<正>According to the piezoelectric equation and the vibration theory of the quartz crystal,the relations between the vibrating frequency and structural parameters under the thickness-shear-vibration of AT-cut qu...<正>According to the piezoelectric equation and the vibration theory of the quartz crystal,the relations between the vibrating frequency and structural parameters under the thickness-shear-vibration of AT-cut quartz crystal have been studied. The frequency conditions under which quartz crystal resonator formed stationary wave inside the electrode district and the transmission characteristics of wave outside the electrode district have also been discussed.A quartz crystal resonator was developed based on this analysis.The experiment showed that the force-sensing characteristics were independent of the fixation of the crystal edge.The detecting distinguish ability was up to 0.001°,and the short-term frequency stability was up to 1.38×10~ (-10)/min.展开更多
The dynamic characteristics of a quartz crystal resonator(QCR) in thicknessshear modes(TSM) with the upper surface covered by an array of micro-beams immersed in liquid are studied. The liquid is assumed to be inv...The dynamic characteristics of a quartz crystal resonator(QCR) in thicknessshear modes(TSM) with the upper surface covered by an array of micro-beams immersed in liquid are studied. The liquid is assumed to be inviscid and incompressible for simplicity. Dynamic equations of the coupled system are established. The added mass effect of liquid on micro-beams is discussed in detail. Characteristics of frequency shift are clarified for different liquid depths. Modal analysis shows that a drag effect of liquid has resulted in the change of phase of interaction(surface shear force), thus changing the system resonant frequency. The obtained results are useful in resonator design and applications.展开更多
With introduction of the first-order strain-gradient of surface micro-beams into the energy density function,we developed a two-dimensional dynamic model for a compound quartz crystal resonator(QCR) system,consistin...With introduction of the first-order strain-gradient of surface micro-beams into the energy density function,we developed a two-dimensional dynamic model for a compound quartz crystal resonator(QCR) system,consisting of a QCR and surface micro-beam arrays.The frequency shift that was induced by micro-beams with consideration of strain-gradients is discussed in detail and some useful results are obtained,which have important significance in resonator design and applications.展开更多
We study the dynamic behavior of a quartz crystal resonator (QCR) in thickness-shear vibrations with the upper surface covered by an array of micro-beams (MBs) under large deflection. Through taking into account t...We study the dynamic behavior of a quartz crystal resonator (QCR) in thickness-shear vibrations with the upper surface covered by an array of micro-beams (MBs) under large deflection. Through taking into account the continuous conditions of shear force and bending moment at the interface of MBs/resonator, dependences of frequency shift of the compound QCR system versus material parameter and geometrical parameter are illustrated in detail for nonlinear and linear vibrations. It is found that the frequency shift produces a little right (left) translation for increasing elastic modulus (length/radius ratio) of MBs. Moreover, the frequency right (left) translation distance caused by nonlinear deformation becomes more serious in the second-order mode than in the first-order one,展开更多
A scanning near field acoustic microscopy(SNAM) used in imaging the topography of precise surfaces is presented. As a micro force sensor, a non encapsulated 1 MHz quartz resonator is damped by hydrodynamic forces w...A scanning near field acoustic microscopy(SNAM) used in imaging the topography of precise surfaces is presented. As a micro force sensor, a non encapsulated 1 MHz quartz resonator is damped by hydrodynamic forces when approaching an object. Thus the oscillating characteristics of the leg of the quartz resonator change. While measuring the decrease of the amplitude of vibrating, the shape of the object can be obtained. Based on the analyses of the principle and key parameters of SNAM, a SNAM is exploited. A lateral resolution of 0.5 μm and vertical resolution of 2 nm has been achieved in the experiments.展开更多
