Accurate measurements of the radon exhalation rate help identify and evaluate radon risk regions in the environment.Among these measurement methods,the closed-loop method is frequently used.However,traditional experim...Accurate measurements of the radon exhalation rate help identify and evaluate radon risk regions in the environment.Among these measurement methods,the closed-loop method is frequently used.However,traditional experiments are insufficient or cannot analyze the radon migration and exhalation patterns at the gas–solid interface in the accumulation chamber.The CFD-based technique was applied to predict the radon concentration distribution in a limited space,allowing radon accumulation and exhalation inside the chamber intuitively and visually.In this study,three radon exhalation rates were defined,and two structural ventilation tubes were designed for the chamber.The consistency of the simulated results with the variation in the radon exhalation rate in a previous experiment or analytical solution was verified.The effects of the vent tube structure and flow rate on the radon uniformity in the chamber;permeability,insertion depth,and flow rate on the radon exhalation rate and the effective diffusion coefficient on back-diffusion were investigated.Based on the results,increasing the inser-tion depth from 1 to 5 cm decreased the effective decay constant by 19.55%,whereas the curve-fitted radon exhalation rate decreased(lower than the initial value)as the deviation from the initial value increased by approximately 7%.Increasing the effective diffusion coefficient from 2.77×10^(-7) to 7.77×10^(-6) m^(2) s^(-1) made the deviation expand from 2.14 to 15.96%.The conclusion is that an increased insertion depth helps reduce leakage in the chamber,subject to notable back-diffusion,and that the closed-loop method is reasonably used for porous media with a low effective diffusion coefficient in view of the back-diffusion effect.The CFD-based simulation is expected to provide guidance for the optimization of the radon exhalation rate measurement method and,thus,the accurate measurement of the radon exhalation rate.展开更多
Objective This study aimed to efficiently reduce the release of radon from water bodies to protect the environment.Methods Based on the sizes of the experimental setup and modular float,computational fluid dynamics(CF...Objective This study aimed to efficiently reduce the release of radon from water bodies to protect the environment.Methods Based on the sizes of the experimental setup and modular float,computational fluid dynamics(CFD)was used to assess the impact of the area coverage rate,immersion depth,diffusion coefficient,and radon transfer velocity at the gas–liquid interface on radon migration and exhalation of radon-containing water.Based on the numerical simulation results,an estimation model for the radon retardation rate was constructed.The effectiveness of the CFD simulation was evaluated by comparing the experimental and simulated variation values of the radon retardation rate with the coverage area rates.Results The effect of radon transfer velocity on radon retardation in water bodies was minor and insignificant according to the appropriate value;therefore,an estimation model of the radon retardation rate of the coverage of a radon-containing water body was constructed using the synergistic impacts of three factors:area coverage rate,immersion depth,and diffusion coefficient.The deviation between the experimental and simulated results was<4.3%.Conclusion Based on the numerical simulation conditions,an estimation model of the radon retardation rate of covering floats in water bodies under the synergistic effect of multiple factors was obtained,which provides a reference for designing covering floats for radon retardation in radoncontaining water.展开更多
The objective of our study is to evaluate the concentration of radon (<sup>86</sup>Rn) inside houses in the town of Koudougou in order to estimate its impact on the health of the population. Indeed, when u...The objective of our study is to evaluate the concentration of radon (<sup>86</sup>Rn) inside houses in the town of Koudougou in order to estimate its impact on the health of the population. Indeed, when uranium-rich minerals are found near the surface of the ground, radon concentrations can reach tens of becquerels per cubic meter in enclosed spaces. Given the nature of the geological base of Burkina Faso, this situation is quite probable and certain places that are sometimes poorly ventilated (house, school, office, etc.) can have radon levels high enough to constitute a health problem for occupants. Thus, twenty-four (24) sample houses were identified. In each house, the Corentium digital detector was between 0.8 m and 2 m for at least one week in a place where the occupants estimate that they spend more time of time and measure the concentration of radon in the long term and short term. The recorded data allowed us to determine the