期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
PRODUCTION OF HIGHLY GRAPHITIZED MULTIWALlED CARBON ANOTUBES
1
作者 X.L.Zhao1) ,T.L.Guo2) ,M.Ohkohchi3) ,T.Okazaki3) ,S.Iijima and Y.Ando3) 1) Japan Science and Technology Corporation ,Department of Physics, Meijo University ,Shiogamaguchi1 501 ,Tempaku ku , Nagoya 468 8502 ,Japan 2) Scientific Research Department,Sh 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1999年第4期345-352,共8页
Multiwalled carbon nanotubes ( MWNTs) were prepared by DCarc dischargein hydrogen gas, and werethermally purified byinfrared radiation in air. The morphology of pristineand purified MWNTs was observed by scanning ele... Multiwalled carbon nanotubes ( MWNTs) were prepared by DCarc dischargein hydrogen gas, and werethermally purified byinfrared radiation in air. The morphology of pristineand purified MWNTs was observed by scanning electron microscope ( SEM) , and the crys tallinestructureand perfection wereinvestigated by high resolution transmission electron mi croscope( HRTEM) and Raman spectrometer. Itcameto the conclusion thatthese MWNTs possessed a high degreeof graphitization and very narrow centralchannel(about1 0 nm indiameter) , giving risetotheappearanceof breathing modesfor MWNTs. 展开更多
关键词 multiwalled carbon nanotubes hydrogen arc SEM HRTEM raman spectrometer
下载PDF
Raman spectroscopic detection using a two-dimensional echelle spectrometer
2
作者 张锐 任文艺 +3 位作者 王鹤 王元元 林桢坤 韩孜琦 《Optoelectronics Letters》 EI 2021年第11期641-645,共5页
In order to meet the high-resolution and wide spectrum range of the backscattering Raman system, this paper designs and builds a Raman test system based on the echelle spectrometer. In the optical splitting system, co... In order to meet the high-resolution and wide spectrum range of the backscattering Raman system, this paper designs and builds a Raman test system based on the echelle spectrometer. In the optical splitting system, compared with the ordinary planar grating spectrometer, the use of the echelle improves the resolution of the system without increasing the volume of the system. The use of intensified charge-coupled device(ICCD) in the detection system improves the signal-to-noise ratio(SNR) and the detection limit of weak spectrum. Finally, the Raman system was spectrally calibrated. The broadband backscattering Raman experimental results are given and discussed. The experimental results show that the system has an excellent application prospect for broadband and high-resolution Raman spectrum measurement. 展开更多
关键词 SNR raman spectroscopic detection using a two-dimensional echelle spectrometer
原文传递