In this study, we have used a direct immunoassay where the simple binding between antigen and an antibody is detected. Immunoassays were performed in a drop system, monitoring the frequency decrease of the quartz-crys...In this study, we have used a direct immunoassay where the simple binding between antigen and an antibody is detected. Immunoassays were performed in a drop system, monitoring the frequency decrease of the quartz-crystal microbalance device because of mass increasing during immunoreaction. The QCM sensor was coated on both sides by gold electrodes, only one side of the crystal (liquid side) was in contact with the solution;the other side (contact side) was always dry. We tested a piezoelectric immunosensor for aflatoxin B1 (AFLA-B1) mycotoxin detection through the immo- bilization of DSP-anti-AFLAB1 antibody (AFLA-B1-Ab anti AFLAB1) on gold-coated quartz crystals (AT-cut/5 MHz). The DSP (3,3’-Dithiodipropionic-acid-di-N-hydroxysuccinimide ester) was used for the covalent attachment of the proteins. The piezoelectric crystal electrodes were pretreated by DSP for 15 min, rinsed with water and dried in a gentle flow of nitrogen gas. Then the DSP-coated crystals were installed in a sample holder and exposed to the anti-AFLAB1 antibody and to the AFLA-BI. Frequency and resistance shifts (Δf and ΔR) were measured simultaneously. Δf versus AFLA-BI concentrations in the range of 0.5 - 10 ppb exhibited a perfect linear correlation with a coefficient of above 0.998.展开更多
Pd was electrochemically deposited on gold-coated quartz crystals at nanogram-level. The coulombic efficiency and initial nucleation and growth mechanism of potentiostatic Pd deposition were investigated via in situ e...Pd was electrochemically deposited on gold-coated quartz crystals at nanogram-level. The coulombic efficiency and initial nucleation and growth mechanism of potentiostatic Pd deposition were investigated via in situ electrochemical quartz crystal microbalance(EQCM). The coulombic efficieneies are 84%, 93% and 95% for Pd deposition at 0.3, 0.2 and 0.1 V(vs. SCE), respectively. The results of chronoamperometric measurements show that the Pd deposition proceeded by an instantaneous nucleation(at 0.3 V) or progressive nucleation(at 0.2 and 0.1 V) in a three-dimensional(3D) growth mode. The catalytic activity of Pd-based electrocatalyst for ethanol oxidation was characterized in an alkaline solution. It was found that the highest mass activity for ethanol oxidation on Pd-based electrocatalyst is 1.8× 10^4 A/(g Pd) deposited at 0.3 V for 5 s.展开更多
The gravimetric analysis of electrodeposited nickel is demonstrated using electrochemical quartz crystal microbalance (EQCM) where the nickel coatings come from a solution of the metal chloride salt separately in eith...The gravimetric analysis of electrodeposited nickel is demonstrated using electrochemical quartz crystal microbalance (EQCM) where the nickel coatings come from a solution of the metal chloride salt separately in either a1choline chloride: 2 ethylene glycol (ethaline) or 1 choline chloride: 2 urea (reline) based ionic liquid. The possibility of adapting the Quartz Crystal Microbalance EQCM (which measures the mass attached to the electrode) to probe kinetics of electrochemically-driven solid state phase transformations has been explored in a Ni electrodeposition in absence and presence of complexing agents ethylene diamine en and acetylacetonate acac from both electrolytes ethaline and reline. The study shows that the current efficiency and the rate of deposition of nickel coatings obtained from ethaline and reline baths in absence of brighteners en and acac are different, and the addition of en and acac to both ionic liquid solutions results in a significant decrease current. And the associated growth rate will also be decreased, suggesting that the en acac stops the formation and growth of Ni nuclei. This suggests that the mechanism of growth is changed.展开更多
We have investigated the interactions between phospholipid monolayers and volatile anest-hatics. Two monolayers (dihexadecyl phosphate (DHP) and dipalmitoyl phosphatidyl choline (DPPC) and two anesthetics (halothane a...We have investigated the interactions between phospholipid monolayers and volatile anest-hatics. Two monolayers (dihexadecyl phosphate (DHP) and dipalmitoyl phosphatidyl choline (DPPC) and two anesthetics (halothane and enflurane) were used to observe these interac-tions using a highly sensitive quartz crystal microbalance (HS-QCM). The concentration of each anesthetic in aqueous solution was kept at 4 mM. The frequency of QCM showed no change when halothane was added to the DHP monolayer, however, it responded and de-creased when interaction occurred with DPPC monolayer. In case of enflurane addition the frequency decreased in both the monolayers of DHP and DPPC. The frequency change followed the following order of monolayer-anesthetic interactions: DHP-halothane <DPPC-halothane <DHP-enflurane <DPPC-enflurane. These re-sults showed that the response of anesthetics to the monolayers i.e. the physisorption not only depends on the anesthetic structure, the type of anesthetic hydrate formed, but also the hydrophilic polar group structure of the monolayer or the monolayer/water interface had an important role in physisorption.展开更多
