期刊文献+
共找到726篇文章
< 1 2 37 >
每页显示 20 50 100
Measurement of cervical range of motion using smartphone compass in the healthy people:a cross-sectional pilot study
1
作者 Jun-Qing Zhong Xi Zhao +2 位作者 Jing-Yao Wang Dan Meng Ze-Yu Zhong 《TMR Non-Drug Therapy》 2023年第1期1-7,共7页
Objective:This study evaluates the reliability of smartphone compass software in measuring the cervical range of motion in healthy people.Methods:We selected 40 healthy intern college students from Tianjin Hospital fr... Objective:This study evaluates the reliability of smartphone compass software in measuring the cervical range of motion in healthy people.Methods:We selected 40 healthy intern college students from Tianjin Hospital from June to August 2022 to participate in this study.Two physiotherapists used a smartphone(iPhone 11256 Gb(model A2223))compass software to measure six directions of motion of the cervical spine in 40 subjects in a total of 3 rounds each.The intraclass correlation coefficient was used to compare the reliability intra-group,and the Pearson correlation coefficient was also used to compare the correlation between groups,with P<0.05 being statistically significant.Results:The intraclass correlation coefficient showed good reliability(>0.5)in cervical range of motion(CROM),especially in cervical flexion and right rotation(>0.9).In the correlation comparison between the two groups,the Spearman comparison was used,and the six directions of the cervical spine were significantly correlated(P<0.05).Conclusion:The built-in compass software in smartphones has good reliability in measuring CROM in healthy people. 展开更多
关键词 cervical range of motion SMARTPHONE COMPASS intraclass correlation coefficient
下载PDF
Radiographic Circularity of Capitellum and Its Relation to the Range of Motion
2
作者 Islam Mubark Neil Ashwood +3 位作者 Amr Abouelela Hiran Patel Hamzah Khan Quentin Fogg 《Open Journal of Orthopedics》 2023年第5期205-212,共8页
Background: The shape of the capitellum has been traditionally described in anatomy books as part of a sphere. Alteration in the capitellar morphology following pathologies such as fractures, osteochondrosis, and dege... Background: The shape of the capitellum has been traditionally described in anatomy books as part of a sphere. Alteration in the capitellar morphology following pathologies such as fractures, osteochondrosis, and degenerative arthritis has been associated with less optimum functional results. Aim: To define the relationship between the sphericity of the capitellar morphology as measured on trauma series plain radiographs and the elbow range of motion. Methods: 40 patients were included in the study. All patients recruited from the upper limb clinics presented with non-elbow joint-related complaints. The elbow range of motion was measured using a standardized technique. Digital anteroposterior and lateral radiographs of patients’ elbows were used to measure capitellar circularity using the ImageJ processing program and circularity calculation equation. Correlation analyses were conducted between the degree of capitellar sphericity and elbow range of motion. Results: The results of measurements from the anteroposterior radiographs showed a positive correlation between increased circularity and an increase in the range of flexion, pronation, and supination. The range of extension decreased with the increased circularity of the capitellum. This trend was repeated with measures of lateral radiographs but was statistically not significant. Conclusion: Native capitellar circularity has an impact on the elbow range of motion. This should be put into consideration when dealing with pathologies that affect capitellar morphology. 展开更多