Quartz crystal resonators (QCRs) with circular electrodes have been widely used for various liquid and gas sensing applications. In this work, quartz crystal resonators with elliptical electrodes were studied and te...Quartz crystal resonators (QCRs) with circular electrodes have been widely used for various liquid and gas sensing applications. In this work, quartz crystal resonators with elliptical electrodes were studied and tested for liquid property measurement. Mindlin's theory was used to optimize the dimension and geometry of the electrodes and a 5-MHz QCR with minimum series resistance and without any spurious modes was obtained. A series of AT-cut QCRs with elliptical electrodes of different sizes were fabricated and their sensing performances were compared to devices with circular electrodes. The experimental result shows that the device with elliptical electrodes can obtain lower resonance impedance and a higher Q factor, which results in a better loading capability. Even though the sensitivities of devices with elliptical and circular electrodes are found to be similar, the sensor with elliptical electrodes has much higher resolution due to a better frequency stability. The study indicates that the performance of QCRs with elliptical electrodes is superior to that of traditional QCRs with circular electrodes.展开更多
The electric admittance of a compound system composed of a thickness-shear mode (TSM) quartz crystal resonator (QCR) and an array of surface viscoelastic micro-beams (MBs) is studied. The governing equations of ...The electric admittance of a compound system composed of a thickness-shear mode (TSM) quartz crystal resonator (QCR) and an array of surface viscoelastic micro-beams (MBs) is studied. The governing equations of the MBs are derived from the Timoshenko-beam theory in consideration of shear deformation. The electrical admittance is described directly in terms of the physical properties of the surface epoxy resin (SU-8) MBs from an electrically forced vibration analysis. It is found that both the inertia effect and the constraint effect of the MBs produce competitive influence on the resonant frequency and admittance of the compound QCR system. By further comparing the numerical results calculated from the Timoshenko-beam model with those from the Euler-beam model, the shear deformation is found to lead to some deviation of an admittance spectrum. The deviations are revealed to be evident around the admittance peak(s) and reach the maximum when a natural frequency of the MBs is identical to the fundamental frequency of the QCR. Besides, a higher order vibration mode of the MBs corresponds to a larger deviation at the resonance.展开更多
During the fabrication of quartz crystal resonators(QCRs),parallelism error is inevitably generated,which is rarely investigated.In order to reveal the influence of parallelism error on the working performance of QCRs...During the fabrication of quartz crystal resonators(QCRs),parallelism error is inevitably generated,which is rarely investigated.In order to reveal the influence of parallelism error on the working performance of QCRs,the coupled vibration of a non-parallel AT-cut quartz crystal plate with electrodes is systematically studied from the views of theoretical analysis and numerical simulations.The two-dimensional thermal incremental field equations are solved for the free vibration analysis via the coefficient-formed partial differential equation module of the COMSOL Multiphysics software,from which the frequency spectra,frequency–temperature curves,and mode shapes are discussed in detail.Additionally,the piezoelectric module is utilized to obtain the admittance response under different conditions.It is demonstrated that the parallelism error reduces the resonant frequency.Additionally,symmetry broken by the non-parallelism increases the probability of activity dip and is harmful to QCR’s thermal stability.However,if the top and bottom surfaces incline synchronously in the same direction,the influence of parallelism error is tiny.The conclusions achieved are helpful for the QCR design,and the methodology presented can also be applied to other wave devices.展开更多
We studied the coupled dynamic behavior of a quartz-crystal-resonator (QCR)/micro- beams system in the thickness-shear motions. Through taking into account the couple stress in the dynamic equations of the quartz pl...We studied the coupled dynamic behavior of a quartz-crystal-resonator (QCR)/micro- beams system in the thickness-shear motions. Through taking into account the couple stress in the dynamic equations of the quartz plate, both continuous conditions of shear force and bending moment at the resonator/micro-beams interface are realized. Frequency shift of the compound QCR system induced by micro-beams is studied in detail. The obtained results are useful in device design and frequency-stability analysis of quartz crystal resonators.展开更多