Absorbed Dose and the Annual Effective Dose of radon gas for each house in order to estimate the Risk of Cancer and the probable Number of Cases of Lung Cancer per million inhabitants. Thus, the results indicate that the long-term radon concentration varies between 6 Bq/m<sup>3</sup> and 285 Bq/m<sup>3</sup> respectively in houses 11 and 4 compared to 1 Bq/m<sup>3</sup> to 208 Bq/m<sup>3</sup> in the short term in the same houses. Also, in the long term, in control houses 1, 3 and 4, the radon level is above the recommended threshold interval. For the short term, these are houses 1, 3, 4 and 17 respectively with 110 Bq/m<sup>3</sup>, 142 Bq/m<sup>3</sup>, 208 Bq/m<sup>3</sup> and 105 Bq/m<sup>3</sup>. As for the long-term and short-term effective doses, only houses 1, 3, 4, 17 and 24 have values between 3 - 10 Sv/year. The estimation of the relative risk of lung cancer gives values relatively close to unity and between 1.006 and 1.142 with an average of 1.035 and that of the Number of Lung Cancer Cases per million inhabitants gives values between 8 and 166 with an average of 42. Thus, we can conclude that with the exception of houses 1, 3, 4 and 17, the radon concentrations are relatively low in the twenty-four control houses in the city of Koudougou. The lifestyle of the populations can well explain this situation when we know that people are in the habit of always leaving doors and windows open, especially when they are not sleeping. We can therefore say that the risk of population exposure to radon gas is relatively low in the town of Koudougou.展开更多
We solve the Riemann problems for isentropic compressible Euler equations of polytropic gases in the class of Radon measures,and the solutions admit the concentration of mass.It is found that under the requirement of ...We solve the Riemann problems for isentropic compressible Euler equations of polytropic gases in the class of Radon measures,and the solutions admit the concentration of mass.It is found that under the requirement of satisfying the over-compressing entropy condition:(i)there is a unique delta shock solution,corresponding to the case that has two strong classical Lax shocks;(ii)for the initial data that the classical Riemann solution contains a shock wave and a rarefaction wave,or two shocks with one being weak,there are infinitely many solutions,each consists of a delta shock and a rarefaction wave;(iii)there are no delta shocks for the case that the classical entropy weak solutions consist only of rarefaction waves.These solutions are self-similar.Furthermore,for the generalized Riemann problem with mass concentrated initially at the discontinuous point of initial data,there always exists a unique delta shock for at least a short time.It could be prolonged to a global solution.Not all the solutions are self-similar due to the initial velocity of the concentrated point-mass(particle).Whether the delta shock solutions constructed satisfy the over-compressing entropy condition is clarified.This is the first result on the construction of singular measure solutions to the compressible Euler system of polytropic gases,that is strictly hyperbolic,and whose characteristics are both genuinely nonlinear.We also discuss possible physical interpretations and applications of these new solutions.展开更多
Radon(Rn)is a naturally occurring radioactive inert gas in nature,and^(222)Rn has been routinely used as a powerful tracer in various aquatic environmental research on timescales of hours to days,such as submarine gro...Radon(Rn)is a naturally occurring radioactive inert gas in nature,and^(222)Rn has been routinely used as a powerful tracer in various aquatic environmental research on timescales of hours to days,such as submarine groundwater discharge.Here we developed a new approach to measure^(222)Rn in discrete water samples with a wide range of^(222)Rn concentrations using a Pulsed Ionization Chamber(PIC)Radon Detector.The sensitivity of the new PIC system is evaluated at 6.06 counts per minute for 1 Bq/L when a 500 mL water sample volume is used.A robust logarithmic correlation between sample volumes,ranging from 250 mL to 5000 mL,and system sensitivity obtained in this study strongly suggests that this approach is suitable for measuring radon concentration levels in various natural waters.Compared to the currently available methods for measuring radon in grab samples,the PIC system is cheaper,easier to operate and does not require extra accessories(e.g.,drying tubes etc.)to maintain stable measurements throughout the counting procedure.展开更多
