In order to study the mechanism of the vortex generation at the bottom of the pump sump below the flare tube,twenty pressure pulsation monitoring points were arranged at the bottom of the pump sump below the flare tub...In order to study the mechanism of the vortex generation at the bottom of the pump sump below the flare tube,twenty pressure pulsation monitoring points were arranged at the bottom of the pump sump below the flare tube,and the pressure fluctuation experiments were carried out under different flow conditions.The experimental results show that the frequency of pressure fluctuation at the bottom of the pump sump is twice of the rotational frequency of the impeller blade.The vortex below the flare tube is easy to generate under the large flow conditions and mainly concentrates at the right front position below the flare tube.The position of the vortex occurring is corresponding to the position of the low-pressure region below flare tube.展开更多
The dynamics of air entrainment and suppression schemes in a pump sump are investigated. Four different turbulence models(standard k-ε model, realizable k-ε model, renormalization group(RNG) k-ε model and shear-str...The dynamics of air entrainment and suppression schemes in a pump sump are investigated. Four different turbulence models(standard k-ε model, realizable k-ε model, renormalization group(RNG) k-ε model and shear-stress transport(SST) k-ω model) and the volume of fluid(VOF) multiphase model are employed to simulate the three-dimensional unsteady turbulent flow in a pump sump. The dynamic processes of air entrainment are simulated under conditions of relatively high discharge and low submergence; the mechanism of air entrainment is discussed in detail. Then suppression means for air entrainment is adopted by placing a circular plate on the intake pipe at three different heights. The results show: the position and structure of the free-surface vortices, sidewall-attached vortices, back wall-attached vortices, and floor-attached vortices calculated by SST k-ω turbulence model agree well with the experimental data. The two main contributors for air entrainment are pressure difference and vortex strength. By placing a circular plate in the middle of the intake pipe under water, air entrainment is suppressed because vortex strength is reduced.展开更多
Vortices in the flow of a pump sump present an important problem in pump station operation. In the present study, the flow patterns in two model pump sumps with specially designed structures are analyzed using the p...Vortices in the flow of a pump sump present an important problem in pump station operation. In the present study, the flow patterns in two model pump sumps with specially designed structures are analyzed using the particle image velocimetry (PIV) technique. The data is analyzed to reveal a number of parameters including the internal flow field with velocity distribution, the streamline distribution, and the turbulent kinetic energy. The analysis certifies that a modified pump with added T-type baffle below the sump exhibits good performance for realistic working conditions.展开更多
基金China Nature Science Funds(51279173)“The 12th Five-year”Key Project of National Science and Technology Support Plan(2015BAD20B01)Jiangsu Water Conservancy Science and Technology Project(2017031)
文摘In order to study the mechanism of the vortex generation at the bottom of the pump sump below the flare tube,twenty pressure pulsation monitoring points were arranged at the bottom of the pump sump below the flare tube,and the pressure fluctuation experiments were carried out under different flow conditions.The experimental results show that the frequency of pressure fluctuation at the bottom of the pump sump is twice of the rotational frequency of the impeller blade.The vortex below the flare tube is easy to generate under the large flow conditions and mainly concentrates at the right front position below the flare tube.The position of the vortex occurring is corresponding to the position of the low-pressure region below flare tube.
基金supported by the National Natural Science Foundation of China(Grant No.51422906)
文摘The dynamics of air entrainment and suppression schemes in a pump sump are investigated. Four different turbulence models(standard k-ε model, realizable k-ε model, renormalization group(RNG) k-ε model and shear-stress transport(SST) k-ω model) and the volume of fluid(VOF) multiphase model are employed to simulate the three-dimensional unsteady turbulent flow in a pump sump. The dynamic processes of air entrainment are simulated under conditions of relatively high discharge and low submergence; the mechanism of air entrainment is discussed in detail. Then suppression means for air entrainment is adopted by placing a circular plate on the intake pipe at three different heights. The results show: the position and structure of the free-surface vortices, sidewall-attached vortices, back wall-attached vortices, and floor-attached vortices calculated by SST k-ω turbulence model agree well with the experimental data. The two main contributors for air entrainment are pressure difference and vortex strength. By placing a circular plate in the middle of the intake pipe under water, air entrainment is suppressed because vortex strength is reduced.
文摘Vortices in the flow of a pump sump present an important problem in pump station operation. In the present study, the flow patterns in two model pump sumps with specially designed structures are analyzed using the particle image velocimetry (PIV) technique. The data is analyzed to reveal a number of parameters including the internal flow field with velocity distribution, the streamline distribution, and the turbulent kinetic energy. The analysis certifies that a modified pump with added T-type baffle below the sump exhibits good performance for realistic working conditions.