期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
RELAP5 Code Study of ROSA/LSTF Experiments on PWR Safety System Using Steam Generator Secondary-Side Depressurization 被引量:1
1
作者 Takeshi Takeda Akira Ohnuki Hiroaki Nishi 《Journal of Energy and Power Engineering》 2015年第5期426-442,共17页
RELAP5 (reactor excursion and leak analysis program, version 5) code analyses were performed on two ROSA/LSTF (rig of safety assessment/large scale test facility) experiments on PWR (pressurized water reactor) s... RELAP5 (reactor excursion and leak analysis program, version 5) code analyses were performed on two ROSA/LSTF (rig of safety assessment/large scale test facility) experiments on PWR (pressurized water reactor) safety system that simulated cold leg small-break loss-of-coolant accidents with 8-in. or 4-in. diameter break using SG (steam generator) secondary-side depressurization. The SG depressurization was initiated by fully opening the depressurization valves in both SGs immediately after a safety injection signal. In the 8-in. break test, loop seal clearing occurred and then core uncovery and heatup took place by core boil-off. Core collapsed liquid level recovered after the initiation of accumulator coolant injection, and long-term core cooling was ensured by the actuation of low-pressure injection system. In the 4-in. break test, on the other hand, there was no core uncovery and heatup due to smaller break flow rate than in the 8-in. break test. Adjustment of Cd (break discharge coefficient) for two-phase discharge flow predicted the break flow rate reasonably well. The code well predicted the overall trend of the major thermal-hydraulic response observed in the two LSTF tests by the Cd adjustment. The code, however, overpredicted the peak cladding temperature because of underprediction of the core collapsed liquid level due to inadequate prediction of the accumulator flow rate in the 8-in. break case. 展开更多
关键词 PWR safety system ROSAILSTF small-break loss-of-coolant accident SG depressurization relap5 code.
下载PDF
REPEC非加热实验的RELAP程序模拟
2
作者 李永春 周卫华 +2 位作者 杨燕华 匡波 程旭 《上海交通大学学报》 EI CAS CSCD 北大核心 2011年第3期408-412,共5页
为研究压力容器外部冷却过程中的两相流动和传热现象,采用安全分析中通用的RELAP分析程序对REPEC非加热研究实验进行模拟计算,通过改变体积流量大小、注气方式和进出口面积对自然循环流率和外部冷却两相流动现象进行分析.结果表明,模拟... 为研究压力容器外部冷却过程中的两相流动和传热现象,采用安全分析中通用的RELAP分析程序对REPEC非加热研究实验进行模拟计算,通过改变体积流量大小、注气方式和进出口面积对自然循环流率和外部冷却两相流动现象进行分析.结果表明,模拟结果与实验结果的一致性较好;循环流量随体积流量的提高呈现先增强后降低的趋势;进出口面积增大可以提高自然循环流量,但出口面积变化对循环流率和流动稳定性的影响更为显著. 展开更多
关键词 压力容器外部冷却 大型先进压水堆 relap程序 自然循环
下载PDF
套管式直流蒸汽发生器负荷跟随动态特性分析 被引量:6
3
作者 刘建阁 彭敏俊 +2 位作者 张志俭 徐文奇 成守宇 《原子能科学技术》 EI CAS CSCD 北大核心 2010年第2期175-182,共8页
新型核动力装置采用紧凑型的套管式直流蒸汽发生器,根据传热特点,对其热工特性进行了分析。采用主冷却剂平均温度不变和二回路侧蒸汽压力不变的双恒定运行方案及经典PID控制器和负荷跟随运行模式,结合SCDAP/RELAP5/MOD3.4程序,研究了套... 新型核动力装置采用紧凑型的套管式直流蒸汽发生器,根据传热特点,对其热工特性进行了分析。采用主冷却剂平均温度不变和二回路侧蒸汽压力不变的双恒定运行方案及经典PID控制器和负荷跟随运行模式,结合SCDAP/RELAP5/MOD3.4程序,研究了套管式直流蒸汽发生器的动态特性,分析了降负荷时套管式直流蒸汽发生器的动态响应过程。结果表明,通过优化PID控制器参数,对给水流量进行精确控制,可满足蒸汽压力恒定的控制策略,实现双恒定运行方案,使一、二回路的运行达到较好的协调;套管式直流蒸汽发生器升降功率速度快,蒸汽压力稳定,且动态响应时间短。 展开更多
关键词 套管式直流蒸汽发生器 动态特性 负荷跟随 PID控制器 SCDAP/relap5/MOD3.4程序
下载PDF
CFETR氦冷偏滤器回路LOCA事故放射性释放分析
