This study developed a method on detecting methyl viologen(paraquat)using a CdTe-paper-based visual sensor.The CdTe Qdots were immobilized on the paper using glycerin.The volume percentages of CdTe in glycerin were op...This study developed a method on detecting methyl viologen(paraquat)using a CdTe-paper-based visual sensor.The CdTe Qdots were immobilized on the paper using glycerin.The volume percentages of CdTe in glycerin were optimized to be 50%.The sensing principle is that the methyl viologen quenches the fluorescence intensity of CdTe Qdots in a concentration dependent manner.The sensor is linearly response to the logarithm concentration of the methyl viologen in the range from 0.39μmol/L to 3.89 mmol/L with a detection limit of 0.16μmol/L and the corre-lation coefficient R^(2) of 0.99.Three parallel experiments at the methyl viologen concentration of 38.89μmol/L give a relative error of 2.45%,which indicates a good reproducibility.The sensor is not disturbed by other pestisides in-cluding omethoate,anilofos,machete and glyphosate isopropylamine salt.The advantages of this sensor are dis-posable,stable,convenient,and easy to operate.展开更多
基金supported by the National Natural Science Foundation of China(Nos.21273059,21003032)the State Key Laboratory of Urban Water Resource and Environment(Harbin Institute of Tech-nology)(No.2014DX09)+1 种基金the Fundamental Research Funds for the Central Universities(No.HIT.KISTP.201407)Harbin Science and Technology Research Council(No.2014RFXXJ063).
文摘This study developed a method on detecting methyl viologen(paraquat)using a CdTe-paper-based visual sensor.The CdTe Qdots were immobilized on the paper using glycerin.The volume percentages of CdTe in glycerin were optimized to be 50%.The sensing principle is that the methyl viologen quenches the fluorescence intensity of CdTe Qdots in a concentration dependent manner.The sensor is linearly response to the logarithm concentration of the methyl viologen in the range from 0.39μmol/L to 3.89 mmol/L with a detection limit of 0.16μmol/L and the corre-lation coefficient R^(2) of 0.99.Three parallel experiments at the methyl viologen concentration of 38.89μmol/L give a relative error of 2.45%,which indicates a good reproducibility.The sensor is not disturbed by other pestisides in-cluding omethoate,anilofos,machete and glyphosate isopropylamine salt.The advantages of this sensor are dis-posable,stable,convenient,and easy to operate.