关键词 CAPITELLUM CIRCULARITY ANATOMY range of motion Elbow joint
下载PDF
Multilevel Anterior Cervical Decompression and Fusion: Cervical Range of Motion and Clinical Outcomes
3
作者 Ahmed Hosameldin Abdelrahman Senosi Mostafa Abdel-Latif 《Open Journal of Modern Neurosurgery》 2022年第4期181-196,共16页
Background: Multiple level anterior cervical discectomy and fusion (ACDF) is indicated for those who suffer from multilevel stenosis or compression of the spinal canal. It was reported that this intervention would unf... Background: Multiple level anterior cervical discectomy and fusion (ACDF) is indicated for those who suffer from multilevel stenosis or compression of the spinal canal. It was reported that this intervention would unfortunately lead to a loss of normal cervical range of motion (CROM). Although, fewer studies have demonstrated the exact impact of the procedure on CROM. In our study, short and midterm postoperative CROM was described. Methods: Ninety patients who underwent ACDF were followed up postoperatively for at least 3 months. Active CROM was measured in all patients preoperatively and in postoperative follow-ups by cervical spine X-rays in lateral dynamic view using Cobb’s angle method. Results: Unfortunately, postoperative CROM was significantly diminished. At the short-term (3 months) follow-up there was a great limitation in CROM. While an obvious increase in CROM at the midterm (6 months) follow-up was observed in flexion especially. The reduction in global ROM (calculated as preoperative global ROM – 6 months postoperative ROM) was 4.1 and the reduction rate (calculated as reduction ROM divided by preoperative ROM) was 9.5%. The recovery ROM (calculated as 6 months postoperative ROM – 1 month postoperative ROM) was 8.2. The recovery rate (calculated as recovery ROM divided by 1 month postoperative ROM) was 26.5%. Conclusion: Active CROM following multiple level ACDF was obviously diminished. The most affected motion after surgery was flexion. It was noticed that at the short-term follow-up CROM would be more limited while after further follow up CROM was obviously improved even in neck flexion motion. 展开更多
关键词 MULTILEVEL Anterior cervical Discectomy FUSION cervical range of motion
下载PDF
Electrical Stimulation in Addition to Passive Exercise Has a Small Effect on Spasticity and Range of Motion in Bedridden Elderly Patients: A Pilot Randomized Crossover Study
4
作者 Hideki Kataoka Shunpei Nakashima +7 位作者 Hideki Aoki Kyo Goto Junichiro Yamashita Yuichiro Honda Yasutaka Kondo Tatsuya Hirase Junya Sakamoto Minoru Okita 《Health》 2019年第8期1072-1086,共15页
