In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of r...In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of radio frequency(RF) front end and high speed data acquisition board.The beam position resolution in the CBPM signal processing system is superior to 1μm.Two signal processing algorithms,fast Fourier transform(FFT) and digital down converter(DDC),are evaluated offline using MATLAB platform,and both can be used to achieve,the CW input signal,position resolutions of 0.31μm and 0.10μm at -16 dBm.The DDC algorithm for its good compatibility is downloaded into the FPGA to realize online measurement,reaching the position resolution of 0.49μm due to truncation error.The whole system works well and the performance meets design target.展开更多
Purpose Hundreds of digital beam position monitor processors(DBPM)are required to be produced during the construction of projects such as High Energy Photon Source(HEPS)and the upgrade project of the Beijing Electron ...Purpose Hundreds of digital beam position monitor processors(DBPM)are required to be produced during the construction of projects such as High Energy Photon Source(HEPS)and the upgrade project of the Beijing Electron Positron Collider(BEPCII),which brings great challenges to the test work.In order to achieve accurate,fast,and complete mass production tests of DBPMs,an automatic test system(ATS)has been developed in this article.Methods According to the test items of DBPM,the standardized testing softwareflow is designed based on virtual instru-ment program control technology and experimental physics and industrial control system(EPICS),which realize automatic adjustment of test parameters and automatic acquisition of test result data.Results and conclusions The ATS can realize one-button testing of channel coefficients,channel linearity,attenuator linearity,beam current dependence(BCD)and sampling signal-to-noise ratio(SNR),and generate test reports.The total test time is less than 3 minutes,which is significantly more efficient compared to manual testing.More than 90 BEPCII DBPMs has been tested by this ATS in the lab.The test results proved that such a system could automatically recognize defective products and satisfy the requirements of mass testing.展开更多
基金Supported by National Natural Science Foundaion of China(No.11075198)
文摘In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of radio frequency(RF) front end and high speed data acquisition board.The beam position resolution in the CBPM signal processing system is superior to 1μm.Two signal processing algorithms,fast Fourier transform(FFT) and digital down converter(DDC),are evaluated offline using MATLAB platform,and both can be used to achieve,the CW input signal,position resolutions of 0.31μm and 0.10μm at -16 dBm.The DDC algorithm for its good compatibility is downloaded into the FPGA to realize online measurement,reaching the position resolution of 0.49μm due to truncation error.The whole system works well and the performance meets design target.
基金funded by the Foundation ofYouth Innovation Promotion Association,CAS(No.Y202005)the Major achievements cultivation project of major scientific and technological infrastructure,CAS(No.NE01G74Y2)the National Natural Science Foundation of China(No.11805221).
文摘Purpose Hundreds of digital beam position monitor processors(DBPM)are required to be produced during the construction of projects such as High Energy Photon Source(HEPS)and the upgrade project of the Beijing Electron Positron Collider(BEPCII),which brings great challenges to the test work.In order to achieve accurate,fast,and complete mass production tests of DBPMs,an automatic test system(ATS)has been developed in this article.Methods According to the test items of DBPM,the standardized testing softwareflow is designed based on virtual instru-ment program control technology and experimental physics and industrial control system(EPICS),which realize automatic adjustment of test parameters and automatic acquisition of test result data.Results and conclusions The ATS can realize one-button testing of channel coefficients,channel linearity,attenuator linearity,beam current dependence(BCD)and sampling signal-to-noise ratio(SNR),and generate test reports.The total test time is less than 3 minutes,which is significantly more efficient compared to manual testing.More than 90 BEPCII DBPMs has been tested by this ATS in the lab.The test results proved that such a system could automatically recognize defective products and satisfy the requirements of mass testing.