The objective of this study is to investigate the adsorption characteristics of granular activated carbon GAC/R-134a pair in the temperature range of 20℃?- 60℃?and pressure up to 10 bars. The Dubinin-Astakhov adsorp...The objective of this study is to investigate the adsorption characteristics of granular activated carbon GAC/R-134a pair in the temperature range of 20℃?- 60℃?and pressure up to 10 bars. The Dubinin-Astakhov adsorption equilibrium model is fit to experimental data with acceptable error limit. The pressure-temperature-concentration (P-T-X) diagram of the pair is also presented. The isosteric heat of adsorption of R-134a on activated carbon has been calculated using the Clausius-Clapeyron equation as a function of adsorption capacity. The maximum adsorption capacity was found to be 1.92 kgR134a/kg carbon at 20℃?after 1200 s. The experimental results also show that the increase of heat transfer area improves the adsorption capacity per kg of adsorber, which leads to the design of a finned tubes heat exchanger adsorption unit.展开更多
This article presents an experimental investigation on condensation heat transfer of R-134a in horizontal straight and helically coiled tube-in-tube heat exchangers. The experiments were carried out at three saturatio...This article presents an experimental investigation on condensation heat transfer of R-134a in horizontal straight and helically coiled tube-in-tube heat exchangers. The experiments were carried out at three saturation temperatures(35 ℃ , 40 ℃ and 45 ℃ ) with the refrigerant mass flux varying from 100 kg/m2 s to 400 kg/m2 s and the vapor quality ranging from 0.1 to 0.8. The effects of vapor quality and mass flux of R-134a on the condensation heat transfer coefficient were investigated. The results indicate that the condensation heat transfer coefficients of the helical section are 4%-13.8% higher than that of the straight section. The experimental results were compared with the data available in literature for helical and straight pipes.展开更多
Organic Rankine Cycle(ORC)is one of the solutions to utilize a low temperature geothermal fluid for power generation.The ORC system can be placed at the exit of the separator to extract energy from brine.Furthermore,o...Organic Rankine Cycle(ORC)is one of the solutions to utilize a low temperature geothermal fluid for power generation.The ORC system can be placed at the exit of the separator to extract energy from brine.Furthermore,one of the main components of the system and very important is the pump.Therefore,in this research,the pump rotation is examined to investigate the effect on power output and energy efficiency for low temperature geothermal fluid.The rotation is determined by using an inverter with the following frequencies:7.5,10,12.5,15 and 17.5 Hz,respectively.R-134 working fluid is employed with 373.15 K evaporator temperature in relation to the low temperature of the geothermal fluid.Furthermore,the condenser temperature and fluid pressure were set up to 293.15 K and 5×10^(5) Pa,respectively.This research uses a DC generator with a maximum power of 750 Watt and the piping system is made from copper alloy C12200 ASTM B280 with size 1.905×10^(−2) m and a thickness of 8×10^(−4) m.The results showed that there is an increase in mass flow rate,enthalpy and generator power output along with increasing pump rotation.In addition,it showed that the maximum generator output power was 377.31 Watt at the highest pump rotation with a frequency of 17.5 Hz.展开更多
文摘The objective of this study is to investigate the adsorption characteristics of granular activated carbon GAC/R-134a pair in the temperature range of 20℃?- 60℃?and pressure up to 10 bars. The Dubinin-Astakhov adsorption equilibrium model is fit to experimental data with acceptable error limit. The pressure-temperature-concentration (P-T-X) diagram of the pair is also presented. The isosteric heat of adsorption of R-134a on activated carbon has been calculated using the Clausius-Clapeyron equation as a function of adsorption capacity. The maximum adsorption capacity was found to be 1.92 kgR134a/kg carbon at 20℃?after 1200 s. The experimental results also show that the increase of heat transfer area improves the adsorption capacity per kg of adsorber, which leads to the design of a finned tubes heat exchanger adsorption unit.
基金the National Natural Science Foundation of China (Grant No. 50376030).
文摘This article presents an experimental investigation on condensation heat transfer of R-134a in horizontal straight and helically coiled tube-in-tube heat exchangers. The experiments were carried out at three saturation temperatures(35 ℃ , 40 ℃ and 45 ℃ ) with the refrigerant mass flux varying from 100 kg/m2 s to 400 kg/m2 s and the vapor quality ranging from 0.1 to 0.8. The effects of vapor quality and mass flux of R-134a on the condensation heat transfer coefficient were investigated. The results indicate that the condensation heat transfer coefficients of the helical section are 4%-13.8% higher than that of the straight section. The experimental results were compared with the data available in literature for helical and straight pipes.
基金gratitude to LPPM UNS,for funding this research project titled“Increasing the Capacity of Geothermal Power Plants Using Exergy Analysis to Support Government Policy in the Development of a 35 Thousand MW Power Plant(Hibah Penelitian Unggulan UNS(PU-UNS))”.
文摘Organic Rankine Cycle(ORC)is one of the solutions to utilize a low temperature geothermal fluid for power generation.The ORC system can be placed at the exit of the separator to extract energy from brine.Furthermore,one of the main components of the system and very important is the pump.Therefore,in this research,the pump rotation is examined to investigate the effect on power output and energy efficiency for low temperature geothermal fluid.The rotation is determined by using an inverter with the following frequencies:7.5,10,12.5,15 and 17.5 Hz,respectively.R-134 working fluid is employed with 373.15 K evaporator temperature in relation to the low temperature of the geothermal fluid.Furthermore,the condenser temperature and fluid pressure were set up to 293.15 K and 5×10^(5) Pa,respectively.This research uses a DC generator with a maximum power of 750 Watt and the piping system is made from copper alloy C12200 ASTM B280 with size 1.905×10^(−2) m and a thickness of 8×10^(−4) m.The results showed that there is an increase in mass flow rate,enthalpy and generator power output along with increasing pump rotation.In addition,it showed that the maximum generator output power was 377.31 Watt at the highest pump rotation with a frequency of 17.5 Hz.