Purpose: Belt electrode skeletal muscle electrical stimulation (B-SES) can stimulate large portions of muscles including deep sites without localisation of the stimulation area. The purpose of this study is to investi... Purpose: Belt electrode skeletal muscle electrical stimulation (B-SES) can stimulate large portions of muscles including deep sites without localisation of the stimulation area. The purpose of this study is to investigate both immediate treatment effects of B-SES and long-term treatment effects of B-SES with passive exercise on range of motion (ROM) and muscle tone of lower extremities in bedridden elderly patients. Methods: Outcome measures before and after B-SES treatment alone (4 Hz, 20 min, both lower extremities) were examined for the immediate effect. Outcome measures were: ROM and Modified Ashworth scale (MAS) of hip flexion and adduction;knee flexion and extension;and knee joint distance at position of flexion abduction in hip (distance of knee). A randomized crossover trial was conducted to examine the long-term effect of adding B-SES to passive exercise on ROM and MAS. Results and Discussion: The immediate effect study had 18 patients. ROM and MAS of 4 joint angles in 2 joints and distance of knee significantly improved after B-SES treatment. The long-term effect study had 11 patients. Friedman test revealed ROM and MAS of 4 joint angles in 2 joints and distance of knee significantly improved during B-SES intervention but not control intervention. B-SES in addition to passive stretch has a more statistically significant effect on contracture and spasticity in large portions of the lower extremities of bedridden elderly patients than passive stretching alone. Conclusions: We consider B-SES a useful tool to improve the ROM in lower extremities of bedridden patients. 展开更多
关键词 BEDRIDDEN Patients Belt Electrode SKELETAL MUSCLE Electrical Stimulation Lower EXTREMITY MUSCLE Tone RESTRICTION of range of joint motion
下载PDF
Obesity Effect on Children Hip and Knee Range of Motion
5
作者 Silvia Maria Amado Joao1] Maira Nomura Nishizaki1] +2 位作者 Cynthia Hitomi Yamamoto1] Vera Lucia Perino Barbosa1] Juliana Ferreira Sauer1] 《International Journal of Clinical Medicine》 2014年第9期490-497,共8页
The aim of this study was to characterize the obesity effect on children knee and hip joint range of motion. A randomized controlled trial was performed with goniometry evaluation for hip flexion, extension, abduction... The aim of this study was to characterize the obesity effect on children knee and hip joint range of motion. A randomized controlled trial was performed with goniometry evaluation for hip flexion, extension, abduction, adduction, external and internal rotation, and knee flexion in fifty male children (20 obese and 30 non obese), with age ranging from 6 to 12 years old. The obesity effect was found to be non-uniform across the joint range of motion. In the obesity group, a statistically significant reduction in the range of motion of hip flexion and adduction, and knee flexion was observed;and also an increase in external rotation in the hip was observed. Conclusion: Obese and overweight children present alterations in hip and knee joints mobility when compared to eutrophic children. The obesity/overweight associated with factors previously described in the literature, such as joint overload, postural deviation and sedentariness may influence the musculoskeletal development and, consequently, the motor function. 展开更多
关键词 OBESITY CHILDREN Body joint motion range of motion
下载PDF
Clinical and radiological outcomes of dynamic cervical implant arthroplasty:A 5-year follow-up
6
