Presents a waveguide CO 2 laser with two unequal long channels excited by radio frequency (RF) which has more than 30 laser lines from a long channel of 400 mm with grating, and 3 laser lines from a short channel of 2...Presents a waveguide CO 2 laser with two unequal long channels excited by radio frequency (RF) which has more than 30 laser lines from a long channel of 400 mm with grating, and 3 laser lines from a short channel of 200 mm by PZT.展开更多
Awake monkey fMRI and diffusion MRI combined with conventional neuroscience techniques has the potential to study the structural and functional neural network. The majority of monkey fMRI and diffusion MRI experiments...Awake monkey fMRI and diffusion MRI combined with conventional neuroscience techniques has the potential to study the structural and functional neural network. The majority of monkey fMRI and diffusion MRI experiments are performed with single coils which suffer from severe EPI distortions which limit resolution. By constructing phased array coils for monkey MRI studies, gains in SNR and anatomical accuracy (i.e., reduction of EPI distortions) can be achieved using parallel imaging. The major challenges associated with constructing phased array coils for monkeys are the variation in head size and space constraints. Here, we apply phased array technology to a 4-channel phased array coil capable of improving the resolution and image quality of full brain awake monkey fMRI and diffusion MRI experiments. The phased array coil is that can adapt to different rhesus monkey head sizes (ages 4-8) and fits in the limited space provided by monkey stereotactic equipment and provides SNR gains in primary visual cortex and anatomical accuracy in conjunction with parallel imaging and improves resolution in fMRI experiments by a factor of 2 (1.25 mm to 1.0 mm isotropic) and diffusion MRI experiments by a factor of 4 (1.5 mm to 0.9 mm isotropic).展开更多
This paper presents an RF receiver of zero-Intermediate Frequency(IF) architecture for Cognitive Radio(CR) communication systems.Zero-IF architecture reduce the image reject filter and IF filter,so it is excellent in ...This paper presents an RF receiver of zero-Intermediate Frequency(IF) architecture for Cognitive Radio(CR) communication systems.Zero-IF architecture reduce the image reject filter and IF filter,so it is excellent in low cost,compact volume,and low power dissipation.The receiver employs three digital attenuator and a high gain,high linearity low noise amplifier to achieve wide dynamic range of 70 dB and high receiving sensitivity of-81 dBm.A fully balanced I/Q demodulator and a differential Local Oscillator(LO) chips are used to minimize the negative effects caused by second-order distortion and LO leakage.In order to select an 8 MHz-channel from 14 continuous ones located in UHF band(694-806 MHz) accurately,approach of channel selectivity circuits is proposed.The RF receiver has been designed,fabricated,and test.The measured result shows that the noise figure is 3.4 dB,and the error vector magnitude is 7.5% when the input power is-81 dBm.展开更多
文摘Presents a waveguide CO 2 laser with two unequal long channels excited by radio frequency (RF) which has more than 30 laser lines from a long channel of 400 mm with grating, and 3 laser lines from a short channel of 200 mm by PZT.
文摘Awake monkey fMRI and diffusion MRI combined with conventional neuroscience techniques has the potential to study the structural and functional neural network. The majority of monkey fMRI and diffusion MRI experiments are performed with single coils which suffer from severe EPI distortions which limit resolution. By constructing phased array coils for monkey MRI studies, gains in SNR and anatomical accuracy (i.e., reduction of EPI distortions) can be achieved using parallel imaging. The major challenges associated with constructing phased array coils for monkeys are the variation in head size and space constraints. Here, we apply phased array technology to a 4-channel phased array coil capable of improving the resolution and image quality of full brain awake monkey fMRI and diffusion MRI experiments. The phased array coil is that can adapt to different rhesus monkey head sizes (ages 4-8) and fits in the limited space provided by monkey stereotactic equipment and provides SNR gains in primary visual cortex and anatomical accuracy in conjunction with parallel imaging and improves resolution in fMRI experiments by a factor of 2 (1.25 mm to 1.0 mm isotropic) and diffusion MRI experiments by a factor of 4 (1.5 mm to 0.9 mm isotropic).
基金Supported by the National High-Tech Project (No. 2009AA011801)National Natural Science Foundation of China (No. 60621002)
文摘This paper presents an RF receiver of zero-Intermediate Frequency(IF) architecture for Cognitive Radio(CR) communication systems.Zero-IF architecture reduce the image reject filter and IF filter,so it is excellent in low cost,compact volume,and low power dissipation.The receiver employs three digital attenuator and a high gain,high linearity low noise amplifier to achieve wide dynamic range of 70 dB and high receiving sensitivity of-81 dBm.A fully balanced I/Q demodulator and a differential Local Oscillator(LO) chips are used to minimize the negative effects caused by second-order distortion and LO leakage.In order to select an 8 MHz-channel from 14 continuous ones located in UHF band(694-806 MHz) accurately,approach of channel selectivity circuits is proposed.The RF receiver has been designed,fabricated,and test.The measured result shows that the noise figure is 3.4 dB,and the error vector magnitude is 7.5% when the input power is-81 dBm.