期刊文献+
共找到69篇文章
< 1 2 4 >
每页显示 20 50 100
Etching of quartz crystals in liquid phase environment:A review
1
作者 Yide Dong Yike Zhou +5 位作者 Haizhou Huang Bosong Zhang Xihan Li Kaiwen Chen Litao Sun Guangbin Dou 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2024年第2期87-109,共23页
Quartz crystals are the most widely used material in resonant sensors,owing to their excellent piezoelectric and mechanical properties.With the development of portable and wearable devices,higher processing efficiency... Quartz crystals are the most widely used material in resonant sensors,owing to their excellent piezoelectric and mechanical properties.With the development of portable and wearable devices,higher processing efficiency and geometrical precision are required.Wet etching has been proven to be the most efficient etching method for large-scale production of quartz devices,and many wet etching approaches have been developed over the years.However,until now,there has been no systematic review of quartz crystal etching in liquid phase environments.Therefore,this article provides a comprehensive review of the development of wet etching processes and the achievements of the latest research in thisfield,covering conventional wet etching,additive etching,laser-induced backside wet etching,electrochemical etching,and electrochemical discharge machining.For each technique,a brief overview of its characteristics is provided,associated problems are described,and possible solutions are discussed.This review should provide an essential reference and guidance for the future development of processing strategies for the manufacture of quartz crystal devices. 展开更多
关键词 quartz crystal Materials processing Wet etching MICROFABRICATION quartz MEMS
下载PDF
Adsorption of Microcystin onto Polymer Covered Gold Chips by Quartz Crystal Microbalance-Dissipation Detection
2
作者 郑斌 毕建洪 +2 位作者 董华泽 朱金苗 梁好均 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2014年第6期739-744,I0004,共7页
Different functional polystyrenes were synthesized and the adsorptions of microcystin-LR onto those resins were monitored by quartz crystal microbalance-dissipation. Both adsorption pH and surface properties had a con... Different functional polystyrenes were synthesized and the adsorptions of microcystin-LR onto those resins were monitored by quartz crystal microbalance-dissipation. Both adsorption pH and surface properties had a considerable effect on the adsorption amount, while adsorption temperature was less significant. Ammonium polystyrene would be a better candidate for microcystin-LR adsorption at neutral pH conditions. 展开更多
关键词 POLYSTYRENE quartz crystal microbalance-dissipation MICROCYSTIN-LR ADSORPTION
下载PDF
The Characteristics of the Shear-Vibrating Quartz Crystal Resonator 被引量:6
3
作者 Wenjie Tian Lingling Liu +1 位作者 Junling Lu Fuxue Zhang 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期627-629,共3页
<正>According to the piezoelectric equation and the vibration theory of the quartz crystal,the relations between the vibrating frequency and structural parameters under the thickness-shear-vibration of AT-cut qu... <正>According to the piezoelectric equation and the vibration theory of the quartz crystal,the relations between the vibrating frequency and structural parameters under the thickness-shear-vibration of AT-cut quartz crystal have been studied. The frequency conditions under which quartz crystal resonator formed stationary wave inside the electrode district and the transmission characteristics of wave outside the electrode district have also been discussed.A quartz crystal resonator was developed based on this analysis.The experiment showed that the force-sensing characteristics were independent of the fixation of the crystal edge.The detecting distinguish ability was up to 0.001°,and the short-term frequency stability was up to 1.38×10~ (-10)/min. 展开更多
关键词 quartz crystal shear-vibration stationary wave characteristic quartz resonator
下载PDF
Coupled vibrations and frequency shift of compound system consisting of quartz crystal resonator in thickness-shear motions and micro-beam array immersed in liquid 被引量:3
4
作者 Xuan XIE Lingcheng KONG +2 位作者 Yuxi WANG Jun ZHANG Yuantai HU 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2015年第2期225-232,共8页
The dynamic characteristics of a quartz crystal resonator(QCR) in thicknessshear modes(TSM) with the upper surface covered by an array of micro-beams immersed in liquid are studied. The liquid is assumed to be inv... The dynamic characteristics of a quartz crystal resonator(QCR) in thicknessshear modes(TSM) with the upper surface covered by an array of micro-beams immersed in liquid are studied. The liquid is assumed to be inviscid and incompressible for simplicity. Dynamic equations of the coupled system are established. The added mass effect of liquid on micro-beams is discussed in detail. Characteristics of frequency shift are clarified for different liquid depths. Modal analysis shows that a drag effect of liquid has resulted in the change of phase of interaction(surface shear force), thus changing the system resonant frequency. The obtained results are useful in resonator design and applications. 展开更多
