Purpose:To investigate the correlation between vestibular hydrops(VH),cochlearhydrops(CH),vestibular aqueduct non-visibility(VANV),and visually increased perilymphatic enhancement(VIPE)with the findings of pure-tone a...Purpose:To investigate the correlation between vestibular hydrops(VH),cochlearhydrops(CH),vestibular aqueduct non-visibility(VANV),and visually increased perilymphatic enhancement(VIPE)with the findings of pure-tone audiometry(PTA)in Meniere’s disease(MD)patients.Methods:In this cross-sectional study,53 ears belonging to 48 patients were divided into two groups and evaluated.In group“MD patients,”there were 24 ears of 19 patients diagnosed with the definite MD(14 patients with unilateral and 5 patients withbilateral involvements).The“control group”consisted of 29 non-symptomatic ears belonging to patients diagnosed with unilateral sudden sensory-neural hearing loss or unilateral schwannoma.All the patients underwent 2 sessions of temporal bone MRI using the same 3T system:an unenhanced axial T1,T2,and 3D-FLAIR MRI,an intravenous gadoliniumenhanced axial T1 fat-sat,and 4 h after the injection,an axial 3D-T2 cube and 3D-FLAIR session.VH,CH,VANV,and VIPE were assessed.Subsequently,the correlation between EH indices and PTA findings(in three frequency domains of low,middle,and high)were evaluated,and the predictive value of MRI was calculated.Results:VH was significantly correlated with the hearing threshold in the low,middle,and highfrequency domains.CH was also correlated with the hearing threshold in the low and middle domains.Contrarily,VIPE was not associated with hearing thresholds,and VANV was only correlated with the hearing threshold in low frequencies.Conclusion:The grade of VH,CH,and VANV were significantly correlated with the hearing thresholds in PTA.展开更多
An efficient calibration algorithm for an ambulatory audiometric test system is proposed. This system utilizes a personal digital assistant (PDA) device to generate the correct sound pressure level (SPL) from an audio...An efficient calibration algorithm for an ambulatory audiometric test system is proposed. This system utilizes a personal digital assistant (PDA) device to generate the correct sound pressure level (SPL) from an audiometric transducer such as an earphone. The calibrated sound intensities for an audio-logical examination can be obtained in terms of the sound pressure levels of pure-tonal sinusoidal signals in eight-banded frequency ranges (250, 500, 1 000, 2 000, 3 000, 4 000, 6 000 and 8 000 Hz), and with mapping of the input sound pressure levels by the weight coefficients that are tuned by the delta learning rule. With this scheme, the sound intensities, which evoke eight-banded sound pressure levels by 5 dB steps from a minimum of 25 dB to a maximum of 80 dB, can be generated without volume displacement. Consequently, these sound intensities can be utilized to accurately determine the hearing threshold of a subject in the ambulatory audiometric testing environment.展开更多
仿真耳是听力计量的主要仪器之一,为满足听力计在8~16 k Hz高频范围内的计量需求,须对仿真耳进行高频校准。通过适配器的使用,解决了仿真耳高频校准中存在的测量结果不稳定的问题。同时,针对仿真耳中传声器声压灵敏度级和仿真耳声耦合...仿真耳是听力计量的主要仪器之一,为满足听力计在8~16 k Hz高频范围内的计量需求,须对仿真耳进行高频校准。通过适配器的使用,解决了仿真耳高频校准中存在的测量结果不稳定的问题。同时,针对仿真耳中传声器声压灵敏度级和仿真耳声耦合腔声学特性这两项主要技术指标,建立了8~16 k Hz频率范围内的自动测量系统,对其进行测量。测量结果表明声压灵敏度级的标准偏差小于0.2 d B,表征耦合腔声学特性的频响测量标准偏差小于0.3 d B。展开更多