作者 Li Zou Xin Rong +1 位作者 Xi-Jiao Liu Hao Liu 《World Journal of Clinical Cases》 SCIE 2021年第16期3869-3879,共11页
BACKGROUND Dynamic cervical implant(DCI)stabilization has been reported to have satisfactory clinical and radiological results with short-and mid-term follow-up in the treatment of cervical degenerative disc disease.H... BACKGROUND Dynamic cervical implant(DCI)stabilization has been reported to have satisfactory clinical and radiological results with short-and mid-term follow-up in the treatment of cervical degenerative disc disease.However,few reports about the clinical and radiological outcome with more than 5-year follow-up exist.AIM To investigate the long-term clinical and radiological results of DCI arthroplasty.METHODS A total of 40 patients who received DCI arthroplasty were consecutively reviewed from May 2010 to August 2015.Visual analogue scale(VAS),neck disability index(NDI)score,Japanese Orthopaedic Association(JOA)score,and SF-36 items were used to assess neural function rehabilitation.Static and dynamic radiographs and 3-dimentional computed tomography were used to evaluate the radiological outcomes.RESULTS The scores of neck/arm VAS,NDI,JOA,and 8-dimensions of SF-36 were significantly improved at the 1-mo follow-up(P<0.05)and maintained until the last follow-up(P<0.05).The range of motion(ROM)of C2-C7,functional spinal unit(FSU),upper/lower adjacent level,C2-C7 lateral bending,and FSU lateral bending decreased at the 1-mo follow-up(P<0.05),whereas they increased to the preoperative level at the later follow-up intervals(P>0.05),except the ROM of FSU lateral bending(P<0.05).The C2-C7 alignment and FSU angle kept more lordotic at the last follow-up(P<0.05).The intervertebral height increased significantly at the 1-mo follow-up(P<0.05)and decreased at later follow-ups(P>0.05).At the last follow-up,12(26.1%)segments developed heterotopic ossification.CONCLUSION DCI arthroplasty is a safe and effective non-fusion technique to treat cervical degenerative disc disease in long-term follow-up. 展开更多
关键词 Dynamic cervical implant cervical arthroplasty cervical disc degeneration Clinical outcomes Radiological outcomes range of motion
下载PDF
Future of Treatment of Temporomandibular Joint Dysfunctions in Parkinsonian Patients
7
作者 Reda Ahmed Nofal Alaa Abdelqader Altaweel Yasser Ibrahim Seada 《Open Journal of Stomatology》 2014年第4期208-227,共20页
The purpose of the study was designed to clarify the modern trends of physical therapy in treatment of temporomandibular joint dysfunctions in Parkinsonian patients, which in this respect included the degree of pain, ... The purpose of the study was designed to clarify the modern trends of physical therapy in treatment of temporomandibular joint dysfunctions in Parkinsonian patients, which in this respect included the degree of pain, the muscles power of both masseter and pterygoid, the range of TMJ motion, the angle of mouth opening and their effects on electromyography study in both sexes. Subjects: Thirty males and females were the same degree of disabilities according to modified Hoehn and Yahr scales (grade 3) of Parkinsonian patients, and their age ranged from 50 - 77 years old and their weight ranged from 60 - 88 kg. They were randomly divided into two equal groups (G1 and G2). G1 (control) consisted of 15 patients