关键词 quartz crystal resonator(QCR) MICRO-BEAM modal analysis frequency shift added mass of liquid
下载PDF
Vibration analysis of a new polymer quartz piezoelectric crystal sensor for detecting characteristic materials of volatility liquid 被引量:3
5
作者 谷宇 李强 +1 位作者 许保军 赵囍 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第1期448-453,共6页
We present a new polymer quartz piezoelectric crystal sensor that takes a quartz piezoelectric crystal as the basal material and a nanometer nonmetallic polymer thin film as the surface coating based on the principle ... We present a new polymer quartz piezoelectric crystal sensor that takes a quartz piezoelectric crystal as the basal material and a nanometer nonmetallic polymer thin film as the surface coating based on the principle of quartz crystal microbalance(QCM). The new sensor can be used to detect the characteristic materials of a volatile liquid. A mechanical model of the new sensor was built, whose structure was a thin circle plate composing of polytef/quartz piezoelectric/polytef. The mechanical model had a diameter of 8 mm and a thickness of 170 μm. The vibration state of the model was simulated by software ANSYS after the physical parameters and the boundary condition of the new sensor were set. According to the results of experiments, we set up a frequency range from 9.995850 MHz to 9.997225 MHz, 17 kinds of frequencies and modes of vibration were obtained within this range. We found a special frequency fspof 9.996358 MHz. When the resonant frequency of the new sensor's mechanical model reached the special frequency, a special phenomenon occurred. In this case, the amplitude of the center point O on the mechanical model reached the maximum value. At the same time, the minimum absolute difference between the simulated frequency based on the ANSYS software and the experimental measured stable frequency was reached. The research showed that the design of the new polymer quartz piezoelectric crystal sensor perfectly conforms to the principle of QCM. A special frequency value fspwas found and subsequently became one of the most important parameters in the new sensor design. 展开更多
关键词 quartz piezoelectric crystal sensor quartz crystal microbalance vibration analysis special res-onator frequency
下载PDF
High sensitive piezoelectric quartz crystal liquid density sensor 被引量:2
6
作者 Xue Cai Zhao Jun Guo Du +2 位作者 Rui Sheng Qi Kang Da Zhong Shen 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第9期1129-1132,共4页
We report for the first time a cleavage phenomenon in the resonant peak of a piezoelectric quartz crystal(PQC) in liquid phase.In the presence of a strong longitudinal wave effect,an additional resonant peak appears i... We report for the first time a cleavage phenomenon in the resonant peak of a piezoelectric quartz crystal(PQC) in liquid phase.In the presence of a strong longitudinal wave effect,an additional resonant peak appears in the conductance-frequency curve.With gradually increasing liquid density,the additional peak moves from low to high frequency region then disappears.The frequency of the additional resonant peak is sensitive to the change in liquid density.The frequency shift of the additional peak is linear with the liquid density in a given range.For a 5 MHz PQC with a reflection distance of 16 mm for longitudinal wave,the sensitivity to liquid density is 2.61×10^6 Hz g^-1 cm^3.The overlap between the primary resonant peak and the additional resonant peak causes a decrease in the intensity of the former and an increase in the intensity of the latter.In a combined impedance analysis method,the changes in surface mass loading,density and viscosity of the liquid were monitored simultaneously by a PQC sensor. 展开更多
关键词 Piezoelectric quartz crystal Density sensor Longitudinal wave Impedance analysis
下载PDF
Rapid identification of spinal ventral and dorsal roots using a quartz crystal microbalance 被引量:1
7
作者 Tao Sui Jun Que +5 位作者 Dechao Kong Hao Xie Daode Wang Kun Shi Xiaojian Cao Xiang Li 《Neural Regeneration Research》 SCIE CAS CSCD 2013年第8期686-692,共7页