An electronic-nose is developed based on eight quartz-crystal-microbalance (QCM) gas sensors in a sensor box, and is used to detect Chinese liquors at room temperature. Each sensor is a highly-accurate and highly-sens...An electronic-nose is developed based on eight quartz-crystal-microbalance (QCM) gas sensors in a sensor box, and is used to detect Chinese liquors at room temperature. Each sensor is a highly-accurate and highly-sensitive oscillator that has experienced airflow disturbances under the condition of varying room temperatures due to unstable flow-induced forces on the sensors surfaces. The three-dimensional (3D) nature of the airflow inside the sensor box and the interactions of the airflow on the sensors surfaces at different temperatures are studied by computational fluid dynamics (CFD) tools. Higher simulation accuracy is achieved by optimizing meshes, meshing the computational domain using a fine unstructural tetrahedron mesh. An optimum temperature, 30 ℃, is obtained by analyzing the distributions of velocity streamlines and the static pressure, as well as the flow-induced forces over time, all of which may be used to improve the identification accuracy of the electronic-nose for achieving stable and repeatable signals by removing the influence of temperature.展开更多
The fast and accurate identification of nerve tracts is critical for successful nerve anastomosis. Taking advantage of differences in acetylcholinesterase content between the spinal ventral and dorsal roots, we develo...The fast and accurate identification of nerve tracts is critical for successful nerve anastomosis. Taking advantage of differences in acetylcholinesterase content between the spinal ventral and dorsal roots, we developed a novel quartz crystal microbalance method to distinguish between these nerves based on acetylcholinesterase antibody reactivity. The acetylcholinesterase antibody was immobilized on the electrode surface of a quartz crystal microbalance and reacted with the acetylcholinesterase in sample solution. The formed antigen and antibody complexes added to the mass of the electrode inducing a change in frequency of the electrode. The spinal ventral and dorsal roots were distinguished by the change in frequency. The ventral and dorsal roots were cut into 1 to 2-mm long segments and then soaked in 250 pL PBS. Acetylcholinesterase antibody was immobilized on the quartz crystal microbalance gold electrode surface. The results revealed that in 10 minutes, both spinal ventral and dorsal roots induced a frequency change; however, the frequency change induced by the ventral roots was notably higher than that induced by the dorsal roots. No change was induced by bovine serum albumin or PBS. These results clearly demonstrate that a quartz crystal microbalance sensor can be used as a rapid, highly sensitive and accurate detection tool for the quick identification of spinal nerve roots intraoperatively.展开更多
The electrochemical quartz crystal microbalance (EQCM) is used to investigate the characteristics of the thiolated self-assembled monolayer(SAM) on gold surface.A 5MHz QCM element serves as both the mass-sensitive sen...The electrochemical quartz crystal microbalance (EQCM) is used to investigate the characteristics of the thiolated self-assembled monolayer(SAM) on gold surface.A 5MHz QCM element serves as both the mass-sensitive sensor and the working electrode of the electrochemical system.The 6-mecapto-1-hexanol and and the 16-mer oligonucleotide with a mercaptohexyl group at the 5'-phosphate end are utilized to form the SAM on the gold electrode.The frequency response of the QCM during cyclic voltammetry (CV) scanning and cbronoamperometry are recorded together with the electrochemical current.The experimental results indicates that the frequency response is more sensitive to the surface coverage.Therefore,the response of the EQCM reveals more details of the SAM on gold electrode.It is especially useful for analysing the immobilization quality,such as probe orientation and coverage,of the SAM.展开更多