4
作者 胡泊 黄文玉 +5 位作者 周冰 王晓宇 王艳灵 卢勇 张龙 刘宽程 《核聚变与等离子体物理》 CAS CSCD 北大核心 2023年第2期150-155,共6页
基于中国聚变工程实验堆(CFETR)氦冷偏滤器回路设计方案,建立事故计算模型,针对真空室外冷却剂丧失事故(Ex-vessel LOCA)和Ex-vessel LOCA叠加真空室内冷却剂丧失事故(In-vessel LOCA),对其放射性释放后果进行了评估。结果表明:Ex-vesse... 基于中国聚变工程实验堆(CFETR)氦冷偏滤器回路设计方案,建立事故计算模型,针对真空室外冷却剂丧失事故(Ex-vessel LOCA)和Ex-vessel LOCA叠加真空室内冷却剂丧失事故(In-vessel LOCA),对其放射性释放后果进行了评估。结果表明:Ex-vessel LOCA事故中氦气泄漏会导致管道所在房间压力小幅度上涨,氦气泄漏量低于安全限值;在In-vessel LOCA叠加Ex-vessel LOCA事故中,不考虑隔离阀时房间气体会向真空室倒流,使真空室泄漏量超过安全限值;在加入隔离阀后,真空室泄漏量与房间泄漏量均满足验收准则。同时基于计算结果,估计了事故工况下氚的泄漏量。结果验证了方案的安全性,并为后续设计工作提供了数据支持。 展开更多
关键词 CFETR 氦冷偏滤器 relap代码 Ex-vessel LOCA In-vessel LOCA
下载PDF
Study of Accident Progression in Unsealed WWER-1000/V320 Reactor during Maintenance
5
作者 Pavlin Groudev Marina Andreeva 《Journal of Power and Energy Engineering》 2016年第8期68-78,共11页
This paper discusses the results obtained during an investigation of WWER-1000 Nuclear Power Plant (NPP) behavior at shutdown reactor during maintenance. For the purpose of the analysis is selected a plant operating s... This paper discusses the results obtained during an investigation of WWER-1000 Nuclear Power Plant (NPP) behavior at shutdown reactor during maintenance. For the purpose of the analysis is selected a plant operating state with unsealed primary circuit by removing the MCP head. The reference nuclear power plant is Unit 6 at Kozloduy NPP (KNPP) site. RELAP5/ MOD3.2 computer code has been used to simulate the transient for WWER-1000/V320 NPP model. A model of WWER-1000 based on Unit 6 of KNPP has been developed for the RELAP5/MOD3.2 code at the Institute for Nuclear Research and Nuclear Energy-Bulgarian Academy of Sciences (INRNE-BAS), Sofia. The plant modifications performed in frame of modernization program have been taken into account for the investigated conditions for the unsealed primary circuit. The most specific in this analysis compared to the analyses of NPP accidents at full power is the unavailability of some important safety systems. For the purpose of the present investigation two scenarios have been studied, involving a different number of safety systems with and without operator actions. The selected initiating event and scenarios are used in support of analytical validation of Emergency Operating Procedures (EOP) at low power and they are based on the suggestions of leading KNPP experts and are important in support of analytical validation of EOP at low power. 展开更多
关键词 Nuclear Power Plant Safety relap5/MOD3.2 Computer code Unsealed WWER Type Reactor Residual Heat Removal System Low Power and Cold Conditions
下载PDF
RELAP/SCDAPSIM/MOD4.0程序的FHR应用扩展及验证 被引量:6
6
作者 姜淑颖 程懋松 +1 位作者 戴志敏 陈玉爽 《核动力工程》 EI CAS CSCD 北大核心 2016年第6期33-36,共4页
基于轻水堆最佳估算系统分析程序RELAP/SCDAPSIM/MOD4.0,添加新的FLi Na K熔盐热物性参数和适用于熔盐的对流换热系数,开发了适用于FHR系统的热工水力分析程序RELAP5-FHR。通过FLi Na K高温熔盐实验回路对RELAP5-FHR程序进行实验验证。... 基于轻水堆最佳估算系统分析程序RELAP/SCDAPSIM/MOD4.0,添加新的FLi Na K熔盐热物性参数和适用于熔盐的对流换热系数,开发了适用于FHR系统的热工水力分析程序RELAP5-FHR。通过FLi Na K高温熔盐实验回路对RELAP5-FHR程序进行实验验证。结果表明:RELAP5-FHR程序计算值与实验值吻合较好,验证了程序的适用性。 展开更多
关键词 relap/SCDAPSIM/MOD4.0 FHR FLi NA K实验回路 程序验证
原文传递