Environmental radon emanates from the exhalation and release of soil,rocks,and building materials.Environmental radon contamination tracing and radon pollution prevention and control require the measurement of the rad...Environmental radon emanates from the exhalation and release of soil,rocks,and building materials.Environmental radon contamination tracing and radon pollution prevention and control require the measurement of the radon exhalation rate on media surfaces.Reliable measurements of the radon exhalation rate cannot be achieved without regular calibration of the measuring instrument with a high-performance reference device.In this study,a reference device for the calibration of radon exhalation rate measuring instruments was developed using a diffusion solid radon source with a high and stable radon emanation coefficient,an integrated diffusion component composed of a plasterboard and a high-density wooden board,an air pressure balance device,a radon accumulation chamber,and a support structure.The uniformity and stability of the reference device were evaluated using the activated carbon-γspectrum and open-loop method,respectively,to measure the radon exhalation rate.The reference device achieved different radon exhalation rates by using different activities of diffusion solid radon sources.Nineteen measurement points were regularly selected on the radon exhalation surface of the reference device,and the uniformity of the radon exhalation rate exceeded 5%.The short-term stability of the reference device was better than 5%under different environmental conditions and was almost unaffected by the ambient air pressure,environmental temperature,and relative humidity.展开更多
Radon is recognized as a powerful tracer of certain geophysical processes in marine and aquatic environments.In the past few decades,the instruments and methods for measuring radon concentration in water have been dev...Radon is recognized as a powerful tracer of certain geophysical processes in marine and aquatic environments.In the past few decades,the instruments and methods for measuring radon concentration in water have been developed to some extent but still lack underwater in-situ measurements.Here we present an in-situ detection equipment for radon-in-water(pulsed ionization chamber(PIC)-radon)to measure dissolved radon in ocean and groundwater settings.The equipment has been successfully deployed in the Jiaozhou Bay in July 2022 and has achieved 14 d of unattended underwater in-situ observation.Then it was successfully placed in a groundwater monitoring well in the Laizhou Bay in November 2022 and monitored radon activities for over 30 d.The results showed that this instrument had a good indication of submarine groundwater discharge.The PIC-radon detector takes advantage of smaller size,lower power consumption,and is barely influenced by humidity,making it particularly suitable for long-term in-situ measurement,especially in harsh environments with limited human care or deployment spaces.展开更多
In the digital world,a wide range of handwritten and printed documents should be converted to digital format using a variety of tools,including mobile phones and scanners.Unfortunately,this is not an optimal procedure...In the digital world,a wide range of handwritten and printed documents should be converted to digital format using a variety of tools,including mobile phones and scanners.Unfortunately,this is not an optimal procedure,and the entire document image might be degraded.Imperfect conversion effects due to noise,motion blur,and skew distortion can lead to significant impact on the accuracy and effectiveness of document image segmentation and analysis in Optical Character Recognition(OCR)systems.In Document Image Analysis Systems(DIAS),skew estimation of images is a crucial step.In this paper,a novel,fast,and reliable skew detection algorithm based on the Radon Transform and Curve Length Fitness Function(CLF),so-called Radon CLF,was proposed.The Radon CLF model aims to take advantage of the properties of Radon spaces.The Radon CLF explores the dominating angle more effectively for a 1D signal than it does for a 2D input image due to an innovative fitness function formulation for a projected signal of the Radon space.Several significant performance indicators,including Mean Square Error(MSE),Mean Absolute Error(MAE),Peak Signal-to-Noise Ratio(PSNR),Structural Similarity Measure(SSIM),Accuracy,and run-time,were taken into consideration when assessing the performance of our model.In addition,a new dataset named DSI5000 was constructed to assess the accuracy of the CLF model.Both two-dimensional image signal and the Radon space have been used in our simulations to compare the noise effect.Obtained results show that the proposed method is more effective than other approaches already in use,with an accuracy of roughly 99.87%and a run-time of 0.048(s).The introduced model is far more accurate and timeefficient than current approaches in detecting image skew.展开更多
基金funded by the Basic Research and Strategic Reserve Technology Research Fund Project of CNPC (2019D-500803)the national oil and gas project (2016zx05007-006)。
基金This work was supported by the National Natural Science Foundation of China(No.11575080)the National Natural Science Foundation of Hunan Province,China(No.2022JJ30482)the Hunan Provincial Innovation Foundation for Postgraduates(No.QL20220206).