A dichlorosilane gas and a trichlorosilane gas in ambient hydrogen were evaluated to show their different gas flow motions in a slim vertical cold wall chemical vapor deposition reactor for the Minimal Fab system. Thi...A dichlorosilane gas and a trichlorosilane gas in ambient hydrogen were evaluated to show their different gas flow motions in a slim vertical cold wall chemical vapor deposition reactor for the Minimal Fab system. This evaluation was performed for improving and controlling the film qualities and the productivities, using two quartz crystal microbalances (QCM) installed at the </span><span style="font-family:Verdana;">inlet and exhaust of the chamber by taking into account that the QCM frequency corresponds to the real time changes in the gas properties.</span><span style="font-family:Verdana;"> Typically, the time period approaching from the inlet to the exhaust was shorter for the trichlorosilane gas than that for the dichlorosilane gas. The trichlorosilane gas was shown to move like plug flow, while the dichlorosilane gas seemed to be well mixed in the entire chamber.展开更多
The in situ electrochemical quartz crystal microbalance(EQCM) technique was used to investigate the ion transport of immobilized heteropolyanions at a self-assembled monolayer(SAM) modified gold electrode during e...The in situ electrochemical quartz crystal microbalance(EQCM) technique was used to investigate the ion transport of immobilized heteropolyanions at a self-assembled monolayer(SAM) modified gold electrode during electrochemical redox process.A mixed transfer method was presented to analyse the abnormal change of resonant frequency based on the simultaneous insertion/extraction of different ions.The results indicate that the migration of HSO4-anions was indispensable in the redox process of the heteropolyanions in a 1 mol/L H2SO4 solution and played a key role in the abnormal change of the resonant frequency.Such a change was attributed to different packing densities derived by means of differently immobilized methods.展开更多
The quartz crystal microbalance(QCM) is an important tool that can sense nanogram changes in mass. The hybrid temperature effect on a QCM resonator in aqueous solutions leads to unconvincing detection results. Contr...The quartz crystal microbalance(QCM) is an important tool that can sense nanogram changes in mass. The hybrid temperature effect on a QCM resonator in aqueous solutions leads to unconvincing detection results. Control of the temperature effect is one of the keys when using the QCM for high precision measurements. Based on the Sauerbrey's and Kanazawa's theories, we proposed a method for enhancing the accuracy of the QCM measurement, which takes into account not only the thermal variations of viscosity and density but also the thermal behavior of the QCM resonator. We presented an improved Sauerbrey equation that can be used to effectively compensate the drift of the QCM resonator. These results will play a significant role when applying the QCM at the room temperature.展开更多
A quartz crystal microbalance (QCM) is used to determine the phase equilibrium of paclitaxel-carbon dioxide system in the pressure range of 0-11 MPa and at temperatures of 35 °C,40 °C and 45 °C.The ex...A quartz crystal microbalance (QCM) is used to determine the phase equilibrium of paclitaxel-carbon dioxide system in the pressure range of 0-11 MPa and at temperatures of 35 °C,40 °C and 45 °C.The experimental results indicated that gaseous CO2 could be absorbed poorly into paclitaxel.The swelling of paclitaxel film in CO2 was observed before paclitaxel dissolved into supercritical carbon dioxide (ScCO2) with the increase of pressure.It was found that ScCO2 was not a good solvent for paclitaxel.The mole fraction of paclitaxel in ScCO2 was in the range of (4.5×10-9)-(7.8×10-9) under all our experimental conditions.Therefore,a much higher pressure than the CO2 supercritical point and/or a cosolvent must be used in any processes wherever paclitaxel dissolution in ScCO2 is required.展开更多
The effect of salt concentration on layer-by-layer deposition of poly(sodium 4-styrene sulfonate) (PSSS)/poly(vinylbenzyl trimethylammonium chloride) (PVTC) was investigated by use of quartz crystal microbalan...The effect of salt concentration on layer-by-layer deposition of poly(sodium 4-styrene sulfonate) (PSSS)/poly(vinylbenzyl trimethylammonium chloride) (PVTC) was investigated by use of quartz crystal microbalance with dissipation (QCM-D). The changes in frequency and dissipation demonstrate that the addition of NaC1 leads the thickness of PSSS/PVTC multilayer to increase. The deposition of PSSS/PVTC is dominated by surface charge overcompensation level at lower salt concentrations. However, it is mainly determined by the interpenetration of polyelectrolytes at a higher salt concentration, as reflected in the oscillation of dissipation change.展开更多
