Objectives: There is a high rate of sudden death in epilepsy patients, part of which is sudden cardiac death. By investigating ECG T wave alternans and Q-T dispersion changes of epilepsy patients, we may predict the p...Objectives: There is a high rate of sudden death in epilepsy patients, part of which is sudden cardiac death. By investigating ECG T wave alternans and Q-T dispersion changes of epilepsy patients, we may predict the possibility of the occurrence of sudden death and provide basis for clinical prevention. Methods: Selecting 587 cases of epilepsy patients as the study group, 672 same period cases of healthy persons as the control group;Analyzing the effect of epilepsy on ECG T wave alternans and Q-T dispersion with the standard 12 lead ECG. Results: The study group had a significantly prolonged Q-T dispersion and an increased incidence of T wave alternans than that of the control group;Compared with other seizure types, tonic clonic seizure and absence seizure had a significantly prolonged Q-T dispersion and an increased occurrence rate of T wave alternans. Conclusions: Epilepsy patients ECG T wave alternans and Q-T dispersion has higher abnormal rate, and are prone to sudden cardiac death;Routine ECG(RECG) T wave alternans and Q-T dispersion changes can provide guidance for clinical prevention of sudden unexpected death in epilepsy (SUDEP).展开更多
Repolarization heterogeneity(RH)is an intrinsic property of ventricular myocardium and the reason for T-wave formation on electrocardiogram(ECG).Exceeding the physiologically based RH level is associated with appearan...Repolarization heterogeneity(RH)is an intrinsic property of ventricular myocardium and the reason for T-wave formation on electrocardiogram(ECG).Exceeding the physiologically based RH level is associated with appearance of life-threatening ventricular arrhythmias and sudden cardiac death.In this regard,an accurate and comprehensive evaluation of the degree of RH parameters is of importance for assessment of heart state and arrhythmic risk.This review is devoted to comprehensive consideration of RH phenomena in terms of electrophysiological processes underlying RH,cardiac electric field formation during ventricular repolarization,as well as clinical significance of RH and its reflection on ECG parameters.The formation of transmural,apicobasal,left-toright and anterior-posterior gradients of action potential durations and end of repolarization times resulting from the heterogenous distribution of repolarizing ion currents and action potential morphology throughout the heart ventricles,and the different sensitivity of myocardial cells in different ventricular regions to the action of pharmacological agents,temperature,frequency of stimulation,etc.,are being discussed.The review is focused on the fact that RH has different aspects–temporal and spatial,global and local;ECG reflection of various RH aspects and their clinical significance are being discussed.Strategies for comprehensive assessment of ventricular RH using different ECG indices reflecting various RH aspects are presented.展开更多
As part of a research program, an extensive study on the dispersion characteristics of eight different7.62 ? 51 mm ammunition types was conducted. The paper presents the main steps in the experimental and analytical p...As part of a research program, an extensive study on the dispersion characteristics of eight different7.62 ? 51 mm ammunition types was conducted. The paper presents the main steps in the experimental and analytical process carried out to evaluate, namely to measure and compare, the dispersion characteristics of the ammunitions; namely,(1) identify the number of rounds to fire in the trials,(2) establish a test plan and the setup for the precision trials,(3) fire the rounds, following an established protocol for the experiments,(4) collect the impact points, and measure the performance through statistical measures,(5) perform a statistical analysis of dispersion applied to the results obtained in the trials, and(6)conclude on the ammunition characteristics. In particular, the paper proposes a statistical method to evaluate the precision of ammunitions fired with precision(Mann) barrels. The practical method relies on comparison of confidence intervals and hypothesis testing on the standard deviation of samples,namely the impact points. An algorithm is proposed to compare the variances of two or more populations of ammunitions.展开更多
Objective To investigate the elfects of some class Ⅰ antiarrhythmic agents on QT dispersion and compared with those of amiodarone. Methods Group I was composed of 30 cases, they were all treated with class Ⅰ agents....Objective To investigate the elfects of some class Ⅰ antiarrhythmic agents on QT dispersion and compared with those of amiodarone. Methods Group I was composed of 30 cases, they were all treated with class Ⅰ agents. The drugs used include: mexiletine (8 cases), moricizine (9), propafenone (12) and apridine (1). GrouP Ⅱ was composed of other 30 patients, and were all treated with amiodarone. The ddlerences of QT intervals between ECG leads (QTd and QTcd) were measured belore and aler medication. Results Before medication, the QTmax and QTcmax in group Ⅱ were signilicantly longer than those of group Ⅰ, resulting in greater QTd and QTcd in grouP Ⅱ (QTd:66± 14ms vs 31± 16ms, P<0.01; QTcd:71±36ms vs 44± 18ms, P<0.01). Alter medication, QTmax and QTcmax of group Ⅰ were prolonged, leading to the lengthening of QTd (from 31±16ms to 45±17ms, P<0.01) and QTcd (from 44± 18 ms to 58± 21ms, P<0.05), indicating the increase of inhomogeneity of myocardial repolarization after the treatment of class Ⅰ agents. Alter amiodarone treatment, QTmin and QTmax in grouP Ⅱ were both prolonged, with a greater amplitude of QTmin prolongation, resulting in decreased QTd and QTcd in group Ⅱ (QTd /rom 66± 14ms to 36±22ms, P<0.01, QTcd from 71±36ms to 45±27ms, P<0.01). The signifcant dofference of QTd and QTcd between two groups disappeared aler medication. Conclusion The results of the present study may relect the opposite effects of amiodarone and these class Ⅰ agents on myocardial repolarization.展开更多
文摘Objectives: There is a high rate of sudden death in epilepsy patients, part of which is sudden cardiac death. By investigating ECG T wave alternans and Q-T dispersion changes of epilepsy patients, we may predict the possibility of the occurrence of sudden death and provide basis for clinical prevention. Methods: Selecting 587 cases of epilepsy patients as the study group, 672 same period cases of healthy persons as the control group;Analyzing the effect of epilepsy on ECG T wave alternans and Q-T dispersion with the standard 12 lead ECG. Results: The study group had a significantly prolonged Q-T dispersion and an increased incidence of T wave alternans than that of the control group;Compared with other seizure types, tonic clonic seizure and absence seizure had a significantly prolonged Q-T dispersion and an increased occurrence rate of T wave alternans. Conclusions: Epilepsy patients ECG T wave alternans and Q-T dispersion has higher abnormal rate, and are prone to sudden cardiac death;Routine ECG(RECG) T wave alternans and Q-T dispersion changes can provide guidance for clinical prevention of sudden unexpected death in epilepsy (SUDEP).