The fast and accurate identification of nerve tracts is critical for successful nerve anastomosis. Taking advantage of differences in acetylcholinesterase content between the spinal ventral and dorsal roots, we develo... The fast and accurate identification of nerve tracts is critical for successful nerve anastomosis. Taking advantage of differences in acetylcholinesterase content between the spinal ventral and dorsal roots, we developed a novel quartz crystal microbalance method to distinguish between these nerves based on acetylcholinesterase antibody reactivity. The acetylcholinesterase antibody was immobilized on the electrode surface of a quartz crystal microbalance and reacted with the acetylcholinesterase in sample solution. The formed antigen and antibody complexes added to the mass of the electrode inducing a change in frequency of the electrode. The spinal ventral and dorsal roots were distinguished by the change in frequency. The ventral and dorsal roots were cut into 1 to 2-mm long segments and then soaked in 250 pL PBS. Acetylcholinesterase antibody was immobilized on the quartz crystal microbalance gold electrode surface. The results revealed that in 10 minutes, both spinal ventral and dorsal roots induced a frequency change; however, the frequency change induced by the ventral roots was notably higher than that induced by the dorsal roots. No change was induced by bovine serum albumin or PBS. These results clearly demonstrate that a quartz crystal microbalance sensor can be used as a rapid, highly sensitive and accurate detection tool for the quick identification of spinal nerve roots intraoperatively. 展开更多
关键词 neural regeneration peripheral nerve injury basic research quartz crystal microbalance biosensor spinal nerve nerve tract ACETYLCHOLINESTERASE antigen-antibody reaction identification ANASTOMOSIS nerve repair grants-supported paper NEUROREGENERATION
下载PDF
Alkaline treatment kinetics of calcium phosphate by piezoelectric quartz crystal impedance 被引量:1
8
作者 曾丽萍 何德良 +1 位作者 许超 罗胜联 《Journal of Central South University》 SCIE EI CAS 2009年第4期558-562,共5页
Calcium phosphate film was prepared by electrochemical deposition technology. Subsequently, the alkaline treatment process of calcium phosphate film in 0.1 mol/L NaOH solution was monitored on real time by the piezoel... Calcium phosphate film was prepared by electrochemical deposition technology. Subsequently, the alkaline treatment process of calcium phosphate film in 0.1 mol/L NaOH solution was monitored on real time by the piezoelectric quartz crystal impedance (PQCI) technique. The variations of morphology and composition for the alkaline treatment products were characterized by scanning electron microscopy (SEM), Fourier transform infrared (FT-IR) and X-ray diffraction (XRD), respectively. The dynamic variations of calcium phosphate can be characterized by the change of equivalent circuit parameters. The results show that the forming process of hydroxyapatite (HA) is composed of three stages: (1) acidic calcium phosphate dissolution; (2) phase transformation; and (3) HA formation. Furthermore, the correlative kinetic equations and parameters are obtained by fitting the static capacitance (C8)-time curves. 展开更多
关键词 HYDROXYAPATITE calcium phosphate piezoelectric quartz crystal impedance alkaline treatment KINETICS
下载PDF
Effect of strain-gradients of surface micro-beams on frequency-shift of a quartz crystal resonator under thickness-shear vibrations 被引量:1
9
作者 Ling-Cheng Kong Yuan-Tai Hu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2015年第5期647-652,共6页
With introduction of the first-order strain-gradient of surface micro-beams into the energy density function,we developed a two-dimensional dynamic model for a compound quartz crystal resonator(QCR) system,consistin... With introduction of the first-order strain-gradient of surface micro-beams into the energy density function,we developed a two-dimensional dynamic model for a compound quartz crystal resonator(QCR) system,consisting of a QCR and surface micro-beam arrays.The frequency shift that was induced by micro-beams with consideration of strain-gradients is discussed in detail and some useful results are obtained,which have important significance in resonator design and applications. 展开更多
关键词 Micro-beams Strain-gradient quartz crystal resonator Frequency shift
下载PDF
Characterization of Self-assembled Monolayers on Gold Electrode Using Electrochemical Quartz Crystal Microbalance 被引量:1
10
作者 Yonggui Dong 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期392-395,共4页