We report a resonant method to measure the wall capacitance(C_w) and solution resistance(R_S) in a capacitively coupled contactless conductivity detector(C^4D).Under the typical operating conditions in capillary...We report a resonant method to measure the wall capacitance(C_w) and solution resistance(R_S) in a capacitively coupled contactless conductivity detector(C^4D).Under the typical operating conditions in capillary electrophoresis(I.D.50μm,O.D. 360μm,electrode length of 4 mm,electrode gap of 1 mm,frequency of 200 kHz),the values of C_w measured in 1 and 20 mmol/L NaCl solutions are 2.8 and 32 fF,which are only 1.1%and 12%of prediction by the equation in references,respectively.The value of R_S is less than the prediction in solutions withκ〈0.02 S/m.The response current of C^4D is due to the change in C_w because the total impedance of a C^4D is composed mainly by the impedance from C_w.展开更多
In this work, a separated-electrode piezoelectric sensor(SEPS), constructed by a naked quartz crystal mounted between two electrodes, is reported for applications in a corrosive gaseous phase. The response of SEPS w...In this work, a separated-electrode piezoelectric sensor(SEPS), constructed by a naked quartz crystal mounted between two electrodes, is reported for applications in a corrosive gaseous phase. The response of SEPS was measured by an impedance analysis method. It was shown that SEPS has an excellent frequency stability because its quality factor is in the order of 10^5. The SEPS can be operated even with the electrode gap in air larger than 1 cm. Compared with a conventional quartz crystal microbalance, the resonant frequency of the SEPS is independent of the mass change in the electrode. The SEPS was applied to monitor the adsorption of iodine on quartz surface and zeolitic-imidazolate framework-8(ZIF-8) film as well as in the transfer of iodine between two ZIF-8 films. The SEPS offers the advantages of easy preparation, corrosion-resistant and convenience in combination with mass and optical measurements.展开更多
文摘<正>According to the piezoelectric equation and the vibration theory of the quartz crystal,the relations between the vibrating frequency and structural parameters under the thickness-shear-vibration of AT-cut quartz crystal have been studied. The frequency conditions under which quartz crystal resonator formed stationary wave inside the electrode district and the transmission characteristics of wave outside the electrode district have also been discussed.A quartz crystal resonator was developed based on this analysis.The experiment showed that the force-sensing characteristics were independent of the fixation of the crystal edge.The detecting distinguish ability was up to 0.001°,and the short-term frequency stability was up to 1.38×10~ (-10)/min.
基金Project supported by the National Natural Science Foundation of China(Nos.11272127 and51425006)the Research Fund for the Doctoral Program of Higher Education of China(No.20130142110022)the Grant from the Impact and Safety of Coastal Engineering Initiative Program of Zhejiang Provincial Government at Ningbo University(No.zj1213)
文摘The dynamic characteristics of a quartz crystal resonator(QCR) in thicknessshear modes(TSM) with the upper surface covered by an array of micro-beams immersed in liquid are studied. The liquid is assumed to be inviscid and incompressible for simplicity. Dynamic equations of the coupled system are established. The added mass effect of liquid on micro-beams is discussed in detail. Characteristics of frequency shift are clarified for different liquid depths. Modal analysis shows that a drag effect of liquid has resulted in the change of phase of interaction(surface shear force), thus changing the system resonant frequency. The obtained results are useful in resonator design and applications.
基金supported by the National Science Foundation of China(Grants 11272127 and 51435006)Research Fund for the Doctoral Program of Higher Education of China(Grant 20130142110022)the Grant from the Impact and Safety of Coastal Engineering Initiative Program of Zhejiang Provincial Government at Ningbo University(Grant zj1213)
文摘With introduction of the first-order strain-gradient of surface micro-beams into the energy density function,we developed a two-dimensional dynamic model for a compound quartz crystal resonator(QCR) system,consisting of a QCR and surface micro-beam arrays.The frequency shift that was induced by micro-beams with consideration of strain-gradients is discussed in detail and some useful results are obtained,which have important significance in resonator design and applications.