Nanoparticles are playing an increasingly important role in the development of biosensors. The sensitivity and performance of biosensors are being improved by using Nanoparticles for their construction. The use of the...Nanoparticles are playing an increasingly important role in the development of biosensors. The sensitivity and performance of biosensors are being improved by using Nanoparticles for their construction. The use of these Nanoparticles has allowed the introduction of many new signal transduction technologies in biosensors. In this report, a comprehensive review of application of nanoparticles in Quartz Crystal Microbalance biosensors is presented. The main advantages of QCM in sensing fields include high sensitivity, high stability, fast response and low cost. In addition, it provides label-free detection capability for bio-sensing applications. Firstly, basic QCM’s design and characterization are described. Next, QCM biosensors based on modification of quartz substrate structure and their applications are digested. Nanoparticles and their utilizationin analysis are then illustrated. These include Nanoparticles in bio applications that cover Nanoparticles in Quartz Crystal Microbalance biosensors.展开更多
文摘In this study, we have used a direct immunoassay where the simple binding between antigen and an antibody is detected. Immunoassays were performed in a drop system, monitoring the frequency decrease of the quartz-crystal microbalance device because of mass increasing during immunoreaction. The QCM sensor was coated on both sides by gold electrodes, only one side of the crystal (liquid side) was in contact with the solution;the other side (contact side) was always dry. We tested a piezoelectric immunosensor for aflatoxin B1 (AFLA-B1) mycotoxin detection through the immo- bilization of DSP-anti-AFLAB1 antibody (AFLA-B1-Ab anti AFLAB1) on gold-coated quartz crystals (AT-cut/5 MHz). The DSP (3,3’-Dithiodipropionic-acid-di-N-hydroxysuccinimide ester) was used for the covalent attachment of the proteins. The piezoelectric crystal electrodes were pretreated by DSP for 15 min, rinsed with water and dried in a gentle flow of nitrogen gas. Then the DSP-coated crystals were installed in a sample holder and exposed to the anti-AFLAB1 antibody and to the AFLA-BI. Frequency and resistance shifts (Δf and ΔR) were measured simultaneously. Δf versus AFLA-BI concentrations in the range of 0.5 - 10 ppb exhibited a perfect linear correlation with a coefficient of above 0.998.
基金Supported by the Guangdong Science and Technology Key Projects, China(Nos.2007A010700001, 2007B090400032)Guangzhou Science and Technology Key Projects, China(Nos.2007Z1-D0051, SKT[2007]17-11) the Scientific Research Foundation for Young Teachers of the Sun Yat-Sen University, China(No.2006-31000-1131214)
文摘Pd was electrochemically deposited on gold-coated quartz crystals at nanogram-level. The coulombic efficiency and initial nucleation and growth mechanism of potentiostatic Pd deposition were investigated via in situ electrochemical quartz crystal microbalance(EQCM). The coulombic efficieneies are 84%, 93% and 95% for Pd deposition at 0.3, 0.2 and 0.1 V(vs. SCE), respectively. The results of chronoamperometric measurements show that the Pd deposition proceeded by an instantaneous nucleation(at 0.3 V) or progressive nucleation(at 0.2 and 0.1 V) in a three-dimensional(3D) growth mode. The catalytic activity of Pd-based electrocatalyst for ethanol oxidation was characterized in an alkaline solution. It was found that the highest mass activity for ethanol oxidation on Pd-based electrocatalyst is 1.8× 10^4 A/(g Pd) deposited at 0.3 V for 5 s.
文摘The gravimetric analysis of electrodeposited nickel is demonstrated using electrochemical quartz crystal microbalance (EQCM) where the nickel coatings come from a solution of the metal chloride salt separately in either a1choline chloride: 2 ethylene glycol (ethaline) or 1 choline chloride: 2 urea (reline) based ionic liquid. The possibility of adapting the Quartz Crystal Microbalance EQCM (which measures the mass attached to the electrode) to probe kinetics of electrochemically-driven solid state phase transformations has been explored in a Ni electrodeposition in absence and presence of complexing agents ethylene diamine en and acetylacetonate acac from both electrolytes ethaline and reline. The study shows that the current efficiency and the rate of deposition of nickel coatings obtained from ethaline and reline baths in absence of brighteners en and acac are different, and the addition of en and acac to both ionic liquid solutions results in a significant decrease current. And the associated growth rate will also be decreased, suggesting that the en acac stops the formation and growth of Ni nuclei. This suggests that the mechanism of growth is changed.