The electrochemical quartz crystal microbalance (EQCM) is used to investigate the characteristics of the thiolated self-assembled monolayer(SAM) on gold surface.A 5MHz QCM element serves as both the mass-sensitive sen... The electrochemical quartz crystal microbalance (EQCM) is used to investigate the characteristics of the thiolated self-assembled monolayer(SAM) on gold surface.A 5MHz QCM element serves as both the mass-sensitive sensor and the working electrode of the electrochemical system.The 6-mecapto-1-hexanol and and the 16-mer oligonucleotide with a mercaptohexyl group at the 5'-phosphate end are utilized to form the SAM on the gold electrode.The frequency response of the QCM during cyclic voltammetry (CV) scanning and cbronoamperometry are recorded together with the electrochemical current.The experimental results indicates that the frequency response is more sensitive to the surface coverage.Therefore,the response of the EQCM reveals more details of the SAM on gold electrode.It is especially useful for analysing the immobilization quality,such as probe orientation and coverage,of the SAM. 展开更多
关键词 quartz crystal microbalancc self-assembled monolayer cyclic voltammetry CHRONOAMPEROMETRY
下载PDF
In Situ Acquisition of Equivalent Circuit Parameters of Crystal Resonance during Copper Deposition and Dissolution in Acidic Solution by Electrochemical Quartz Crystal Impedance System 被引量:1
11
作者 Qing Ji XIE Xiao Lian SUN +3 位作者 Xiao Lan GU Hong Wei LIU You Yu ZHANG Shou Zhuo YAO(Chemical Research Institute. Hunan Normal University,Changsha 410081)(Chemistry Department,Hunan Normal University, Changsha 410081) 《Chinese Chemical Letters》 SCIE CAS CSCD 1999年第1期73-76,共4页
Electrochemical quartz crystal impedance system (EQCIS) which allows in situ dynamic quartz crystal impedance measurement in an electrochemical experiment was developed by combining an HP 4395A Network/Spectrum/Impeda... Electrochemical quartz crystal impedance system (EQCIS) which allows in situ dynamic quartz crystal impedance measurement in an electrochemical experiment was developed by combining an HP 4395A Network/Spectrum/Impedance analyzer with an EG&G M283 potentiostat. Equivalent circuit parameters of crystal resonance change significantly during electrodeposition and dissolution of copper in 0.1 mol/L H2SO4 aqueous solution in a cyclic potential sweep experiment, which is explained with an overall picture of mass loading, solution density and viscosity, etc.. 展开更多
关键词 in situ quartz crystal impedance measurement equivalent circuit parameters ELECTRODEPOSITION copper
下载PDF
Influence of surface micro-beams with large deflection on the resonance frequency of a quartz crystal resonator in thickness-shear mode vibrations 被引量:1
12
作者 Chi Luo Jiemin Xie Yuantai Hu 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2017年第2期72-75,共4页
We study the dynamic behavior of a quartz crystal resonator (QCR) in thickness-shear vibrations with the upper surface covered by an array of micro-beams (MBs) under large deflection. Through taking into account t... We study the dynamic behavior of a quartz crystal resonator (QCR) in thickness-shear vibrations with the upper surface covered by an array of micro-beams (MBs) under large deflection. Through taking into account the continuous conditions of shear force and bending moment at the interface of MBs/resonator, dependences of frequency shift of the compound QCR system versus material parameter and geometrical parameter are illustrated in detail for nonlinear and linear vibrations. It is found that the frequency shift produces a little right (left) translation for increasing elastic modulus (length/radius ratio) of MBs. Moreover, the frequency right (left) translation distance caused by nonlinear deformation becomes more serious in the second-order mode than in the first-order one, 展开更多
关键词 quartz crystal resonator Nonlinear deformation Micro-beams Frequency shift
下载PDF
Quartz Crystal Microbalances for Evaluating Gas Motion Differences between Dichlorosilane and Trichlorosilane in Ambient Hydrogen in a Slim Vertical Cold Wall Chemical Vapor Deposition Reactor 被引量:1
13
作者 Mana Otani Toshinori Takahashi +3 位作者 Hitoshi Habuka Yuuki Ishida Shin-Ichi Ikeda Shiro Hara 《Advances in Chemical Engineering and Science》 2020年第3期190-200,共11页
A dichlorosilane gas and a trichlorosilane gas in ambient hydrogen were evaluated to show their different gas flow motions in a slim vertical cold wall chemical vapor deposition reactor for the Minimal Fab system. Thi... A dichlorosilane gas and a trichlorosilane gas in ambient hydrogen were evaluated to show their different gas flow motions in a slim vertical cold wall chemical vapor deposition reactor for the Minimal Fab system. This evaluation was performed for improving and controlling the film qualities and the productivities, using two quartz crystal microbalances (QCM) installed at the </span><span style="font-family:Verdana;">inlet and exhaust of the chamber by taking into account that the QCM frequency corresponds to the real time changes in the gas properties.</span><span style="font-family:Verdana;"> Typically, the time period approaching from the inlet to the exhaust was shorter for the trichlorosilane gas than that for the dichlorosilane gas. The trichlorosilane gas was shown to move like plug flow, while the dichlorosilane gas seemed to be well mixed in the entire chamber. 展开更多