基金supported by the National Natural Science Foundation of China(11272127 and 51435006)the Research Fund for the Doctoral Program of Higher Education of China(20130142110022)
文摘We study the dynamic behavior of a quartz crystal resonator (QCR) in thickness-shear vibrations with the upper surface covered by an array of micro-beams (MBs) under large deflection. Through taking into account the continuous conditions of shear force and bending moment at the interface of MBs/resonator, dependences of frequency shift of the compound QCR system versus material parameter and geometrical parameter are illustrated in detail for nonlinear and linear vibrations. It is found that the frequency shift produces a little right (left) translation for increasing elastic modulus (length/radius ratio) of MBs. Moreover, the frequency right (left) translation distance caused by nonlinear deformation becomes more serious in the second-order mode than in the first-order one,
基金This project is supported by Doctoral Grant of National Education Ministry (No.97048707).
文摘A scanning near field acoustic microscopy(SNAM) used in imaging the topography of precise surfaces is presented. As a micro force sensor, a non encapsulated 1 MHz quartz resonator is damped by hydrodynamic forces when approaching an object. Thus the oscillating characteristics of the leg of the quartz resonator change. While measuring the decrease of the amplitude of vibrating, the shape of the object can be obtained. Based on the analyses of the principle and key parameters of SNAM, a SNAM is exploited. A lateral resolution of 0.5 μm and vertical resolution of 2 nm has been achieved in the experiments.
基金supported by the National Natural Science Foundation of China (Grant No.60571014)
文摘Quartz crystal resonators (QCRs) with circular electrodes have been widely used for various liquid and gas sensing applications. In this work, quartz crystal resonators with elliptical electrodes were studied and tested for liquid property measurement. Mindlin's theory was used to optimize the dimension and geometry of the electrodes and a 5-MHz QCR with minimum series resistance and without any spurious modes was obtained. A series of AT-cut QCRs with elliptical electrodes of different sizes were fabricated and their sensing performances were compared to devices with circular electrodes. The experimental result shows that the device with elliptical electrodes can obtain lower resonance impedance and a higher Q factor, which results in a better loading capability. Even though the sensitivities of devices with elliptical and circular electrodes are found to be similar, the sensor with elliptical electrodes has much higher resolution due to a better frequency stability. The study indicates that the performance of QCRs with elliptical electrodes is superior to that of traditional QCRs with circular electrodes.
基金Project supported by the National Natural Science Foundation of China(Nos.11272127 and51435006)the Research Fund for the Doctoral Program of Higher Education of China(No.20130142110022)
文摘The electric admittance of a compound system composed of a thickness-shear mode (TSM) quartz crystal resonator (QCR) and an array of surface viscoelastic micro-beams (MBs) is studied. The governing equations of the MBs are derived from the Timoshenko-beam theory in consideration of shear deformation. The electrical admittance is described directly in terms of the physical properties of the surface epoxy resin (SU-8) MBs from an electrically forced vibration analysis. It is found that both the inertia effect and the constraint effect of the MBs produce competitive influence on the resonant frequency and admittance of the compound QCR system. By further comparing the numerical results calculated from the Timoshenko-beam model with those from the Euler-beam model, the shear deformation is found to lead to some deviation of an admittance spectrum. The deviations are revealed to be evident around the admittance peak(s) and reach the maximum when a natural frequency of the MBs is identical to the fundamental frequency of the QCR. Besides, a higher order vibration mode of the MBs corresponds to a larger deviation at the resonance.
基金supported by the National Natural Science Foundation of China(12061131013,11972276,12172171 and 12102183)the Fundamental Research Funds for the Central Universities(NE2020002 andNS2022011)+5 种基金JiangsuHigh-Level Innovative and Entrepreneurial Talents Introduction Plan(Shuangchuang Doctor Program,JSSCBS20210166)the National Natural Science Foundation of Jiangsu Province(BK20211176)the State Key Laboratory of Mechanics and Control of Mechanical Structures at NUAA(No.MCMS-I-0522G01)Local Science andTechnologyDevelopment Fund ProjectsGuided by the CentralGovernment(2021Szvup061)the Opening Projects from the Key Laboratory of Impact and Safety Engineering of Ningbo University(CJ202104)a project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD).
