulse-jet pump is controlled by jet inertia and the flow resistance of the riser tube positioned after the diffuser.The capacity of the compact pneumatic pulse-jet pump increases with compression pressure and decreases with liquid viscosity.However,even for a liquid mixture with a high viscosity of 7.38 mPa·s,a pumping capacity of 170.7 L·h-1 was observed.For a liquid mixture,two dimensionless indices of performance were found to be the ratio of Euler numbers Euout/EuDV and the suction factor q.As the liquid-solid mixture was lifted to elevation of 6.74 m by the compact pump,the particle size distributions of the liquid-solid mixture in the tank and from the riser tube outlet were determined by a particle size analyzer and found to coincide well.展开更多
Based on nuclear power plant(NPP) best-estimate transient analysis with RELAP5 / MOD3 code,the reactor point kinetics model in RELAP5 / MOD3 code is replaced by the two-group,3-D space and time dependent neutron kinet...Based on nuclear power plant(NPP) best-estimate transient analysis with RELAP5 / MOD3 code,the reactor point kinetics model in RELAP5 / MOD3 code is replaced by the two-group,3-D space and time dependent neutron kinetic model,and two-fluid model is replaced by drift flux model.A coupled three-dimensional physics and thermal-hydrodynamics model is used to develop its corresponding computing code,thus simulating natural circulation of single-phase flow for the PWR.In this paper,we report the forward and reverse flow distribution in the inverted U-tubes of the steam generator(SG) under some typical operating conditions in the natural circulation case, and analyze the influence of main coolant pump resistance on the forward and reverse flow distribution.The calculation results show that,the pressure drop between SG inlet and outlet plenum decreases,and the SG inlet and outlet mass flow decrease with an increased main coolant pump resistance,but net mass flux of reverse flow in inverted U-tubes,and the ratio of mass flow in all reverse flow tubes to that of main coolant pipeline increase, meanwhile,the secondary steam load is invariable in this process.展开更多
BACKGROUND Twin reversed arterial perfusion(TRAP) sequence is an extremely rare congenital anomaly in monochorionic(MC) twins.The condition is characterized by a malformed fetus(acardiac twin) without cardiac activiti...BACKGROUND Twin reversed arterial perfusion(TRAP) sequence is an extremely rare congenital anomaly in monochorionic(MC) twins.The condition is characterized by a malformed fetus(acardiac twin) without cardiac activities being perfused by a structurally normal one(pump twin) via an artery-to-artery anastomosis in a reverse direction.CASE SUMMARY We described the first case of TRAP to receive laser surgery in Vietnam.The 26-wk pregnancy was originally misdiagnosed in another hospital as MC twins with single intrauterine fetal death.Following admission to our center,the diagnosis was amended to a 26-wk TRAP sequence stage IIb.The acardiac twin was 7.5 cm at the longest length,the ratio of the weight of the acardiac twin to the weight of the pump twin was more than 90%,the pump twin showed fetal distress with absent diastolic flow in umbilical artery of pump twin,and the peak systolic velocity in the middle cerebral artery = 1.6 Mo M.We performed emergency laser photocoagulation of the acardiac twin’s umbilical cord.After surgery,we successfully maintained the pregnancy for 8 wk and ended it electively by cesarean section at 34 wk of gestation due to rupture of membranes.CONCLUSION TRAP should be appropriately diagnosed and treated early to avoid complications of the pump twin.Fetoscopic laser photocoagulation is a new and effective treatment for this condition.展开更多
文摘A compact pneumatic pulse-jet pump with a Venturi-like reverse flow diverter,which consists of a nozzle and diffuser,is designed for lifting and transporting a hazardous fluid through a narrow mounting hole.The pumping performance for a liquid mixture or a liquid-solid mixture is examined in terms of the effects of liquid viscosity,particle mass concentration,lifting height,and compression pressure.Results reveal that the pumping performance of the compact pneumatic pulse-jet pump is controlled by jet inertia and the flow resistance of the riser tube positioned after the diffuser.The capacity of the compact pneumatic pulse-jet pump increases with compression pressure and decreases with liquid viscosity.However,even for a liquid mixture with a high viscosity of 7.38 mPa·s,a pumping capacity of 170.7 L·h-1 was observed.For a liquid mixture,two dimensionless indices of performance were found to be the ratio of Euler numbers Euout/EuDV and the suction factor q.As the liquid-solid mixture was lifted to elevation of 6.74 m by the compact pump,the particle size distributions of the liquid-solid mixture in the tank and from the riser tube outlet were determined by a particle size analyzer and found to coincide well.
文摘Based on nuclear power plant(NPP) best-estimate transient analysis with RELAP5 / MOD3 code,the reactor point kinetics model in RELAP5 / MOD3 code is replaced by the two-group,3-D space and time dependent neutron kinetic model,and two-fluid model is replaced by drift flux model.A coupled three-dimensional physics and thermal-hydrodynamics model is used to develop its corresponding computing code,thus simulating natural circulation of single-phase flow for the PWR.In this paper,we report the forward and reverse flow distribution in the inverted U-tubes of the steam generator(SG) under some typical operating conditions in the natural circulation case, and analyze the influence of main coolant pump resistance on the forward and reverse flow distribution.The calculation results show that,the pressure drop between SG inlet and outlet plenum decreases,and the SG inlet and outlet mass flow decrease with an increased main coolant pump resistance,but net mass flux of reverse flow in inverted U-tubes,and the ratio of mass flow in all reverse flow tubes to that of main coolant pipeline increase, meanwhile,the secondary steam load is invariable in this process.
文摘BACKGROUND Twin reversed arterial perfusion(TRAP) sequence is an extremely rare congenital anomaly in monochorionic(MC) twins.The condition is characterized by a malformed fetus(acardiac twin) without cardiac activities being perfused by a structurally normal one(pump twin) via an artery-to-artery anastomosis in a reverse direction.CASE SUMMARY We described the first case of TRAP to receive laser surgery in Vietnam.The 26-wk pregnancy was originally misdiagnosed in another hospital as MC twins with single intrauterine fetal death.Following admission to our center,the diagnosis was amended to a 26-wk TRAP sequence stage IIb.The acardiac twin was 7.5 cm at the longest length,the ratio of the weight of the acardiac twin to the weight of the pump twin was more than 90%,the pump twin showed fetal distress with absent diastolic flow in umbilical artery of pump twin,and the peak systolic velocity in the middle cerebral artery = 1.6 Mo M.We performed emergency laser photocoagulation of the acardiac twin’s umbilical cord.After surgery,we successfully maintained the pregnancy for 8 wk and ended it electively by cesarean section at 34 wk of gestation due to rupture of membranes.CONCLUSION TRAP should be appropriately diagnosed and treated early to avoid complications of the pump twin.Fetoscopic laser photocoagulation is a new and effective treatment for this condition.