关键词 Minimal Fab Chemical Vapor Deposition Reactor quartz Crystal Microbalance Silicon Epitaxial Growth TRICHLOROSILANE DICHLOROSILANE
下载PDF
Quartz Crystal Microbalance Sensor Deposited with LB Films of Functional Polymers for the Detection of Phenols in Vapour Phase
14
作者 YAN Li and ZHOU Xi chun (New Materials Plant, Central China Normal University, Wuhan, 430079 Department of Environmental Science & Natural Resource , Wuhan University, Wuhan, 430072) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1998年第4期85-89,共5页
IntroductionInrecentyearsanincreasingdemandforenvironmentalmonitoringhasstimulatedana-lyticalchemiststomakeg... IntroductionInrecentyearsanincreasingdemandforenvironmentalmonitoringhasstimulatedana-lyticalchemiststomakegreaterefortstodev... 展开更多
关键词 quartz crystal microbalance Chemical sensor Langmuir Blodgett film PHENOL Environmental monitoring
下载PDF
Determination of Paclitaxel Solubility in Carbon Dioxide Using Quartz Crystal Microbalance
15
作者 焦真 陈志明 +1 位作者 吴有庭 马少玲 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第2期227-231,共5页
A quartz crystal microbalance (QCM) is used to determine the phase equilibrium of paclitaxel-carbon dioxide system in the pressure range of 0-11 MPa and at temperatures of 35 °C,40 °C and 45 °C.The ex... A quartz crystal microbalance (QCM) is used to determine the phase equilibrium of paclitaxel-carbon dioxide system in the pressure range of 0-11 MPa and at temperatures of 35 °C,40 °C and 45 °C.The experimental results indicated that gaseous CO2 could be absorbed poorly into paclitaxel.The swelling of paclitaxel film in CO2 was observed before paclitaxel dissolved into supercritical carbon dioxide (ScCO2) with the increase of pressure.It was found that ScCO2 was not a good solvent for paclitaxel.The mole fraction of paclitaxel in ScCO2 was in the range of (4.5×10-9)-(7.8×10-9) under all our experimental conditions.Therefore,a much higher pressure than the CO2 supercritical point and/or a cosolvent must be used in any processes wherever paclitaxel dissolution in ScCO2 is required. 展开更多
关键词 PACLITAXEL carbon dioxide phase behavior quartz crystal microbalance
下载PDF
Electrochemical Quartz Crystal Microbalance(EQCM) Characterization of Electrodeposition and Catalytic Activity of Pd-based Electrocatalysts for Ethanol Oxidation
16
作者 KE Xi DENG Lu-lu +1 位作者 SHEN Pei-kang CUI Guo-feng 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2010年第3期443-448,共6页
Pd was electrochemically deposited on gold-coated quartz crystals at nanogram-level. The coulombic efficiency and initial nucleation and growth mechanism of potentiostatic Pd deposition were investigated via in situ e... Pd was electrochemically deposited on gold-coated quartz crystals at nanogram-level. The coulombic efficiency and initial nucleation and growth mechanism of potentiostatic Pd deposition were investigated via in situ electrochemical quartz crystal microbalance(EQCM). The coulombic efficieneies are 84%, 93% and 95% for Pd deposition at 0.3, 0.2 and 0.1 V(vs. SCE), respectively. The results of chronoamperometric measurements show that the Pd deposition proceeded by an instantaneous nucleation(at 0.3 V) or progressive nucleation(at 0.2 and 0.1 V) in a three-dimensional(3D) growth mode. The catalytic activity of Pd-based electrocatalyst for ethanol oxidation was characterized in an alkaline solution. It was found that the highest mass activity for ethanol oxidation on Pd-based electrocatalyst is 1.8× 10^4 A/(g Pd) deposited at 0.3 V for 5 s. 展开更多
关键词 Coulombic efficiency Nucleation and growth mechanism Electrochemical quartz crystal microbalance PALLADIUM Ethanol oxidation
下载PDF
An Unexpected Frequency Response of A Piezoelectric Quartz Crystal Sensor to the Density and Viscosity of the Liquid
17
作者 LiShunFENG JingTianHU +2 位作者 QiKANG ChangYingGUO DaZhongSHEN 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第4期509-512,共4页
An unexpected frequency response for a piezoelectric quartz crystal (PQC) sensor to liquid density and viscosity was reported. For a PQC oscillating in a liquid phase, the frequency shifts (?f ) show a wave-shape re... An unexpected frequency response for a piezoelectric quartz crystal (PQC) sensor to liquid density and viscosity was reported. For a PQC oscillating in a liquid phase, the frequency shifts (?f ) show a wave-shape response to liquid density (ρ) and viscosity (η) in fine structure, if the longitudinal wave effect was not eliminated. This result is different from the well-known linear relationship between of ?f and (ρη)1/2. An oscillating frequency-temperature curve of the sensor was observed and explained. 展开更多
关键词 Piezoelectric sensor quartz crystal liquid property longitudinal wave.