文摘Accurate measurements of the radon exhalation rate help identify and evaluate radon risk regions in the environment.Among these measurement methods,the closed-loop method is frequently used.However,traditional experiments are insufficient or cannot analyze the radon migration and exhalation patterns at the gas–solid interface in the accumulation chamber.The CFD-based technique was applied to predict the radon concentration distribution in a limited space,allowing radon accumulation and exhalation inside the chamber intuitively and visually.In this study,three radon exhalation rates were defined,and two structural ventilation tubes were designed for the chamber.The consistency of the simulated results with the variation in the radon exhalation rate in a previous experiment or analytical solution was verified.The effects of the vent tube structure and flow rate on the radon uniformity in the chamber;permeability,insertion depth,and flow rate on the radon exhalation rate and the effective diffusion coefficient on back-diffusion were investigated.Based on the results,increasing the inser-tion depth from 1 to 5 cm decreased the effective decay constant by 19.55%,whereas the curve-fitted radon exhalation rate decreased(lower than the initial value)as the deviation from the initial value increased by approximately 7%.Increasing the effective diffusion coefficient from 2.77×10^(-7) to 7.77×10^(-6) m^(2) s^(-1) made the deviation expand from 2.14 to 15.96%.The conclusion is that an increased insertion depth helps reduce leakage in the chamber,subject to notable back-diffusion,and that the closed-loop method is reasonably used for porous media with a low effective diffusion coefficient in view of the back-diffusion effect.The CFD-based simulation is expected to provide guidance for the optimization of the radon exhalation rate measurement method and,thus,the accurate measurement of the radon exhalation rate.
基金supported by a grant from the National Natural Science Foundation of China(Grant nos.31770907,31640022)the National Natural Science Foundation of China(Grant No.11575080)the Natural Science Foundation of Hunan Province,China(Grant No.2022JJ30482).
文摘Objective This study aimed to efficiently reduce the release of radon from water bodies to protect the environment.Methods Based on the sizes of the experimental setup and modular float,computational fluid dynamics(CFD)was used to assess the impact of the area coverage rate,immersion depth,diffusion coefficient,and radon transfer velocity at the gas–liquid interface on radon migration and exhalation of radon-containing water.Based on the numerical simulation results,an estimation model for the radon retardation rate was constructed.The effectiveness of the CFD simulation was evaluated by comparing the experimental and simulated variation values of the radon retardation rate with the coverage area rates.Results The effect of radon transfer velocity on radon retardation in water bodies was minor and insignificant according to the appropriate value;therefore,an estimation model of the radon retardation rate of the coverage of a radon-containing water body was constructed using the synergistic impacts of three factors:area coverage rate,immersion depth,and diffusion coefficient.The deviation between the experimental and simulated results was<4.3%.Conclusion Based on the numerical simulation conditions,an estimation model of the radon retardation rate of covering floats in water bodies under the synergistic effect of multiple factors was obtained,which provides a reference for designing covering floats for radon retardation in radoncontaining water.
