Double resonance optical pumping spectroscopy has an outstanding advantage of high signal-to-noise ratio, thus having potential applications in precision measurement. With the counter propagated 780nm and 776nm laser ...Double resonance optical pumping spectroscopy has an outstanding advantage of high signal-to-noise ratio, thus having potential applications in precision measurement. With the counter propagated 780nm and 776nm laser beams acting on a rubidium vapor cell, the high resolution spectrum of 5S1/2 - 5P3/2 - 5D5/2 ladder-type transition of ST Rb atoms is obtained by monitoring the population of the 5S1/2 ground state. The dependence of the spectroscopy lineshape on the probe and coupling fields are comprehensively studied in theory and experiment. This research is helpful for measurement of fundamental physical constants by high resolution spectroscopy.展开更多
The influences of the four different surface dipole sources in a centrifugal pump on the acoustic calculating accuracy are studied in this paper, by using the CFD combined with the Lighthill acoustic analogy methods. ...The influences of the four different surface dipole sources in a centrifugal pump on the acoustic calculating accuracy are studied in this paper, by using the CFD combined with the Lighthill acoustic analogy methods. Firstly, the unsteady flow in the pump is solved based on the large eddy simulation method and the pressure pulsations on the four different surfaces are obtained. The four surfaces include the volute surface, the discharge pipe surface, the inner surface of the pump cavity, and the interfaces between the impeller and the stationary parts as well as the outer surface of the impeller. Then, the software Sysnoise is employed to interpolate the pressure fluctuations onto the corresponding surfaces of the acoustic model. The Fast Fourier Transform with a Hanning window is used to analyze the pressure fluctuations and transform them into the surface dipole sources. The direct boundary element method is applied to calculate the noise radiated from the dipole sources. And the predicted sound pressure level is compared with the experimental data. The results show that the pressure fluctuations on the discharge pipe surface and the outer surface of the impeller have little effect on the acoustic simulation results. The pressure pulsations on the inner surface of the pump cavity play an important role in the internal flow and the acoustic simulation. The acoustic calculating error can be reduced by about 7% through considering the effect of the pump cavity. The sound pressure distributions show that the sound pressure level increases with the growing flow rate, with the largest magnitude at the tongue zone.展开更多
The centrifugal pumps usually work at various rotational speeds. The variation in the rotational speeds will affect the internal flow, the external performance, and the anti-cavitation performance of the pump. In orde...The centrifugal pumps usually work at various rotational speeds. The variation in the rotational speeds will affect the internal flow, the external performance, and the anti-cavitation performance of the pump. In order to improve the anti-cavitation performance of the centrifugal pumps, variable-pitch inducers are placed upstream of the impeller. Because the rotational speeds directly affect the flow and the performance of the pump, it is essential to characterize the performance of the pump with a variable-pitch inducer at various rotational speeds. In this paper, the simulations and the experimental tests of a centrifugal pump with a variable-pitch inducer are designed and carried out under various rotational speed conditions. Navier-Stokes equations, coupled with a Reynolds average simulation approach, are used in the simulations. In the experimental tests, the external and anti-cavitation performances of the pump are investigated in a closed system. The following results are obtained from the simulations. Firstly, the velocity in the passage of the inducer rises with the increase of the rotational speed. Secondly, the static pressure escalates on the inducer and the impeller with the increase of the rotational speed. Thirdly, the static pressure distribution on the inducer and the impeller is asymmetric. Fourthly, the anti-cavitation performance of the pump deteriorates with the increase of the rotational speed. Additional results are gathered from an analysis of the experiments. H-Q curves are similar parabolas at various rotational speeds, while η-Q curves are similar parabolas only when n ≤6 000 r/min. The anti-cavitation performance of the pump deteriorates with the increase of the rotational speed. Finally, the simulation results are found to be consistent with the experimental results.展开更多
基金Supported by the National Key R&D Program of China under Grant No 2017YFA0304203the National Natural Science Foundation of China under Grant Nos 61575116,61705122,61728502,91736209 and 11434007+2 种基金the Changjiang Scholars and Innovative Research Team in University of Ministry of Education of China under Grant No IRT13076the Program for Sanjin Scholars of Shanxi Province,the Applied Basic Research Project of Shanxi Province under Grant No 201701D221004the Fund for Shanxi ‘1331 Project’ Key Subjects Construction
文摘Double resonance optical pumping spectroscopy has an outstanding advantage of high signal-to-noise ratio, thus having potential applications in precision measurement. With the counter propagated 780nm and 776nm laser beams acting on a rubidium vapor cell, the high resolution spectrum of 5S1/2 - 5P3/2 - 5D5/2 ladder-type transition of ST Rb atoms is obtained by monitoring the population of the 5S1/2 ground state. The dependence of the spectroscopy lineshape on the probe and coupling fields are comprehensively studied in theory and experiment. This research is helpful for measurement of fundamental physical constants by high resolution spectroscopy.