of both sexes and was treated by exercises therapy program and G2 (experimental) consisted of 15 Parkinsonian patients of both sexes and was treated by the same exercises therapy program and low level pulsed electromagnetic therapy. Vital signs such as blood pressure, body temperature, pulse rate and respiratory rate were measured before and after the treatment sessions. Assessments: Visual analogue scale was used to measure degree of pain. Tensiometer was used to measure the muscle power of masseter and pterygoid, the digital goniometer was used to investigate the range of TMJ movement. Moreover, standard electromyography test (EMG) was used to measure the compound muscle action potentials. Statistically the results for all groups were analyzed by t-test to compare the differences between the two groups. The statistical package of social sciences (SPSS, version 10) was used for data processing using the P-value 0.05 as a level of significance. Results showed that there were significant improvements in all variables in G2 only. However, there was a little improvement but not significant in both G1. Therefore, it could be concluded that the use of low level pulsed electro-magnetic therapy combined with exercises program was the good method to control pain of TMJ, increase of muscle power and the range of their movements together with determination of electro-myography. Our results opened a new link to manage the TMJ dysfunctions in Parkinsonian patients via the use of low level pulsed electromagnetic therapy combined with exercises program. 展开更多
关键词 Electromagnetic TEMPOROMANDIBULAR joint Parkinsonian PATIENTS ELECTROMYOGRAPHY TENSIOMETER GONIOMETER Pain and range of motion
下载PDF
The status of the cervical spine in preschool children with a history of congenital muscular torticollis
8
作者 Anna M.Ohman 《Open Journal of Therapy and Rehabilitation》 2013年第2期31-35,共5页
Background: Infants with congenital muscular torticollis are born with an asymmetric range of motion and a muscular imbalance in the cervical spine, as a result of a shortening or excessive contraction of the sternocl... Background: Infants with congenital muscular torticollis are born with an asymmetric range of motion and a muscular imbalance in the cervical spine, as a result of a shortening or excessive contraction of the sternocleidomastoid muscle. Purpose: The study aimed to investigate passive range of motion (PROM) for rotation and lateral flexion, and muscle function of the cervical spine in children that had a history of CMT as infants. Study design: a prospective cohort study. Patient sample: 58 children at the age of 3.5 to 5 years that had been treated for CMT have infants participated in the study. Method: PROM was measured with protractors and muscle function was estimated with a modified Muscle Function Scale. Data from infancy were taken from earlier records. Result: PROM in rotation of the neck was mean 98.7&#176 and PROM in lateral flexion of the neck was mean 69.1&#176. Symmetric PROM of the neck was found in 74% of the children for rotation and in 88% of the children for lateral flexion. Multiple regression showed that gender and PROM in rotation as infants had a significant impact on asymmetric PROM. Forty-five percent of the children had some degree of muscular imbalance in the lateral flexors of the neck. Conclusion: Possible risk factors for later asymmetric PROM are: gender, birth weight, gestation week and PROM in rotation as infants. These factors ought to be taken into consideration when developing guidelines for long-term follow-up. 展开更多