下载PDF
Charge Transport Processes of Immobilized Heteropolyanions at Self-assembled Monolayer Modified Gold Electrode by Electrochemical Quartz Crystal Microbalance Measurement
18
作者 BU Xin-yuan JIAO Lian-sheng +1 位作者 HAN Dong-xue YANG Gui-fu 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2009年第4期537-542,共6页
The in situ electrochemical quartz crystal microbalance(EQCM) technique was used to investigate the ion transport of immobilized heteropolyanions at a self-assembled monolayer(SAM) modified gold electrode during e... The in situ electrochemical quartz crystal microbalance(EQCM) technique was used to investigate the ion transport of immobilized heteropolyanions at a self-assembled monolayer(SAM) modified gold electrode during electrochemical redox process.A mixed transfer method was presented to analyse the abnormal change of resonant frequency based on the simultaneous insertion/extraction of different ions.The results indicate that the migration of HSO4-anions was indispensable in the redox process of the heteropolyanions in a 1 mol/L H2SO4 solution and played a key role in the abnormal change of the resonant frequency.Such a change was attributed to different packing densities derived by means of differently immobilized methods. 展开更多
关键词 HETEROPOLYANION Charge transport Self-assembled monolayer Electrochemical quartz crystal microbalance
下载PDF
Electric admittance analysis of quartz crystal resonator in thickness-shear mode induced by array of surface viscoelastic micro-beams
19
作者 Jiemin XIE Yuantai HU 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2017年第1期29-38,共10页
The electric admittance of a compound system composed of a thickness-shear mode (TSM) quartz crystal resonator (QCR) and an array of surface viscoelastic micro-beams (MBs) is studied. The governing equations of ... The electric admittance of a compound system composed of a thickness-shear mode (TSM) quartz crystal resonator (QCR) and an array of surface viscoelastic micro-beams (MBs) is studied. The governing equations of the MBs are derived from the Timoshenko-beam theory in consideration of shear deformation. The electrical admittance is described directly in terms of the physical properties of the surface epoxy resin (SU-8) MBs from an electrically forced vibration analysis. It is found that both the inertia effect and the constraint effect of the MBs produce competitive influence on the resonant frequency and admittance of the compound QCR system. By further comparing the numerical results calculated from the Timoshenko-beam model with those from the Euler-beam model, the shear deformation is found to lead to some deviation of an admittance spectrum. The deviations are revealed to be evident around the admittance peak(s) and reach the maximum when a natural frequency of the MBs is identical to the fundamental frequency of the QCR. Besides, a higher order vibration mode of the MBs corresponds to a larger deviation at the resonance. 展开更多
关键词 quartz crystal resonator (QCR) thickness-shear mode (TSM) electrical admittance shear deformation
下载PDF
Real-Time Characterization of Fibrinogen Interaction with Modified Titanium Dioxide Film by Quartz Crystal Microbalance with Dissipation
20
作者 An-sha Zhao Zhao Wang +2 位作者 Xiao-hua Zhu Manfred F. Maitz Nan Huang 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2014年第3期355-360,共6页
The adsorption of fibrinogen can be used as a quick indicator of surface haemocompatibility because of its prominent role in coagulation and platelet adhesion. In this work the molecular interaction between fibrinogen... The adsorption of fibrinogen can be used as a quick indicator of surface haemocompatibility because of its prominent role in coagulation and platelet adhesion. In this work the molecular interaction between fibrinogen and a modified titanium oxide surface/platelet has been studied by quartz crystal microbalanee with dissipation (QCM-D) in situ. In order to further characterize the conformation of adsorbed fibrinogen, αC and γ-chain antibody were used to check the orientation and denaturation of fibrinogen on solid surface. QCM-D investiga- tions revealed the fibrinogen have the trend to adsorb on hydropllilic surface in a side-on orientation by positively charged αC domains, which would reduce the exposure of platelet bonding site on γ chain and enable less platelet adhesion and be activated. These obser- vations suggest that certain conformations of adsorbed fibrinogen are less platelet adhesive than others, which opens a possibility for creating a non-platelet adhesive substrates. 展开更多
关键词 quartz crystal microbalance with dissipation Fibrinogen adsorption Confor- mation change Blood platelet
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部