文摘We have investigated the interactions between phospholipid monolayers and volatile anest-hatics. Two monolayers (dihexadecyl phosphate (DHP) and dipalmitoyl phosphatidyl choline (DPPC) and two anesthetics (halothane and enflurane) were used to observe these interac-tions using a highly sensitive quartz crystal microbalance (HS-QCM). The concentration of each anesthetic in aqueous solution was kept at 4 mM. The frequency of QCM showed no change when halothane was added to the DHP monolayer, however, it responded and de-creased when interaction occurred with DPPC monolayer. In case of enflurane addition the frequency decreased in both the monolayers of DHP and DPPC. The frequency change followed the following order of monolayer-anesthetic interactions: DHP-halothane <DPPC-halothane <DHP-enflurane <DPPC-enflurane. These re-sults showed that the response of anesthetics to the monolayers i.e. the physisorption not only depends on the anesthetic structure, the type of anesthetic hydrate formed, but also the hydrophilic polar group structure of the monolayer or the monolayer/water interface had an important role in physisorption.
基金Project supported by the National Natural Science Foundation of China(Nos.61876059 and U1501251)
文摘An electronic-nose is developed based on eight quartz-crystal-microbalance (QCM) gas sensors in a sensor box, and is used to detect Chinese liquors at room temperature. Each sensor is a highly-accurate and highly-sensitive oscillator that has experienced airflow disturbances under the condition of varying room temperatures due to unstable flow-induced forces on the sensors surfaces. The three-dimensional (3D) nature of the airflow inside the sensor box and the interactions of the airflow on the sensors surfaces at different temperatures are studied by computational fluid dynamics (CFD) tools. Higher simulation accuracy is achieved by optimizing meshes, meshing the computational domain using a fine unstructural tetrahedron mesh. An optimum temperature, 30 ℃, is obtained by analyzing the distributions of velocity streamlines and the static pressure, as well as the flow-induced forces over time, all of which may be used to improve the identification accuracy of the electronic-nose for achieving stable and repeatable signals by removing the influence of temperature.
基金supported by the National Natural Science Foundation of China,No. 30973058,81171694Jiangsu Province Natural Science Foundation,No. BE2010743+2 种基金Jiangsu Graduate Student Innovation Project,No.CXZZ11_0721the Program for Development of Innovative Research Team in the First Affiliated Hospital of Nanjing Medical University,No. IRT-015a Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘The fast and accurate identification of nerve tracts is critical for successful nerve anastomosis. Taking advantage of differences in acetylcholinesterase content between the spinal ventral and dorsal roots, we developed a novel quartz crystal microbalance method to distinguish between these nerves based on acetylcholinesterase antibody reactivity. The acetylcholinesterase antibody was immobilized on the electrode surface of a quartz crystal microbalance and reacted with the acetylcholinesterase in sample solution. The formed antigen and antibody complexes added to the mass of the electrode inducing a change in frequency of the electrode. The spinal ventral and dorsal roots were distinguished by the change in frequency. The ventral and dorsal roots were cut into 1 to 2-mm long segments and then soaked in 250 pL PBS. Acetylcholinesterase antibody was immobilized on the quartz crystal microbalance gold electrode surface. The results revealed that in 10 minutes, both spinal ventral and dorsal roots induced a frequency change; however, the frequency change induced by the ventral roots was notably higher than that induced by the dorsal roots. No change was induced by bovine serum albumin or PBS. These results clearly demonstrate that a quartz crystal microbalance sensor can be used as a rapid, highly sensitive and accurate detection tool for the quick identification of spinal nerve roots intraoperatively.
文摘The electrochemical quartz crystal microbalance (EQCM) is used to investigate the characteristics of the thiolated self-assembled monolayer(SAM) on gold surface.A 5MHz QCM element serves as both the mass-sensitive sensor and the working electrode of the electrochemical system.The 6-mecapto-1-hexanol and and the 16-mer oligonucleotide with a mercaptohexyl group at the 5'-phosphate end are utilized to form the SAM on the gold electrode.The frequency response of the QCM during cyclic voltammetry (CV) scanning and cbronoamperometry are recorded together with the electrochemical current.The experimental results indicates that the frequency response is more sensitive to the surface coverage.Therefore,the response of the EQCM reveals more details of the SAM on gold electrode.It is especially useful for analysing the immobilization quality,such as probe orientation and coverage,of the SAM.