文摘During the fabrication of quartz crystal resonators(QCRs),parallelism error is inevitably generated,which is rarely investigated.In order to reveal the influence of parallelism error on the working performance of QCRs,the coupled vibration of a non-parallel AT-cut quartz crystal plate with electrodes is systematically studied from the views of theoretical analysis and numerical simulations.The two-dimensional thermal incremental field equations are solved for the free vibration analysis via the coefficient-formed partial differential equation module of the COMSOL Multiphysics software,from which the frequency spectra,frequency–temperature curves,and mode shapes are discussed in detail.Additionally,the piezoelectric module is utilized to obtain the admittance response under different conditions.It is demonstrated that the parallelism error reduces the resonant frequency.Additionally,symmetry broken by the non-parallelism increases the probability of activity dip and is harmful to QCR’s thermal stability.However,if the top and bottom surfaces incline synchronously in the same direction,the influence of parallelism error is tiny.The conclusions achieved are helpful for the QCR design,and the methodology presented can also be applied to other wave devices.
基金supported by the National Nature Science Foundation of China(Nos.11272127 and 51435006)by Research Fund for the Doctoral Program of Higher Education of China(No.20130142110022)by Grant from the Impact and Safety of Coastal Engineering Initiative Program of Zhejiang Provincial Government at Ningbo University(No.zj1213)
文摘We studied the coupled dynamic behavior of a quartz-crystal-resonator (QCR)/micro- beams system in the thickness-shear motions. Through taking into account the couple stress in the dynamic equations of the quartz plate, both continuous conditions of shear force and bending moment at the resonator/micro-beams interface are realized. Frequency shift of the compound QCR system induced by micro-beams is studied in detail. The obtained results are useful in device design and frequency-stability analysis of quartz crystal resonators.
基金supported by the National Natural Science Foundation of China(nos.20975062 and 21175084)
文摘We report a resonant method to measure the wall capacitance(C_w) and solution resistance(R_S) in a capacitively coupled contactless conductivity detector(C^4D).Under the typical operating conditions in capillary electrophoresis(I.D.50μm,O.D. 360μm,electrode length of 4 mm,electrode gap of 1 mm,frequency of 200 kHz),the values of C_w measured in 1 and 20 mmol/L NaCl solutions are 2.8 and 32 fF,which are only 1.1%and 12%of prediction by the equation in references,respectively.The value of R_S is less than the prediction in solutions withκ〈0.02 S/m.The response current of C^4D is due to the change in C_w because the total impedance of a C^4D is composed mainly by the impedance from C_w.
基金financial support by National Natural Science Foundation of China(Nos.21175084,21275091)the Opening Fund of Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research(Hunan Normal University),Ministry of Education(No.KLCBTCMR2001-01)Research Fund for the Doctoral Program of Higher Education of China(No.20113704110003)
文摘In this work, a separated-electrode piezoelectric sensor(SEPS), constructed by a naked quartz crystal mounted between two electrodes, is reported for applications in a corrosive gaseous phase. The response of SEPS was measured by an impedance analysis method. It was shown that SEPS has an excellent frequency stability because its quality factor is in the order of 10^5. The SEPS can be operated even with the electrode gap in air larger than 1 cm. Compared with a conventional quartz crystal microbalance, the resonant frequency of the SEPS is independent of the mass change in the electrode. The SEPS was applied to monitor the adsorption of iodine on quartz surface and zeolitic-imidazolate framework-8(ZIF-8) film as well as in the transfer of iodine between two ZIF-8 films. The SEPS offers the advantages of easy preparation, corrosion-resistant and convenience in combination with mass and optical measurements.