期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Quick selection of aluminum galvanic anodes in oil brine via galvanic current
1
作者 HAO Xiao-jun LEI Ying-chun +2 位作者 HOU Hua ZHAO Yu-hong WANG Yi-du 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2017年第4期334-339,共6页
According to dynamics of coupled galvanic anode with carbon steel,the integral of galvanic current vs.time is approximately equal to actual current capacity of galvanic anode.Galvanic current of cast aluminum galvanic... According to dynamics of coupled galvanic anode with carbon steel,the integral of galvanic current vs.time is approximately equal to actual current capacity of galvanic anode.Galvanic current of cast aluminum galvanic anode coupled with carbon steel is tested in3.5%NaCl solution and ambient temperature.Rapid evaluation the performance of galvanic anode using galvanic current is feasible,and the test time is20min.The galvanic current is used to select aluminum galvanic anodes in oil brine,and then test the galvanic anodes with impressed current test method.The result shows,the performance of galvanic anodes degrads in oil brine,but has not much difference in the two media to the preferable anodes,and the optimal galvanic anode is gained. 展开更多
关键词 quick selection aluminum galvanic anode galvanic current oil brine