文摘The objective of our study is to evaluate the concentration of radon (<sup>86</sup>Rn) inside houses in the town of Koudougou in order to estimate its impact on the health of the population. Indeed, when uranium-rich minerals are found near the surface of the ground, radon concentrations can reach tens of becquerels per cubic meter in enclosed spaces. Given the nature of the geological base of Burkina Faso, this situation is quite probable and certain places that are sometimes poorly ventilated (house, school, office, etc.) can have radon levels high enough to constitute a health problem for occupants. Thus, twenty-four (24) sample houses were identified. In each house, the Corentium digital detector was between 0.8 m and 2 m for at least one week in a place where the occupants estimate that they spend more time of time and measure the concentration of radon in the long term and short term. The recorded data allowed us to determine the Absorbed Dose and the Annual Effective Dose of radon gas for each house in order to estimate the Risk of Cancer and the probable Number of Cases of Lung Cancer per million inhabitants. Thus, the results indicate that the long-term radon concentration varies between 6 Bq/m<sup>3</sup> and 285 Bq/m<sup>3</sup> respectively in houses 11 and 4 compared to 1 Bq/m<sup>3</sup> to 208 Bq/m<sup>3</sup> in the short term in the same houses. Also, in the long term, in control houses 1, 3 and 4, the radon level is above the recommended threshold interval. For the short term, these are houses 1, 3, 4 and 17 respectively with 110 Bq/m<sup>3</sup>, 142 Bq/m<sup>3</sup>, 208 Bq/m<sup>3</sup> and 105 Bq/m<sup>3</sup>. As for the long-term and short-term effective doses, only houses 1, 3, 4, 17 and 24 have values between 3 - 10 Sv/year. The estimation of the relative risk of lung cancer gives values relatively close to unity and between 1.006 and 1.142 with an average of 1.035 and that of the Number of Lung Cancer Cases per million inhabitants gives values between 8 and 166 with an average of 42. Thus, we can conclude that with the exception of houses 1, 3, 4 and 17, the radon concentrations are relatively low in the twenty-four control houses in the city of Koudougou. The lifestyle of the populations can well explain this situation when we know that people are in the habit of always leaving doors and windows open, especially when they are not sleeping. We can therefore say that the risk of population exposure to radon gas is relatively low in the town of Koudougou.
基金supported by the National Natural Science Foundation of China under Grants No.11871218,No.12071298the Science and Technology Commission of Shanghai Municipality under Grant No.18dz2271000.
文摘We solve the Riemann problems for isentropic compressible Euler equations of polytropic gases in the class of Radon measures,and the solutions admit the concentration of mass.It is found that under the requirement of satisfying the over-compressing entropy condition:(i)there is a unique delta shock solution,corresponding to the case that has two strong classical Lax shocks;(ii)for the initial data that the classical Riemann solution contains a shock wave and a rarefaction wave,or two shocks with one being weak,there are infinitely many solutions,each consists of a delta shock and a rarefaction wave;(iii)there are no delta shocks for the case that the classical entropy weak solutions consist only of rarefaction waves.These solutions are self-similar.Furthermore,for the generalized Riemann problem with mass concentrated initially at the discontinuous point of initial data,there always exists a unique delta shock for at least a short time.It could be prolonged to a global solution.Not all the solutions are self-similar due to the initial velocity of the concentrated point-mass(particle).Whether the delta shock solutions constructed satisfy the over-compressing entropy condition is clarified.This is the first result on the construction of singular measure solutions to the compressible Euler system of polytropic gases,that is strictly hyperbolic,and whose characteristics are both genuinely nonlinear.We also discuss possible physical interpretations and applications of these new solutions.
基金The National Natural Science Foundation of China under contract Nos 42130410,41876075 and U1906210the Fundamental Research Funds for the Central Universities under contract No.201962003.
文摘Radon(Rn)is a naturally occurring radioactive inert gas in nature,and^(222)Rn has been routinely used as a powerful tracer in various aquatic environmental research on timescales of hours to days,such as submarine groundwater discharge.Here we developed a new approach to measure^(222)Rn in discrete water samples with a wide range of^(222)Rn concentrations using a Pulsed Ionization Chamber(PIC)Radon Detector.The sensitivity of the new PIC system is evaluated at 6.06 counts per minute for 1 Bq/L when a 500 mL water sample volume is used.A robust logarithmic correlation between sample volumes,ranging from 250 mL to 5000 mL,and system sensitivity obtained in this study strongly suggests that this approach is suitable for measuring radon concentration levels in various natural waters.Compared to the currently available methods for measuring radon in grab samples,the PIC system is cheaper,easier to operate and does not require extra accessories(e.g.,drying tubes etc.)to maintain stable measurements throughout the counting procedure.