目的综合比较感音神经性耳聋患者多频稳态听觉诱发电位(auditory steady-state response,ASSR)听域与纯音听域测试(pure tone audiometer,PTA)的差距,分析两种听域评估方法的相关性及其规律。方法比较126例中的198耳感音神经性耳聋的ASS...目的综合比较感音神经性耳聋患者多频稳态听觉诱发电位(auditory steady-state response,ASSR)听域与纯音听域测试(pure tone audiometer,PTA)的差距,分析两种听域评估方法的相关性及其规律。方法比较126例中的198耳感音神经性耳聋的ASSR听域图与PTA的听域图。结果中重度、重度听力损失情况下,从1 k Hz到4 k Hz声刺激时,ASSR听域与PTA听域比较接近,差异无统计学意义(P>0.05)。除外4 k Hz声刺激时,轻度耳聋患者的ASSR听域显著高于PTA听域(P<0.05)。而在0.5 k Hz声刺激时,只有重度听力损失的ASSR听域与PTA听域接近(P>0.05)。结论应用ASSR评估实际听域时应结合临床听力损失程度及声刺激频率。展开更多
文摘Purpose:To investigate the correlation between vestibular hydrops(VH),cochlearhydrops(CH),vestibular aqueduct non-visibility(VANV),and visually increased perilymphatic enhancement(VIPE)with the findings of pure-tone audiometry(PTA)in Meniere’s disease(MD)patients.Methods:In this cross-sectional study,53 ears belonging to 48 patients were divided into two groups and evaluated.In group“MD patients,”there were 24 ears of 19 patients diagnosed with the definite MD(14 patients with unilateral and 5 patients withbilateral involvements).The“control group”consisted of 29 non-symptomatic ears belonging to patients diagnosed with unilateral sudden sensory-neural hearing loss or unilateral schwannoma.All the patients underwent 2 sessions of temporal bone MRI using the same 3T system:an unenhanced axial T1,T2,and 3D-FLAIR MRI,an intravenous gadoliniumenhanced axial T1 fat-sat,and 4 h after the injection,an axial 3D-T2 cube and 3D-FLAIR session.VH,CH,VANV,and VIPE were assessed.Subsequently,the correlation between EH indices and PTA findings(in three frequency domains of low,middle,and high)were evaluated,and the predictive value of MRI was calculated.Results:VH was significantly correlated with the hearing threshold in the low,middle,and highfrequency domains.CH was also correlated with the hearing threshold in the low and middle domains.Contrarily,VIPE was not associated with hearing thresholds,and VANV was only correlated with the hearing threshold in low frequencies.Conclusion:The grade of VH,CH,and VANV were significantly correlated with the hearing thresholds in PTA.
基金supported by the grant of the Korean Ministry of Education, Science and Technology (The Regional Core Research Program/Chungbuk BIT Research-Oriented University Consortium)
文摘An efficient calibration algorithm for an ambulatory audiometric test system is proposed. This system utilizes a personal digital assistant (PDA) device to generate the correct sound pressure level (SPL) from an audiometric transducer such as an earphone. The calibrated sound intensities for an audio-logical examination can be obtained in terms of the sound pressure levels of pure-tonal sinusoidal signals in eight-banded frequency ranges (250, 500, 1 000, 2 000, 3 000, 4 000, 6 000 and 8 000 Hz), and with mapping of the input sound pressure levels by the weight coefficients that are tuned by the delta learning rule. With this scheme, the sound intensities, which evoke eight-banded sound pressure levels by 5 dB steps from a minimum of 25 dB to a maximum of 80 dB, can be generated without volume displacement. Consequently, these sound intensities can be utilized to accurately determine the hearing threshold of a subject in the ambulatory audiometric testing environment.
文摘仿真耳是听力计量的主要仪器之一,为满足听力计在8~16 k Hz高频范围内的计量需求,须对仿真耳进行高频校准。通过适配器的使用,解决了仿真耳高频校准中存在的测量结果不稳定的问题。同时,针对仿真耳中传声器声压灵敏度级和仿真耳声耦合腔声学特性这两项主要技术指标,建立了8~16 k Hz频率范围内的自动测量系统,对其进行测量。测量结果表明声压灵敏度级的标准偏差小于0.2 d B,表征耦合腔声学特性的频响测量标准偏差小于0.3 d B。
文摘目的综合比较感音神经性耳聋患者多频稳态听觉诱发电位(auditory steady-state response,ASSR)听域与纯音听域测试(pure tone audiometer,PTA)的差距,分析两种听域评估方法的相关性及其规律。方法比较126例中的198耳感音神经性耳聋的ASSR听域图与PTA的听域图。结果中重度、重度听力损失情况下,从1 k Hz到4 k Hz声刺激时,ASSR听域与PTA听域比较接近,差异无统计学意义(P>0.05)。除外4 k Hz声刺激时,轻度耳聋患者的ASSR听域显著高于PTA听域(P<0.05)。而在0.5 k Hz声刺激时,只有重度听力损失的ASSR听域与PTA听域接近(P>0.05)。结论应用ASSR评估实际听域时应结合临床听力损失程度及声刺激频率。