Radiation-induced acoustic computed tomography(RACT)is an evolving biomedical imaging modality that aims to reconstruct the radiation energy deposition in tissues.Traditional backprojection(BP)reconstructions carry no...Radiation-induced acoustic computed tomography(RACT)is an evolving biomedical imaging modality that aims to reconstruct the radiation energy deposition in tissues.Traditional backprojection(BP)reconstructions carry noisy and limited-view artifacts.Model-based algorithms have been demonstrated to overcome the drawbacks of BPs.However,model-based algorithms are relatively more complex to develop and computationally demanding.Furthermore,while a plethora of novel algorithms has been developed over the past decade,most of these algorithms are either not accessible,readily available,or hard to implement for researchers who are not well versed in programming.We developed a user-friendly MATLAB-based graphical user interface(GUI;RACT2D)that facilitates back-projection and model-based image reconstructions for twodimensional RACT problems.We included numerical and experimental X-ray-induced acoustic datasets to demonstrate the capabilities of the GUI.The developed algorithms support parallel computing for evaluating reconstructions using the cores of the computer,thus further accelerating the reconstruction speed.We also share the MATLAB-based codes for evaluating RACT reconstructions,which users with MATLAB programming expertise can further modify to suit their needs.The shared GUI and codes can be of interest to researchers across the globe and assist them in e±cient evaluation of improved RACT reconstructions.展开更多
The Clinical Strategies Implementation scale (CSI) was originally designed to be used by external reviewers in order to measure the extent to which evidence-based strategies had been implemented in the treatment of pe...The Clinical Strategies Implementation scale (CSI) was originally designed to be used by external reviewers in order to measure the extent to which evidence-based strategies had been implemented in the treatment of persons with schizophrenia spectrum disorders according to Resource-group Assertive Community Treatment (RACT). The present investigation had two aims: 1) to conduct a revision of CSI and to examine the revised instrument (CSI-R) in terms of interrater reliability (Study I);2) to compare assessments of CSI-R made by experienced assessors with assessments made by students in case management (Study II) in order to determine whether the instrument has validity even when more inexperienced persons are using it. In Study I six raters, who took part in 12 to 15 cases from three outpatient community mental health teams, participated. Results indicated that internal consistency of the CSI-R was strong (alpha = 0.89) as well as correlations between individual raters’ (r between 0.80-0.98). In Study II 91 newly trained RACT praxis trainees participated. Each of them followed one case for eighteen months, i.e., the client which they had been assigned during training (n = 91). The five external auditors in the education program then independently assessed the 91 cases with the CSI-R. Results showed significant correlations between experts and trainees (rho = 0.68,展开更多
基金supported by the National Institute of Health (R37CA240806)and American Cancer Society (133697-RSG-19-110-01-CCE)support from UCI Chao Family Comprehensive Cancer Center (P30CA062203).
文摘Radiation-induced acoustic computed tomography(RACT)is an evolving biomedical imaging modality that aims to reconstruct the radiation energy deposition in tissues.Traditional backprojection(BP)reconstructions carry noisy and limited-view artifacts.Model-based algorithms have been demonstrated to overcome the drawbacks of BPs.However,model-based algorithms are relatively more complex to develop and computationally demanding.Furthermore,while a plethora of novel algorithms has been developed over the past decade,most of these algorithms are either not accessible,readily available,or hard to implement for researchers who are not well versed in programming.We developed a user-friendly MATLAB-based graphical user interface(GUI;RACT2D)that facilitates back-projection and model-based image reconstructions for twodimensional RACT problems.We included numerical and experimental X-ray-induced acoustic datasets to demonstrate the capabilities of the GUI.The developed algorithms support parallel computing for evaluating reconstructions using the cores of the computer,thus further accelerating the reconstruction speed.We also share the MATLAB-based codes for evaluating RACT reconstructions,which users with MATLAB programming expertise can further modify to suit their needs.The shared GUI and codes can be of interest to researchers across the globe and assist them in e±cient evaluation of improved RACT reconstructions.
文摘将经过多级破碎分选所得的废线路板粉末过60目筛,以2 mol/L HCl溶液、超纯水洗涤,并用丙酮脱水。将预处理后的滤渣、滤纸填入萃取池,或者用新滤纸包裹后置于索氏提取管内,添加5μL内标物,分别用加速溶剂萃取法(ASE)或索氏提取(SE)法进行萃取,依次采用多层硅胶柱和活性炭柱对萃取提取物进行净化、洗脱,得到二噁英测试样品。用同位素稀释-高分辨气相色谱-质谱联用仪分析样品中二噁英的含量。考察两种提取方法及不同氯代数对15种^(13)C-2,3,7,8-PCDD/Fs回收率的影响,比较两种方法的准确度和精密度。结果表明,ASE和SE对15种^(13)C-2,3,7,8-PCDD/Fs的回收率分别为54.3%~113.0%和28.3%~77.7%,实测废线路板中二噁英毒性当量(Toxic equivalent quangtity,TEQ)分别为0.075 ng TEQ/kg和0.266 ng TEQ/kg。在方法精密度允许范围内,ASE相对具有简单快速、溶剂用量少和准确的优势。
文摘The Clinical Strategies Implementation scale (CSI) was originally designed to be used by external reviewers in order to measure the extent to which evidence-based strategies had been implemented in the treatment of persons with schizophrenia spectrum disorders according to Resource-group Assertive Community Treatment (RACT). The present investigation had two aims: 1) to conduct a revision of CSI and to examine the revised instrument (CSI-R) in terms of interrater reliability (Study I);2) to compare assessments of CSI-R made by experienced assessors with assessments made by students in case management (Study II) in order to determine whether the instrument has validity even when more inexperienced persons are using it. In Study I six raters, who took part in 12 to 15 cases from three outpatient community mental health teams, participated. Results indicated that internal consistency of the CSI-R was strong (alpha = 0.89) as well as correlations between individual raters’ (r between 0.80-0.98). In Study II 91 newly trained RACT praxis trainees participated. Each of them followed one case for eighteen months, i.e., the client which they had been assigned during training (n = 91). The five external auditors in the education program then independently assessed the 91 cases with the CSI-R. Results showed significant correlations between experts and trainees (rho = 0.68,