基金supported by the National Natural Science Foun-dation of China(Grant Nos.51309120,51509109)the Natio-nal Key Technology Support Program of China(Grant No.2013BAF01B02)the Jiangsu Province Science and Technology Support Program of China(Grant Nos.BA2013127,E2014879 and BA2015169)
文摘The influences of the four different surface dipole sources in a centrifugal pump on the acoustic calculating accuracy are studied in this paper, by using the CFD combined with the Lighthill acoustic analogy methods. Firstly, the unsteady flow in the pump is solved based on the large eddy simulation method and the pressure pulsations on the four different surfaces are obtained. The four surfaces include the volute surface, the discharge pipe surface, the inner surface of the pump cavity, and the interfaces between the impeller and the stationary parts as well as the outer surface of the impeller. Then, the software Sysnoise is employed to interpolate the pressure fluctuations onto the corresponding surfaces of the acoustic model. The Fast Fourier Transform with a Hanning window is used to analyze the pressure fluctuations and transform them into the surface dipole sources. The direct boundary element method is applied to calculate the noise radiated from the dipole sources. And the predicted sound pressure level is compared with the experimental data. The results show that the pressure fluctuations on the discharge pipe surface and the outer surface of the impeller have little effect on the acoustic simulation results. The pressure pulsations on the inner surface of the pump cavity play an important role in the internal flow and the acoustic simulation. The acoustic calculating error can be reduced by about 7% through considering the effect of the pump cavity. The sound pressure distributions show that the sound pressure level increases with the growing flow rate, with the largest magnitude at the tongue zone.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.51406185,51579225)the Third Level 151 Talent Project in Zhejiang Province
文摘The centrifugal pumps usually work at various rotational speeds. The variation in the rotational speeds will affect the internal flow, the external performance, and the anti-cavitation performance of the pump. In order to improve the anti-cavitation performance of the centrifugal pumps, variable-pitch inducers are placed upstream of the impeller. Because the rotational speeds directly affect the flow and the performance of the pump, it is essential to characterize the performance of the pump with a variable-pitch inducer at various rotational speeds. In this paper, the simulations and the experimental tests of a centrifugal pump with a variable-pitch inducer are designed and carried out under various rotational speed conditions. Navier-Stokes equations, coupled with a Reynolds average simulation approach, are used in the simulations. In the experimental tests, the external and anti-cavitation performances of the pump are investigated in a closed system. The following results are obtained from the simulations. Firstly, the velocity in the passage of the inducer rises with the increase of the rotational speed. Secondly, the static pressure escalates on the inducer and the impeller with the increase of the rotational speed. Thirdly, the static pressure distribution on the inducer and the impeller is asymmetric. Fourthly, the anti-cavitation performance of the pump deteriorates with the increase of the rotational speed. Additional results are gathered from an analysis of the experiments. H-Q curves are similar parabolas at various rotational speeds, while η-Q curves are similar parabolas only when n ≤6 000 r/min. The anti-cavitation performance of the pump deteriorates with the increase of the rotational speed. Finally, the simulation results are found to be consistent with the experimental results.