关键词 Congenital Muscular Torticollis cervical Spine Passive range of motion ROTATION Muscle Function CHILDREN
下载PDF
游泳运动对大鼠创伤性关节挛缩的影响及机制
9
作者 税晓平 李春莹 +5 位作者 张鑫 李彬 冯超 周宏宇 陈科 廖莹莹 《中国组织工程研究》 CAS 北大核心 2025年第2期262-268,共7页
背景:早期运动是预防创伤性关节挛缩的主要方式,也是近期研究热点。游泳运动借助水的特殊物理特性,可能是潜在有益的干预方式。目的:观察游泳运动对大鼠关节挛缩发展的影响,探究游泳运动预防关节挛缩的相关机制。方法:24只SD大鼠随机分... 背景:早期运动是预防创伤性关节挛缩的主要方式,也是近期研究热点。游泳运动借助水的特殊物理特性,可能是潜在有益的干预方式。目的:观察游泳运动对大鼠关节挛缩发展的影响,探究游泳运动预防关节挛缩的相关机制。方法:24只SD大鼠随机分为空白对照组(n=8)和关节挛缩造模组(n=16),手术制备膝关节挛缩模型后,再随机分为手术对照组(n=8)和游泳干预组(n=8)。游泳干预组在术后第2周开始游泳干预,共干预5周。在术后第6周,测试各组大鼠体质量、术侧膝关节活动度、股四头肌直径,计算直径-体质量指数;苏木精-伊红染色观察膝关节囊和股四头肌病理变化;Masson染色观察关节囊胶原纤维化改变;免疫组化检测膝关节囊中转化生长因子β1和Ⅰ型胶原蛋白表达;Western blot检测股四头肌中MuRF1蛋白的表达。结果与结论:①与空白对照组比较,手术对照组和游泳干预组大鼠膝关节活动度下降,总伸膝受限角度和关节源性伸膝受限角度均明显增加(P<0.01),股四头肌直径下降(P<0.01),关节囊出现明显纤维化表现,股四头肌萎缩,手术对照组直径-体质量指数降低(P<0.01);与手术对照组比较,游泳干预组大鼠膝关节活动度和股四头肌直径明显增加(P<0.01),关节囊纤维化病变和股四头肌萎缩明显改善;②与空白对照组比较,手术对照组和游泳干预组大鼠关节囊中胶原纤维含量、转化生长因子β1和Ⅰ型胶原蛋白表达均增加(P<0.01);与手术对照组比较,游泳干预组大鼠关节囊中胶原纤维含量、转化生长因子β1和Ⅰ型胶原蛋白表达均降低(P<0.01);③与空白对照组比较,手术对照组和游泳干预组大鼠股四头肌中MuRF1蛋白表达增加(P<0.05);与手术对照组比较,游泳干预组大鼠股四头肌中MuRF1蛋白表达降低(P<0.05)。结果表明:早期游泳干预能够降低创伤性挛缩大鼠关节囊中转化生长因子β1和Ⅰ型胶原蛋白表达,降低股四头肌中MuRF1蛋白表达,提高关节活动度和股四头肌直径,抑制关节挛缩的发展。 展开更多
关键词 关节挛缩 肌肉萎缩 游泳 运动 关节活动度 大鼠
下载PDF
全膝关节置换中BrainlabKnee3导航辅助间隙平衡技术的应用优势
10
作者 孙敬华 齐志明 +2 位作者 阮文礼 张家国 杨智桐 《中国组织工程研究》 CAS 北大核心 2024年第33期5333-5339,共7页
背景:近年来,计算机导航技术辅助关节置换逐渐受到医疗领域的关注。文献报道计算机导航在全膝关节置换中的应用临床效果不一。为了探索新一代Brainlab Knee 3导航系统的临床效果,进行了此项研究。目的:分析计算机导航系统(Brainlab Knee... 背景:近年来,计算机导航技术辅助关节置换逐渐受到医疗领域的关注。文献报道计算机导航在全膝关节置换中的应用临床效果不一。为了探索新一代Brainlab Knee 3导航系统的临床效果,进行了此项研究。目的:分析计算机导航系统(Brainlab Knee 3)结合间隙平衡技术在全膝关节置换中的应用效果。方法:2020年11月至2021年5月大连市第二人民医院关节外科收治71例行全膝关节置换患者,导航组35例,术中采用计算机导航结合间隙平衡技术行全膝关节置换;传统组36例,术中采用传统手术器械定位截骨。比较两组患者术中内、外侧关节间隙差;膝关节活动度、KSS评分;髋膝踝角;冠状面股骨组件角、冠状面胫骨组件角和矢状面胫骨组件角偏差值。结果与结论:①导航组伸直位内外侧间隙差0,1,2 mm的患者分别为19,14,2例;屈膝90°位内外侧间隙差0,1,2 mm的患者分别为18,15,2例。传统组伸直位内外侧间隙差0,1,2 mm的患者分别为10,20,6例;屈膝90°位内外侧间隙差0,1,2 mm的患者分别为10,15,8例。②导航组手术时间长于传统组(P<0.05),导航组有2例患者术后形成下肢肌间静脉血栓,传统组患者均无并发症。③置换后6,12个月两组患者膝关节活动度均明显增加,导航组膝关节活动度高于传统组(P<0.05)。④置换后12个月两组患者KSS评分均明显增加,导航组KSS评分高于传统组(P<0.05)。⑤置换后6个月髋膝踝角、冠状面股骨组件角、冠状面胫骨组件角、矢状面胫骨组件角偏差值均显著小于传统组(P<0.05)。⑥结果表明,采用计算机导航结合间隙平衡技术辅助全膝关节置换对关节活动度、下肢力线、胫骨假体组件位置的准确性方面具有优势,置换后关节功能恢复良好。 展开更多
关键词 全膝关节置换 计算机导航系统 Brainlab Knee 3 下肢力线 关节活动度 髋膝踝角
下载PDF
麦肯基运动疗法联合颈椎关节松动术与耳穴压豆治疗颈型颈椎病临床效果
11
作者 黄海珍 岳红梅 +3 位作者 张妍菀 黄子亮 杜永怡 黄铭康 《中国医学创新》 CAS 2024年第1期81-86,共6页
目的:探讨麦肯基运动疗法联合颈椎关节松动术与耳穴压豆治疗颈型颈椎病临床效果。方法:将广州医科大学附属第六人民医院2021年1月—2022年8月门诊及住院部接收的颈型颈椎病患者160例作为研究对象,采用随机数字表法将其分为对照组与研究... 目的:探讨麦肯基运动疗法联合颈椎关节松动术与耳穴压豆治疗颈型颈椎病临床效果。方法:将广州医科大学附属第六人民医院2021年1月—2022年8月门诊及住院部接收的颈型颈椎病患者160例作为研究对象,采用随机数字表法将其分为对照组与研究组,每组80例。对照组采用麦肯基运动疗法,研究组采用麦肯基运动疗法联合颈椎关节松动术与耳穴压豆治疗,两组均持续治疗3个月。采用颈椎功能障碍指数(NDI)、疼痛灾难化量表(PCS)评价颈功能、疼痛程度。比较两组颈椎活动范围、凝视稳定性(GS)测试阳性率、眼动测试(EMT)阳性率。结果:治疗后,研究组NDI评分低于对照组,差异有统计学意义(P<0.05)。治疗后,研究组PCS评分的疼痛反复思虑、疼痛无助感、疼痛夸大维度得分及总分均低于对照组,差异均有统计学意义(P<0.05)。治疗后,研究组颈椎前屈、后伸、左右侧屈、左右旋转活动范围均高于对照组,差异均有统计学意义(P<0.05)。治疗后,研究组GS阳性率、EMT阳性率均低于对照组,差异均有统计学意义(P<0.05)。结论:麦肯基运动疗法联合颈椎关节松动术与耳穴压豆治疗颈型颈椎病,可有效恢复颈椎功能,减轻疼痛,增加颈椎活动范围,改善颈椎神经的协调性和稳定性。 展开更多
关键词 颈型颈椎病 麦肯基运动疗法 颈椎关节松动术 耳穴压豆 颈椎功能 疼痛 颈椎活动范围
