As a key part of the pyrotechnic gas generator,the filter not only removes the particulate matter but also cools the hot gas to a safe level.This paper aims to improve the understanding of the basic heat and flow phen...As a key part of the pyrotechnic gas generator,the filter not only removes the particulate matter but also cools the hot gas to a safe level.This paper aims to improve the understanding of the basic heat and flow phenomenon in the gas generator.The pyrotechnic gas generator is modelling by a simplified filter structure with fiber arrays.A finite-volume model of the heat and fluid flow is proposed to simulate the detailed multi-dimensional flow and energy conversion behaviors.Several verification results are in good agreement with data in different references.Simulation results demonstrate that the filter can not only absorb heat from the gas but also cause the high intensity enhancement of the heat transfer.The performance difference between inline and staggered arrays is also discussed.The findings of the study put a further prediction tool for the understanding and design of the filter system with fibers.展开更多
基金This work is supported by the National Natural Science Foundation of China(Grant No.11972194)the Fundamental Research Funds for the Central Universities,No.30918011323China Postdoctoral Science Foundation funded project(Grant No.2015M581797).
文摘As a key part of the pyrotechnic gas generator,the filter not only removes the particulate matter but also cools the hot gas to a safe level.This paper aims to improve the understanding of the basic heat and flow phenomenon in the gas generator.The pyrotechnic gas generator is modelling by a simplified filter structure with fiber arrays.A finite-volume model of the heat and fluid flow is proposed to simulate the detailed multi-dimensional flow and energy conversion behaviors.Several verification results are in good agreement with data in different references.Simulation results demonstrate that the filter can not only absorb heat from the gas but also cause the high intensity enhancement of the heat transfer.The performance difference between inline and staggered arrays is also discussed.The findings of the study put a further prediction tool for the understanding and design of the filter system with fibers.