期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Calibration chain design based on integrating sphere transfer radiometer for SI-traceable on-orbit spectral radiometric calibration and its uncertainty analysis 被引量:1
1
作者 赵维宁 方伟 +2 位作者 孙立微 崔立红 王玉鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第9期276-283,共8页
In order to satisfy the requirement of SI-traceable on-orbit absolute radiation calibration transfer with high accuracy for satellite remote sensors,a transfer chain consisting of a fiber coupling monochromator(FBM)... In order to satisfy the requirement of SI-traceable on-orbit absolute radiation calibration transfer with high accuracy for satellite remote sensors,a transfer chain consisting of a fiber coupling monochromator(FBM) and an integrating sphere transfer radiometer(ISTR) was designed in this paper.Depending on the Sun,this chain based on detectors provides precise spectral radiometric calibration and measurement to spectrometers in the reflective solar band(RSB) covering 300–2500 nm with a spectral bandwidth of 0.5–6 nm.It shortens the traditional chain based on lamp source and reduces the calibration uncertainty from 5% to 0.5% by using the cryogenic radiometer in space as a radiometric benchmark and trap detectors as secondary standard.This paper also gives a detailed uncertainty budget with reasonable distribution of each impact factor,including the weak spectral signal measurement with uncertainty of 0.28%.According to the peculiar design and comprehensive uncertainty analysis,it illustrates that the spectral radiance measurement uncertainty of the ISTR system can reach to 0.48%.The result satisfies the requirements of SI-traceable on-orbit calibration and has wider significance for expanding the application of the remote sensing data with high-quality. 展开更多
关键词 SI-traceable calibration on-orbit high-accuracy transfer chain integrating sphere transfer radiometer uncertainty analysis
下载PDF
Research on sea surface temperature retrieval by the one-dimensional synthetic aperture microwave radiometer, 1D-SAMR 被引量:2
2
作者 Weihua Ai Mengyan Feng +1 位作者 Guanyu Chen Wen Lu 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2020年第5期115-122,共8页
Due to the low spatial resolution of sea surface temperature(T_S)retrieval by real aperture microwave radiometers,in this study,an iterative retrieval method that minimizes the differences between brightness temperatu... Due to the low spatial resolution of sea surface temperature(T_S)retrieval by real aperture microwave radiometers,in this study,an iterative retrieval method that minimizes the differences between brightness temperature(T_B)measured and modeled was used to retrieve sea surface temperature with a one-dimensional synthetic aperture microwave radiometer,temporarily named 1 D-SAMR.Regarding the configuration of the radiometer,an angular resolution of 0.43°was reached by theoretical calculation.Experiments on sea surface temperature retrieval were carried out with ideal parameters;the results show that the main factors affecting the retrieval accuracy of sea surface temperature are the accuracy of radiometer calibration and the precision of auxiliary geophysical parameters.In the case of no auxiliary parameter errors,the greatest error in retrieved sea surface temperature is obtained at low T_S scene(i.e.,0.7106 K for the incidence angle of 35°under the radiometer calibration accuracy of0.5 K).While errors on auxiliary parameters are assumed to follow a Gaussian distribution,the greatest error on retrieved sea surface temperature was 1.3305 K at an incidence angle of 65°in poorly known sea surface wind speed(W)(the error on W of 1.0 m/s)over high W scene,for the radiometer calibration accuracy of 0.5 K. 展开更多
关键词 sea surface temperature synthetic aperture microwave radiometer retrieval accuracy radiometer calibration accuracy auxiliary parameter errors high spatial resolution
下载PDF
Autonomous vicarious calibration based on automated test-site radiometer 被引量:1
3
作者 邱刚刚 李新 +2 位作者 郑小兵 闫静 孙彦港 《Chinese Optics Letters》 SCIE EI CAS CSCD 2016年第12期70-74,共5页
We employ the in-site automated observation radiometric calibration(AORC) approach to perform vicarious calibration, which does not require the manual efforts of a field team to measure the surface conditions. By us... We employ the in-site automated observation radiometric calibration(AORC) approach to perform vicarious calibration, which does not require the manual efforts of a field team to measure the surface conditions. By using an automated test-site radiometer(ATR), the surface radiance at any moment in time can be obtained. This Letter describes the AORC approach and makes use of data to compute top-of-atmosphere radiance and compare it to measurements from the Moderate Resolution Imaging Spectroradiometer. The result shows that the relative deviation is less than 5% and the uncertainty is less than 6.2%, which indicates that the in-site AORC maintains an accuracy level on par with traditional calibration. 展开更多
关键词 calibration radiometer automated manual compute viewing reflectance deviation correction directional
原文传递
上一页 1 下一页 到第