下载PDF
疼痛护理联合早期康复锻炼在卒中后肩手综合征患者中的应用效果
12
作者 王喆 《中国民康医学》 2024年第9期101-104,共4页
目的:观察疼痛护理联合早期康复锻炼在卒中后肩手综合征(SHS)患者中的应用效果。方法:选取2020年9月至2022年9月该院收治的106例卒中后SHS患者进行前瞻性研究,按照随机数字表法将其分为对照组和研究组各53例。对照组给予早期康复锻炼,... 目的:观察疼痛护理联合早期康复锻炼在卒中后肩手综合征(SHS)患者中的应用效果。方法:选取2020年9月至2022年9月该院收治的106例卒中后SHS患者进行前瞻性研究,按照随机数字表法将其分为对照组和研究组各53例。对照组给予早期康复锻炼,研究组在对照组基础上联合疼痛护理。比较两组护理前后疼痛程度[视觉模拟评分法(VAS)]评分、肿胀程度(MRC)评分、上肢功能[Fugl-Meyer运动功能评估表(FMA)]评分、肩关节活动度、肩手等速肌力和生命质量[生活质量综合评定问卷-74(GQOLI-74)]评分。结果:护理后,两组MRC和VAS评分均低于护理前,且研究组低于对照组,两组上肢FMA评分均高于护理前,且研究组高于对照组,差异有统计学意义(P<0.05);两组肩关节外展、前屈活动度均高于护理前,且研究组高于对照组,差异有统计学意义(P<0.05);两组肩、手的屈肌群平均功率、峰值力矩水平均高于护理前,且研究组高于对照组,差异有统计学意义(P<0.05);两组GQOLI-74评分均高于护理前,且研究组高于对照组,差异有统计学意义(P<0.05)。结论:疼痛护理联合早期康复锻炼应用于卒中后SHS患者,可减轻患者肢体肿胀程度和疼痛程度,改善肩关节活动度和肩手等速肌力,提高上肢运动功能和生命质量,效果优于单纯早期康复锻炼。 展开更多
关键词 疼痛护理 早期康复锻炼 卒中后肩手综合征 肩关节活动度 生命质量
下载PDF
保乳术联合乳腔镜腋窝淋巴结清扫术治疗早期乳腺癌的效果
13
作者 郭晓龙 张芳媛 《妇儿健康导刊》 2024年第8期106-109,共4页
目的探讨保乳术联合乳腔镜腋窝淋巴结清扫术治疗早期乳腺癌的效果。方法选取2021年9月至2022年12月淄博市妇幼保健院乳腺甲状腺外科收治的66例早期乳腺癌患者作为研究对象,按照单双号分组法分为对照组和观察组,每组各33例。对照组行保... 目的探讨保乳术联合乳腔镜腋窝淋巴结清扫术治疗早期乳腺癌的效果。方法选取2021年9月至2022年12月淄博市妇幼保健院乳腺甲状腺外科收治的66例早期乳腺癌患者作为研究对象,按照单双号分组法分为对照组和观察组,每组各33例。对照组行保乳术联合常规腋窝淋巴结清扫术,观察组行保乳术联合乳腔镜腋窝淋巴结清扫术。比较两组肩关节活动度、并发症总发生率、引流管留置时间及术后引流量。结果术后3个月,两组肩关节活动度均小于术前,但观察组大于对照组(P<0.05)。观察组并发症总发生率低于对照组(P<0.05)。观察组引流管留置时间短于对照组,术后引流量少于对照组(P<0.05)。结论保乳术联合乳腔镜腋窝淋巴结清扫术治疗早期乳腺癌,可减少对肩关节活动度的影响,降低并发症发生率,缩短引流管留置时间,减少术后引流量,值得临床推广。 展开更多
关键词 乳腔镜腋窝淋巴结清扫术 早期乳腺癌 保乳术 肩关节活动度 并发症总发生率
下载PDF
PNF训练对膝骨关节炎老年患者的康复效果研究
14
作者 沈培鑫 赵硕 +3 位作者 肖尧 罗心 毛德伟 宋祺鹏 《山东体育学院学报》 北大核心 2024年第2期104-114,共11页
目的:探索6周神经肌肉本体感觉促进技术(PNF)训练对膝骨关节炎(KOA)老年患者关节疼痛、身体稳定性和楼梯步态的影响。方法:将36名老年志愿者随机分入PNF组和对照组,分别进行每周3次、每次1h、持续6周的PNF训练及健康宣教。干预前、后分... 目的:探索6周神经肌肉本体感觉促进技术(PNF)训练对膝骨关节炎(KOA)老年患者关节疼痛、身体稳定性和楼梯步态的影响。方法:将36名老年志愿者随机分入PNF组和对照组,分别进行每周3次、每次1h、持续6周的PNF训练及健康宣教。干预前、后分别评估其疼痛、身体稳定性、主动关节活动度(ROM)、关节角度和力矩等,并应用双因素重复性方差分析评估干预效果。结果:相比干预前,干预后PNF组疼痛分数降低,伯格平衡分数提高,起立行走测试时间缩短,下肢主动ROM增加,下楼梯时髋内收峰值力矩增加,上楼梯时膝内收峰值力矩减小。结论:PNF训练干预能有效缓解KOA老年患者的关节疼痛,提高其身体稳定性和改善楼梯行走功能,可推广应用于KOA的临床治疗。 展开更多
关键词 关节活动度 关节力矩 伯格平衡量表 起立行走测试 PNF训练 膝骨关节炎
下载PDF
郑氏经验穴结合肩关节运动干预治疗肩峰撞击综合征临床研究
15
作者 张琳 罗婧婷 +1 位作者 刘剑伟 唐浩琛 《陕西中医》 CAS 2024年第6期846-849,854,共5页
目的:探究郑氏经验穴结合肩关节运动干预对肩峰撞击综合征(SIS)的临床疗效。方法:选取96例SIS患者,随机分为对照组和观察组各48例。对照组采用肩关节运动治疗,观察组采用郑氏经验穴结合肩关节运动治疗,1个治疗周期为3周。评估两组治疗... 目的:探究郑氏经验穴结合肩关节运动干预对肩峰撞击综合征(SIS)的临床疗效。方法:选取96例SIS患者,随机分为对照组和观察组各48例。对照组采用肩关节运动治疗,观察组采用郑氏经验穴结合肩关节运动治疗,1个治疗周期为3周。评估两组治疗后治疗效果、肩关节活动度、肩部肌力及不良反应。结果:治疗3周后,观察组治疗有效率91.67%明显高于对照组的75.00%,治疗1、3周后观察组Constant-Murley评分显著高于对照组(P<0.05)。治疗3周后,观察组各关节活动度,肩部各部位肌力明显高于对照组(P<0.05)。观察组不良反应发生情况较少。结论:郑氏经验穴结合肩关节运动干预对SIS可以提高其临床治疗效果,缓解患者疼痛,有效提高肩关节活动度和肩部肌力,且较安全。 展开更多
关键词 肩峰撞击综合征 郑氏经验穴 肩关节运动 肩关节活动度 肩部肌力
下载PDF
Coda Motion运动分析系统测量健康人颈椎侧屈活动度的准确性分析 被引量:1
16
作者 宋辉 高中洋 +4 位作者 赵英杰 高正超 邱晓文 李浩鹏 贺西京 《中国骨伤》 CAS 2018年第11期1017-1021,共5页
目的:探讨Coda Motion运动分析系统测量颈椎侧屈活动度的准确性,为临床及科研实践探索一种新的测量工具。方法:选择43名健康志愿者作为研究对象,采用Coda Motion运动分析系统和"金标准"X线两种工具同时测量其颈椎侧屈活动度... 目的:探讨Coda Motion运动分析系统测量颈椎侧屈活动度的准确性,为临床及科研实践探索一种新的测量工具。方法:选择43名健康志愿者作为研究对象,采用Coda Motion运动分析系统和"金标准"X线两种工具同时测量其颈椎侧屈活动度。运用散点图、皮尔森相关系数r评估Coda Motion运动分析系统测量颈椎侧屈活动度的准确性。结果:Coda Motion运动分析系统与X线测量出的颈椎侧屈活动度差异无统计学意义(P>0.05)。两种工具在测量右侧屈、左侧屈以及总侧屈活动度呈正相关,皮尔森相关系数分别为0.72、0.85和0.90。结论:Coda Motion运动分析系统测量颈椎侧屈活动度的准确性好,可能作为一种新型测量工具用于临床及科研测量颈椎侧屈活动度的实践中。 展开更多
关键词 颈椎活动度 侧屈 CODA motion运动分析系统
下载PDF
促愈消肿汤对运动致肱骨远端骨折患者术后骨生长及功能恢复的影响
17
作者 杨柏琦 马金叶 +1 位作者 齐素兰 郭中华 《世界中医药》 CAS 北大核心 2024年第3期383-387,共5页