文摘A dichlorosilane gas and a trichlorosilane gas in ambient hydrogen were evaluated to show their different gas flow motions in a slim vertical cold wall chemical vapor deposition reactor for the Minimal Fab system. This evaluation was performed for improving and controlling the film qualities and the productivities, using two quartz crystal microbalances (QCM) installed at the </span><span style="font-family:Verdana;">inlet and exhaust of the chamber by taking into account that the QCM frequency corresponds to the real time changes in the gas properties.</span><span style="font-family:Verdana;"> Typically, the time period approaching from the inlet to the exhaust was shorter for the trichlorosilane gas than that for the dichlorosilane gas. The trichlorosilane gas was shown to move like plug flow, while the dichlorosilane gas seemed to be well mixed in the entire chamber.
基金Supported by the Science Foundation for Young Teachers of Northeast Normal University,China(No.20081001)
文摘The in situ electrochemical quartz crystal microbalance(EQCM) technique was used to investigate the ion transport of immobilized heteropolyanions at a self-assembled monolayer(SAM) modified gold electrode during electrochemical redox process.A mixed transfer method was presented to analyse the abnormal change of resonant frequency based on the simultaneous insertion/extraction of different ions.The results indicate that the migration of HSO4-anions was indispensable in the redox process of the heteropolyanions in a 1 mol/L H2SO4 solution and played a key role in the abnormal change of the resonant frequency.Such a change was attributed to different packing densities derived by means of differently immobilized methods.
基金supported by the National Natural Science Foundation of China(Grant No.61672094)
文摘The quartz crystal microbalance(QCM) is an important tool that can sense nanogram changes in mass. The hybrid temperature effect on a QCM resonator in aqueous solutions leads to unconvincing detection results. Control of the temperature effect is one of the keys when using the QCM for high precision measurements. Based on the Sauerbrey's and Kanazawa's theories, we proposed a method for enhancing the accuracy of the QCM measurement, which takes into account not only the thermal variations of viscosity and density but also the thermal behavior of the QCM resonator. We presented an improved Sauerbrey equation that can be used to effectively compensate the drift of the QCM resonator. These results will play a significant role when applying the QCM at the room temperature.
基金Supported by the Jiangsu High-tech Project(BG2006038)
文摘A quartz crystal microbalance (QCM) is used to determine the phase equilibrium of paclitaxel-carbon dioxide system in the pressure range of 0-11 MPa and at temperatures of 35 °C,40 °C and 45 °C.The experimental results indicated that gaseous CO2 could be absorbed poorly into paclitaxel.The swelling of paclitaxel film in CO2 was observed before paclitaxel dissolved into supercritical carbon dioxide (ScCO2) with the increase of pressure.It was found that ScCO2 was not a good solvent for paclitaxel.The mole fraction of paclitaxel in ScCO2 was in the range of (4.5×10-9)-(7.8×10-9) under all our experimental conditions.Therefore,a much higher pressure than the CO2 supercritical point and/or a cosolvent must be used in any processes wherever paclitaxel dissolution in ScCO2 is required.
基金This work was supported by the National Natural Science Foundation of China (No.20474060).
文摘The effect of salt concentration on layer-by-layer deposition of poly(sodium 4-styrene sulfonate) (PSSS)/poly(vinylbenzyl trimethylammonium chloride) (PVTC) was investigated by use of quartz crystal microbalance with dissipation (QCM-D). The changes in frequency and dissipation demonstrate that the addition of NaC1 leads the thickness of PSSS/PVTC multilayer to increase. The deposition of PSSS/PVTC is dominated by surface charge overcompensation level at lower salt concentrations. However, it is mainly determined by the interpenetration of polyelectrolytes at a higher salt concentration, as reflected in the oscillation of dissipation change.
文摘Nanoparticles are playing an increasingly important role in the development of biosensors. The sensitivity and performance of biosensors are being improved by using Nanoparticles for their construction. The use of these Nanoparticles has allowed the introduction of many new signal transduction technologies in biosensors. In this report, a comprehensive review of application of nanoparticles in Quartz Crystal Microbalance biosensors is presented. The main advantages of QCM in sensing fields include high sensitivity, high stability, fast response and low cost. In addition, it provides label-free detection capability for bio-sensing applications. Firstly, basic QCM’s design and characterization are described. Next, QCM biosensors based on modification of quartz substrate structure and their applications are digested. Nanoparticles and their utilizationin analysis are then illustrated. These include Nanoparticles in bio applications that cover Nanoparticles in Quartz Crystal Microbalance biosensors.