基金supported by the National Natural Science Foundation of China(No.11875165).
文摘Environmental radon emanates from the exhalation and release of soil,rocks,and building materials.Environmental radon contamination tracing and radon pollution prevention and control require the measurement of the radon exhalation rate on media surfaces.Reliable measurements of the radon exhalation rate cannot be achieved without regular calibration of the measuring instrument with a high-performance reference device.In this study,a reference device for the calibration of radon exhalation rate measuring instruments was developed using a diffusion solid radon source with a high and stable radon emanation coefficient,an integrated diffusion component composed of a plasterboard and a high-density wooden board,an air pressure balance device,a radon accumulation chamber,and a support structure.The uniformity and stability of the reference device were evaluated using the activated carbon-γspectrum and open-loop method,respectively,to measure the radon exhalation rate.The reference device achieved different radon exhalation rates by using different activities of diffusion solid radon sources.Nineteen measurement points were regularly selected on the radon exhalation surface of the reference device,and the uniformity of the radon exhalation rate exceeded 5%.The short-term stability of the reference device was better than 5%under different environmental conditions and was almost unaffected by the ambient air pressure,environmental temperature,and relative humidity.
基金The National Natural Science Foundation of China under contract Nos U22A20580 and 42130410the Fundamental Research Funds for the Central Universities under contract No.202341002the Pilot Project for the Integration of Science,Education,and Industry under contract No.2022PY069.
文摘Radon is recognized as a powerful tracer of certain geophysical processes in marine and aquatic environments.In the past few decades,the instruments and methods for measuring radon concentration in water have been developed to some extent but still lack underwater in-situ measurements.Here we present an in-situ detection equipment for radon-in-water(pulsed ionization chamber(PIC)-radon)to measure dissolved radon in ocean and groundwater settings.The equipment has been successfully deployed in the Jiaozhou Bay in July 2022 and has achieved 14 d of unattended underwater in-situ observation.Then it was successfully placed in a groundwater monitoring well in the Laizhou Bay in November 2022 and monitored radon activities for over 30 d.The results showed that this instrument had a good indication of submarine groundwater discharge.The PIC-radon detector takes advantage of smaller size,lower power consumption,and is barely influenced by humidity,making it particularly suitable for long-term in-situ measurement,especially in harsh environments with limited human care or deployment spaces.
文摘In the digital world,a wide range of handwritten and printed documents should be converted to digital format using a variety of tools,including mobile phones and scanners.Unfortunately,this is not an optimal procedure,and the entire document image might be degraded.Imperfect conversion effects due to noise,motion blur,and skew distortion can lead to significant impact on the accuracy and effectiveness of document image segmentation and analysis in Optical Character Recognition(OCR)systems.In Document Image Analysis Systems(DIAS),skew estimation of images is a crucial step.In this paper,a novel,fast,and reliable skew detection algorithm based on the Radon Transform and Curve Length Fitness Function(CLF),so-called Radon CLF,was proposed.The Radon CLF model aims to take advantage of the properties of Radon spaces.The Radon CLF explores the dominating angle more effectively for a 1D signal than it does for a 2D input image due to an innovative fitness function formulation for a projected signal of the Radon space.Several significant performance indicators,including Mean Square Error(MSE),Mean Absolute Error(MAE),Peak Signal-to-Noise Ratio(PSNR),Structural Similarity Measure(SSIM),Accuracy,and run-time,were taken into consideration when assessing the performance of our model.In addition,a new dataset named DSI5000 was constructed to assess the accuracy of the CLF model.Both two-dimensional image signal and the Radon space have been used in our simulations to compare the noise effect.Obtained results show that the proposed method is more effective than other approaches already in use,with an accuracy of roughly 99.87%and a run-time of 0.048(s).The introduced model is far more accurate and timeefficient than current approaches in detecting image skew.