目的:探究促愈消肿汤对运动致肱骨远端骨折患者术后血清成纤维细胞生长因子2(FGF-2)、骨形态发生蛋白7(BMP-7)水平及骨愈合状态的影响。方法:选取2021年3月至2022年9月河南省中医院收治的运动致肱骨远端骨折患者86例作为研究对象,采用... 目的:探究促愈消肿汤对运动致肱骨远端骨折患者术后血清成纤维细胞生长因子2(FGF-2)、骨形态发生蛋白7(BMP-7)水平及骨愈合状态的影响。方法:选取2021年3月至2022年9月河南省中医院收治的运动致肱骨远端骨折患者86例作为研究对象,采用随机数字法分为对照组和观察组,每组43例。对照组术后采用常规康复治疗;观察组在对照组基础上服用促愈消肿汤治疗。对比治疗后2组临床疗效及术后恢复情况,术后1 d与术后7 d时2组肘关节功能、关节活动度及血清FGF-2、BMP-7水平差异。结果:观察组临床疗效为93.02%,显著高于对照组的76.74%(P<0.05);治疗后观察组疼痛消除时间、术处消肿时间及骨折愈合时间显著短于对照组(均P<0.05);术后7 d时,观察组Mayo肘关节功能量表,关节活动度(ROM)评分以及血清FGF-2、BMP-7水平显著升高,且高于对照组(均P<0.05);术后7 d时,观察组视觉模拟评分法(VAS)得分较术后1 d时显著降低,且低于对照组(均P<0.05)。结论:运动致肱骨远端骨折患者术后服用促愈消肿汤能有效促进血清FGF-2、BMP-7水平表达上调,改善肘关节活动功能,缓解术后疼痛,加速骨折愈合。 展开更多
关键词 促愈消肿汤 肱骨远端骨折 成纤维细胞生长因子2 骨形态发生蛋白7 骨生长指标 肘关节功能 关节活动度 视觉模拟评分法
下载PDF
超声波治疗仪联合悬吊运动疗法在肌筋膜疼痛综合征患者中的应用研究
18
作者 王丽娜 苏小君 周慧青 《医疗装备》 2024年第5期12-15,共4页
目的探讨超声波治疗仪联合悬吊运动疗法(SET)在肌筋膜疼痛综合征(MPS)患者中的应用。方法选取2022年1月至2023年4月于医院就诊的MPS患者76例,采用随机数字表法分为试验组和对照组,每组38例。对照组予SET治疗,试验组在对照组基础上采用... 目的探讨超声波治疗仪联合悬吊运动疗法(SET)在肌筋膜疼痛综合征(MPS)患者中的应用。方法选取2022年1月至2023年4月于医院就诊的MPS患者76例,采用随机数字表法分为试验组和对照组,每组38例。对照组予SET治疗,试验组在对照组基础上采用超声波治疗仪治疗,两组均治疗4周。比较两组治疗前后腰背部疼痛[目测类比评分法(VAS)和麦吉尔疼痛问卷(MPQ)]、腰椎功能[日本骨科协会评分(JOA)]、腰椎关节活动度(ROM)、腰背肌核心肌群肌电图[平均肌电波幅度(AEMG)和频域分析值(MPF)]变化,以及临床疗效。结果治疗后,两组VAS评分和MPQ评分低于治疗前,JOA评分高于治疗前(P<0.05),且试验组VAS评分和MPQ评分低于对照组,JOA评分高于对照组(P<0.05);治疗后,两组腰椎前屈ROM和后伸ROM高于治疗前(P<0.05),且试验组均高于对照组(P<0.05);治疗后,两组EMG和MPF高于治疗前(P<0.05),且试验组均高于对照组(P<0.05)。治疗后,试验组临床总有效率高于对照组(P<0.05)。结论超声波治疗仪联合SET治疗MPS患者的疗效肯定,可减轻腰背部疼痛,改善腰背肌的肌张力,提高腰椎功能和腰椎关节ROM。 展开更多
关键词 肌筋膜疼痛综合征 悬吊运动疗法 超声波治疗仪 疼痛 腰椎功能 腰椎关节活动度 肌电图
下载PDF
显微外科手术治疗屈指肌腱损伤的效果及对手功能和炎症的影响
19
作者 王志炜 蓝贤峰 吴学军 《中外医学研究》 2024年第5期39-43,共5页
目的:观察显微外科手术治疗屈指肌腱损伤的效果及对手功能和炎症的影响。方法:回顾性分析2020年9月—2023年3月福州市第二医院收治的98例屈指肌腱损伤患者的临床资料。根据不同治疗方式将其分为研究组和对照组,各49例。研究组采用显微... 目的:观察显微外科手术治疗屈指肌腱损伤的效果及对手功能和炎症的影响。方法:回顾性分析2020年9月—2023年3月福州市第二医院收治的98例屈指肌腱损伤患者的临床资料。根据不同治疗方式将其分为研究组和对照组,各49例。研究组采用显微外科手术治疗,对照组采用常规修复手术治疗。比较两组术前和术后2个月手功能、疼痛程度,指关节活动度及握力力度,术前和术后3 d炎症因子,临床疗效。结果:术后2个月,两组Carroll上肢功能评分升高,视觉模拟评分法(visual analogue score,VAS)评分降低,研究组Carroll上肢功能评分和握力力度均高于对照组,VAS评分低于对照组,差异有统计学意义(P<0.05)。研究组术后并发症发生率低于对照组,差异有统计学意义(P<0.05)。术后2个月,研究组拇指、示指、中指和环指、小指指关节活动度均高于对照组,差异有统计学意义(P<0.05)。术后3 d,两组C反应蛋白(C-reactive protein,CRP)、降钙素原(procalcitonin,PCT)和白细胞介素-6(interleukin-6,IL-6)水平均降低,研究组PCT、IL-6、CRP水平均低于对照组,差异有统计学意义(P<0.05)。研究组优良率高于对照组,差异有统计学意义(P<0.05)。结论:显微外科手术治疗屈指肌腱损伤效果较好,可有效提升患者手功能和关节活动度,缓解炎症刺激和疼痛程度,改善临床症状和预后表现,术式实用性和安全性较高。 展开更多
关键词 显微外科手术 常规修复术 屈指肌腱损伤 手功能 炎症刺激 关节活动度
下载PDF
中医推拿联合运动康复治疗神经根型颈椎病的临床效果
20
作者 冯国强 徐锋 +2 位作者 张娟娟 余桃春 向维聂 《浙江医学教育》 2024年第1期60-64,共5页
目的 探讨中医推拿联合运动康复治疗神经根型颈椎病(cervical spondylotic radiculopathy, CSR)的临床疗效。方法 选择2022年6月至2022年12月九江学院附属医院康复医学科诊治的18~70岁符合CSR诊断标准的80例患者为研究对象,将其随机分... 目的 探讨中医推拿联合运动康复治疗神经根型颈椎病(cervical spondylotic radiculopathy, CSR)的临床疗效。方法 选择2022年6月至2022年12月九江学院附属医院康复医学科诊治的18~70岁符合CSR诊断标准的80例患者为研究对象,将其随机分为试验组和对照组,治疗过程中8例脱落,最终参与本研究的有72例患者,每组36例患者。试验组患者采用中医推拿联合运动康复疗法,每周治疗5次,每次60分钟,共治疗2周10次;对照组患者采用中医推拿疗法,每周治疗5次,每次30分钟,共治疗2周10次。比较两组患者治疗前后田中靖久颈椎病症状量表20分法、视觉模拟评分法(visual analogue scale, VAS)、颈椎活动度(range of motion, ROM)评价结果和临床疗效变化情况。结果 与治疗前比较,试验组患者田中靖久量表评分,颈椎后伸、左旋和右旋ROM显著增加,VAS评分显著降低,其差异均具有统计学意义(均P<0.01);对照组患者田中靖久量表评分,颈椎前屈、左旋和右旋ROM显著增加,VAS评分显著减低,其差异均具有统计学意义(均P<0.05)。治疗后,试验组患者田中靖久量表评分,颈椎左旋和右旋ROM显著高于对照组患者,VAS评分显著低于对照组患者,其差异均具有统计学意义(均P<0.01)。结论 中医推拿联合运动康复治疗CSR,能够显著改善患者临床症状,减轻疼痛,改善颈椎ROM,具有较好的临床应用价值。 展开更多
关键词 中医推拿 运动康复 神经根型颈椎病 疼痛 活动度
下载PDF
上一页 1 2 37 下一页 到第
使用帮助 返回顶部