文摘Repolarization heterogeneity(RH)is an intrinsic property of ventricular myocardium and the reason for T-wave formation on electrocardiogram(ECG).Exceeding the physiologically based RH level is associated with appearance of life-threatening ventricular arrhythmias and sudden cardiac death.In this regard,an accurate and comprehensive evaluation of the degree of RH parameters is of importance for assessment of heart state and arrhythmic risk.This review is devoted to comprehensive consideration of RH phenomena in terms of electrophysiological processes underlying RH,cardiac electric field formation during ventricular repolarization,as well as clinical significance of RH and its reflection on ECG parameters.The formation of transmural,apicobasal,left-toright and anterior-posterior gradients of action potential durations and end of repolarization times resulting from the heterogenous distribution of repolarizing ion currents and action potential morphology throughout the heart ventricles,and the different sensitivity of myocardial cells in different ventricular regions to the action of pharmacological agents,temperature,frequency of stimulation,etc.,are being discussed.The review is focused on the fact that RH has different aspects–temporal and spatial,global and local;ECG reflection of various RH aspects and their clinical significance are being discussed.Strategies for comprehensive assessment of ventricular RH using different ECG indices reflecting various RH aspects are presented.
文摘As part of a research program, an extensive study on the dispersion characteristics of eight different7.62 ? 51 mm ammunition types was conducted. The paper presents the main steps in the experimental and analytical process carried out to evaluate, namely to measure and compare, the dispersion characteristics of the ammunitions; namely,(1) identify the number of rounds to fire in the trials,(2) establish a test plan and the setup for the precision trials,(3) fire the rounds, following an established protocol for the experiments,(4) collect the impact points, and measure the performance through statistical measures,(5) perform a statistical analysis of dispersion applied to the results obtained in the trials, and(6)conclude on the ammunition characteristics. In particular, the paper proposes a statistical method to evaluate the precision of ammunitions fired with precision(Mann) barrels. The practical method relies on comparison of confidence intervals and hypothesis testing on the standard deviation of samples,namely the impact points. An algorithm is proposed to compare the variances of two or more populations of ammunitions.
文摘Objective To investigate the elfects of some class Ⅰ antiarrhythmic agents on QT dispersion and compared with those of amiodarone. Methods Group I was composed of 30 cases, they were all treated with class Ⅰ agents. The drugs used include: mexiletine (8 cases), moricizine (9), propafenone (12) and apridine (1). GrouP Ⅱ was composed of other 30 patients, and were all treated with amiodarone. The ddlerences of QT intervals between ECG leads (QTd and QTcd) were measured belore and aler medication. Results Before medication, the QTmax and QTcmax in group Ⅱ were signilicantly longer than those of group Ⅰ, resulting in greater QTd and QTcd in grouP Ⅱ (QTd:66± 14ms vs 31± 16ms, P<0.01; QTcd:71±36ms vs 44± 18ms, P<0.01). Alter medication, QTmax and QTcmax of group Ⅰ were prolonged, leading to the lengthening of QTd (from 31±16ms to 45±17ms, P<0.01) and QTcd (from 44± 18 ms to 58± 21ms, P<0.05), indicating the increase of inhomogeneity of myocardial repolarization after the treatment of class Ⅰ agents. Alter amiodarone treatment, QTmin and QTmax in grouP Ⅱ were both prolonged, with a greater amplitude of QTmin prolongation, resulting in decreased QTd and QTcd in group Ⅱ (QTd /rom 66± 14ms to 36±22ms, P<0.01, QTcd from 71±36ms to 45±27ms, P<0.01). The signifcant dofference of QTd and QTcd between two groups disappeared aler medication. Conclusion The results of the present study may relect the opposite effects of amiodarone and these class Ⅰ agents on myocardial repolarization.